{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,23]],"date-time":"2024-09-23T03:54:26Z","timestamp":1727063666399},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2014,11,27]],"date-time":"2014-11-27T00:00:00Z","timestamp":1417046400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Elektrotech. Inftech."],"published-print":{"date-parts":[[2014,12]]},"DOI":"10.1007\/s00502-014-0236-7","type":"journal-article","created":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T10:19:55Z","timestamp":1417429195000},"page":"386-392","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Application of the UHF technology to detect and locate partial discharges in liquid immersed transformer"],"prefix":"10.1007","volume":"131","author":[{"given":"Stefan M.","family":"Hoek","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Kr\u00fcger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephan","family":"K\u00f6rber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Kraetge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2014,11,27]]},"reference":[{"key":"236_CR1","volume-title":"Partial discharges in electrical power apparatus","author":"D. K\u00f6nig","year":"1993","unstructured":"K\u00f6nig, D., Rao, Y. N. (1993): Partial discharges in electrical power apparatus. Berlin: VDE."},{"key":"236_CR2","volume-title":"IEC 60270: High-voltage test techniques\u2014partial discharge measurement","author":"IEC","year":"2000","unstructured":"IEC (2000): IEC 60270: High-voltage test techniques\u2014partial discharge measurement. 3rd ed. Geneva: International Electrotechnical Commission.","edition":"3"},{"issue":"6","key":"236_CR3","doi-asserted-by":"crossref","first-page":"2043","DOI":"10.1109\/TDEI.2013.6678852","volume":"20","author":"M. Koch","year":"2013","unstructured":"Koch, M., Kraetge, A., Koltunowicz, W., Hoek, S. M. (2013): Robust measurement, monitoring and analysis of partial discharges in transformers and other HV apparatus. IEEE Trans. Dielectr. Electr. Insul., 20(6), 2043\u20132051. doi: 10.1109\/TDEI.2013.6678852 .","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"236_CR4","volume-title":"Conference on condition monitoring and diagnosis, CMD, Tokyo, Japan, September 2010","author":"S. M. Hoek","year":"2010","unstructured":"Hoek, S. M., Koch, M., Heindl, M. (2010): Propagation mechanisms of PD pulses for UHF and traditional electrical measurements. In Conference on condition monitoring and diagnosis, CMD, Tokyo, Japan, September 2010. Paper No. C2-02."},{"issue":"6","key":"236_CR5","doi-asserted-by":"crossref","first-page":"1544","DOI":"10.1109\/TDEI.2008.4712656","volume":"15","author":"S. Tenbohlen","year":"2008","unstructured":"Tenbohlen, S., Hoek, S. M., Denissov, D., Markalous, S. M. (2008): Partial discharge measurement in the ultra high frequency (UHF) range. IEEE Trans. Dielectr. Electr. Insul., 15(6), 1544\u20131552. doi: 10.1109\/TDEI.2008.4712656 .","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"236_CR6","volume-title":"Conference on electrical insulation and dielectric phenomena, Cancun, Mexico, 2011","author":"A. Cavallini","year":"2011","unstructured":"Cavallini, A., Ramos, C. G. A., Montanari, G. C., Saad, H., Tozzi, M. (2011): UHF detection of PD in power transformers: the influence of disturbances. In Conference on electrical insulation and dielectric phenomena, Cancun, Mexico, 2011. doi: 10.1109\/CEIDP.2011.6232688 ."},{"key":"236_CR7","volume-title":"IEEE conference on condition monitoring and diagnosis, CMD, Beijing, China, April 2008","author":"M. D. Judd","year":"2008","unstructured":"Judd, M. D., Meijer, S., Tenbohlen, S. (2008): Sensitivity check for radio frequency partial discharge detection for power transformers. In IEEE conference on condition monitoring and diagnosis, CMD, Beijing, China, April 2008. Paper No. K1-03. doi: 10.1109\/CMD.2008.4580458 ."},{"key":"236_CR8","volume-title":"int. conf. on condition monitoring and diagnosis, Beijing, China, April 2008","author":"S. M. Hoek","year":"2008","unstructured":"Hoek, S. M., Coenen, S., Bornowski, M., Tenbohlen, S. (2008): Fundamental differences of the PD measurement according to IEC 60270 and in UHF range. In int. conf. on condition monitoring and diagnosis, Beijing, China, April 2008. doi: 10.1109\/CMD.2008.4580234 ."},{"key":"236_CR9","first-page":"1553","volume-title":"IEEE transactions on dielectrics and electrical insulation","author":"S. Coenen","year":"2008","unstructured":"Coenen, S., Tenbohlen, S., Markalous, S. M., Strehl, T. (2008): Sensitivity of UHF PD measurements in power transformers. In IEEE transactions on dielectrics and electrical insulation (Vol.\u00a015, pp. 1553\u20131558). doi: 10.1109\/TDEI.2008.4712657 ."},{"key":"236_CR10","volume-title":"High-volt Kolloquium\u201911, Dresden, Germany, May 2011","author":"S. M. Neuhold","year":"2011","unstructured":"Neuhold, S. M. (2011): On site tests of GIS. In High-volt Kolloquium\u201911, Dresden, Germany, May 2011."},{"key":"236_CR11","volume-title":"CIGRE 2012, Paris, France, August 2012","author":"S. M. Hoek","year":"2012","unstructured":"Hoek, S. M., Neuhold, S. M. (2012): Tuned medium-band UHF PD measurement method for GIS. In CIGRE 2012, Paris, France, August 2012. Paper No. D1-304."},{"key":"236_CR12","first-page":"75","volume":"183","author":"CIGRE","year":"1999","unstructured":"CIGRE (1999): CIGRE task force 15\/33.03.05: Partial discharge detection system for GIS: sensitivity verification for the UHF method and the acoustic method. Electra, 183, 75\u201387.","journal-title":"Electra"},{"key":"236_CR13","volume-title":"IEEE symposium on electrical insulation, ISEI 2000, Anaheim, CA, USA","author":"M. D. Judd","year":"2000","unstructured":"Judd, M. D., Farish, O., Pearson, J. S., Breckenridge, T., Pryor, B. M. (2000): Power transformer monitoring using UHF sensors installation and testing. In IEEE symposium on electrical insulation, ISEI 2000, Anaheim, CA, USA, pp. 373\u2013376. doi: 10.1109\/ELINSL.2000.845528 ."},{"issue":"6","key":"236_CR14","doi-asserted-by":"crossref","first-page":"1934","DOI":"10.1109\/TDEI.2012.6396950","volume":"19","author":"S. Coenen","year":"2012","unstructured":"Coenen, S., Tenbohlen, S. (2012): Location of PD sources in power transformers by UHF and acoustic measurements. IEEE Trans. Dielectr. Electr. Insul., 19(6), 1934\u20131940. doi: 10.1109\/TDEI.2012.6396950 .","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"236_CR15","volume-title":"2011 electrical insulation conference, Annapolis, Maryland, June 2011","author":"M. D. Judd","year":"2011","unstructured":"Judd, M. D. (2011): Experience with UHF partial discharge detection and location in power transformers. In 2011 electrical insulation conference, Annapolis, Maryland, June 2011. doi: 10.1109\/EIC.2011.5996146 ."},{"key":"236_CR16","volume-title":"CIGRE SC A2&D1 colloquium, Kyoto, Japan, September 2011","author":"A. Kraetge","year":"2011","unstructured":"Kraetge, A., Hoek, S. M., Rethmeier, K., Kr\u00fcger, M. (2011): Modern de-noising strategies for PD measurements on transformers under challenging on-site conditions. In CIGRE SC A2&D1 colloquium, Kyoto, Japan, September 2011. Paper No. PS1-O-14."},{"key":"236_CR17","volume-title":"18th ISH, Seoul, South Korea, August 2013","author":"S. M. Hoek","year":"2013","unstructured":"Hoek, S. M., Kraetge, A., K\u00f6rber, S., Badicu, L.-V., Kessler, O., Broniecki, U., Hong, I. (2013): Combining acoustical and different electrical methods for localizing partial discharges in a power transformer. In 18th ISH, Seoul, South Korea, August 2013. Paper No. OD5-05."}],"container-title":["e &amp; i Elektrotechnik und Informationstechnik"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-014-0236-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00502-014-0236-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-014-0236-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T08:21:57Z","timestamp":1559118117000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00502-014-0236-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11,27]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["236"],"URL":"https:\/\/doi.org\/10.1007\/s00502-014-0236-7","relation":{},"ISSN":["0932-383X","1613-7620"],"issn-type":[{"value":"0932-383X","type":"print"},{"value":"1613-7620","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,11,27]]}}}