{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,7]],"date-time":"2024-09-07T18:09:42Z","timestamp":1725732582872},"publisher-location":"Berlin, Heidelberg","reference-count":22,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783642387081"},{"type":"electronic","value":"9783642387098"}],"license":[{"start":{"date-parts":[[2013,1,1]],"date-time":"2013-01-01T00:00:00Z","timestamp":1356998400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013]]},"DOI":"10.1007\/978-3-642-40811-3_25","type":"book-chapter","created":{"date-parts":[[2013,9,20]],"date-time":"2013-09-20T10:09:07Z","timestamp":1379671747000},"page":"195-202","source":"Crossref","is-referenced-by-count":13,"title":["Efficient Convex Optimization Approach to 3D Non-rigid MR-TRUS Registration"],"prefix":"10.1007","author":[{"given":"Yue","family":"Sun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jing","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Rajchl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wu","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cesare","family":"Romagnoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aaron","family":"Fenster","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"25_CR1","unstructured":"Canadian Cancer Society (2012), \n                    \n                      http:\/\/www.cancer.ca"},{"key":"25_CR2","unstructured":"National Cancer Institute (2012), \n                    \n                      http:\/\/www.cancer.gov"},{"key":"25_CR3","unstructured":"Cancer Research UK (2013), \n                    \n                      http:\/\/www.cancerresearchuk.org"},{"key":"25_CR4","unstructured":"Rifkin, M.: Ultrasound of the prostate: imaging in the diagnosis and therapy of prostatic disease. Lippincott-Raven Publishers (1997)"},{"issue":"4","key":"25_CR5","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/S0090-4295(97)00306-3","volume":"50","author":"M. Norberg","year":"1997","unstructured":"Norberg, M., Egevad, L., Holmberg, L., Spar\u00e9n, P., Norl\u00e9n, B., Busch, C.: The sextant protocol for ultrasound-guided core biopsies of the prostate underestimates the presence of cancer. Urology\u00a050(4), 562\u2013566 (1997)","journal-title":"Urology"},{"issue":"3","key":"25_CR6","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1148\/radiol.2343040363","volume":"234","author":"K.L. Zakian","year":"2005","unstructured":"Zakian, K.L., Sircar, K., Hricak, H., Chen, H.N., Shukla-Dave, A., Eberhardt, S., Muruganandham, M., Ebora, L., Kattan, M.W., Reuter, V.E., Scardino, P.T., Koutcher, J.A.: Correlation of proton MR spectroscopic imaging with gleason score based on step-section pathologic analysis after radical prostatectomy. Radiology\u00a0234(3), 804\u2013814 (2005)","journal-title":"Radiology"},{"key":"25_CR7","doi-asserted-by":"crossref","first-page":"W715","DOI":"10.2214\/AJR.10.5700","volume":"196","author":"J. Vilanova","year":"2011","unstructured":"Vilanova, J., Barcel\u00f3-Vidal, C., Comet, J., Boada, M., Barcel\u00f3, J., Ferrer, J., Albanell, J.: Usefulness of prebiopsy multifunctional and morphologic MRI combined with free-to-total prostate-specific antigen ratio in the detection of prostate cancer. American Journal of Roen\u00a0196, W715\u2013W722 (2011)","journal-title":"American Journal of Roen"},{"issue":"1","key":"25_CR8","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.juro.2012.08.095","volume":"189","author":"G.A. Sonn","year":"2013","unstructured":"Sonn, G.A., Natarajan, S., Margolis, D.J., MacAiran, M., Lieu, P., Huang, J., Dorey, F.J., Marks, L.S.: Targeted biopsy in the detection of prostate cancer using an office based magnetic resonance ultrasound fusion device. The Journal of Urology\u00a0189(1), 86\u201392 (2013)","journal-title":"The Journal of Urology"},{"issue":"3","key":"25_CR9","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.media.2010.11.003","volume":"16","author":"Y. Hu","year":"2012","unstructured":"Hu, Y., Ahmed, H.U., Taylor, Z., Allen, C., Emberton, M., Hawkes, D., Barratt, D.: MR to ultrasound registration for image-guided prostate interventions. Medical Image Analysis\u00a016(3), 687\u2013703 (2012)","journal-title":"Medical Image Analysis"},{"issue":"6","key":"25_CR10","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1016\/j.media.2012.04.006","volume":"16","author":"J. Mitra","year":"2012","unstructured":"Mitra, J., Kato, Z., Marti, R., Oliver, A., Llad, X., Sidib, D., Ghose, S., Vilanova, J.C., Comet, J., Meriaudeau, F.: A spline-based non-linear diffeomorphism for multimodal prostate registration. Medical Image Analysis\u00a016(6), 1259\u20131279 (2012)","journal-title":"Medical Image Analysis"},{"issue":"7","key":"25_CR11","first-page":"1423","volume":"16","author":"M.P. Heinrich","year":"2012","unstructured":"Heinrich, M.P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F.V., Brady, S.M., Schnabel, J.A.: Mind: Modality independent neighbourhood descriptor for multi-modal deformable registration. MedIA\u00a016(7), 1423\u20131435 (2012)","journal-title":"MedIA"},{"key":"25_CR12","unstructured":"Buades, A., Coll, B., Morel, J.M.: A non-local algorithm for image denoising. In: CVPR, pp. 60\u201365 (2005)"},{"issue":"3","key":"25_CR13","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1023\/A:1020830525823","volume":"50","author":"G. Hermosillo","year":"2002","unstructured":"Hermosillo, G., Chefd\u2019Hotel, C., Faugeras, O.D.: Variational methods for multimodal image matching. International Journal of Computer Vision\u00a050(3), 329\u2013343 (2002)","journal-title":"International Journal of Computer Vision"},{"issue":"1","key":"25_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.media.2011.03.001","volume":"16","author":"C. Wachinger","year":"2012","unstructured":"Wachinger, C., Navab, N.: Entropy and laplacian images: Structural representations for multi-modal registration. Medical Image Analysis\u00a016(1), 1\u201317 (2012)","journal-title":"Medical Image Analysis"},{"key":"25_CR15","doi-asserted-by":"crossref","unstructured":"Yuan, J., Bae, E., Tai, X.: A study on continuous max-flow and min-cut approaches. In: CVPR (2010)","DOI":"10.1109\/CVPR.2010.5539903"},{"key":"25_CR16","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/978-3-642-15567-3_28","volume-title":"Computer Vision \u2013 ECCV 2010","author":"J. Yuan","year":"2010","unstructured":"Yuan, J., Bae, E., Tai, X.-C., Boykov, Y.: A continuous max-flow approach to potts model. In: Daniilidis, K., Maragos, P., Paragios, N. (eds.) ECCV 2010, Part VI. LNCS, vol.\u00a06316, pp. 379\u2013392. Springer, Heidelberg (2010)"},{"issue":"5","key":"25_CR17","first-page":"694","volume":"17","author":"J. Fitzpatrick","year":"1998","unstructured":"Fitzpatrick, J., West, J., Maurer Jr., C.R.: Predicting error in rigid-body point-based registration. IEEE TMI\u00a017(5), 694\u2013702 (1998)","journal-title":"IEEE TMI"},{"issue":"2","key":"25_CR18","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/S1076-6332(03)00671-8","volume":"11","author":"K. Zou","year":"2004","unstructured":"Zou, K., Warfield, S., Bharatha, A., Tempany, C., Kaus, M., Haker, S., Wells, W., Jolesz, F., Kikinis, R.: Statistical validation of image segmentation quality based on a spatial overlap index. Academic Radiology\u00a011(2), 178\u2013189 (2004)","journal-title":"Academic Radiology"},{"key":"25_CR19","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1007\/978-3-642-33415-3_66","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2012","author":"W. Qiu","year":"2012","unstructured":"Qiu, W., Yuan, J., Ukwatta, E., Tessier, D., Fenster, A.: Rotational-slice-based prostate segmentation using level set with shape constraint for 3D end-firing TRUS guided biopsy. In: Ayache, N., Delingette, H., Golland, P., Mori, K. (eds.) MICCAI 2012, Part I. LNCS, vol.\u00a07510, pp. 537\u2013544. Springer, Heidelberg (2012)"},{"issue":"2","key":"25_CR20","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1016\/j.media.2010.10.002","volume":"15","author":"S.S. Mahdavi","year":"2011","unstructured":"Mahdavi, S.S., Chng, N., Spadinger, I., Morris, W.J., Salcudean, S.E.: Semi-automatic segmentation for prostate interventions. Medical Image Analysis\u00a015(2), 226\u2013237 (2011)","journal-title":"Medical Image Analysis"},{"key":"25_CR21","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1118\/1.3298010","volume":"37","author":"V. Karnik","year":"2010","unstructured":"Karnik, V., Fenster, A., Bax, J., Cool, D., Gardi, L., Gyacskov, I., Romagnoli, C., Ward, A.: Assessment of image registration accuracy in three-dimensional transrectal ultrasound guided prostate biopsy. Medical physics\u00a037, 802 (2010)","journal-title":"Medical physics"},{"key":"25_CR22","doi-asserted-by":"crossref","unstructured":"Komodakis, N., Tziritas, G., Paragios, N.: Fast, approximately optimal solutions for single and dynamic MRFs. In: CVPR (2007)","DOI":"10.1109\/CVPR.2007.383095"}],"container-title":["Lecture Notes in Computer Science","Advanced Information Systems Engineering"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-40811-3_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,17]],"date-time":"2019-05-17T12:17:52Z","timestamp":1558095472000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-642-40811-3_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"ISBN":["9783642387081","9783642387098"],"references-count":22,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-40811-3_25","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2013]]}}}