{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T16:58:11Z","timestamp":1760029091872,"version":"3.40.3"},"publisher-location":"Berlin, Heidelberg","reference-count":16,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540651369"},{"type":"electronic","value":"9783540495635"}],"license":[{"start":{"date-parts":[[1998,1,1]],"date-time":"1998-01-01T00:00:00Z","timestamp":883612800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1998]]},"DOI":"10.1007\/bfb0056197","type":"book-chapter","created":{"date-parts":[[2006,8,17]],"date-time":"2006-08-17T14:02:49Z","timestamp":1155823369000},"page":"146-155","source":"Crossref","is-referenced-by-count":8,"title":["3-D fusion of biplane angiography and intravascular ultrasound for accurate visualization and volumetry"],"prefix":"10.1007","author":[{"given":"Andreas","family":"Wahle","sequence":"first","affiliation":[]},{"given":"Guido P. M.","family":"Prause","sequence":"additional","affiliation":[]},{"given":"Steven C.","family":"DeJong","sequence":"additional","affiliation":[]},{"given":"Milan","family":"Sonka","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2006,6,1]]},"reference":[{"key":"16_CR1","first-page":"215","volume-title":"Automated evaluation of vessel diameter from arteriograms","author":"R. L. Kirkeeide","year":"1982","unstructured":"Kirkeeide R. L., Fung P., Smalling R. W., and Gould K. L., Automated evaluation of vessel diameter from arteriograms, in: Proc. Computers in Cardiology 1982, Seattle WA. IEEE-CS Press, Los Alamitos CA (1982) 215\u2013218."},{"key":"16_CR2","first-page":"721","volume-title":"Computer Assisted Radiology (CAR \u201991)","author":"J. Beier","year":"1991","unstructured":"Beier J., Oswald H., Sauer H. U., and Fleck E., Accuracy of measurement in quantitative coronary angiography (QCA), in: Lemke H. U., Rhodes M. L., Jaffe C. C., and Felix R. (eds.), Computer Assisted Radiology (CAR \u201991). Springer, Berlin\/New York (1991) 721\u2013726."},{"key":"16_CR3","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1109\/42.370412","volume":"14","author":"M. Sonka","year":"1995","unstructured":"Sonka M., Winniford M. D., and Collins S. M., Robust simultaneous detection of coronary borders in complex images. IEEE Transactions on Medical Imaging 14 (1995) 151\u2013161.","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"16_CR4","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1088\/0031-9155\/36\/1\/009","volume":"36","author":"N. Guggenheim","year":"1991","unstructured":"Guggenheim N., Doriot P. A., Dorsaz P. A., Descouts P., and Rutishauser W., Spatial reconstruction of coronary arteries from angiographic images. Physics in Medicine and Biology 36 (1991) 99\u2013110.","journal-title":"Physics in Medicine and Biology"},{"key":"16_CR5","doi-asserted-by":"publisher","first-page":"1987","DOI":"10.1161\/01.CIR.85.6.1987","volume":"85","author":"C. Seiler","year":"1992","unstructured":"Seiler C., Kirkeeide R. L., and Gould K. L., Basic structure-function relations of the epicardial coronary vascular tree; basis of quantitative coronary arteriography for diffuse coronary artery disease. Circulation 85 (1992) 1987\u20132003.","journal-title":"Circulation"},{"key":"16_CR6","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1109\/42.387704","volume":"14","author":"A. Wahle","year":"1995","unstructured":"Wahle A., Wellnhofer E., Mugaragu I., Sauer H. U., Oswald H., and Fleck E., Assessment of diffuse coronary artery disease by quantitative analysis of coronary morphology based upon 3-D reconstruction from biplane angiograms. IEEE Transactions on Medical Imaging 14 (1995) 230\u2013241.","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"16_CR7","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1109\/42.476113","volume":"14","author":"M. Sonka","year":"1995","unstructured":"Sonka M., Zhang X., Siebes M., Bissing M. S., DeJong S. C., Collins S. M., and McKay C. R., Segmentation of intravascular ultrasound images: A knowledge-based approach. IEEE Transactions on Medical Imaging 14 (1995) 719\u2013732.","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"16_CR8","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/978-94-011-5123-8_5","volume-title":"What\u2019s New in Cardiovascular Imaging? Vol. 204 of Developments in Cardiovascular Medicine","author":"J. Dijkstra","year":"1998","unstructured":"Dijkstra J., Wahle A., Koning G., Reiber J. H. C., and Sonka M., Quantitative coronary ultrasound: State of the art, in: Reiber J. H. C. and van der Wall E. E. (eds.), What\u2019s New in Cardiovascular Imaging? Vol. 204 of Developments in Cardiovascular Medicine, Kluwer, Dordrecht (1998) 79\u201394."},{"key":"16_CR9","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/978-94-011-5123-8_14","volume-title":"What\u2019s New in Cardiovascular Imaging? Vol. 204 of Developments in Cardiovascular Medicine","author":"M. Sonka","year":"1998","unstructured":"Sonka M. and Zhang X., Assessment of plaque composition using intravascular ultrasound; in: Reiber J. H. C. and van der Wall E. E. (eds.), What\u2019s New in Cardiovascular Imaging? Vol. 204 of Developments in Cardiovascular Medicine, Kluwer, Dordrecht (1998) 183\u2013196."},{"key":"16_CR10","first-page":"325","volume-title":"ANGUS: A new approach to three-dimensional reconstruction of coronary vessels by combined use of angiography and intravascular ultrasound","author":"M. Laban","year":"1995","unstructured":"Laban M., Oomen J. A., Slager C. J., Wentzel J. J., Krams R., Schuurbiers J. C. H., den Boer A., von Birgelen C., Serruys P. W., and de Feyter P. J., ANGUS: A new approach to three-dimensional reconstruction of coronary vessels by combined use of angiography and intravascular ultrasound, in: Proc. Computers in Cardiology 1995, Vienna AT. IEEE Press, Piscataway NJ (1995) 325\u2013328."},{"key":"16_CR11","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1161\/01.CIR.93.3.567","volume":"93","author":"J. L. Evans","year":"1996","unstructured":"Evans J. L., Ng K. H., Wiet S. G., Vonesh M. J., Burns W. B., Radvany M. G., Kane B. J., Davidson C. J., Roth S. I., Kramer B. L., Meyers S. N., and McPherson D. D., Accurate three-dimensional reconstruction of intravascular ultrasound data; spatially correct three-dimensional reconstructions. Circulation 93 (1996) 567\u2013576.","journal-title":"Circulation"},{"key":"16_CR12","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1023\/A:1005843222820","volume":"13","author":"G. P. M. Prause","year":"1997","unstructured":"Prause G. P. M., DeJong S. C., McKay C. R., and Sonka M., Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound. International Journal of Cardiac Imaging 13 (1997) 451\u2013462.","journal-title":"International Journal of Cardiac Imaging"},{"key":"16_CR13","first-page":"82","volume-title":"Semi-automated segmentation and 3-D reconstruction of coronary trees: Biplane angiography and intravascular ultrasound data fusion","author":"G. P. M. Prause","year":"1996","unstructured":"Prause G. P. M., DeJong S. C., McKay C. R., and Sonka M., Semi-automated segmentation and 3-D reconstruction of coronary trees: Biplane angiography and intravascular ultrasound data fusion, in: Proc. Medical Imaging 1996: Physiology and Function from Multidimensional Images, Newport Beach CA. Vol. 2709, SPIE, Bellingham WA (1996) 82\u201392."},{"key":"16_CR14","first-page":"504","volume-title":"3-D catheter path reconstruction from biplane angiograms","author":"C. Molina","year":"1998","unstructured":"Molina C., Prause G. P. M., Radeva P., and Sonka M., 3-D catheter path reconstruction from biplane angiograms, in: Proc. Medical Imaging 1998: Image Processing, San Diego CA. Vol. 3338, SPIE, Bellingham WA (1998) 504\u2013512."},{"key":"16_CR15","volume-title":"Reihe Biotechnik (17)","author":"A. Wahle","year":"1997","unstructured":"Wahle A., Pr\u00e4zise dreidimensionale Rekonstruktion von Gef\u00e4\\systemen aus biplanen angiographischen Projektionen und deren klinische Anwendung. No. 152 in Fortschritt-Berichte, Reihe Biotechnik (17), VDI Verlag, D\u00fcsseldorf (1997)."},{"key":"16_CR16","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/0010-4809(87)90043-7","volume":"20","author":"D. L. Parker","year":"1987","unstructured":"Parker D. L., Pope D. L., van Bree R. E., and Marshall H. W., Three-dimensional reconstruction of moving arterial beds from digital subtraction angiography. Computers and Biomedical Research 20 (1987) 166\u2013185.","journal-title":"Computers and Biomedical Research"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2014 MICCAI\u201998"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BFb0056197","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,2,11]],"date-time":"2019-02-11T20:51:24Z","timestamp":1549918284000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BFb0056197"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998]]},"ISBN":["9783540651369","9783540495635"],"references-count":16,"URL":"https:\/\/doi.org\/10.1007\/bfb0056197","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[1998]]}}}