{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,9]],"date-time":"2024-09-09T17:38:43Z","timestamp":1725903523700},"publisher-location":"Singapore","reference-count":5,"publisher":"Springer Singapore","isbn-type":[{"type":"print","value":"9789811041563"},{"type":"electronic","value":"9789811041570"}],"license":[{"start":{"date-parts":[[2017,7,8]],"date-time":"2017-07-08T00:00:00Z","timestamp":1499472000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-981-10-4157-0_26","type":"book-chapter","created":{"date-parts":[[2017,7,7]],"date-time":"2017-07-07T01:18:58Z","timestamp":1499390338000},"page":"151-155","source":"Crossref","is-referenced-by-count":0,"title":["Encountered-Type Visual Haptic Display Using MR Fluid"],"prefix":"10.1007","author":[{"given":"Hiroki","family":"Ohnari","sequence":"first","affiliation":[]},{"given":"Satoko","family":"Abiko","sequence":"additional","affiliation":[]},{"given":"Teppei","family":"Tsujita","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,7,8]]},"reference":[{"issue":"3","key":"26_CR1","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/BF00594110","volume":"7","author":"RM Satava","year":"1993","unstructured":"Satava, R.M.: Virtual reality surgical simulator. Surg. Endosc. 7(3), 203\u2013205 (1993)","journal-title":"Surg. Endosc."},{"key":"26_CR2","unstructured":"Moody, L., Baber, C., Arvanitis, T.N.: The role of haptic feedback in the training and assessment of surgeons using a virtual environment. In: Proceedings of EuroHaptics 2001, pp. 170\u2013173 (2001)"},{"key":"26_CR3","doi-asserted-by":"crossref","unstructured":"Takagi, Y., et al.: Development of haptic interface for a brain surgery simulator. In: Proceedings of the 2010 JSME Conference on Robotics and Mechatronics, 1A1-C09 (2010) (in Japanese)","DOI":"10.1299\/jsmermd.2010._1A1-C09_1"},{"issue":"7","key":"26_CR4","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1080\/01691864.2013.777013","volume":"27","author":"T Tsujita","year":"2013","unstructured":"Tsujita, T., et al.: Design and evaluation of an encountered-type haptic interface using MR fluid for surgical simulators. Adv. Robot. (AR) 27(7), 525\u2013540 (2013)","journal-title":"Adv. Robot. (AR)"},{"key":"26_CR5","doi-asserted-by":"crossref","unstructured":"Kameyama, T., et al.: Displaying cutting force of soft tissue using MR fluid for surgical simulators. In: Proceedings of the 2014 IEEE Haptics Symposium (Haptics), pp. 283\u2013288 (2014)","DOI":"10.1109\/HAPTICS.2014.6775468"}],"container-title":["Lecture Notes in Electrical Engineering","Haptic Interaction"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-981-10-4157-0_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,28]],"date-time":"2019-09-28T17:46:26Z","timestamp":1569692786000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-981-10-4157-0_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,8]]},"ISBN":["9789811041563","9789811041570"],"references-count":5,"URL":"https:\/\/doi.org\/10.1007\/978-981-10-4157-0_26","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2017,7,8]]}}}