{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T10:43:18Z","timestamp":1742985798819,"version":"3.40.3"},"publisher-location":"Singapore","reference-count":23,"publisher":"Springer Nature Singapore","isbn-type":[{"type":"print","value":"9789811667749"},{"type":"electronic","value":"9789811667756"}],"license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023]]},"DOI":"10.1007\/978-981-16-6775-6_21","type":"book-chapter","created":{"date-parts":[[2023,12,19]],"date-time":"2023-12-19T20:02:30Z","timestamp":1703016150000},"page":"255-268","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["3D-3D Rigid Registration: A Comparative Analysis Study on\u00a0Femoral Bone Scans"],"prefix":"10.1007","author":[{"given":"Perrine","family":"Solt","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adlane","family":"Habed","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antoine","family":"Bautin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Maillet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michel","family":"de Mathelin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,12,20]]},"reference":[{"key":"21_CR1","doi-asserted-by":"crossref","unstructured":"Aiger, D., Mitra, N., Cohen-Or, D.: 4-points congruent sets for robust pairwise surface registration. 35th International Conference on Computer Graphics and Interactive Techniques (SIGGRAPH\u201908) 27 (08 2008)","DOI":"10.1145\/1399504.1360684"},{"key":"21_CR2","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1109\/34.121791","volume":"14","author":"P Besl","year":"1992","unstructured":"Besl, P., McKay, H.: A method for registration of 3-D shapes. Pattern Analysis and Machine Intelligence, IEEE Transactions on 14, 239\u2013256 (1992)","journal-title":"Pattern Analysis and Machine Intelligence, IEEE Transactions on"},{"key":"21_CR3","unstructured":"Brainlab: Knee3 surgical technique p.\u00a058 (2015), https:\/\/www.brainlab.com\/wp-content\/uploads\/2016\/12\/Knee3-Surgical-Technique.pdf"},{"key":"21_CR4","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.medengphy.2020.01.012","volume":"78","author":"H Chen","year":"2020","unstructured":"Chen, H., Kluijtmans, L., Bakker, M., Dunning, H., Kang, Y., van\u00a0de Groes, S., Sprengers, A.M.J., Verdonschot, N.: A robust and semi-automatic quantitative measurement of patellofemoral instability based on four dimensional computed tomography. Medical Engineering & Physics 78, 29\u201338 ( 2020)","journal-title":"Medical Engineering & Physics"},{"key":"21_CR5","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1109\/TVCG.2012.34","volume":"18","author":"M Corsini","year":"2012","unstructured":"Corsini, M., Cignoni, P., Scopigno, R.: Efficient and Flexible Sampling with Blue Noise Properties of Triangular Meshes. IEEE transactions on visualization and computer graphics 18, 914\u201324 (2012)","journal-title":"IEEE transactions on visualization and computer graphics"},{"key":"21_CR6","doi-asserted-by":"crossref","unstructured":"Fitzpatrick, J.M.: The Role of Registration in Accurate Surgical Guidance. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 224(5), 607\u2013622 (2010)","DOI":"10.1243\/09544119JEIM589"},{"key":"21_CR7","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/j.jor.2021.01.010","volume":"23","author":"G He","year":"2021","unstructured":"He, G., Mustahsan, V.M., Bielski, M.R., Kao, I., Khan, F.A.: Report on a novel bone registration method: A rapid, accurate, and radiation-free technique for computer- and robotic-assisted orthopedic surgeries. Journal of Orthopaedics 23, 227\u2013232 (2021)","journal-title":"Journal of Orthopaedics"},{"key":"21_CR8","doi-asserted-by":"crossref","unstructured":"Hu, X., Liu, H., Rodriguez\u00a0y Baena, F.: Markerless Navigation System for Orthopaedic Knee Surgery: A Proof of Concept Study. IEEE Access 9 (Apr 2021)","DOI":"10.1109\/ACCESS.2021.3075628"},{"key":"21_CR9","doi-asserted-by":"crossref","unstructured":"Hu, X., Nguyen, A., Baena, F.R.y.: Occlusion-robust visual markerless bone tracking for computer-assisted orthopedic surgery. IEEE Transactions on Instrumentation and Measurement 71, 1\u201311 (2022)","DOI":"10.1109\/TIM.2021.3134764"},{"key":"21_CR10","doi-asserted-by":"publisher","first-page":"42010","DOI":"10.1109\/ACCESS.2020.2977072","volume":"8","author":"H Liu","year":"2020","unstructured":"Liu, H., Baena, F.R.Y.: Automatic Markerless Registration and Tracking of the Bone for Computer-Assisted Orthopaedic Surgery. IEEE Access 8, 42010\u201342020 (2020)","journal-title":"IEEE Access"},{"key":"21_CR11","unstructured":"Low, K.L.: Linear least-squares optimization for point-to-plane ICP surface registration (01 2004), https:\/\/www.comp.nus.edu.sg\/~lowkl\/publications\/lowk_point-to-plane_icp_techrep.pdf"},{"issue":"5","key":"21_CR12","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1111\/cgf.12446","volume":"33","author":"N Mellado","year":"2014","unstructured":"Mellado, N., Aiger, D., Mitra, N.J.: Super 4PCS Fast Global Pointcloud Registration via Smart Indexing. Computer Graphics Forum 33(5), 205\u2013215 (2014)","journal-title":"Computer Graphics Forum"},{"issue":"8","key":"21_CR13","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/j.jbiomech.2010.01.036","volume":"43","author":"DL Miranda","year":"2010","unstructured":"Miranda, D.L., Rainbow, M.J., Leventhal, E.L., Crisco, J.J., Fleming, B.C.: Automatic Determination of Anatomical Coordinate Systems for Three-Dimensional Bone Models of the Isolated Human Knee. Journal of biomechanics 43(8), 1623\u20131626 (2010)","journal-title":"Journal of biomechanics"},{"issue":"14","key":"21_CR14","doi-asserted-by":"publisher","first-page":"3576","DOI":"10.1016\/j.jbiomech.2016.09.005","volume":"49","author":"D Nolte","year":"2016","unstructured":"Nolte, D., Tsang, C.K., Zhang, K.Y., Ding, Z., Kedgley, A.E., Bull, A.M.: Non-linear scaling of a musculoskeletal model of the lower limb using statistical shape models. Journal of Biomechanics 49(14), 3576\u20133581 (2016)","journal-title":"Journal of Biomechanics"},{"key":"21_CR15","unstructured":"OpenGR (Aug 2022), https:\/\/github.com\/STORM-IRIT\/OpenGR, original-date: 2018-04-23T06:36:52Z"},{"key":"21_CR16","doi-asserted-by":"crossref","unstructured":"Pomerleau, F., Colas, F., Siegwart, R., Magnenat, S.: Comparing ICP variants on real-world data sets Open-source library and experimental protocol. Autonomous Robots 34(3), 133\u2013148 (2013), publisher: Springer","DOI":"10.1007\/s10514-013-9327-2"},{"issue":"6","key":"21_CR17","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1049\/htl.2019.0078","volume":"6","author":"P Rodrigues","year":"2019","unstructured":"Rodrigues, P., Antunes, M., Raposo, C., Marques, P., Fonseca, F., Barreto, J.P.: Deep segmentation leverages geometric pose estimation in computer-aided total knee arthroplasty. Healthcare Technology Letters 6(6), 226\u2013230 (2019)","journal-title":"Healthcare Technology Letters"},{"key":"21_CR18","doi-asserted-by":"crossref","unstructured":"Rusu, R.B., Cousins, S.: 3D is here: Point Cloud Library (PCL). In: IEEE International Conference on Robotics and Automation (ICRA). Shanghai, China (May 9\u201313 2011)","DOI":"10.1109\/ICRA.2011.5980567"},{"key":"21_CR19","unstructured":"Smith &Nephew: Navio surgical system, surgical technique for total knee arthroplasty p.\u00a044 (2018), https:\/\/www.smith-nephew.com\/global\/surgicaltechniques\/recon\/14529%20v1%20500095%20revc%20navio%20tka%20surgical%20technique%200718.pdf"},{"key":"21_CR20","unstructured":"Stryker: Mako\u00aepka, application user guide p. 108 (2018), https:\/\/www.strykermeded.com\/media\/2943\/mako-pka-application-user-guide-pka-30-003.pdf"},{"key":"21_CR21","doi-asserted-by":"crossref","unstructured":"Yang, J., Li, H., Campbell, D., Jia, Y.: Go-ICP: A Globally Optimal Solution to 3D ICP Point-Set Registration. IEEE Transactions on Pattern Analysis and Machine Intelligence 38(11), 2241\u20132254 (Nov 2016), arXiv:1605.03344 [cs]","DOI":"10.1109\/TPAMI.2015.2513405"},{"key":"21_CR22","unstructured":"ZimmerBiomet: Othosoft\u00ae, knee 2.4 universal p.\u00a066, https:\/\/www.zimmerbiomet.com\/content\/dam\/zimmer-biomet\/medical-professionals\/knee\/optical-navigation-system\/orthosoft-knee-2-4-universal-user-manual.pdf"},{"key":"21_CR23","unstructured":"ZimmerBiomet: Rosa\u00aeknee system, surgical technique v1.1 p.\u00a060 (2020), https:\/\/www.rosaknee.com.br\/assets\/pdfs\/ROSA%20Knee%20Surgical%20Technique%20v1.1%20(ingles).pdf"}],"container-title":["Lecture Notes in Electrical Engineering","Medical Imaging and Computer-Aided Diagnosis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-981-16-6775-6_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,4]],"date-time":"2025-03-04T18:25:50Z","timestamp":1741112750000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-981-16-6775-6_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"ISBN":["9789811667749","9789811667756"],"references-count":23,"URL":"https:\/\/doi.org\/10.1007\/978-981-16-6775-6_21","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2023]]},"assertion":[{"value":"20 December 2023","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"MICAD","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Medical Imaging and Computer-Aided Diagnosis","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2022","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"7 June 2022","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"8 June 2022","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"micad2022","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.micad.org","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}