{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T05:03:00Z","timestamp":1703653380084},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T00:00:00Z","timestamp":1543449600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T00:00:00Z","timestamp":1543449600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Elektrotech. Inftech."],"published-print":{"date-parts":[[2018,12]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>Die Gleichstrom\u00fcbertragung kann bei der L\u00f6sung der bestehenden Herausforderungen im Mittelspannungsnetz einen Beitrag leisten und zu einem sicheren Netzbetrieb beitragen. MG\u00dc-Anwendungen k\u00f6nnen dabei unter anderem f\u00fcr die Erh\u00f6hung der \u00dcbertragungskapazit\u00e4t von einzelnen Leitungen (Freileitung, Kabel) und eine flexible Lastflusssteuerung sorgen. Es besteht die M\u00f6glichkeit, bereits in Betrieb befindliche extrudierte AC-Kabelsysteme auf DC-Betrieb umzur\u00fcsten. Dabei sind zahlreiche technische Aspekte zu betrachten, die auch f\u00fcr einen Einsatz von neuen extrudierten AC-Standard-Kabeln f\u00fcr die MG\u00dc gelten. Die in Anlehnung an die CIGRE TB 496 bisher durchgef\u00fchrten experimentellen Untersuchungen zeigen, dass ein handels\u00fcbliches 12\/20-kV-VPE-AC-Kabelsystem den DC-Beanspruchungen des LCC-Pr\u00e4qualifikationstests f\u00fcr ein extrudiertes 55-kV-DC-Kabel standhalten kann.<\/jats:p>","DOI":"10.1007\/s00502-018-0658-8","type":"journal-article","created":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T07:19:30Z","timestamp":1543475970000},"page":"520-526","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Realisierung einer Mittelspannungs-Gleichstrom\u00fcbertragung mit extrudierten AC-Kabeln","Implementation of Medium-Voltage Direct Current transmission with extruded AC cables"],"prefix":"10.1007","volume":"135","author":[{"given":"Uwe","family":"Schichler","sequence":"first","affiliation":[]},{"given":"Anton","family":"Buchner","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,11,29]]},"reference":[{"issue":"2","key":"658_CR1","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1109\/JPROC.2011.2152310","volume":"100","author":"Hammons","year":"2012","unstructured":"Hammons et al. (2012): State of the art in ultrahigh-voltage transmission. Proc. IEEE, 100(2), 360\u2013390.","journal-title":"Proc. IEEE"},{"key":"658_CR2","volume-title":"IET int. conf. on AC and DC power transmission","author":"Bathurst","year":"2015","unstructured":"Bathurst, Hwang, Tejwani (2015): MVDC \u2013 the new technology for distribution networks. In IET int. conf. on AC and DC power transmission, Birmingham."},{"key":"658_CR3","volume-title":"CIRED","author":"Yu","year":"2017","unstructured":"Yu et al. (2017): Initial designs for ANGLE-DC project: challenges converting existing AC cable and overhead line to DC operation. In CIRED, Glasgow. Report 0974."},{"key":"658_CR4","volume-title":"CIRED","author":"Burstein","year":"2017","unstructured":"Burstein, Cuk, de Jong (2017): Determining potential capacity gains when repurposing MV AC cables for DC power transportation. In CIRED, Glasgow. Report 0142."},{"key":"658_CR5","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.ijepes.2017.06.012","volume":"93","author":"Shekhar","year":"2017","unstructured":"Shekhar et al. (2017): Grid capacity and efficiency enhancement by operating medium voltage AC cables as DC links with modular multilevel converters. Electr. Power & Energy Syst., 93, 479\u2013493.","journal-title":"Electr. Power & Energy Syst."},{"issue":"3","key":"658_CR6","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1109\/TPWRD.2015.2496178","volume":"32","author":"Liu","year":"2017","unstructured":"Liu, Cao, Fu (2017): The upgrading renovation of an existing XLPE cable circuit by conversion of AC line to DC operation. IEEE Trans. Power Deliv., 32(3), 1321\u20131328.","journal-title":"IEEE Trans. Power Deliv."},{"key":"658_CR7","volume-title":"VDE-Fachtagung ,,Hochspannungstechnik\u201c","author":"Schichler","year":"2018","unstructured":"Schichler, Buchner (2018): Anwendung von extrudierten AC-Kabeln f\u00fcr die Mittelspannungs-Gleichstrom\u00fcbertragung (MG\u00dc). In VDE-Fachtagung ,,Hochspannungstechnik\u201c, Berlin."},{"key":"658_CR8","first-page":"80","volume":"11","author":"Montanari","year":"2018","unstructured":"Montanari et al. (2018): Challenges and opportunities with interfaces and materials for HVDC cable systems. CIGRE Sci. Eng., 11, 80\u201387. June","journal-title":"CIGRE Sci. Eng."},{"key":"658_CR9","volume-title":"CIGRE","author":"Brueggmann","year":"2018","unstructured":"Brueggmann et al. (2018): Prequalification test of extruded HVDC 525-kV-underground cables. In CIGRE, Paris Session. Report B1-308."},{"key":"658_CR10","volume-title":"CIGRE","author":"Jeroense","year":"2018","unstructured":"Jeroense et al. (2018): Fully qualified 640 kV underground extruded DC cable system. In CIGRE, Paris Session. Report B1-309."},{"key":"658_CR11","doi-asserted-by":"publisher","DOI":"10.1002\/9781118590423","volume-title":"Extruded cables for high-voltage direct-current transmission","author":"Mazzanti","year":"2013","unstructured":"Mazzanti, Marzinotto (2013): Extruded cables for high-voltage direct-current transmission. New York: Wiley."},{"issue":"2","key":"658_CR12","doi-asserted-by":"publisher","first-page":"9","DOI":"10.17775\/CSEEJPES.2015.00015","volume":"1","author":"Chen","year":"2015","unstructured":"Chen et al. (2015): Review of high voltage direct current cables. CSEE J. Power Energy Syst., 1(2), 9\u201321.","journal-title":"CSEE J. Power Energy Syst."},{"key":"658_CR13","unstructured":"CIGRE WG B1.32 (2012): Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to 500 kV. CIGRE technical brochure, 496."},{"key":"658_CR14","volume-title":"20. ISH, Buenos Aires","author":"Voss","year":"2017","unstructured":"Voss, Gamlin (2017): Superimposed impulse voltage testing on extruded DC-cables according to IEC CDV 62895. In 20. ISH, Buenos Aires. Report 195."},{"key":"658_CR15","volume-title":"12. ICPADM","author":"Pischler","year":"2018","unstructured":"Pischler, Schichler (2018): Challenges resulting from the use of spark gaps for composite voltage tests. In 12. ICPADM, Xian. Report 54."},{"issue":"17","key":"658_CR16","first-page":"1030","volume":"74","author":"Modrusan","year":"1983","unstructured":"Modrusan (1983): Hochspannungsteiler: Typen, Messeigenschaften und Einsatz. Bull. ASE\/UCS, 74(17), 1030\u20131037.","journal-title":"Bull. ASE\/UCS"},{"issue":"2","key":"658_CR17","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1109\/T-PAS.1976.32140","volume":"95","author":"Harada","year":"1976","unstructured":"Harada, Aoshima, Okamura, Hiwa (1976): Development of a high voltage universal divider. IEEE Trans. Power Appar. Syst., 95(2), 595\u2013600.","journal-title":"IEEE Trans. Power Appar. Syst."}],"container-title":["e &amp; i Elektrotechnik und Informationstechnik"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00502-018-0658-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-018-0658-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-018-0658-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T01:02:49Z","timestamp":1703638969000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00502-018-0658-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,29]]},"references-count":17,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["658"],"URL":"https:\/\/doi.org\/10.1007\/s00502-018-0658-8","relation":{},"ISSN":["0932-383X","1613-7620"],"issn-type":[{"value":"0932-383X","type":"print"},{"value":"1613-7620","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,29]]},"assertion":[{"value":"22 July 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}