{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:45:36Z","timestamp":1740145536424,"version":"3.37.3"},"reference-count":6,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T00:00:00Z","timestamp":1644969600000},"content-version":"vor","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008332","name":"Graz University of Technology","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008332","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Elektrotech. Inftech."],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>Bei Erdschl\u00fcssen an Mittelspannungskabeln k\u00f6nnen in unmittelbarer Umgebung der Fehlerstelle durch den Eintritt von Str\u00f6men in das Erdreich Potentialanhebungen und somit Schritt- und Ber\u00fchrungsspannungen auftreten. Diese m\u00fcssen hinsichtlich des Risikos einer Personengef\u00e4hrdung betrachtet werden. Eine besondere Situation entsteht dabei, wenn der Fehler im Nahbereich eines Swimmingpools auftritt, da sich hier Personen barfu\u00df aufhalten k\u00f6nnen. Die dabei kleineren \u00dcbergangswiderst\u00e4nde zum Erdreich als bei Personen mit Schuhwerk f\u00fchren zu gr\u00f6\u00dferen K\u00f6rperstr\u00f6men. Diese Situation wird unter Ber\u00fccksichtigung der einschl\u00e4gigen Normen auf ihr Gef\u00e4hrdungspotential beurteilt.<\/jats:p><jats:p>Im Zentrum dieses Fachbeitrages steht die Frage, unter welchen Bedingungen es bei der Ann\u00e4herung von Swimmingpool und erdverlegtem Kabel bei einem Erdschluss in kompensierten Mittelspannungsnetzen (20\u202fkV und 30\u202fkV) zu einer Personengef\u00e4hrdung kommen kann und welche Ma\u00dfnahmen von den Betreibern dieser Kabel erforderlichenfalls zu treffen sind.<\/jats:p><jats:p>Zwei unterschiedliche Fehlerszenarien werden im Detail analysiert: ein Kabelfehler in der N\u00e4he eines Swimmingpools sowie ein Fehler im Bereich eines Kabelauff\u00fchrungsmastes oder in einer Ortsnetzstation mit Potentialverschleppung \u00fcber den Kabelbegleiterder.<\/jats:p><jats:p>Die wesentlichen Einflussparameter werden hinsichtlich der Auswirkungen auf den Fehlerstrom sowie auf Schritt- und Ber\u00fchrungsspannungen untersucht.<\/jats:p><jats:p>Aus den Untersuchungen geht hervor, dass bei den meisten betrachteten Fehlerszenarien keine Gef\u00e4hrdung f\u00fcr Personen hinsichtlich Schritt- und Ber\u00fchrungsspannungen zu erwarten ist. Einzig der Fehlerfall mit Potentialverschleppung \u00fcber den Kabelbegleiterder in Gebieten mit spezifischen Bodenwiderst\u00e4nden von gr\u00f6\u00dfer als 1000\u202f\u2126m muss im Anlassfall gepr\u00fcft werden.<\/jats:p>","DOI":"10.1007\/s00502-022-00995-5","type":"journal-article","created":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T09:04:00Z","timestamp":1645002240000},"page":"52-64","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Erdschl\u00fcsse bei Mittelspannungskabeln und die elektrische Beeinflussung im Bereich von Swimmingpools","Earth faults in medium voltage cables and the electrical interference in the vicinity of swimming pools"],"prefix":"10.1007","volume":"139","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3939-8960","authenticated-orcid":false,"given":"Katrin","family":"Friedl","sequence":"first","affiliation":[]},{"given":"Reinhard","family":"Hirtler","sequence":"additional","affiliation":[]},{"given":"Lothar","family":"Fickert","sequence":"additional","affiliation":[]},{"given":"Ren\u00e9","family":"Braunstein","sequence":"additional","affiliation":[]},{"given":"Robert","family":"Sch\u00fcrhuber","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2022,2,16]]},"reference":[{"key":"995_CR1","volume-title":"Beeinflussung von Fernmeldeanlagen durch Wechselstromanlagen mit Nennspannungen \u00fcber 1\u202fkV","author":"\u00d6VE B 1:1976","year":"1976","unstructured":"\u00d6VE B 1:1976 (1976) Beeinflussung von Fernmeldeanlagen durch Wechselstromanlagen mit Nennspannungen \u00fcber 1\u202fkV. OVE, Wien"},{"key":"995_CR2","volume-title":"Erdung von Starkstromanlagen mit Nennwechselspannungen \u00fcber 1\u202fkV","author":"\u00d6VE\/\u00d6NORM EN 50522","year":"2011","unstructured":"\u00d6VE\/\u00d6NORM EN 50522 (2011) Erdung von Starkstromanlagen mit Nennwechselspannungen \u00fcber 1\u202fkV. OVE, Wien"},{"key":"995_CR3","volume-title":"2018, Effects of current on human beings and livestock\u2014Part 1: General aspects","author":"IEC 60479-1","year":"2018","unstructured":"IEC 60479\u20111 (2018) 2018, Effects of current on human beings and livestock\u2014Part 1: General aspects"},{"key":"995_CR4","volume-title":"Erdungen in Wechselstromanlagen mit Nennspannungen \u00fcber 1\u202fkV","author":"\u00d6VE-EH 41","year":"1987","unstructured":"\u00d6VE-EH 41 (1987) Erdungen in Wechselstromanlagen mit Nennspannungen \u00fcber 1\u202fkV. \u00d6VE, Wien"},{"key":"995_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-0348-6873-0","volume-title":"Erdstr\u00f6me","author":"F Ollendorff","year":"1969","unstructured":"Ollendorff\u00a0F (1969) Erdstr\u00f6me. Birkh\u00e4user, Basel"},{"key":"995_CR6","volume-title":"XGSLab TM UserGuide (Release 9.6.1-02\/21), Bassano del Grappa, Italy","author":"S Srl","year":"2021","unstructured":"Srl\u00a0S (2021) XGSLab TM UserGuide (Release 9.6.1-02\/21), Bassano del Grappa, Italy"}],"container-title":["e &amp; i Elektrotechnik und Informationstechnik"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-022-00995-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00502-022-00995-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-022-00995-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,14]],"date-time":"2022-03-14T12:31:51Z","timestamp":1647261111000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00502-022-00995-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["995"],"URL":"https:\/\/doi.org\/10.1007\/s00502-022-00995-5","relation":{},"ISSN":["0932-383X","1613-7620"],"issn-type":[{"type":"print","value":"0932-383X"},{"type":"electronic","value":"1613-7620"}],"subject":[],"published":{"date-parts":[[2022,2]]},"assertion":[{"value":"3 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 November 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}