{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,6]],"date-time":"2024-09-06T01:39:13Z","timestamp":1725586753942},"publisher-location":"Berlin, Heidelberg","reference-count":15,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642215032"},{"type":"electronic","value":"9783642215049"}],"license":[{"start":{"date-parts":[[2011,1,1]],"date-time":"2011-01-01T00:00:00Z","timestamp":1293840000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011]]},"DOI":"10.1007\/978-3-642-21504-9_14","type":"book-chapter","created":{"date-parts":[[2011,6,17]],"date-time":"2011-06-17T23:49:13Z","timestamp":1308354553000},"page":"145-155","source":"Crossref","is-referenced-by-count":8,"title":["Image-Based Automatic Ablation Point Tagging System with Motion Correction for Cardiac Ablation Procedures"],"prefix":"10.1007","author":[{"given":"YingLiang","family":"Ma","sequence":"first","affiliation":[]},{"given":"Gang","family":"Gao","sequence":"additional","affiliation":[]},{"given":"Geert","family":"Gijsbers","sequence":"additional","affiliation":[]},{"given":"C. Aldo","family":"Rinaldi","sequence":"additional","affiliation":[]},{"given":"Jaswinder","family":"Gill","sequence":"additional","affiliation":[]},{"given":"Reza","family":"Razavi","sequence":"additional","affiliation":[]},{"given":"Kawal S.","family":"Rhode","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"issue":"11","key":"14_CR1","first-page":"810","volume":"24","author":"K.S. Rhode","year":"2003","unstructured":"Rhode, K.S., Hill, D.L.G., Edwards, P.J., Hipwell, J., Rueckert, D., Sanchez-Ortiz, G., Hegde, S., Rahunathan, V., Razavi, R.: Registration and tracking to integrate X-ray and MR images in an XMR facility. IEEE Transactions on Medical Imaging\u00a024(11), 810\u2013815 (2003)","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"14_CR2","volume-title":"Practical Radiography - Principles and Applications","author":"P. Hertrich","year":"2005","unstructured":"Hertrich, P.: Practical Radiography - Principles and Applications, 1st edn. Publicis Corporate Publishing, Erlangen (2005)","edition":"1"},{"issue":"11","key":"14_CR3","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1109\/TMI.2009.2025499","volume":"28","author":"M. Pruemmer","year":"2009","unstructured":"Pruemmer, M., Hornegger, J., Lauritsch, G., Wigstrom, L., Girard-Hughes, E., Fahrig, R.: Cardiac C-arm CT: a unified framework for motion estimation and dynamic CT. IEEE Trans. Med. Imaging\u00a028(11), 1836\u20131849 (2009)","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"1","key":"14_CR4","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.hrthm.2006.10.003","volume":"4","author":"M.V. Orlov","year":"2007","unstructured":"Orlov, M.V., Hoffmeister, P., Chaudhry, G.M., Almasry, I., Gijsbers, G.H., Swack, T., Haffajee, C.I.: Three-dimensional rotational angiography of the left atrium and esophagus\u2013A virtual computed tomography scan in the electrophysiology lab. Heart Rhythm\u00a04(1), 37\u201343 (2007)","journal-title":"Heart Rhythm"},{"issue":"11","key":"14_CR5","doi-asserted-by":"publisher","first-page":"1407","DOI":"10.1111\/j.1540-8159.2009.02481.x","volume":"32","author":"M. Tang","year":"2009","unstructured":"Tang, M., Kriatselis, C., Ye, G., Nedios, S., Roser, M., Solowjowa, N., Fleck, E., Gerds-Li, J.H.: Reconstructing and registering three-dimensional rotational angiogram of left atrium during ablation of atrial fibrillation. Pacing Clin. Electrophysiol.\u00a032(11), 1407\u20131416 (2009)","journal-title":"Pacing Clin. Electrophysiol."},{"issue":"8","key":"14_CR6","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1093\/europace\/eun145","volume":"10","author":"S. Knecht","year":"2008","unstructured":"Knecht, S., Skali, H., O\u2019Neill, M.D., Wright, M., Matsuo, S., Chaudhry, G.M., Haffajee, C.I., Nault, I., Gijsbers, G.H., Sacher, F., Laurent, F., Montaudon, M., Corneloup, O., Hocini, M., Ha\u00efssaguerre, M., Orlov, M.V., Ja\u00efs, P.: Computed tomography-fluoroscopy overlay evaluation during catheter ablation of left atrial arrhythmia. Europace\u00a010(8), 931\u2013938 (2008)","journal-title":"Europace"},{"issue":"4","key":"14_CR7","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1016\/j.hrthm.2008.01.008","volume":"5","author":"A.G. Brooks","year":"2008","unstructured":"Brooks, A.G., Wilson, L., Kuklik, P., Stiles, M.K., John, B., Shashidhar, D.H., Lau, D.H., Roberts-Thomson, R.L., Wong, C.X., Young, G.D., Sanders, P.: Image integration using NavX fusion: Initial experience and validation. Heart Rhythm\u00a05(4), 526\u2013535 (2008)","journal-title":"Heart Rhythm"},{"key":"14_CR8","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/11866763_4","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2006","author":"E. Franken","year":"2006","unstructured":"Franken, E., Rongen, P., van Almsick, M., ter Haar Romeny, B.M.: Detection of Electrophysiology Catheters in Noisy Fluoroscopy Images. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol.\u00a04191, pp. 25\u201332. Springer, Heidelberg (2006)"},{"issue":"3","key":"14_CR9","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/j.media.2009.01.003","volume":"13","author":"A.P. King","year":"2009","unstructured":"King, A.P., Boubertakh, R., Rhode, K.S., Ma, Y.L., Chinchapatnam, P., Gao, G., Tangcharoen, T., Ginks, M., Hawkes, D.J., Razavi, R.S., Schaeffter, T.: A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures. Med. Image. Anal.\u00a013(3), 419\u2013431 (2009)","journal-title":"Med. Image. Anal."},{"issue":"4","key":"14_CR10","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1109\/TMI.2004.839679","volume":"24","author":"G. Shechter","year":"2005","unstructured":"Shechter, G., Shechter, B., Resar, J.R., Beyar, R.: Prospective motion correction of X-ray images for coronary interventions. IEEE Transactions on Medical Imaging\u00a024(4), 441\u2013450 (2005)","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"14_CR11","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1007\/978-3-642-04271-3_47","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2009","author":"H. Sundar","year":"2009","unstructured":"Sundar, H., Khamene, A., Yatziv, L., Xu, C.: Automatic Image-Based Cardiac and Respiratory Cycle Synchronization and Gating of Image Sequences. In: Yang, G.-Z., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds.) MICCAI 2009. LNCS, vol.\u00a05762, pp. 381\u2013388. Springer, Heidelberg (2009)"},{"key":"14_CR12","doi-asserted-by":"crossref","unstructured":"Brost, A., Liao, R., Strobel, N., Hornegger, J.: Respiratory motion compensation by model-based catheter tracking during EP procedures. Med. Image. Anal.\u00a014(5), 695\u2013706 (2010)","DOI":"10.1016\/j.media.2010.05.006"},{"key":"14_CR13","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1007\/978-3-642-15705-9_48","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2010","author":"Y. Ma","year":"2010","unstructured":"Ma, Y., King, A.P., Gogin, N., Rinaldi, C.A., Gill, J., Razavi, R., Rhode, K.S.: Real-time respiratory motion correction for cardiac electrophysiology procedures using image-based coronary sinus catheter tracking. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010. LNCS, vol.\u00a06361, pp. 391\u2013399. Springer, Heidelberg (2010)"},{"key":"14_CR14","unstructured":"Hoffman, K., Sen, A., Lan, L., Metz, C., Chua, K., Williams, B., Esthappen, J., Fiebich, M., Mazzucco, M., Doi, K.: Determination of 3-D vessel trees from biplane images from coronary angiography. Computer. Assisted Radiology Surgery, 162\u2013165 (1997)"},{"issue":"3","key":"14_CR15","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/BF01469346","volume":"11","author":"L. Tony","year":"1993","unstructured":"Tony, L.: Detecting salient blob-like image structures and their scales with a scale-space primal sketch: a Method for focus-of-attention. International Journal of Computer Vision\u00a011(3), 283\u2013318 (1993)","journal-title":"International Journal of Computer Vision"}],"container-title":["Lecture Notes in Computer Science","Information Processing in Computer-Assisted Interventions"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-21504-9_14","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T23:33:32Z","timestamp":1560296012000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-642-21504-9_14"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011]]},"ISBN":["9783642215032","9783642215049"],"references-count":15,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-21504-9_14","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2011]]}}}