{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T21:13:50Z","timestamp":1762377230829,"version":"3.37.3"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"FONDECYT","award":["1180832"],"award-info":[{"award-number":["1180832"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Engineering with Computers"],"published-print":{"date-parts":[[2022,10]]},"DOI":"10.1007\/s00366-022-01738-y","type":"journal-article","created":{"date-parts":[[2022,10,2]],"date-time":"2022-10-02T17:02:26Z","timestamp":1664730146000},"page":"4043-4060","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Mechanics-informed snakes isogeometric analysis (MISIGA): an image-based method for the estimation of local deformation and strain in blood vessels"],"prefix":"10.1007","volume":"38","author":[{"given":"Agust\u00edn","family":"Cox","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Ortiz-Puerta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julio","family":"Sotelo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergio","family":"Uribe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6261-9106","authenticated-orcid":false,"given":"Daniel E.","family":"Hurtado","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,10,2]]},"reference":[{"issue":"3","key":"1738_CR1","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1177\/1358863X16629727","volume":"21","author":"NC Batagini","year":"2016","unstructured":"Batagini NC, Ventura CAP, Raghavan ML, Chammas MC, Tachibana A, Da Silva ES (2016) Volumetry and biomechanical parameters detected by 3d and 2d ultrasound in patients with and without an abdominal aortic aneurysm. Vasc Deformation 21(3):209\u2013216. https:\/\/doi.org\/10.1177\/1358863X16629727","journal-title":"Vasc Deformation"},{"issue":"6","key":"1738_CR2","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.114.001536","volume":"3","author":"V Bell","year":"2014","unstructured":"Bell V, Mitchell WA, Sigur\u00f0sson S, Westenberg JJ, Gotal JD, Torjesen AA, Aspelund T, Launer LJ, de Roos A, Gudnason V, Harris TB, Mitchell GF, (2014) Longitudinal and circumferential strain of the proximal aorta. J Am Heart Assoc 3(6):e001536. https:\/\/doi.org\/10.1161\/JAHA.114.001536","journal-title":"J Am Heart Assoc"},{"key":"1738_CR3","doi-asserted-by":"publisher","first-page":"113666","DOI":"10.1016\/j.cma.2021.113666","volume":"70","author":"M Bucelli","year":"2021","unstructured":"Bucelli M, Salvador M, Dede\u2019 L, Quarteroni A (2021) Multipatch isogeometric analysis for electrophysiology: Simulation in a human heart. Comput Methods Appl Mech Eng 70:113666. https:\/\/doi.org\/10.1016\/j.cma.2021.113666","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"3","key":"1738_CR4","doi-asserted-by":"publisher","first-page":"163","DOI":"10.18383\/j.tom.2017.00015","volume":"3","author":"NS Burris","year":"2017","unstructured":"Burris NS, Hoff BA, Kazerooni EA, Ross BD (2017) Vascular deformation mapping (vdm) of thoracic aortic enlargement in aneurysmal disease and dissection. Tomography 3(3):163\u2013173. https:\/\/doi.org\/10.18383\/j.tom.2017.00015","journal-title":"Tomography"},{"key":"1738_CR5","doi-asserted-by":"publisher","first-page":"S123","DOI":"10.21037\/atm.2018.12.16","volume":"6","author":"NS Burris","year":"2018","unstructured":"Burris NS, Hoff BA, Ross BD (2018) Vascular deformation mapping (VDM) of thoracic aortic aneurysm: an application for color 3d printing in aortic disease. Ann Transl Med 6:S123. https:\/\/doi.org\/10.21037\/atm.2018.12.16","journal-title":"Ann Transl Med"},{"issue":"1","key":"1738_CR6","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.pcad.2013.05.007","volume":"56","author":"KH Chau","year":"2013","unstructured":"Chau KH, Elefteriades JA (2013) Natural history of thoracic aortic aneurysms: size matters, plus moving beyond size. Prog Cardiovasc Dis 56(1):74\u201380. https:\/\/doi.org\/10.1016\/j.pcad.2013.05.007","journal-title":"Prog Cardiovasc Dis"},{"issue":"1","key":"1738_CR7","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1177\/016173460502700102","volume":"27","author":"X Chen","year":"2005","unstructured":"Chen X, Xie H, Erkamp R, Kim K, Jia C, Rubin JM, O\u2019Donnell M (2005) 3-d correlation-based speckle tracking. Ultrason Imaging 27(1):21\u201336. https:\/\/doi.org\/10.1177\/016173460502700102","journal-title":"Ultrason Imaging"},{"key":"1738_CR8","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.cma.2014.04.015","volume":"277","author":"L Chen","year":"2014","unstructured":"Chen L, Nguyen-Thanh N, Nguyen-Xuan H, Rabczuk T, Bordas SPA, Limbert G (2014) Explicit finite deformation analysis of isogeometric membranes. Comput Methods Appl Mech Eng 277:104\u2013130. https:\/\/doi.org\/10.1016\/j.cma.2014.04.015","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"2","key":"1738_CR9","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ejvs.2016.11.018","volume":"53","author":"HW de Beaufort","year":"2017","unstructured":"de Beaufort HW, Nauta FJ, Conti M, Cellitti E, Trentin C, Faggiano E, van Bogerijen GH, Figueroa CA, Moll FL, van Herwaarden JA, Auricchio F, Trimarchi S (2017) Extensibility and distensibility of the thoracic aorta in patients with aneurysm. Eur J Vasc Endovasc Surg 53(2):199\u2013205. https:\/\/doi.org\/10.1016\/j.ejvs.2016.11.018","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"2","key":"1738_CR10","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.ejvs.2015.07.042","volume":"51","author":"W Derwich","year":"2016","unstructured":"Derwich W, Wittek A, Pfister K, Nelson K, Bereiter-Hahn J, Fritzen CP, Blase C, Schmitz-Rixen T (2016) High resolution strain analysis comparing aorta and abdominal aortic aneurysm with real time three dimensional speckle tracking ultrasound. Eur J Vasc Endovasc Surg 51(2):187\u2013193. https:\/\/doi.org\/10.1016\/j.ejvs.2015.07.042","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"2","key":"1738_CR11","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1002\/mrm.20137","volume":"52","author":"MT Draney","year":"2004","unstructured":"Draney MT, Arko FR, Alley MT, Markl M, Herfkens RJ, Pelc NJ, Zarins CK, Taylor CA (2004) Quantification of vessel wall motion and cyclic strain using cine phase contrast mri: In vivo validation in the porcine aorta. Magn Reson Med 52(2):286\u2013295. https:\/\/doi.org\/10.1002\/mrm.20137","journal-title":"Magn Reson Med"},{"issue":"5","key":"1738_CR12","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.cpcardiol.2008.01.004","volume":"33","author":"JA Elefteriades","year":"2008","unstructured":"Elefteriades JA (2008) Thoracic aortic aneurysm: reading the enemy\u2019s playbook. Curr Probl Cardiol 33(5):203\u2013277. https:\/\/doi.org\/10.1016\/j.cpcardiol.2008.01.004","journal-title":"Curr Probl Cardiol"},{"key":"1738_CR13","unstructured":"Gao X, Loriot S, Tagliasacchi A (2020) Triangulated surface mesh skeletonization. In: CGAL user and reference manual, 5.1 edn. CGAL Editorial Board. https:\/\/doc.cgal.org\/5.1\/Manual\/packages.html"},{"issue":"5","key":"1738_CR14","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1001\/jama.2009.54","volume":"301","author":"J Hausleiter","year":"2009","unstructured":"Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, McCollough C, Martinoff S, Kastrati A, Sch\u00f6mig A, Achenbach S (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500\u2013507. https:\/\/doi.org\/10.1001\/jama.2009.54","journal-title":"JAMA"},{"key":"1738_CR15","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1016\/j.ejvs.2007.11.019","volume":"35","author":"LL Hoornweg","year":"2008","unstructured":"Hoornweg LL, Storm-Versloot MN, Ubbink DT, Koelemay MJW, Legemate DA, Balm R (2008) Meta analysis on mortality of ruptured abdominal aortic aneurysms. Eur J Vasc Endovasc Surg 35:558\u2013570. https:\/\/doi.org\/10.1016\/j.ejvs.2007.11.019","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"1\u20133","key":"1738_CR16","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/0004-3702(81)90024-2","volume":"17","author":"BKP Horn","year":"1981","unstructured":"Horn BKP, Schunck BG (1981) Determining optical flow. Artif Intell 17(1\u20133):185\u2013203. https:\/\/doi.org\/10.1016\/0004-3702(81)90024-2","journal-title":"Artif Intell"},{"issue":"39\u201341","key":"1738_CR17","doi-asserted-by":"publisher","first-page":"4135","DOI":"10.1016\/j.cma.2004.10.008","volume":"194","author":"TJ Hughes","year":"2005","unstructured":"Hughes TJ, Cottrell JA, Bazilevs Y (2005) Isogeometric analysis: cad, finite elements, nurbs, exact geometry and mesh refinement. Comput Methods Appl Mech Eng 194(39\u201341):4135\u20134195","journal-title":"Comput Methods Appl Mech Eng"},{"key":"1738_CR18","doi-asserted-by":"publisher","first-page":"113764","DOI":"10.1016\/j.cma.2021.113764","volume":"379","author":"DE Hurtado","year":"2021","unstructured":"Hurtado DE, Zavala P (2021) Accelerating cardiac and vessel mechanics simulations\u202f: an energy-transform variational formulation for soft-tissue hyperelasticity. Comput Methods Appl Mech Eng 379:113764. https:\/\/doi.org\/10.1016\/j.cma.2021.113764","journal-title":"Comput Methods Appl Mech Eng"},{"key":"1738_CR19","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.3389\/fphys.2018.01513","volume":"9","author":"J Jilberto","year":"2018","unstructured":"Jilberto J, Hurtado DE (2018) Semi-implicit non-conforming finite-element schemes for cardiac electrophysiology: a framework for mesh-coarsening heart simulations. Front Physiol 9:1513. https:\/\/doi.org\/10.3389\/fphys.2018.01513","journal-title":"Front Physiol"},{"issue":"6","key":"1738_CR20","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1016\/S0741-5214(95)70227-X","volume":"21","author":"G Johansson","year":"1995","unstructured":"Johansson G, Markstr\u00f6m U, Swedenborg J (1995) Ruptured thoracic aortic aneurysms: a study of incidence and mortality rates. J Vasc Surg 21(6):985\u2013988. https:\/\/doi.org\/10.1016\/S0741-5214(95)70227-X","journal-title":"J Vasc Surg"},{"issue":"7","key":"1738_CR21","doi-asserted-by":"publisher","first-page":"1518","DOI":"10.1016\/j.camwa.2015.04.004","volume":"70","author":"M Kapl","year":"2015","unstructured":"Kapl M, Vitrih V, J\u00fcttler B, Birner K (2015) Isogeometric analysis with geometrically continuous functions on two-patch geometries. Comput Math Appl 70(7):1518\u20131538. https:\/\/doi.org\/10.1016\/j.camwa.2015.04.004","journal-title":"Comput Math Appl"},{"issue":"5","key":"1738_CR22","doi-asserted-by":"publisher","first-page":"1664","DOI":"10.1016\/j.athoracsur.2013.06.037","volume":"96","author":"K Karatolios","year":"2013","unstructured":"Karatolios K, Wittek A, Nwe TH, Bihari P, Shelke A, Josef D, Schmitz-Rixen T, Geks J, Maisch B, Blase C, Moosdorf R, Vogt S (2013) Method for aortic wall strain measurement with three-dimensional ultrasound speckle tracking and fitted finite element analysis. Ann Thorac Surg 96(5):1664\u20131671. https:\/\/doi.org\/10.1016\/j.athoracsur.2013.06.037","journal-title":"Ann Thorac Surg"},{"issue":"4","key":"1738_CR23","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/BF00133570","volume":"1","author":"M Kass","year":"1988","unstructured":"Kass M, Witkin A, Terzopoulos D (1988) Snakes: active contour models. Int J Comput Vis 1(4):321\u2013331","journal-title":"Int J Comput Vis"},{"issue":"49\u201352","key":"1738_CR24","doi-asserted-by":"publisher","first-page":"3902","DOI":"10.1016\/j.cma.2009.08.013","volume":"198","author":"J Kiendl","year":"2009","unstructured":"Kiendl J, Bletzinger KU, W\u00fcchner R (2009) Isogeometric shell analysis with Kirchhoff-love elements. Comput Methods Appl Mech Eng 198(49\u201352):3902\u20133914. https:\/\/doi.org\/10.1016\/j.cma.2009.08.013","journal-title":"Comput Methods Appl Mech Eng"},{"key":"1738_CR25","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.cma.2015.03.010","volume":"291","author":"J Kiendl","year":"2015","unstructured":"Kiendl J, Hsu MC, Wu MC, Reali A (2015) Isogeometric Kirchhoff-love shell formulations for general hyperelastic materials. Comput Methods Appl Mech Eng 291:280\u2013303. https:\/\/doi.org\/10.1016\/j.cma.2015.03.010","journal-title":"Comput Methods Appl Mech Eng"},{"key":"1738_CR26","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1016\/j.cma.2019.05.025","volume":"354","author":"L Leonetti","year":"2019","unstructured":"Leonetti L, Magisano D, Madeo A, Garcea G, Kiendl J, Reali A (2019) A simplified Kirchhoff-love large deformation model for elastic shells and its effective isogeometric formulation. Comput Methods Appl Mech Eng 354:369\u2013396. https:\/\/doi.org\/10.1016\/j.cma.2019.05.025","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"12","key":"1738_CR27","doi-asserted-by":"publisher","first-page":"2619","DOI":"10.1002\/jum.15651","volume":"40","author":"T Li","year":"2021","unstructured":"Li T, Liu X, Sun H, Ning H, Yang J, Ma C (2021) Assessment of the global and regional circumferential strain of abdominal aortic aneurysm with different size by speckle-tracking echocardiography. J Ultrasound Med 40(12):2619\u20132627. https:\/\/doi.org\/10.1002\/jum.15651","journal-title":"J Ultrasound Med"},{"issue":"267","key":"1738_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fbioe.2019.00267","volume":"7","author":"K L\u00f3pez-Linares","year":"2019","unstructured":"L\u00f3pez-Linares K, Garc\u00eda I, Garc\u00eda A, Cortes C, Piella G, Mac\u00eda I, Noailly J, Gonz\u00e1lez Ballester MA (2019) Image-based 3d characterization of abdominal aortic aneurysm deformation after endovascular aneurysm repair. Front Bioeng Biotechnol 7(267):1\u201317. https:\/\/doi.org\/10.3389\/fbioe.2019.00267","journal-title":"Front Bioeng Biotechnol"},{"key":"1738_CR29","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/978-3-662-46836-4_4","volume-title":"Advances in metallic biomaterials: tissues, materials and biological reactions","author":"T Matsumoto","year":"2015","unstructured":"Matsumoto T, Sugita S, Yaguchi T (2015) Chap. 4 biomechanics of blood vessels: structure, mechanics, and adaptation. In: Niinomi M, Narushima T, Nakai M (eds) Advances in metallic biomaterials: tissues, materials and biological reactions. Springer, pp 71\u201398. https:\/\/doi.org\/10.1007\/978-3-662-46836-4_4"},{"key":"1738_CR30","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.cma.2018.03.033","volume":"337","author":"Y Mei","year":"2018","unstructured":"Mei Y, Hurtado DE, Pant S, Aggarwal A (2018) On improving the numerical convergence of highly nonlinear elasticity problems. Comput Methods Appl Mech Eng 337:110\u2013127. https:\/\/doi.org\/10.1016\/j.cma.2018.03.033","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"8","key":"1738_CR31","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1016\/j.acra.2013.03.014","volume":"20","author":"B Mensel","year":"2013","unstructured":"Mensel B, K\u00fchn JP, Schneider T, Quadrat A, Hegenscheid K, (2013) Mean thoracic aortic wall thickness determination by cine MRI with steady-state free precession: validation with dark blood imaging. Acad Radiol 20(8):1004\u20131008. https:\/\/doi.org\/10.1016\/j.acra.2013.03.014","journal-title":"Acad Radiol"},{"issue":"4","key":"1738_CR32","doi-asserted-by":"publisher","first-page":"1882","DOI":"10.1002\/mrm.26834","volume":"79","author":"C Montalba","year":"2018","unstructured":"Montalba C, Urbina J, Sotelo J, Andia ME, Tejos C, Irarrazaval P, Hurtado DE, Valverde I, Uribe S (2018) Variability of 4d flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantom. Magn Reson Med 79(4):1882\u20131892. https:\/\/doi.org\/10.1002\/mrm.26834","journal-title":"Magn Reson Med"},{"issue":"4","key":"1738_CR33","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1016\/j.jvs.2008.11.056","volume":"49","author":"TM Morrison","year":"2009","unstructured":"Morrison TM, Choi G, Zarins CK, Taylor CA (2009) Circumferential and longitudinal cyclic strain of the human thoracic aorta: age-related changes. J Vasc Surg 49(4):1029\u20131036. https:\/\/doi.org\/10.1016\/j.jvs.2008.11.056","journal-title":"J Vasc Surg"},{"key":"1738_CR34","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.matcom.2015.05.008","volume":"117","author":"VP Nguyen","year":"2015","unstructured":"Nguyen VP, Anitescu C, Bordas SP, Rabczuk T (2015) Isogeometric analysis: an overview and computer implementation aspects. Math Comput Simul 117:89\u2013116. https:\/\/doi.org\/10.1016\/j.matcom.2015.05.008","journal-title":"Math Comput Simul"},{"key":"1738_CR35","doi-asserted-by":"publisher","first-page":"114841","DOI":"10.1016\/j.cma.2022.114841","volume":"394","author":"D Ortiz-Puerta","year":"2022","unstructured":"Ortiz-Puerta D, Cox A, Hurtado DE (2022) Snakes isogeometric analysis (siga): towards accurate and flexible geometrical models of the respiratory airways. Comput Methods Appl Mech Eng 394:114841. https:\/\/doi.org\/10.1016\/j.cma.2022.114841","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"12","key":"1738_CR36","doi-asserted-by":"publisher","first-page":"2911","DOI":"10.1007\/s10439-017-1915-4","volume":"45","author":"S Pasta","year":"2017","unstructured":"Pasta S, Agnese V, Di Giuseppe M, Gentile G, Raffa GM, Bellavia D, Pilato M (2017) In vivo strain analysis of dilated ascending thoracic aorta by ecg-gated ct angiographic imaging. Ann Biomed Eng 45(12):2911\u20132920. https:\/\/doi.org\/10.1007\/s10439-017-1915-4","journal-title":"Ann Biomed Eng"},{"key":"1738_CR37","doi-asserted-by":"publisher","DOI":"10.4208\/cicp.OA-2020-0025","author":"AP Zhang","year":"2020","unstructured":"Pawar A, Zhang YJ  (2020) Neuronseg_bach: automated neuron segmentation using b-spline based active contour and hyperelastic regularization. Commun Comput Phys 28:1219--1244. https:\/\/doi.org\/10.4208\/cicp.OA-2020-0025","journal-title":"Commun Comput Phys"},{"issue":"4","key":"1738_CR38","doi-asserted-by":"publisher","first-page":"530","DOI":"10.1016\/j.ultrasmedbio.2006.09.009","volume":"33","author":"H Ribbers","year":"2007","unstructured":"Ribbers H, Lopata RGP, Holewijn S, Pasterkamp G, Blankensteijn JD, De Korte CL (2007) Noninvasive two-dimensional strain imaging of arteries: validation in phantoms and preliminary experience in carotid arteries in vivo. Ultrasound Med Biol 33(4):530\u2013540. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2006.09.009","journal-title":"Ultrasound Med Biol"},{"issue":"4","key":"1738_CR39","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1016\/j.ejvs.2019.05.003","volume":"58","author":"LQ Rong","year":"2019","unstructured":"Rong LQ, Palumbo MC, Rahouma M, Meineri M, Arguelles GR, Kim J, Lau C, Devereux RB, Pryor KO, Girardi LN, Redaelli A, Gaudino MFL, Weinsaft JW (2019) Immediate imact of posthetic graft replacement of the ascending aorta on cirumferential strain in the descending aorta. Eur J Vasc Endovasc Surg 58(4):521\u2013528. https:\/\/doi.org\/10.1016\/j.ejvs.2019.05.003","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"4","key":"1738_CR40","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1016\/j.jvs.2010.10.073","volume":"53","author":"EB Rosero","year":"2011","unstructured":"Rosero EB, Peshock RM, Khera A, Clagett P, Lo H, Timaran CH (2011) Sex, race, and age distributions of mean aortic wall thickness in a multiethnic population-based sample. J Vasc Surg 53(4):950\u2013957. https:\/\/doi.org\/10.1016\/j.jvs.2010.10.073","journal-title":"J Vasc Surg"},{"issue":"2","key":"1738_CR41","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1016\/j.jbiomech.2014.11.016","volume":"48","author":"A Satriano","year":"2015","unstructured":"Satriano A, Rivolo S, Martufi G, Finol EA, Di Martino ES (2015) In vivo strain assessment of the abdominal aortic aneurysm. J Biomech 48(2):354\u2013360. https:\/\/doi.org\/10.1016\/j.jbiomech.2014.11.016","journal-title":"J Biomech"},{"issue":"6","key":"1738_CR42","doi-asserted-by":"publisher","first-page":"1475","DOI":"10.1109\/TMI.2016.2517406","volume":"35","author":"J Sotelo","year":"2016","unstructured":"Sotelo J, Urbina J, Valverde I, Tejos C, Irarrazaval P, Andia ME, Uribe S, Hurtado DE (2016) 3d quantification of wall shear stress and oscillatory shear index using a finite-element method in 3d cine pc-mri data of the thoracic aorta. IEEE Trans Med Imaging 35(6):1475\u20131487. https:\/\/doi.org\/10.1109\/TMI.2016.2517406","journal-title":"IEEE Trans Med Imaging"},{"issue":"29","key":"1738_CR43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12880-015-0068-x","volume":"15","author":"A Taha","year":"2015","unstructured":"Taha A, Hanbury A (2015) Metrics for evaluating 3d medical image segmentation: analysis, selection, and tool. BMC Med Imaging 15(29):1\u201328. https:\/\/doi.org\/10.1186\/s12880-015-0068-x","journal-title":"BMC Med Imaging"},{"key":"1738_CR44","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.cma.2015.05.006","volume":"293","author":"AB Tepole","year":"2015","unstructured":"Tepole AB, Kabaria H, Bletzinger KU, Kuhl E (2015) Isogeometric kirchhoff-love shell formulations for biological membranes. Comput Methods Appl Mech Eng 293:328\u2013347. https:\/\/doi.org\/10.1016\/j.cma.2015.05.006","journal-title":"Comput Methods Appl Mech Eng"},{"issue":"2","key":"1738_CR45","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1148\/radiol.2482071568","volume":"248","author":"S Uribe","year":"2008","unstructured":"Uribe S, Tangchaoren T, Parish V, Wolf I, Razavi R, Greil G, Schaeffter T (2008) Volumetric cardiac quantification by using 3d dual-phase whole-heart mr imaging. Radiology 248(2):606\u2013614. https:\/\/doi.org\/10.1148\/radiol.2482071568","journal-title":"Radiology"},{"key":"1738_CR46","volume-title":"Variational methods in image processing","author":"LA Vese","year":"2016","unstructured":"Vese LA, Le Guyader C (2016) Variational methods in image processing. CRC Press, Boca Raton"},{"issue":"6","key":"1738_CR47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1115\/1.4040910","volume":"141","author":"JS Wilson","year":"2018","unstructured":"Wilson JS, Zhong X, Hair JB, Taylor WR, Oshinski J (2018) In vivo quantification of regional circumferential green strain in the thoracic and abdominal aorta by 2d spiral cine dense MRI. J Cardiovasc Magn Reson 141(6):1\u201314. https:\/\/doi.org\/10.1115\/1.4040910","journal-title":"J Cardiovasc Magn Reson"},{"key":"1738_CR48","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12968-019-0565-0","volume":"21","author":"JS Wilson","year":"2019","unstructured":"Wilson JS, Taylor WR, Oshinski J (2019) Assessment of the regional distribution of normalized circumferential strain in the thoracic and abdominal aorta using dense cardiovascular magnetic resonance. J Cardiovasc Magn Reson 21:1\u201314. https:\/\/doi.org\/10.1186\/s12968-019-0565-0","journal-title":"J Cardiovasc Magn Reson"},{"key":"1738_CR49","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.jmbbm.2015.09.022","volume":"58","author":"A Wittek","year":"2016","unstructured":"Wittek A, Derwich W, Karatolios K, Fritzen CP, Vogt S, Schmitz-Rixen T, Blase C (2016) A finite element updating approach for identification of the anisotropic hyperelastic properties of normal and diseased aortic walls from 4d ultrasound strain imaging. J Mech Behav Biomed Mater 58:122\u2013138. https:\/\/doi.org\/10.1016\/j.jmbbm.2015.09.022","journal-title":"J Mech Behav Biomed Mater"},{"key":"1738_CR50","doi-asserted-by":"publisher","unstructured":"Wittek A, Blase C, Derwich W, Vogt S, Schmitz-Rixen T, Fritzen CP (2017) Characterization of the mechanical behavior and pathophysiological state of abdominal aortic aneurysms based on 4d ultrasound strain imaging. Proceedings SPIE 10333, Optical Methods for Inspection, Characterization, and Imaging of Biomaterials III 1033303. https:\/\/doi.org\/10.1117\/12.2271979","DOI":"10.1117\/12.2271979"},{"issue":"3","key":"1738_CR51","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","volume":"31","author":"PA Yushkevich","year":"2006","unstructured":"Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3d active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116\u20131128. https:\/\/doi.org\/10.1016\/j.neuroimage.2006.01.015","journal-title":"Neuroimage"}],"container-title":["Engineering with Computers"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00366-022-01738-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00366-022-01738-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00366-022-01738-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,12]],"date-time":"2022-11-12T12:16:58Z","timestamp":1668255418000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00366-022-01738-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":51,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["1738"],"URL":"https:\/\/doi.org\/10.1007\/s00366-022-01738-y","relation":{},"ISSN":["0177-0667","1435-5663"],"issn-type":[{"type":"print","value":"0177-0667"},{"type":"electronic","value":"1435-5663"}],"subject":[],"published":{"date-parts":[[2022,10]]},"assertion":[{"value":"27 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors state that there is no potential conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}