{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T15:57:45Z","timestamp":1725897465620},"publisher-location":"Berlin, Heidelberg","reference-count":21,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642297335"},{"type":"electronic","value":"9783642297342"}],"license":[{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012]]},"DOI":"10.1007\/978-3-642-29734-2_15","type":"book-chapter","created":{"date-parts":[[2012,5,29]],"date-time":"2012-05-29T04:00:13Z","timestamp":1338264013000},"page":"103-110","source":"Crossref","is-referenced-by-count":6,"title":["In Vitro and In Vivo Operation of a Wireless Body Sensor Node"],"prefix":"10.1007","author":[{"given":"Francesco","family":"Merli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L\u00e9andre","family":"Bolomey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Gorostidi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yann","family":"Barrandon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric","family":"Meurville","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anja K.","family":"Skrivervik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"issue":"12","key":"15_CR1","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1109\/TBME.2007.908332","volume":"54","author":"J.L. Gonzalez-Guillaumin","year":"2007","unstructured":"Gonzalez-Guillaumin, J.L., Sadowski, D.C., Kaler, K.V.I.S., Mintchev, M.P.: Ingestible capsule for impedance and pH monitoring in the esophagus. IEEE Trans. Biomed. Eng.\u00a054(12), 2231\u20132236 (2007)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"15_CR2","unstructured":"Pill cam, Given Imaging, \n                    \n                      http:\/\/www.givenimaging.com\/en-us\/Pages\/GivenWelcomePage.aspx"},{"issue":"11","key":"15_CR3","doi-asserted-by":"publisher","first-page":"2333","DOI":"10.1109\/TBME.2006.883698","volume":"53","author":"E.A. Johannessen","year":"2006","unstructured":"Johannessen, E.A., Wang, L., Wyse, C., Cumming, D.R.S., Cooper, J.M.: Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal environments. IEEE Trans. Biomed. Eng.\u00a053(11), 2333\u20132340 (2006)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"6","key":"15_CR4","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1109\/TBME.2010.2041058","volume":"57","author":"E.Y. Chow","year":"2010","unstructured":"Chow, E.Y., Chlebowski, A.L., Chakraborty, S., Chappell, W.J., Irazoqui, P.P.: Fully wireless implantable cardiovascular pressure monitor integrated with a medical stent. IEEE Trans. Biomed. Eng.\u00a057(6), 1487\u20131496 (2010)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"15_CR5","unstructured":"Medical Device Radiocommunications Service (MedRadio), Federal Communication Commission (FCC) Std. CFR, Part 95.601-673 Subpart E, Part 95.1201-1221 Subpart I, formerly. Medical Implanted Communication System (MICS) (2009), \n                    \n                      http:\/\/wireless.fcc.gov\/services\/index.htm?job=service_home&id=medical_implant"},{"issue":"1","key":"15_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.snb.2009.12.029","volume":"146","author":"S. Kuenzi","year":"2010","unstructured":"Kuenzi, S., Meurville, E., Ryser, P.: Automated characterization of dextran\/ concanavalin a mixtures\u2013a study of sensitivity and temperature dependence at low viscosity as basis for an implantable glucose sensor. Sensors and Actuators B: Chemical\u00a0146(1), 1\u20137 (2010)","journal-title":"Sensors and Actuators B: Chemical"},{"key":"15_CR7","doi-asserted-by":"crossref","unstructured":"Merli, F., Bolomey, L., Meurville, E., Skrivervik, A.K.: Dual band antenna for subcutaneous telemetry applications. In: Proc. IEEE Antennas and Propagation Society Int. Symp. (APSURSI), pp. 1\u20134 (2010)","DOI":"10.1109\/APS.2010.5562054"},{"issue":"10","key":"15_CR8","doi-asserted-by":"publisher","first-page":"3544","DOI":"10.1109\/TAP.2011.2163763","volume":"59","author":"F. Merli","year":"2011","unstructured":"Merli, F., Bolomey, L., Z\u00fcrcher, J.-F., Corradini, G., Meurville, E., Skrivervik, A.K.: Design, realization and measurements of a miniature antenna for implantable wireless communication systems. IEEE Trans. Antennas Propag.\u00a059(10), 3544\u20133555 (2011)","journal-title":"IEEE Trans. Antennas Propag."},{"issue":"3","key":"15_CR9","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1109\/TBME.2003.820370","volume":"51","author":"E.A. Johannessen","year":"2004","unstructured":"Johannessen, E.A., Wang, L., Cui, L., Tang, T.B., Ahmadian, M., Astaras, A., Reid, S.W.J., Yam, P.S., Murray, A.F., Flynn, B.W., Beaumont, S.P., Cumming, D.R.S., Cooper, J.M.: Implementation of multichannel sensors for remote biomedical measurements in a microsystems format. IEEE Trans. Biomed. Eng.\u00a051(3), 525\u2013535 (2004)","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"32","key":"15_CR10","doi-asserted-by":"publisher","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","volume":"28","author":"S.M. Kurtz","year":"2007","unstructured":"Kurtz, S.M., Devine, J.N.: PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials\u00a028(32), 4845\u20134869 (2007)","journal-title":"Biomaterials"},{"issue":"1","key":"15_CR11","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1109\/TAP.2010.2090465","volume":"59","author":"F. Merli","year":"2011","unstructured":"Merli, F., Fuchs, B., Mosig, J.R., Skrivervik, A.K.: The effect of insulating layers on the performance of implanted antennas. IEEE Trans. Antennas Propag.\u00a059(1), 21\u201331 (2011)","journal-title":"IEEE Trans. Antennas Propag."},{"key":"15_CR12","doi-asserted-by":"crossref","unstructured":"Bolomey, L., Meurville, E., Ryser, P.: Implantable ultra-low power DSP-based system for a miniature chemico-rheological biosensor. In: Proceedings of the Eurosensors XXIII Conference, vol.\u00a0(1), pp. 1235\u20131238 (2009)","DOI":"10.1016\/j.proche.2009.07.308"},{"key":"15_CR13","unstructured":"Bradley, P.D.: Implantable ultralow-power radio chip facilitates in-body communications. RF Design (online magazine) (2007), \n                    \n                      http:\/\/rfdesign.com\/next_generation_wireless\/short_range_wireless\/706RFDF1.pdf"},{"key":"15_CR14","doi-asserted-by":"crossref","unstructured":"De Micheli, G., Ghoreishizadeh, S., Boero, C., Valgimigli, F., Carrara, S.: An integrated platform for advanced diagnostics. In: Proc. Design, Automation and Test in Europe (DATE 2011), pp. 2995\u20132999 (2011)","DOI":"10.1109\/DATE.2011.5763235"},{"issue":"6","key":"15_CR15","doi-asserted-by":"publisher","first-page":"1846","DOI":"10.1109\/TBME.2011.2123098","volume":"58","author":"P. Valdastri","year":"2011","unstructured":"Valdastri, P., Susilo, E., Forster, T., Strohhofer, C., Menciassi, A., Dario, P.: Wireless implantable electronic platform for chronic fluorescent-based biosensors. IEEE Trans. Biomed. Eng.\u00a058(6), 1846\u20131854 (2011)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"15_CR16","doi-asserted-by":"crossref","unstructured":"Audet, S., Herrmann, E.J., Receveur, R., et al.: Medical applications. Comprehensive Microsystems, 421\u2013474 (2008)","DOI":"10.1016\/B978-044452190-3.00068-9"},{"key":"15_CR17","doi-asserted-by":"crossref","unstructured":"Valdastri, P., Susilo, E., F\u00f6rster, T., Strohh\u00f6fer, C., Menciassi, A., Dario, P.: Wireless implantable electronic platform for blood glucose level monitoring. In: Proceedings of the Eurosensors XXIII Conference, vol.\u00a0(1), pp. 1255\u20131258 (2009)","DOI":"10.1016\/j.proche.2009.07.313"},{"issue":"3","key":"15_CR18","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1109\/TITB.2004.834389","volume":"8","author":"P. Valdastri","year":"2004","unstructured":"Valdastri, P., Menciassi, A., Arena, A., Caccamo, C., Dario, P.: An implantable telemetry platform system for in vivo monitoring of physiological parameters. IEEE Trans. Inf. Technol. Biomed.\u00a08(3), 271\u2013278 (2004)","journal-title":"IEEE Trans. Inf. Technol. Biomed."},{"issue":"1","key":"15_CR19","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.snb.2009.01.052","volume":"138","author":"C.P. Cheney","year":"2009","unstructured":"Cheney, C.P., Srijanto, B., Hedden, D.L., Gehl, A., Ferrell, T.L., Schultz, J., Engleman, E.A., McBride, W.J., O\u2019Connor, S.: In vivo wireless ethanol vapor detection in the wistar rat. Sens. Actuators B Chem.\u00a0138(1), 264\u2013269 (2009)","journal-title":"Sens. Actuators B Chem."},{"key":"15_CR20","unstructured":"DSI PhysioTel PA-C10 for Mice, data sciences international (2005)"},{"key":"15_CR21","unstructured":"Brouard, Barrandon: Private Communication"}],"container-title":["Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering","Wireless Mobile Communication and Healthcare"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-29734-2_15","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,2]],"date-time":"2019-05-02T17:18:06Z","timestamp":1556817486000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-642-29734-2_15"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012]]},"ISBN":["9783642297335","9783642297342"],"references-count":21,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-29734-2_15","relation":{},"ISSN":["1867-8211","1867-822X"],"issn-type":[{"type":"print","value":"1867-8211"},{"type":"electronic","value":"1867-822X"}],"subject":[],"published":{"date-parts":[[2012]]}}}