{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:45:35Z","timestamp":1740145535818,"version":"3.37.3"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T00:00:00Z","timestamp":1644969600000},"content-version":"vor","delay-in-days":15,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100008332","name":"Graz University of Technology","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008332","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Elektrotech. Inftech."],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>Stabilit\u00e4tsuntersuchungen sind seit Langem ein wichtiges Thema im Netzbetrieb und helfen, einen sicheren Betrieb des Netzes zu gew\u00e4hrleisten. Methoden zur Verifikation der Stabilit\u00e4t sind in den Netzanschlussbedingungen [1\u20137] definiert und umfassen unter anderem die \u00dcberpr\u00fcfung der Fault Ride Through(FRT)-F\u00e4higkeit von Stromerzeugungsanlagen, d.\u202fh. die F\u00e4higkeit der Anlagen, bei definierten Spannungseinbr\u00fcchen ohne Verlust ihrer Stabilit\u00e4t mit dem Netz verbunden zu bleiben. Diese Verifikation geschieht oft durch Simulation, bei gr\u00f6\u00dferen Anlagen (rund &gt;\u202f10\u202fMW) ist dies stets der Fall. Bei kleineren Anlagen ist es vor allem dann die \u00fcbliche Vorgehensweise, wenn es sich um eine projektspezifisch ausgelegte Anlage handelt, was etwa bei Wasserkraftanlagen den Regelfall darstellt. In der vorliegenden Arbeit werden verschiedene Methoden zur Untersuchung der FRT-F\u00e4higkeit analysiert. Es werden zwei verschiedene Ans\u00e4tze zum Erzeugen eines Spannungseinbruches \u00fcberpr\u00fcft, welche den FRT wesentlich beeinflussen und damit auch zu einem unterschiedlichen Anlagenverhalten f\u00fchren. Einerseits wird der Spannungseinbruch durch eine geregelte Fehlerimpedanz am Netzanschlusspunkt verursacht, andererseits erfolgt die Simulation eines Spannungseinbruches durch die Modifikation der das Netz darstellenden Ersatzspannungsquelle. Schlie\u00dflich werden im Artikel auch die Parameter der Ersatzschaltung identifiziert und analysiert, welche einen ma\u00dfgeblichen Einfluss auf die FRT-F\u00e4higkeit haben.<\/jats:p>","DOI":"10.1007\/s00502-022-00998-2","type":"journal-article","created":{"date-parts":[[2022,2,16]],"date-time":"2022-02-16T14:02:46Z","timestamp":1645020166000},"page":"73-87","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Untersuchung der FRT-F\u00e4higkeit eines Hydrogenerators unter besonderer Ber\u00fccksichtigung des Back-Swing-Effekts","Investigation of the FRT capability of a\u00a0hydro-generator with special consideration of the back-swing effect"],"prefix":"10.1007","volume":"139","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5357-978X","authenticated-orcid":false,"given":"Darko","family":"Brankovic","sequence":"first","affiliation":[]},{"given":"Robert","family":"Sch\u00fcrhuber","sequence":"additional","affiliation":[]},{"given":"Herwig","family":"Renner","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2022,2,16]]},"reference":[{"key":"998_CR1","unstructured":"E\u2011Control. https:\/\/www.e-control.at\/documents\/1785851\/1811582\/TOR+Erzeuger+Typ+A+V1.0.pdf\/6342d021-a5ce-3809-2ae5-28b78e26f04d?t=1562757767659 (Erstellt: 12. Dez. 2019). Zugegriffen: 20. Apr. 2021"},{"key":"998_CR2","unstructured":"E\u2011Control. https:\/\/www.e-control.at\/documents\/1785851\/1811582\/TOR+Erzeuger+Typ+B+V1.0.pdf\/a9a7e5ae-5842-caa9-d2c0-93be4b6e0802?t=1562757801048 (Erstellt: 12. Dez. 2019). Zugegriffen: 20. Apr. 2021"},{"key":"998_CR3","unstructured":"E\u2011Control. https:\/\/www.e-control.at\/documents\/1785851\/1811582\/TOR+Erzeuger+Typ+C+V1.0.pdf\/345d283b-6017-f58f-64fe-96029d31ba24?t=1562757831308 (Erstellt: 12. Dez. 2019). Zugegriffen: 20. Apr. 2021"},{"key":"998_CR4","unstructured":"E\u2011Control. https:\/\/www.e-control.at\/documents\/1785851\/1811582\/TOR+Erzeuger+Typ+D+V1.0.pdf\/ae8394df-60aa-5a4f-738e-a6df14a72541?t=1562757862259 (Erstellt: 12. Dez. 2019). Zugegriffen: 20. Apr. 2021"},{"key":"998_CR5","volume-title":"VDE-AR-N 4105 Anwendungsregel:2018-11 Erzeugungsanlagen am Niederspannungsnetz","author":"VDE","year":"2018","unstructured":"VDE (2018) VDE-AR\u2011N 4105 Anwendungsregel:2018-11 Erzeugungsanlagen am Niederspannungsnetz. VDE Verlag,"},{"key":"998_CR6","volume-title":"VDE-AR-N 4110 Anwendungsregel:2018-11","author":"VDE","year":"2018","unstructured":"VDE (2018) VDE-AR\u2011N 4110 Anwendungsregel:2018-11. VDE,"},{"key":"998_CR7","volume-title":"VDE-AR-N 4120 Anwendungsregel:2018-11","author":"VDE","year":"2018","unstructured":"VDE (2018) VDE-AR\u2011N 4120 Anwendungsregel:2018-11. VDE,"},{"key":"998_CR8","unstructured":"(2016) ENTSO\u2011E. https:\/\/eur-lex.europa.eu\/legal-content\/DE\/TXT\/HTML\/?uri=CELEX:32016R0631&from=EN. Zugegriffen: 20. Apr. 2021"},{"key":"998_CR9","unstructured":"DIgSILENT https:\/\/www.digsilent.de\/en\/powerfactory.html. Zugegriffen: 17. Sept. 2021"},{"issue":"8","key":"998_CR10","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1007\/s00502-014-0258-1","volume":"131","author":"N Essl","year":"2014","unstructured":"Essl\u00a0N, Renner\u00a0H (2014) Low-Voltage-Ride-Through-Assistenzsystem f\u00fcr dezentrale Erzeugungseinheiten. e&i-Elektrotechnik Informationstechnik 131(8):309\u2013315","journal-title":"e&i-Elektrotechnik Informationstechnik"},{"key":"998_CR11","volume-title":"Technical reference\u2014synchronous machine","author":"DIgSILENT","year":"2021","unstructured":"DIgSILENT (2021) Technical reference\u2014synchronous machine"},{"key":"998_CR12","unstructured":"Brankovic D Untersuchung der FRT-F\u00e4higkeit eines Hydrogenerators aufgrund der TOR-Richtlinien, Masterarbeit: Technische Universit\u00e4t Graz, 03.01.2021. https:\/\/www.tugraz.at\/fileadmin\/user_upload\/tugrazExternal\/83b7d5e5-91ff-43e4-aa7a-6aa30ac5c9f1\/Master_abgeschlossen\/Masterarbeit_Brankovic.pdf. Zugegriffen: 05.1120"},{"key":"998_CR13","volume-title":"Transient torque and load angle of a synchronous generators following","author":"DB Mehta","year":"1960","unstructured":"Mehta\u00a0DB, Adkins\u00a0B (1960) Transient torque and load angle of a synchronous generators following. The Institution of Electrical Engineers,"},{"key":"998_CR14","volume-title":"Dynamic behaviour of synchronous machines relating to LVRT requirements","author":"N Essl","year":"2016","unstructured":"Essl\u00a0N (2016) Dynamic behaviour of synchronous machines relating to LVRT requirements. Technische Universit\u00e4t Graz, Graz"}],"container-title":["e &amp; i Elektrotechnik und Informationstechnik"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-022-00998-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00502-022-00998-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-022-00998-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,14]],"date-time":"2022-03-14T12:31:45Z","timestamp":1647261105000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00502-022-00998-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["998"],"URL":"https:\/\/doi.org\/10.1007\/s00502-022-00998-2","relation":{},"ISSN":["0932-383X","1613-7620"],"issn-type":[{"type":"print","value":"0932-383X"},{"type":"electronic","value":"1613-7620"}],"subject":[],"published":{"date-parts":[[2022,2]]},"assertion":[{"value":"17 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 November 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}