{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T20:47:49Z","timestamp":1761252469603,"version":"3.40.3"},"publisher-location":"Berlin, Heidelberg","reference-count":21,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540651369"},{"type":"electronic","value":"9783540495635"}],"license":[{"start":{"date-parts":[[1998,1,1]],"date-time":"1998-01-01T00:00:00Z","timestamp":883612800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1998]]},"DOI":"10.1007\/bfb0056299","type":"book-chapter","created":{"date-parts":[[2006,8,17]],"date-time":"2006-08-17T14:02:49Z","timestamp":1155823369000},"page":"1099-1106","source":"Crossref","is-referenced-by-count":48,"title":["Non-rigid multimodal image registration using mutual information"],"prefix":"10.1007","author":[{"given":"Tom","family":"Gaens","sequence":"first","affiliation":[]},{"given":"Frederik","family":"Maes","sequence":"additional","affiliation":[]},{"given":"Dirk","family":"Vandermeulen","sequence":"additional","affiliation":[]},{"given":"Paul","family":"Suetens","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2006,6,1]]},"reference":[{"key":"118_CR1","doi-asserted-by":"crossref","unstructured":"R. Bajcsy and S. Kovacic, Multiresolution elastic matching, Computer Vision, Graphics, and Image Processing, 46:1\u201321, Academic Press, 1989.","DOI":"10.1016\/S0734-189X(89)80014-3"},{"key":"118_CR2","doi-asserted-by":"crossref","unstructured":"F.L. Bookstein, Morphometric tools for landmark data. Geometry and biology, Cambridge University Press, 1991.","DOI":"10.1017\/CBO9780511573064"},{"key":"118_CR3","unstructured":"C. Broit, Optimal registration of deformed images, PhD thesis, University of Pennsylvania, August 1981"},{"key":"118_CR4","first-page":"267","volume":"1131","author":"M. Bro-Nielsen","year":"1996","unstructured":"M. Bro-Nielsen and C. Gramkow, Fast fluid registration of medical images, in Proc. Visualization in Biomedical Computing (VBC\u201996), Springer Lecture Notes in Computer Science, 1131:267\u2013276, September 1996.","journal-title":"Springer Lecture Notes in Computer Science"},{"key":"118_CR5","first-page":"3","volume":"1205","author":"M. Bro-Nielsen","year":"1997","unstructured":"M. Bro-Nielsen, C. Gramkow, and S. Kreiborg, Non-rigid image registration using bone growth model, in Proc. CVRMed\/MRCAS\u201997, Springer Lecture Notes in Computer Science, 1205:3\u201312, 1997.","journal-title":"Springer Lecture Notes in Computer Science"},{"issue":"6","key":"118_CR6","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1109\/TPAMI.1981.4767176","volume":"3","author":"D.J. Burr","year":"1981","unstructured":"D.J. Burr, Elastic Matching of Line Drawings, IEEE Trans. on PAMI, 3(6):708\u2013713, November 1981","journal-title":"IEEE Trans. on PAMI"},{"key":"118_CR7","unstructured":"G.E. Christensen, Deformable shape models for anatomy, PhD thesis, Washington University, Sever Institute of Technology, 1994."},{"key":"118_CR8","unstructured":"A. Collignon, F. Maes, D. Delaere, D. Vandermeulen, P. Suetens, and G. Marchal, Automated multimodality medical image registration using information theory, in Y. Bizais, C. Barillot, and R. Di Paola (Eds.), Proc. XIV\u2019th Int. Conf. Information Processing in Medical Imaging, Computational Imaging and Vision 3, pp. 263\u2013274, Kluwer Academic Publishers, June 1995."},{"key":"118_CR9","unstructured":"A. Collignon, Multi-modality medical image registration by maximization of mutual information, PhD thesis, K.U. Leuven, 1998"},{"key":"118_CR10","unstructured":"D.L. Collins, 3D Model-based segmentation of individual brain structures from magnetic resonance imaging data, PhD thesis, McGill University, 1994."},{"key":"118_CR11","doi-asserted-by":"crossref","unstructured":"T.M. Cover and J.A. Thomas, Elements of Information Theory, John Wiley & Sons, 1991.","DOI":"10.1002\/0471200611"},{"key":"118_CR12","unstructured":"T. Gaens, S. Sagaert, D. Vandermeulen, Non-rigid registration using mutual information, ESAT\/PSI Technical Report nr. 97\/10, 1997."},{"key":"118_CR13","unstructured":"H. Lester, S. Arridge, Summarising fluid registration by thin-plate spline warps with many landmarks, in Proceedings of Medical Image Understanding and Analysis 1997, Oxford, July 1997."},{"issue":"2","key":"118_CR14","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1109\/42.563664","volume":"16","author":"F. Maes","year":"1997","unstructured":"F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens, Multi-Modality Image Registration by Maximization of Mutual Information, IEEE Trans. on Medical Imaging, 16(2): 187\u2013198, April 1997.","journal-title":"IEEE Trans. on Medical Imaging"},{"key":"118_CR15","doi-asserted-by":"crossref","unstructured":"D. McGarry, T. Jackson, M. Plantec, N. Kassell, J.H. Downs, Registration of functional magnetic resonance imagery using mutual information, Proc. SPIE Medical Imaging 1997, pp. 621\u2013630.","DOI":"10.1117\/12.274148"},{"issue":"3","key":"118_CR16","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/S1361-8415(97)85010-4","volume":"1","author":"C. Meyer","year":"1997","unstructured":"C. Meyer, J. Boes, B. Kim, P. Bland, K. Zasadny, P. Kison, K. Koral, K. Frey, R. Wahl, Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations, Medical Image Analysis, 1(3):195\u2013206, April 1997.","journal-title":"Medical Image Analysis"},{"key":"118_CR17","doi-asserted-by":"crossref","unstructured":"J.B. Maintz, E. Meijering, M. Viergever, General multimodal elastic registration based on mutual information, to appear in Proc. SPIE Med. Imaging, 1998.","DOI":"10.1117\/12.310845"},{"key":"118_CR18","unstructured":"C. Maurer, and J. Fitzpatrick, A review of medical image registration, in R. Maciunas (Ed.), Interactive Image-guided Neurosurgery, pp. 17\u201344, American Association of Neurological Surgeons, 1993."},{"key":"118_CR19","doi-asserted-by":"crossref","unstructured":"J.-P. Thirion, Fast non-rigid matching of 3D medical images, INRIA Technical Report, nr. 2547, May 1995.","DOI":"10.1109\/CVPR.1996.517081"},{"key":"118_CR20","doi-asserted-by":"crossref","unstructured":"P. van den Elsen, E.-J. Pol, and M. Viergever, Medical image matching \u2014 a review with classification, IEEE Eng. in Medicine and Biology, pp. 26\u201338, March 1993.","DOI":"10.1109\/51.195938"},{"issue":"1","key":"118_CR21","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/S1361-8415(01)80004-9","volume":"1","author":"P. Viola","year":"1996","unstructured":"P. Viola and W.M. et al. Wells III, Multi-modal volume registration by maximization of mutual information, Medical Image Analysis, 1(1):35\u201351, March 1996.","journal-title":"Medical Image Analysis"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2014 MICCAI\u201998"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/BFb0056299","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,20]],"date-time":"2019-04-20T14:45:32Z","timestamp":1555771532000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/BFb0056299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998]]},"ISBN":["9783540651369","9783540495635"],"references-count":21,"URL":"https:\/\/doi.org\/10.1007\/bfb0056299","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[1998]]}}}