{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T20:47:18Z","timestamp":1761252438872},"publisher-location":"Berlin, Heidelberg","reference-count":20,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540627340"},{"type":"electronic","value":"9783540684992"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1997]]},"DOI":"10.1007\/bfb0029300","type":"book-chapter","created":{"date-parts":[[2005,12,6]],"date-time":"2005-12-06T14:31:56Z","timestamp":1133879516000},"page":"747-756","source":"Crossref","is-referenced-by-count":14,"title":["A system for percutaneous delivery of treatment with a fluoroscopically-guided robot"],"prefix":"10.1007","author":[{"given":"S.","family":"Schreiner","sequence":"first","affiliation":[]},{"given":"J. H.","family":"Anderson","sequence":"additional","affiliation":[]},{"given":"R. H.","family":"Taylor","sequence":"additional","affiliation":[]},{"given":"J.","family":"Funda","sequence":"additional","affiliation":[]},{"given":"A.","family":"Bzostek","sequence":"additional","affiliation":[]},{"given":"A. C.","family":"Barnes","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2005,11,21]]},"reference":[{"key":"82_CR1","doi-asserted-by":"crossref","unstructured":"A Bzostek, et al., \u201cAn Automated System for Precise Percutaneous Access of the Renal Collecting System,\u201d presented at The First Joint Conference of CVRMed II and MRCAS Grenoble, France, 1997.","DOI":"10.1007\/BFb0029249"},{"key":"82_CR2","doi-asserted-by":"crossref","first-page":"729","DOI":"10.1056\/NEJM199109053251010","volume":"325","author":"J. R. Wands","year":"1991","unstructured":"J. R. Wands and H. E. Blum, \u201cPrimary Hepatocellular Carcinoma,\u201d The New England Journal of Medicine, vol. 325, pp. 729\u2013731, 1991.","journal-title":"The New England Journal of Medicine"},{"key":"82_CR3","first-page":"99","volume":"19","author":"S. O. Stuver","year":"1994","unstructured":"S. O. Stuver and D. Trichopoulos, \u201cLiver Cancer,\u201d Cancer Surveys, vol. 19, pp 99\u2013124 1994.","journal-title":"Cancer Surveys"},{"key":"82_CR4","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3322\/canjclin.44.1.7","volume":"44","author":"C. C. Boring","year":"1994","unstructured":"C. C. Boring, et al., \u201cCancer Statistics, 1994,\u201d Cancer Journal for Clinicians, vol 44 pp 7\u201326, 1994.","journal-title":"Cancer Journal for Clinicians"},{"key":"82_CR5","first-page":"255","volume-title":"Minimally Invasive Surgery","author":"P. D. Schneider","year":"1993","unstructured":"P. D. Schneider and J. P. McGahan, \u201cPercutaneous Approaches to Liver Neoplasms,\u201d in Minimally Invasive Surgery, J. G. Hunter and J. Sackier, Eds. New York: McGraw Hill, 1993, pp. 255\u2013263."},{"key":"82_CR6","first-page":"1313","volume":"168","author":"T. Levraghi","year":"1988","unstructured":"T. Levraghi, A. Salmi, and L. Bolondi, \u201cSmall hepatocellular carcinoma: percutaneous alcohol injection \u2014 results in 23 patients,\u201d Radiology, vol. 168, pp. 1313\u20131317, 1988.","journal-title":"Radiology"},{"key":"82_CR7","first-page":"231","volume":"54","author":"R. Holt","year":"1988","unstructured":"R. Holt, R. Naunta, and T. Lee, \u201cIntraoperative interstitial radiation therapy for hepatic metastases from colorectal carcinomas,\u201d Amer. J. of Surgery, vol. 54, pp. 231\u2013233, 1988.","journal-title":"Amer. J. of Surgery"},{"key":"82_CR8","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1002\/lsm.1900100403","volume":"10","author":"J. Hahl","year":"1990","unstructured":"J. Hahl, R. Haapiainen, and J. Ovaska, \u201cLaser-induced hyperthermia in the treatment of liver tumors,\u201d Lasers Surg Med, vol. 10, pp. 319\u2013321, 1990.","journal-title":"Lasers Surg Med"},{"key":"82_CR9","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1097\/00004424-199003000-00011","volume":"25","author":"J. McGahan","year":"1990","unstructured":"J. McGahan, P. Browning, and J. Brock, \u201cHepatic ablation using radiofrequency electrocautery,\u201d Investigational Radiology, vol. 25, pp. 267\u2013270, 1990.","journal-title":"Investigational Radiology"},{"key":"82_CR10","unstructured":"J. H. Anderson, et al., \u201cImage-Guided Percutaneous Robotic Assisted Therapy,\u201d presented at Annual Fall Meeting of the Biomedical Engineering Society, The Pennsylvania State University, 1996."},{"key":"82_CR11","volume-title":"Medical Physics Monograph No. 20","author":"J. A. Seibert","year":"1991","unstructured":"J. A. Seibert, G. T. Barnes, and R. G. Gould, \u201cSpecification, Acceptance Testing and Quality Control of Diagnostic X-ray Imaging Equipment,\u201d in Medical Physics Monograph No. 20. Woodbury, NY: American Institute of Physics, Inc., 1991."},{"key":"82_CR12","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1118\/1.596718","volume":"18","author":"J. M. Boone","year":"1991","unstructured":"J. M. Boone, et al., \u201cAnalysis and correction of imperfections in the image intensifier-TV-digitizer imaging chain,\u201d Medical Physics, vol. 18, pp. 236\u2013242, 1991.","journal-title":"Medical Physics"},{"key":"82_CR13","doi-asserted-by":"crossref","unstructured":"B. Schueler and X. Hu, \u201cCorrection of image intensifier distortion for three-dimensional x-ray angiography,\u201d presented at SPIE Medical Imaging 1995 \u2014 Physics of Medical Imaging, San Diego, CA, 1995.","DOI":"10.1117\/12.208345"},{"key":"82_CR14","doi-asserted-by":"crossref","unstructured":"S. Schreiner, et al., \u201cAccuracy Assessment of a clinical biplane fluoroscope for three-dimensional measurements and targeting,\u201d presented at SPIE Conference on Medical Imaging, Newport Beach, CA, 1997.","DOI":"10.1117\/12.273892"},{"key":"82_CR15","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/0895-6111(93)90020-N","volume":"17","author":"A. Rougee","year":"1993","unstructured":"A. Rougee, et al., \u201cGeometrical Calibration of X-ray Imaging Chains for Three-Dimensional Reconstruction,\u201d Computerized Medical Imaging and Graphics, vol. 17, pp. 295\u2013300, 1993.","journal-title":"Computerized Medical Imaging and Graphics"},{"key":"82_CR16","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1109\/JRA.1987.1087109","volume":"3","author":"R. Y. Tsai","year":"1987","unstructured":"R. Y. Tsai, \u201cA versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses,\u201d IEEE Transactions on Robotics and Automation, vol. 3, pp. 323\u2013344, 1987.","journal-title":"IEEE Transactions on Robotics and Automation"},{"key":"82_CR17","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1109\/70.34770","volume":"5","author":"R. Y. Tsai","year":"1989","unstructured":"R. Y. Tsai and R. K. Lenz, \u201cA new technique for fully autonomous and efficient 3D robotics hand\/eye calibration,\u201d IEEE Trans. on Robotics and Automation, vol. 5, pp. 345\u2013358, 1989.","journal-title":"IEEE Trans. on Robotics and Automation"},{"key":"82_CR18","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/978-3-642-83413-4_10","volume-title":"Medical Radiology Innovations in Diagnostic Radiology","author":"W. C. Hunter","year":"1989","unstructured":"W. C. Hunter and E. A. Zerhouni, \u201cImaging Distinct Points in Left Ventricular Myocardium to Study Regional Wall Deformation,\u201d in Medical Radiology Innovations in Diagnostic Radiology, J. H. Anderson, Ed. Berlin, Germany: Springer-Verlag, 1989, pp. 169\u2013190."},{"key":"82_CR19","doi-asserted-by":"crossref","unstructured":"P. Potamianos, B.L. Davies, and R.D. Hibbard, \u201cIntra-operative Registration for Percutaneous Surgery,\u201d Proceedings of the 2nd Annual Symposium on MRCAS, Baltimore, MD, pp.156\u2013164, 1995.","DOI":"10.1016\/S1071-0949(95)80005-0"},{"key":"82_CR20","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1109\/51.391776","volume":"14","author":"R. H. Taylor","year":"1995","unstructured":"R. H. Taylor, et. al, \u201cA Telerobotic Assistant for Laparoscopic Surgery,\u201d IEEE Engineering in Medicine and Biology Magazine, vol. 14, pp. 279\u2013287, 1995.","journal-title":"IEEE Engineering in Medicine and Biology Magazine"}],"container-title":["Lecture Notes in Computer Science","CVRMed-MRCAS'97"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BFb0029300","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,11]],"date-time":"2020-04-11T11:15:41Z","timestamp":1586603741000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BFb0029300"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1997]]},"ISBN":["9783540627340","9783540684992"],"references-count":20,"URL":"https:\/\/doi.org\/10.1007\/bfb0029300","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[1997]]}}}