{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:58:05Z","timestamp":1762869485321,"version":"3.37.3"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"7-8","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,10]],"date-time":"2024-12-10T00:00:00Z","timestamp":1733788800000},"content-version":"vor","delay-in-days":9,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100021130","name":"Bundesministerium f\u00fcr Wirtschaft und Klimaschutz","doi-asserted-by":"publisher","award":["03EI4060C"],"award-info":[{"award-number":["03EI4060C"]}],"id":[{"id":"10.13039\/100021130","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Helmut-Schmidt-Universit\u00e4t Universit\u00e4t der Bundeswehr Hamburg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Elektrotech. Inftech."],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:title>Zusammenfassung<\/jats:title><jats:p>Bisher werden Resonanzfaktoren auf der Grundlage verschiedener Annahmen ermittelt. Das kann zu einer \u00dcbersch\u00e4tzung dieser Faktoren f\u00fchren und somit die elektrische Charakteristik des Netzanschlusspunkts fehlerhaft abbilden. Dadurch kann es dazu kommen, dass Erzeugungsanlagen die Netzeinspeisung versagt wird, obwohl hierf\u00fcr bei genauerer Betrachtung keine sachliche Grundlage vorliegt. In diesem Beitrag wird gezeigt, wie man durch die Messung der Netzimpedanz am Verkn\u00fcpfungspunkt zu praktisch relevanten Bewertungen kommen kann. Hierf\u00fcr wird die Oberschwingungsbewertung im Netzanschlussprozess erl\u00e4utert und eine angepasste Bewertung anhand eines realen Fallbeispiels pr\u00e4sentiert. Dar\u00fcber hinaus werden die Resonanzfaktoren weiterer Netzanschlusspunkte auf der Basis realer Messungen ermittelt und miteinander verglichen. Anhand der Ergebnisse kann festgestellt werden, dass messwertbasierte Resonanzfaktoren in der Regel h\u00f6here Oberschwingungsstromgrenzwerte erlauben.<\/jats:p>","DOI":"10.1007\/s00502-024-01290-1","type":"journal-article","created":{"date-parts":[[2024,12,10]],"date-time":"2024-12-10T13:15:00Z","timestamp":1733836500000},"page":"476-483","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Ermittlung von Resonanzfaktoren zur Oberschwingungsbewertung nach VDE-AR-N 4110 basierend auf Netzimpedanzmessungen","Determination of resonance factors for harmonic assessment according to VDE-AR-N 4110 based on grid impedance measurements"],"prefix":"10.1007","volume":"141","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-0786-5813","authenticated-orcid":false,"given":"Johannes","family":"Schr\u00e4der","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc Florian","family":"Meyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"M\u00f6bius","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Detlef","family":"Schulz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Jordan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,12,10]]},"reference":[{"key":"1290_CR1","unstructured":"VDE AR\u2011N 4110, Technische Regeln f\u00fcr den Anschluss von Kundenanlagen an das Mittelspannungsnetz und deren Betrieb (TAR Mittelspannung), 2023"},{"key":"1290_CR2","doi-asserted-by":"publisher","DOI":"10.24405\/13957","volume-title":"Hamburger Beitr\u00e4ge zum Technischen Klimaschutz 3","author":"J Schr\u00e4der","year":"2021","unstructured":"Schr\u00e4der\u00a0J, Meyer\u00a0M F, M\u00f6bius\u00a0P, Schulz\u00a0D (2021) Optimierte Netzanschlussbewertung von Erneuerbaren Energieanlagen durch die Bewertung von Oberschwingungsemissionen mittels zeit- und frequenzabh\u00e4ngiger Netzimpedanzmessungen. In: Hamburger Beitr\u00e4ge zum Technischen Klimaschutz 3 Hamburg. https:\/\/doi.org\/10.24405\/13957"},{"key":"1290_CR3","volume-title":"NELEV, \u201eVerordnung zum Nachweis von elektrotechnischen Eigenschaften von Energieanlagen (Elektrotechnische-Eigenschaften-Nachweis-Verordnung \u2013 NELEV)\u201c","author":"Bundesamt f\u00fcr Justiz","year":"2017","unstructured":"Bundesamt f\u00fcr Justiz (2017) NELEV, \u201eVerordnung zum Nachweis von elektrotechnischen Eigenschaften von Energieanlagen (Elektrotechnische-Eigenschaften-Nachweis-Verordnung \u2013 NELEV)\u201c"},{"key":"1290_CR4","volume-title":"\u201eFlexNetz\u201c Erweiterung der Aufnahmef\u00e4higkeit von Verteilnetzen durch eine netzzustandsabh\u00e4ngige Netzanschlusskapazit\u00e4t. In: Tagung zuk\u00fcnftige Stromnetze","author":"O Br\u00fcckl","year":"2024","unstructured":"Br\u00fcckl\u00a0O, Bayer\u00a0J (2024) \u201eFlexNetz\u201c Erweiterung der Aufnahmef\u00e4higkeit von Verteilnetzen durch eine netzzustandsabh\u00e4ngige Netzanschlusskapazit\u00e4t. In: Tagung zuk\u00fcnftige Stromnetze. Berlin"},{"key":"1290_CR5","unstructured":"DIN EN 50160, Merkmale der Spannung in \u00f6ffentlichen Elektrizit\u00e4tsversorgungsnetzen, 2020"},{"key":"1290_CR6","doi-asserted-by":"publisher","DOI":"10.1109\/PVSC.2016.7749844","volume-title":"IEEE 43rd&nbsp;Photovoltaic Specialists Conference (PVSC)","author":"S Rogalla","year":"2016","unstructured":"Rogalla\u00a0S, Ackermann\u00a0F, Bihler\u00a0N, Stalter\u00a0O (2016) Source-driven and Resonance-driven Harmonic Interaction between PV Inverters and the Grid. In: IEEE 43rd\u00a0Photovoltaic Specialists Conference (PVSC) Portland. https:\/\/doi.org\/10.1109\/PVSC.2016.7749844"},{"key":"1290_CR7","volume-title":"Technische Richtlinien f\u00fcr Erzeugungseinheiten und -anlagen","author":"FGW e.\u202fV.","year":"2022","unstructured":"FGW e.\u202fV. (2022) Technische Richtlinien f\u00fcr Erzeugungseinheiten und -anlagen. FGW e.\u202fV., Berlin"},{"key":"1290_CR8","doi-asserted-by":"publisher","DOI":"10.36227\/techrxiv.19299479.v1","volume-title":"PESS + PELSS","author":"K M Boroujeni","year":"2022","unstructured":"Boroujeni\u00a0K M, Safargholi\u00a0F, Malekian\u00a0K (2022) Distinction between \u201cdestructive\u201d and \u201cconstructive\u201d harmonic currents to the voltage quality. In: PESS + PELSS https:\/\/doi.org\/10.36227\/techrxiv.19299479.v1"},{"key":"1290_CR9","volume-title":"Technische Regeln f\u00fcr die Beurteilung von Netzr\u00fcckwirkungen, Teil&nbsp;A:&nbsp;Grundlagen","author":"P Bader","year":"2021","unstructured":"Bader\u00a0P, D\u00fcrr\u00a0M, Fahmberger\u00a0M, Gr\u00e4nicher\u00a0T, Hanzlik\u00a0T, H\u00f6ckel\u00a0M, Holenstein\u00a0H, Mercker\u00a0M, Meyer\u00a0J, Mombauer\u00a0W, Niederhuemer\u00a0W, Quadflieg\u00a0D, Scheida\u00a0K, Schober\u00a0L, Schocke\u00a0M, V\u00f6llmin\u00a0B, Winkler\u00a0G (2021) Technische Regeln f\u00fcr die Beurteilung von Netzr\u00fcckwirkungen, Teil\u00a0A:\u00a0Grundlagen. \u00d6sterreichs E\u2011Wirtschaft, VSE, CSRES, VDE FFN."},{"key":"1290_CR10","volume-title":"Erg\u00e4nzungsdokument zur Beurteilung von Anlagen f\u00fcr den Anschluss an Hochspannungsverteilernetze","author":"U Ammeter","year":"2012","unstructured":"Ammeter\u00a0U, Gr\u00e4nicher\u00a0T, Hanzlik\u00a0J, Holenstein\u00a0H, Mercker\u00a0M, Meyer\u00a0J, Mombauer\u00a0W, Niederhuemer\u00a0W, Pascoli\u00a0G, Quadflieg\u00a0D, Schocke\u00a0M, Winkler\u00a0G, Zierlinger\u00a0J (2012) Erg\u00e4nzungsdokument zur Beurteilung von Anlagen f\u00fcr den Anschluss an Hochspannungsverteilernetze. \u00d6sterreichs E\u2011Wirtschaft, VSE, CSRES, FNN."},{"key":"1290_CR11","doi-asserted-by":"crossref","unstructured":"Schr\u00e4der J, Meyer M F, Jordan M, Schulz D (2024) Survey of harmonic grid impedance measurements on the medium voltage level up to 100\u202fkHz. Eingereicht: IEEE Access PES","DOI":"10.1109\/ACCESS.2024.3509273"},{"key":"1290_CR12","doi-asserted-by":"publisher","DOI":"10.24405\/16726","volume-title":"Data set: Measurements of the positive sequence impedance of eleven measurement sites from 2016 to 2024","author":"J Schr\u00e4der","year":"2024","unstructured":"Schr\u00e4der\u00a0J, Meyer\u00a0M F, Jordan\u00a0M (2024) Data set: Measurements of the positive sequence impedance of eleven measurement sites from 2016 to 2024. Helmut-Schmidt-Universit\u00e4t https:\/\/doi.org\/10.24405\/16726"},{"key":"1290_CR13","volume-title":"International ETG Congress","author":"M Jordan","year":"2017","unstructured":"Jordan\u00a0M, Meyer\u00a0M F, Kaatz\u00a0G, Schulz\u00a0D (2017) Harmonic network impedance measurement and modelling on the medium voltage level. In: International ETG Congress Bonn"},{"key":"1290_CR14","volume-title":"Roadmap Systemstabilit\u00e4t, Fahrplan zur Erreichung eines sicheren und robusten Betriebs des zuk\u00fcnftigen Stromversorgungssystems mit 100\u202f% erneuerbaren Energien","author":"BMWK","year":"2023","unstructured":"BMWK (2023) Roadmap Systemstabilit\u00e4t, Fahrplan zur Erreichung eines sicheren und robusten Betriebs des zuk\u00fcnftigen Stromversorgungssystems mit 100\u202f% erneuerbaren Energien. Bundesministerium f\u00fcr Wirtschaft und Klimaschutz (BMWK), Berlin"},{"key":"1290_CR15","unstructured":"VDE, FAQ zur TAR Mittelspannung, https:\/\/www.vde.com\/de\/fnn\/themen\/tar\/tar-mittelspannung-vde-ar-n-4110. Zugegriffen: 27. Febr. 2024"},{"key":"1290_CR16","doi-asserted-by":"publisher","DOI":"10.24405\/16727","volume-title":"Data set: Impedance measurement data at the grid connection point of an ORC (Organic Rankine Cycle) system, measured in February 2024","author":"J Schr\u00e4der","year":"2024","unstructured":"Schr\u00e4der\u00a0J, Jordan\u00a0M (2024) Data set: Impedance measurement data at the grid connection point of an ORC (Organic Rankine Cycle) system, measured in February 2024. Helmut-Schmidt-Universit\u00e4t https:\/\/doi.org\/10.24405\/16727"}],"container-title":["e+i Elektrotechnik und Informationstechnik"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-024-01290-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s00502-024-01290-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s00502-024-01290-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,20]],"date-time":"2024-12-20T14:05:41Z","timestamp":1734703541000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s00502-024-01290-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":16,"journal-issue":{"issue":"7-8","published-print":{"date-parts":[[2024,12]]}},"alternative-id":["1290"],"URL":"https:\/\/doi.org\/10.1007\/s00502-024-01290-1","relation":{},"ISSN":["0932-383X","1613-7620"],"issn-type":[{"type":"print","value":"0932-383X"},{"type":"electronic","value":"1613-7620"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"9 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}