{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T03:17:21Z","timestamp":1740107841691,"version":"3.37.3"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"24","license":[{"start":{"date-parts":[[2020,6,24]],"date-time":"2020-06-24T00:00:00Z","timestamp":1592956800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,24]],"date-time":"2020-06-24T00:00:00Z","timestamp":1592956800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Ontario Consortium for Adaptive Interventions in Radiation Oncology"},{"DOI":"10.13039\/100009142","name":"Cancer Care Ontario","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100009142","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Soft Comput"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1007\/s00500-020-05126-w","type":"journal-article","created":{"date-parts":[[2020,6,24]],"date-time":"2020-06-24T17:03:40Z","timestamp":1593018220000},"page":"18959-18970","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Using fuzzy logics to determine optimal oversampling factor for voxelizing 3D surfaces in radiation therapy"],"prefix":"10.1007","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9982-3194","authenticated-orcid":false,"given":"C.","family":"Pinter","sequence":"first","affiliation":[]},{"given":"T.","family":"Olding","sequence":"additional","affiliation":[]},{"given":"L. J.","family":"Schreiner","sequence":"additional","affiliation":[]},{"given":"G.","family":"Fichtinger","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,6,24]]},"reference":[{"issue":"6","key":"5126_CR1","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1118\/1.597333","volume":"21","author":"AM Alyassin","year":"1994","unstructured":"Alyassin AM, Lancaster JL, Downs JH, Fox PT (1994) Evaluation of new algorithms for the interactive measurement of surface area and volume. Med Phys 21(6):741\u2013752","journal-title":"Med Phys"},{"issue":"10","key":"5126_CR2","doi-asserted-by":"publisher","first-page":"105004","DOI":"10.1088\/1361-6560\/aabd14","volume":"63","author":"A Babier","year":"2018","unstructured":"Babier A, Boutilier JJ, Sharpe MB, McNiven AL, Chan TC (2018) Inverse optimization of objective function weights for treatment planning using clinical dose-volume histograms. Phys Med Biol 63(10):105004","journal-title":"Phys Med Biol"},{"key":"5126_CR3","unstructured":"Brinkhoff T, Kriegel HP, Schneider R, Braun A (1995) Measuring the complexity of polygonal objects. In: ACM-GIS, p. 109"},{"issue":"6","key":"5126_CR4","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1118\/1.1477417","volume":"29","author":"JF Corbett","year":"2002","unstructured":"Corbett JF, Jezioranski J, Crook J, Yeung I (2002) The effect of voxel size on the accuracy of dose-volume histograms of prostate 125I seed implants. Med Phys 29(6):1003\u20131006","journal-title":"Med Phys"},{"issue":"5","key":"5126_CR5","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1093\/jnci\/djn020","volume":"100","author":"IJ Das","year":"2008","unstructured":"Das IJ, Cheng CW, Chopra KL, Mitra RK, Srivastava SP, Glatstein E (2008) Intensity-modulated radiation therapy dose prescription, recording, and delivery: patterns of variability among institutions and treatment planning systems. J Natl Cancer Inst 100(5):300\u2013307","journal-title":"J Natl Cancer Inst"},{"issue":"5","key":"5126_CR6","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1118\/1.1568978","volume":"30","author":"JO Deasy","year":"2003","unstructured":"Deasy JO, Blanco AI, Clark VH (2003) CERR: a computational environment for radiotherapy research. Med Phys 30(5):979\u2013985","journal-title":"Med Phys"},{"issue":"3","key":"5126_CR7","doi-asserted-by":"publisher","first-page":"297","DOI":"10.2307\/1932409","volume":"26","author":"LR Dice","year":"1945","unstructured":"Dice LR (1945) Measures of the amount of ecologic association between species. Ecology 26(3):297\u2013302","journal-title":"Ecology"},{"issue":"1","key":"5126_CR8","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/0360-3016(91)90168-4","volume":"21","author":"RE Drzymala","year":"1991","unstructured":"Drzymala RE, Mohan R, Brewster L, Chu J, Goitein M, Harms W, Urie M (1991) Dose-volume histograms. Int J Radiat Oncol Biol Phys 21(1):71\u201378","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"11","key":"5126_CR9","doi-asserted-by":"publisher","first-page":"N337","DOI":"10.1088\/0031-9155\/55\/11\/N04","volume":"55","author":"MA Ebert","year":"2010","unstructured":"Ebert MA, Haworth A, Kearvell R, Hooton B, Hug B, Spry NA, Joseph DJ (2010) Comparison of DVH data from multiple radiotherapy treatment planning systems. Phys Med Biol 55(11):N337","journal-title":"Phys Med Biol"},{"key":"5126_CR10","unstructured":"Eisemann E, D\u00e9coret X (2008) Single-pass GPU solid voxelization for real-time applications. In: Proceedings of graphics interface, pp 73\u201380"},{"issue":"9","key":"5126_CR11","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J (2012) 3D Slicer as an image computing platform for the quantitative imaging network. Magnc Reson Imaging 30(9):1323\u20131341","journal-title":"Magnc Reson Imaging"},{"issue":"10","key":"5126_CR12","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1118\/1.598373","volume":"25","author":"B Fraass","year":"1998","unstructured":"Fraass B, Doppke K, Hunt M, Kutcher G, Starkschall G, Stern R, Van Dyke J (1998) American association of physicists in medicine radiation therapy committee task group 53: quality assurance for clinical radiotherapy treatment planning. Medl Phys 25(10):1773\u20131829","journal-title":"Medl Phys"},{"issue":"4","key":"5126_CR13","first-page":"197","volume":"35","author":"MS Gossman","year":"2010","unstructured":"Gossman MS, Bank MI (2010) Dose-volume histogram quality assurance for linac-based treatment planning systems. J Med Phys Assoc Med Phys India 35(4):197","journal-title":"J Med Phys Assoc Med Phys India"},{"issue":"1","key":"5126_CR14","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1120\/jacmp.v17i1.5901","volume":"17","author":"I Hazell","year":"2016","unstructured":"Hazell I, Bzdusek K, Kumar P, Hansen CR, Bertelsen A, Eriksen JG, Brink C (2016) Automatic planning of head and neck treatment plans. J Appl Clin Med Phys 17(1):272\u2013282","journal-title":"J Appl Clin Med Phys"},{"key":"5126_CR15","unstructured":"Huang J, Yagel R, Filippov V, Kurzion Y (2014) An accurate method for voxelizing polygon meshes. In: IEEE symposium on volume visualization (Cat. No.989EX300), pp 119\u2013126"},{"issue":"9","key":"5126_CR16","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1109\/34.232073","volume":"15","author":"DP Huttenlocher","year":"1993","unstructured":"Huttenlocher DP, Klanderman GA, Rucklidge WJ (1993) Comparing images using the Hausdorff distance. IEEE Trans Pattern Anal Mach Intell 15(9):850\u2013863","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"3","key":"5126_CR17","doi-asserted-by":"publisher","first-page":"901","DOI":"10.1016\/j.ijrobp.2005.02.040","volume":"62","author":"C Kirisits","year":"2005","unstructured":"Kirisits C, P\u00f6tter R, Lang S, Dimopoulos J, Wachter-Gerstner N, Georg D (2005) Dose and volume parameters for MRI-based treatment planning in intracavitary brachytherapy for cervical cancer. Int J Radiat Oncol Biol Phys 62(3):901\u2013911","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"5126_CR18","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1118\/1.597029","volume":"20","author":"HM Kooy","year":"1993","unstructured":"Kooy HM, Nedzi LA, Alexander E, Loeffler JS, Ledoux RJ (1993) Dose-volume histogram computations for small intracranial volumes. Med Phys 20(3):755\u2013760","journal-title":"Med Phys"},{"issue":"6","key":"5126_CR19","first-page":"2961","volume":"44","author":"J Leasure","year":"2017","unstructured":"Leasure J, Ulizio V, Pearson D (2017) Isodose volume comparison of two common volume derivation methods. Med Phys 44(6):2961","journal-title":"Med Phys"},{"issue":"2","key":"5126_CR20","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1109\/21.52551","volume":"20","author":"CC Lee","year":"1990","unstructured":"Lee CC (1990) Fuzzy logic in control systems: fuzzy logic controller. I. IEEE Trans Syst Man Cybern 20(2):404\u2013418","journal-title":"IEEE Trans Syst Man Cybern"},{"issue":"3","key":"5126_CR21","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1093\/jrr\/rrv001","volume":"56","author":"H Makishima","year":"2015","unstructured":"Makishima H, Ishikawa H, Terunuma T, Hashimoto T, Yamanashi K, Sekiguchi T, Sakurai H (2015) Comparison of adverse effects of proton and X-ray chemoradiotherapy for esophageal cancer using an adaptive dose\u2013volume histogram analysis. J Radiat Res 56(3):568\u2013576","journal-title":"J Radiat Res"},{"key":"5126_CR22","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1007\/s003300101100","volume":"12","author":"P Mildenberger","year":"2002","unstructured":"Mildenberger P, Eichelberg M, Martin E (2002) Introduction to the DICOM standard. Eur Radiol 12:920\u2013927","journal-title":"Eur Radiol"},{"issue":"2","key":"5126_CR23","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1016\/j.ijrobp.2018.09.041","volume":"103","author":"KA Mountris","year":"2019","unstructured":"Mountris KA, Visvikis D, Bert J (2019) DVH-based inverse planning using Monte Carlo dosimetry for LDR prostate brachytherapy. Int J Radiat Oncol Biol Phys 103(2):503\u2013510","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"8","key":"5126_CR24","doi-asserted-by":"publisher","first-page":"4435","DOI":"10.1118\/1.4923175","volume":"42","author":"B Nelms","year":"2015","unstructured":"Nelms B, Stambaugh C, Hunt D, Tonner B, Zhang G, Feygelman V (2015) Methods, software and datasets to verify DVH calculations against analytical values: twenty years late (r). Med Phys 42(8):4435\u20134448","journal-title":"Med Phys"},{"issue":"3","key":"5126_CR25","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1109\/TVCG.2009.74","volume":"16","author":"P Novotn\u00fd","year":"2010","unstructured":"Novotn\u00fd P, Dimitrov LI, \u0160r\u00e1mek M (2010) Enhanced voxelization and representation of objects with sharp details in truncated distance fields. IEEE Trans Vis Comput Gr 16(3):484\u2013498","journal-title":"IEEE Trans Vis Comput Gr"},{"issue":"3","key":"5126_CR26","first-page":"183","volume":"14","author":"J O\u2019Rourke","year":"1985","unstructured":"O\u2019Rourke J (1985) Finding minimal enclosing boxes. Int J Parallel Program 14(3):183\u2013199","journal-title":"Int J Parallel Program"},{"issue":"10","key":"5126_CR27","doi-asserted-by":"publisher","first-page":"6332","DOI":"10.1118\/1.4754659","volume":"39","author":"C Pinter","year":"2012","unstructured":"Pinter C, Lasso A, Wang A, Jaffray D, Fichtinger G (2012) SlicerRT: radiation therapy research toolkit for 3D Slicer. Med Phys 39(10):6332\u20136338","journal-title":"Med Phys"},{"key":"5126_CR28","doi-asserted-by":"crossref","unstructured":"Rigau J, Feixas M, Sbert M (2005) Shape complexity based on mutual information. In: 2005 International conference shape modeling and applications, IEEE, pp 355\u2013360","DOI":"10.1109\/SMI.2005.42"},{"issue":"2","key":"5126_CR29","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1016\/j.radonc.2004.02.015","volume":"71","author":"G Rodrigues","year":"2004","unstructured":"Rodrigues G, Lock M, D\u2019Souza D, Yu E, Van Dyk J (2004) Prediction of radiation pneumonitis by dose\u2013volume histogram parameters in lung cancer\u2014a systematic review. Radiother Oncol 71(2):127\u2013138","journal-title":"Radiother Oncol"},{"issue":"3","key":"5126_CR30","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1016\/j.radonc.2008.09.010","volume":"91","author":"J Rose","year":"2009","unstructured":"Rose J, Rodrigues G, Yaremko B, Lock M, D\u2019Souza D (2009) Systematic review of dose\u2013volume parameters in the prediction of esophagitis in thoracic radiotherapy. Radiother Oncol 91(3):282\u2013287","journal-title":"Radiother Oncol"},{"key":"5126_CR31","volume-title":"The visualization toolkit: an object-oriented approach to 3D graphics","author":"WJ Schroeder","year":"2004","unstructured":"Schroeder WJ, Lorensen B, Martin K (2004) The visualization toolkit: an object-oriented approach to 3D graphics. Kitware, New York"},{"issue":"6","key":"5126_CR32","first-page":"179","volume":"29","author":"M Schwarz","year":"2010","unstructured":"Schwarz M, Seidel H-P (2010) Fast parallel surface and solid voxelization on GPUs. ACM Trans Gr (TOG) 29(6):179","journal-title":"ACM Trans Gr (TOG)"},{"key":"5126_CR33","doi-asserted-by":"crossref","unstructured":"Sunderland K, Woo B, Pinter C, Fichtinger G (2015) Reconstruction of surfaces from planar contours through contour interpolation. In: Medical imaging 2015: image-guided procedures, robotic interventions, and modeling, vol 9415, [94151R] SPIE","DOI":"10.1117\/12.2081436"},{"key":"5126_CR34","doi-asserted-by":"crossref","unstructured":"Sunderland K, Pinter C, Lasso A, Fichtinger G (2016) Effects of voxelization on dose volume histogram accuracy. In: Medical imaging 2016: image-guided procedures, robotic interventions, and modeling, vol 9786, [97862O] SPIE","DOI":"10.1117\/12.2216310"}],"container-title":["Soft Computing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00500-020-05126-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00500-020-05126-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00500-020-05126-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,24]],"date-time":"2021-06-24T01:11:25Z","timestamp":1624497085000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00500-020-05126-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,24]]},"references-count":34,"journal-issue":{"issue":"24","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["5126"],"URL":"https:\/\/doi.org\/10.1007\/s00500-020-05126-w","relation":{},"ISSN":["1432-7643","1433-7479"],"issn-type":[{"type":"print","value":"1432-7643"},{"type":"electronic","value":"1433-7479"}],"subject":[],"published":{"date-parts":[[2020,6,24]]},"assertion":[{"value":"24 June 2020","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human animal rights"}}]}}