{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,22]],"date-time":"2025-11-22T17:05:06Z","timestamp":1763831106130},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2020,4,8]],"date-time":"2020-04-08T00:00:00Z","timestamp":1586304000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.de"},{"start":{"date-parts":[[2020,4,8]],"date-time":"2020-04-08T00:00:00Z","timestamp":1586304000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/deed.de"}],"funder":[{"name":"Austrian Research Promotion Agency","award":["824187","849109"],"award-info":[{"award-number":["824187","849109"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Elektrotech. Inftech."],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Piezoelectric silicon micro-machined resonators triggered in the two-dimensional roof-tile shaped mode exhibit exceptionally high quality factors even in highly viscous liquids. In combination with an all-electric readout, this enables precise measurements in liquid media with high output signals, if the electrode design and the anchor geometry are tailored to match the selected order of the roof-tile shaped mode. This paper provides an overview of this promising class of resonator modes for micro-electromechanical systems (MEMS) and highlights three application scenarios. In the food industry, the MEMS sensor can be used to monitor the fermentation process in wine by tracking the density and hence, the concentration of ethanol. In technical lubricants, the concentration of ferrous particles can be monitored by integrating a magnetic actuator on the resonator. Finally, even in highly viscous bitumen, the MEMS sensor is successfully used to measure the viscosity of this material.<\/jats:p>","DOI":"10.1007\/s00502-020-00794-w","type":"journal-article","created":{"date-parts":[[2020,4,8]],"date-time":"2020-04-08T11:02:39Z","timestamp":1586343759000},"page":"121-127","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["High performance piezoelectric AlN MEMS resonators for precise sensing in liquids"],"prefix":"10.1007","volume":"137","author":[{"given":"Michael","family":"Schneider","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georg","family":"Pfusterschmied","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florian","family":"Patocka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrich","family":"Schmid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,8]]},"reference":[{"key":"794_CR1","doi-asserted-by":"publisher","DOI":"10.1063\/1.4758470","volume":"101","author":"T. Manzaneque","year":"2012","unstructured":"Manzaneque, T., et al. (2012): Characterization and simulation of the first extensional mode of rectangular micro-plates in liquid media. Appl. Phys. Lett., 101, 151904. https:\/\/doi.org\/10.1063\/1.4758470.","journal-title":"Appl. Phys. Lett."},{"key":"794_CR2","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/19\/7\/075010","volume":"19","author":"C. Riesch","year":"2009","unstructured":"Riesch, C., et al. (2009): A suspended plate viscosity sensor featuring in-plane vibration and piezoresistive readout. J. Micromech. Microeng., 19, 075010. https:\/\/doi.org\/10.1088\/0960-1317\/19\/7\/075010.","journal-title":"J. Micromech. Microeng."},{"key":"794_CR3","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1109\/I2MTC.2012.6229687","volume-title":"2012 IEEE I2MTC \u2013 proceedings of the international instrumentation and measurement technology conference","author":"J. K. Sell","year":"2012","unstructured":"Sell, J. K., Niedermayer, A. O. (2012): Jakoby B reactance-locked loop for driving resonant sensors. In 2012 IEEE I2MTC \u2013 proceedings of the international instrumentation and measurement technology conference (pp. 1113\u20131116). https:\/\/doi.org\/10.1109\/I2MTC.2012.6229687."},{"issue":"1","key":"794_CR4","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1116\/1.586300","volume":"10","author":"F. R. Blom","year":"1992","unstructured":"Blom, F. R., Bouwstra, S., Elwenspoek, M., Fluitman, J. H. J. (1992): Dependence of the quality factor of micromachined silicon beam resonators on pressure and geometry. J Vac Sci Technol B, 10(1), 19\u201326.","journal-title":"J Vac Sci Technol B"},{"issue":"5","key":"794_CR5","doi-asserted-by":"publisher","first-page":"2682","DOI":"10.1063\/1.1642738","volume":"95","author":"K. L. Ekinci","year":"2004","unstructured":"Ekinci, K. L., Yang, Y. T., Roukes, M. L. (2004): Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems. J. Appl. Phys., 95(5), 2682\u20132689. https:\/\/doi.org\/10.1063\/1.1642738.","journal-title":"J. Appl. Phys."},{"issue":"2","key":"794_CR6","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1088\/0957-4484\/12\/2\/305","volume":"12","author":"G. Abadal","year":"2001","unstructured":"Abadal, G., et al. (2001): Electromechanical model of a resonating nano-cantilever-based sensor for high-resolution and high-sensitivity mass detection. Nanotechnology, 12(2), 100\u2013104. https:\/\/doi.org\/10.1088\/0957-4484\/12\/2\/305.","journal-title":"Nanotechnology"},{"issue":"1\u20133","key":"794_CR7","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1016\/S0925-4005(03)00110-2","volume":"91","author":"I. Dufour","year":"2003","unstructured":"Dufour, I., Fadel, L. (2003): Resonant microcantilever type chemical sensors: analytical modeling in view of optimization. Sens. Actuators B, Chem., 91(1\u20133), 353\u2013361. https:\/\/doi.org\/10.1016\/S0925-4005(03)00110-2.","journal-title":"Sens. Actuators B, Chem."},{"issue":"12","key":"794_CR8","doi-asserted-by":"publisher","first-page":"2491","DOI":"10.1088\/0960-1317\/17\/12\/015","volume":"17","author":"T. Ikehara","year":"2007","unstructured":"Ikehara, T., Lu, J., Konno, M., Maeda, R., Mihara, T. (2007): A high quality-factor silicon cantilever for a low detection-limit resonant mass sensor operated in air. J. Micromech. Microeng., 17(12), 2491\u20132494. https:\/\/doi.org\/10.1088\/0960-1317\/17\/12\/015.","journal-title":"J. Micromech. Microeng."},{"issue":"1","key":"794_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.bios.2011.10.054","volume":"32","author":"B. N. Johnson","year":"2012","unstructured":"Johnson, B. N., Mutharasan, R. (2012): Biosensing using dynamic-mode cantilever sensors: a review. Biosens. Bioelectron., 32(1), 1\u201318. https:\/\/doi.org\/10.1016\/j.bios.2011.10.054.","journal-title":"Biosens. Bioelectron."},{"issue":"7","key":"794_CR10","doi-asserted-by":"publisher","first-page":"2229","DOI":"10.1063\/1.1763252","volume":"75","author":"N. V. Lavrik","year":"2004","unstructured":"Lavrik, N. V., Sepaniak, M. J., Datskos, P. G. (2004): Cantilever transducers as a platform for chemical and biological sensors. Rev. Sci. Instrum., 75(7), 2229\u20132253. https:\/\/doi.org\/10.1063\/1.1763252.","journal-title":"Rev. Sci. Instrum."},{"issue":"7\u20138","key":"794_CR11","doi-asserted-by":"publisher","first-page":"946","DOI":"10.1007\/s00216-004-2694-y","volume":"379","author":"C. Ziegler","year":"2004","unstructured":"Ziegler, C. (2004): Cantilever-based biosensors. Anal. Bioanal. Chem., 379(7\u20138), 946\u2013959. https:\/\/doi.org\/10.1007\/s00216-004-2694-y.","journal-title":"Anal. Bioanal. Chem."},{"issue":"22","key":"794_CR12","doi-asserted-by":"publisher","DOI":"10.1088\/0953-8984\/20\/22\/225012","volume":"20","author":"Y. Song","year":"2008","unstructured":"Song, Y., Bhushan, B. (2008): Atomic force microscopy dynamic modes: modeling and applications. J. Phys. Condens. Matter, 20(22), 225012. https:\/\/doi.org\/10.1088\/0953-8984\/20\/22\/225012.","journal-title":"J. Phys. Condens. Matter"},{"issue":"1","key":"794_CR13","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.snb.2012.01.035","volume":"164","author":"L. A. Beardslee","year":"2012","unstructured":"Beardslee, L. A., Josse, F., Heinrich, S. M., Dufour, I., Brand, O. (2012): Geometrical considerations for the design of liquid-phase biochemical sensors using a cantilever\u2019s fundamental in-plane mode. Sens. Actuators B, Chem., 164(1), 7\u201314. https:\/\/doi.org\/10.1016\/j.snb.2012.01.035.","journal-title":"Sens. Actuators B, Chem."},{"issue":"2","key":"794_CR14","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1109\/JMEMS.2008.916328","volume":"17","author":"J. H. Seo","year":"2008","unstructured":"Seo, J. H., Brand, O. (2008): High Q-factor in-plane-mode resonant microsensor platform for gaseous\/liquid environment. J. Microelectromech. Syst., 17(2), 483\u2013493. https:\/\/doi.org\/10.1109\/JMEMS.2008.916328.","journal-title":"J. Microelectromech. Syst."},{"key":"794_CR15","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.snb.2014.04.048","volume":"200","author":"M. Kucera","year":"2014","unstructured":"Kucera, M., et al. (2014): Design-dependent performance of self-actuated and self-sensing piezoelectric-AlN cantilevers in liquid media oscillating in the fundamental in-plane bending mode. Sens. Actuators B, Chem., 200, 235\u2013244. https:\/\/doi.org\/10.1016\/j.snb.2014.04.048.","journal-title":"Sens. Actuators B, Chem."},{"issue":"8","key":"794_CR16","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/23\/8\/085009","volume":"23","author":"M. Kucera","year":"2013","unstructured":"Kucera, M., Manzaneque, T., S\u00e1nchez-Rojas, J. L., Bittner, A., Schmid, U. (2013): Q-factor enhancement for self-actuated self-sensing piezoelectric MEMS resonators applying a lock-in driven feedback loop. J. Micromech. Microeng., 23(8), 085009. https:\/\/doi.org\/10.1088\/0960-1317\/23\/8\/085009.","journal-title":"J. Micromech. Microeng."},{"issue":"23","key":"794_CR17","doi-asserted-by":"publisher","DOI":"10.1063\/1.4882177","volume":"104","author":"M. Kucera","year":"2014","unstructured":"Kucera, M., et al. (2014): Characterization of a roof tile-shaped out-of-plane vibrational mode in aluminum-nitride-actuated self-sensing micro-resonators for liquid monitoring purposes. Appl. Phys. Lett., 104(23), 233501. https:\/\/doi.org\/10.1063\/1.4882177.","journal-title":"Appl. Phys. Lett."},{"issue":"5","key":"794_CR18","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1007\/s00542-009-1015-y","volume":"16","author":"J. Hernando","year":"2010","unstructured":"Hernando, J., et al. (2010): Characterization and displacement control of low surface-stress AlN-based piezoelectric micro-resonators. Microsyst. Technol., 16(5), 855\u2013861. https:\/\/doi.org\/10.1007\/s00542-009-1015-y.","journal-title":"Microsyst. Technol."},{"issue":"5","key":"794_CR19","doi-asserted-by":"publisher","DOI":"10.1063\/1.4928429","volume":"107","author":"M. Kucera","year":"2015","unstructured":"Kucera, M., et al. (2015): Characterisation of multi roof tile-shaped out-of-plane vibrational modes in aluminium-nitride-actuated self-sensing micro-resonators in liquid media. Appl. Phys. Lett., 107(5), 053506. https:\/\/doi.org\/10.1063\/1.4928429.","journal-title":"Appl. Phys. Lett."},{"issue":"5","key":"794_CR20","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/20\/5\/055027","volume":"20","author":"J. L. Sanchez-Rojas","year":"2010","unstructured":"Sanchez-Rojas, J. L., et al. (2010): Modal optimization and filtering in piezoelectric microplate resonators. J. Micromech. Microeng., 20(5), 055027. https:\/\/doi.org\/10.1088\/0960-1317\/20\/5\/055027.","journal-title":"J. Micromech. Microeng."},{"key":"794_CR21","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.snb.2016.02.029","volume":"237","author":"G. Pfusterschmied","year":"2016","unstructured":"Pfusterschmied, G., et al. (2016): Roof tile-shaped modes in quasi free-free supported piezoelectric microplate resonators in high viscous fluids. Sens. Actuators B, Chem., 237, 999\u20131006. https:\/\/doi.org\/10.1016\/j.snb.2016.02.029.","journal-title":"Sens. Actuators B, Chem."},{"issue":"7","key":"794_CR22","doi-asserted-by":"publisher","first-page":"200","DOI":"10.3390\/mi8070200","volume":"8","author":"G. Pfusterschmied","year":"2017","unstructured":"Pfusterschmied, G., et al. (2017): Potential of piezoelectric MEMS resonators for grape must fermentation monitoring. Micromachines, 8(7), 200. https:\/\/doi.org\/10.3390\/mi8070200.","journal-title":"Micromachines"},{"issue":"10","key":"794_CR23","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/25\/10\/105014","volume":"25","author":"G. Pfusterschmied","year":"2015","unstructured":"Pfusterschmied, G., et al. (2015): Temperature dependent performance of piezoelectric MEMS resonators for viscosity and density determination of liquids. J. Micromech. Microeng., 25(10), 105014. https:\/\/doi.org\/10.1088\/0960-1317\/25\/10\/105014.","journal-title":"J. Micromech. Microeng."},{"key":"794_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2019.126957","volume":"299","author":"F. Patocka","year":"2019","unstructured":"Patocka, F., et al. (2019): Piezoelectrically excited MEMS sensor with integrated planar coil for the detection of ferrous particles in liquids. Sens. Actuators B, Chem., 299, 126957. https:\/\/doi.org\/10.1016\/j.snb.2019.126957.","journal-title":"Sens. Actuators B, Chem."},{"key":"794_CR25","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1109\/MEMSYS.2019.8870897","volume-title":"Proceedings of the IEEE international conference on micro electro mechanical systems (MEMS)","author":"G. Pfusterschmied","year":"2019","unstructured":"Pfusterschmied, G., et al. (2019): Sensing fluid properties of super high viscous liquids using non-conventional vibration modes in piezoelectrically excited MEMS resonators. In Proceedings of the IEEE international conference on micro electro mechanical systems (MEMS) (pp. 735\u2013738). https:\/\/doi.org\/10.1109\/MEMSYS.2019.8870897."},{"key":"794_CR26","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/874086","volume":"2012","author":"J. Jensen","year":"2012","unstructured":"Jensen, J., Farina, M., Zuccheri, G., Grange, W., Hegner, M. (2012): Quantitative, label-free detection of the aggregation of $\\alpha $-synuclein using microcantilever arrays operated in a liquid environment. J. Sens., 2012, 874086. https:\/\/doi.org\/10.1155\/2012\/874086.","journal-title":"J. Sens."},{"key":"794_CR27","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.sna.2012.05.036","volume":"182","author":"Y. C. Tseng","year":"2012","unstructured":"Tseng, Y. C., Chang, J. S., Lin, S., Chao, S. D., Liu, C. H. (2012): 3,4-Methylenedioxymethylamphetamine detection using a microcantilever-based biosensor. Sens. Actuators A, Phys., 182, 163\u2013167. https:\/\/doi.org\/10.1016\/j.sna.2012.05.036.","journal-title":"Sens. Actuators A, Phys."}],"container-title":["e &amp; i Elektrotechnik und Informationstechnik"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-020-00794-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s00502-020-00794-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-020-00794-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T23:45:13Z","timestamp":1617839113000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s00502-020-00794-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,8]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020,6]]}},"alternative-id":["794"],"URL":"https:\/\/doi.org\/10.1007\/s00502-020-00794-w","relation":{},"ISSN":["0932-383X","1613-7620"],"issn-type":[{"value":"0932-383X","type":"print"},{"value":"1613-7620","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,8]]},"assertion":[{"value":"30 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}