{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T01:28:54Z","timestamp":1743125334667,"version":"3.40.3"},"publisher-location":"Berlin, Heidelberg","reference-count":8,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540638858"},{"type":"electronic","value":"9783642587757"}],"license":[{"start":{"date-parts":[[1998,1,1]],"date-time":"1998-01-01T00:00:00Z","timestamp":883612800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[1998,1,1]],"date-time":"1998-01-01T00:00:00Z","timestamp":883612800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1998]]},"DOI":"10.1007\/978-3-642-58775-7_15","type":"book-chapter","created":{"date-parts":[[2011,10,20]],"date-time":"2011-10-20T17:43:08Z","timestamp":1319132588000},"page":"83-87","source":"Crossref","is-referenced-by-count":1,"title":["Verbesserung der Dynamik und Ortsaufl\u00f6sung in der Ultraschalldiagnostik durch die Kombination kodierter Anregung und tiefenangepa\u00dfter Mismatched-Filterung"],"prefix":"10.1007","author":[{"given":"K.","family":"Eck","sequence":"first","affiliation":[]},{"given":"A. R.","family":"Brenner","sequence":"additional","affiliation":[]},{"given":"W.","family":"Wilhelm","sequence":"additional","affiliation":[]},{"given":"T. G.","family":"Noll","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"key":"15_CR1","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/BF02518916","volume":"32","author":"NAHK Rao","year":"1994","unstructured":"Rao NAHK: Investigation of a pulse compression technique for medical ultrasound: a simulation study. Medical & Biological Engineering & Computing, 32:181\u2013188, 1994.","journal-title":"Medical & Biological Engineering & Computing"},{"issue":"3","key":"15_CR2","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1109\/58.143168","volume":"39","author":"M O\u2019Donnell","year":"1992","unstructured":"O\u2019Donnell M: Coded excitation system for improving the penetration of real-time phased-array imaging systems. IEEE Trans. UFFC, 39(3): 341\u2013351, 1992.","journal-title":"IEEE Trans. UFFC"},{"key":"15_CR3","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1515\/bmte.1996.41.s1.170","volume":"41","author":"H Bressmer","year":"1996","unstructured":"Bressmer H, Joppek C, Pfau R, Faust U: Pulskompression in handels\u00fcblichen Ultraschall B-Bildsystemen. Biomedizinische Technik, Erg\u00e4nzungsband, 41:170\u2013171, 1996.","journal-title":"Biomedizinische Technik, Erg\u00e4nzungsband"},{"issue":"5","key":"15_CR4","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1109\/58.308500","volume":"41","author":"M Pollakowski","year":"1994","unstructured":"Pollakowski M, Ermert H: Chirp signal matching and signal power optimization in pulse-echo mode ultrasonic nondestructive testing. IEEE Trans. UFFC, 41(5): 655\u2013659, 1994.","journal-title":"IEEE Trans. UFFC"},{"key":"15_CR5","doi-asserted-by":"crossref","unstructured":"Brenner AR, Eck K, Wilhelm W, Noll TG: Improved resolution and dynamic range in medical ultrasonic imaging using depth-dependent mismatched filtering. IEEE Proc. UFFC Symp., 1997, in Druck.","DOI":"10.1007\/978-1-4419-8588-0_6"},{"issue":"8","key":"15_CR6","doi-asserted-by":"publisher","first-page":"1753","DOI":"10.1109\/78.91146","volume":"39","author":"JW Adams","year":"1991","unstructured":"Adams JW: A new optimal window. IEEE Trans. Sig. Proc, 39(8): 1753\u20131769, 1991.","journal-title":"IEEE Trans. Sig. Proc"},{"key":"15_CR7","doi-asserted-by":"crossref","unstructured":"Baldeweck T, Laugier P, Herment A, Berger G: Application of autoregressive spectral analysis for ultrasound attenuation: interest in highly attenuating medium. IEEE Proc. UFFC Symp., 1181-1186, 1993.","DOI":"10.1109\/ULTSYM.1993.339622"},{"key":"15_CR8","doi-asserted-by":"crossref","unstructured":"Wilhelm W, Noll TG: A new mapping technique for automated design of highly efficient multiplexed FIR digital filters. IEEE Proc. ISCAS, 2252-2256, 1997.","DOI":"10.1109\/ISCAS.1997.612770"}],"container-title":["Informatik aktuell","Bildverarbeitung f\u00fcr die Medizin 1998"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-642-58775-7_15","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T03:51:58Z","timestamp":1741837918000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-642-58775-7_15"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998]]},"ISBN":["9783540638858","9783642587757"],"references-count":8,"URL":"https:\/\/doi.org\/10.1007\/978-3-642-58775-7_15","relation":{},"ISSN":["1431-472X"],"issn-type":[{"type":"print","value":"1431-472X"}],"subject":[],"published":{"date-parts":[[1998]]}}}