{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:27:53Z","timestamp":1786980473836,"version":"build-2736575974"},"reference-count":54,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T00:00:00Z","timestamp":1704412800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T00:00:00Z","timestamp":1704412800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Virtual Reality"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Spatially dependent veiling glare in medical extended reality (MXR) degrades image quality and needs to be characterized across technologies. Measurement methods of veiling glare on virtual and augmented reality (VR and AR) head-mounted displays (HMDs) have not been established in regulatory evaluation of MXR devices or display measurement standards. We describe an experimental bench setup enabling highly flexible translations and rotations of the light measuring device in five degrees of freedom within the eye box. Glare point spread functions (PSFs) of multiple VR and AR headsets are extracted and compared across the display field of view (FOV) in dark environment. At the center, the evaluated VR headsets (HTC VIVE Pro and VIVE Pro 2) demonstrate reduced long-range glare compared to the tested AR HMDs (Microsoft HoloLens 2 and Epson Moverio BT-300). The measured PSFs at multiple locations are spatially invariant for the HoloLens 2. However, veiling glare on the evaluated VR HMDs substantially increases toward the periphery of the FOV primarily due to optical aberration. For VR devices in medical use, increased peripheral glare can lead to image quality degradation and poor visualization of anatomical details.<\/jats:p>","DOI":"10.1007\/s10055-023-00893-x","type":"journal-article","created":{"date-parts":[[2024,1,5]],"date-time":"2024-01-05T11:02:27Z","timestamp":1704452547000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Spatially dependent veiling glare degrades image quality in medical extended reality"],"prefix":"10.1007","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6549-2208","authenticated-orcid":false,"given":"Chumin","family":"Zhao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Beams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eshan","family":"Dahal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aldo","family":"Badano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,5]]},"reference":[{"issue":"4","key":"893_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1145\/3127589","volume":"14","author":"R Albert","year":"2017","unstructured":"Albert R, Patney A, Luebke D et al (2017) Latency requirements for foveated rendering in virtual reality. ACM Trans Appl Percept (TAP) 14(4):1\u201313","journal-title":"ACM Trans Appl Percept (TAP)"},{"issue":"13","key":"893_CR2","doi-asserted-by":"publisher","first-page":"2059","DOI":"10.1364\/AO.39.002059","volume":"39","author":"A Badano","year":"2000","unstructured":"Badano A, Flynn MJ (2000) Method for measuring veiling glare in high-performance display devices. Appl Opt 39(13):2059\u20132066","journal-title":"Appl Opt"},{"key":"893_CR3","doi-asserted-by":"crossref","unstructured":"Badano A, Flynn MJ, Muka E et\u00a0al (1999) Veiling glare point-spread function of medical imaging monitors. In: Medical imaging 1999: image display, SPIE, pp 458\u2013467","DOI":"10.1117\/12.349458"},{"key":"893_CR4","doi-asserted-by":"crossref","unstructured":"Bader A, Badano A, Beams R (2022) Quadrant detector-based method for eye point alignment of augmented and virtual reality head mounted displays. In: Proc. of SPIE, p 119310A","DOI":"10.1117\/12.2614415"},{"issue":"18","key":"893_CR5","doi-asserted-by":"publisher","first-page":"24877","DOI":"10.1364\/OE.27.024877","volume":"27","author":"R Beams","year":"2019","unstructured":"Beams R, Kim AS, Badano A (2019) Transverse chromatic aberration in virtual reality head-mounted displays. Opt Express 27(18):24877\u201324884","journal-title":"Opt Express"},{"key":"893_CR6","doi-asserted-by":"crossref","unstructured":"Beams R, Collins B, Kim AS et\u00a0al (2020a) Angular dependence of the spatial resolution in virtual reality displays. In: 2020 IEEE Conference on virtual reality and 3D user interfaces (VR), IEEE, pp 836\u2013841","DOI":"10.1109\/VR46266.2020.00108"},{"key":"893_CR7","doi-asserted-by":"crossref","unstructured":"Beams R, Kim AS, Badano A (2020b) Eyebox centering using chromatic aberrations of virtual reality head-mounted displays. In: Optical architectures for displays and sensing in augmented, virtual, and mixed reality (AR, VR, MR), international society for optics and photonics, p 1131009","DOI":"10.1117\/12.2543257"},{"key":"893_CR8","doi-asserted-by":"crossref","unstructured":"Becker ME (2017) 62-2: Invited paper: Measurement of visual resolution of display screens. In: SID symposium digest of technical papers, Wiley Online Library, pp 915\u2013918","DOI":"10.1002\/sdtp.11784"},{"issue":"12","key":"893_CR9","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1038\/nrn3122","volume":"12","author":"CJ Bohil","year":"2011","unstructured":"Bohil CJ, Alicea B, Biocca FA (2011) Virtual reality in neuroscience research and therapy. Nat Rev Neurosci 12(12):752\u2013762","journal-title":"Nat Rev Neurosci"},{"issue":"5","key":"893_CR10","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1109\/JDT.2013.2279933","volume":"10","author":"M Choi","year":"2014","unstructured":"Choi M, Wang J, Cheng WC et al (2014) Effect of veiling glare on detectability in high-dynamic-range medical images. J Disp Technol 10(5):420\u2013428","journal-title":"J Disp Technol"},{"key":"893_CR11","doi-asserted-by":"crossref","unstructured":"Dahal E, Eby N, Lemaillet P et\u00a0al (2022) Head-mounted display luminance characterization for medical virtual reality. In: Optical architectures for displays and sensing in augmented, virtual, and mixed reality (AR, VR, MR) III, international society for oand photonics, vol PC11931. SPIE","DOI":"10.1117\/12.2613053"},{"issue":"5","key":"893_CR12","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1364\/OPTCON.486520","volume":"2","author":"E Dahal","year":"2023","unstructured":"Dahal E, Eby N, Lemaillet P et al (2023) Method for characterizing small-spot luminance in medical virtual reality headsets. Opt Contin 2(5):1180\u20131190","journal-title":"Opt Contin"},{"issue":"4","key":"893_CR13","doi-asserted-by":"publisher","first-page":"29","DOI":"10.3390\/mti1040029","volume":"1","author":"DB Douglas","year":"2017","unstructured":"Douglas DB, Wilke CA, Gibson JD et al (2017) Augmented reality: advances in diagnostic imaging. Multimodal Technol Interact 1(4):29","journal-title":"Multimodal Technol Interact"},{"key":"893_CR14","doi-asserted-by":"crossref","unstructured":"Draper RS, Penczek J, Varshneya R et\u00a0al (2018) 72-2: Standardizing fundamental criteria for near eye display optical measurements: Determining eye point position. In: SID symposium digest of technical papers, Wiley Online Library, pp 961\u2013964","DOI":"10.1002\/sdtp.12209"},{"issue":"2","key":"893_CR15","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1109\/MNET.2018.1700268","volume":"32","author":"MS Elbamby","year":"2018","unstructured":"Elbamby MS, Perfecto C, Bennis M et al (2018) Toward low-latency and ultra-reliable virtual reality. IEEE Netw 32(2):78\u201384","journal-title":"IEEE Netw"},{"issue":"2","key":"893_CR16","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1007\/BF03168843","volume":"12","author":"MJ Flynn","year":"1999","unstructured":"Flynn MJ, Badano A (1999) Image quality degradation by light scattering in display devices. J Digit Imaging 12(2):50\u201359","journal-title":"J Digit Imaging"},{"issue":"6","key":"893_CR17","doi-asserted-by":"publisher","first-page":"1653","DOI":"10.1148\/radiographics.19.6.g99no081653","volume":"19","author":"MJ Flynn","year":"1999","unstructured":"Flynn MJ, Kanicki J, Badano A et al (1999) High-fidelity electronic display of digital radiographs. Radiographics 19(6):1653\u20131669","journal-title":"Radiographics"},{"issue":"3","key":"893_CR18","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/MOO.0b013e32814b0802","volume":"15","author":"MP Fried","year":"2007","unstructured":"Fried MP, Uribe JI, Sadoughi B (2007) The role of virtual reality in surgical training in otorhinolaryngology. Current Opin Otolaryngol Head Neck Surg 15(3):163\u2013169","journal-title":"Current Opin Otolaryngol Head Neck Surg"},{"issue":"10","key":"893_CR19","doi-asserted-by":"publisher","first-page":"2962","DOI":"10.3390\/s20102962","volume":"20","author":"S Gonz\u00e1lez Izard","year":"2020","unstructured":"Gonz\u00e1lez Izard S, S\u00e1nchez Torres R, Alonso Plaza O et al (2020) Nextmed: automatic imaging segmentation, 3D reconstruction, and 3D model visualization platform using augmented and virtual reality. Sensors 20(10):2962","journal-title":"Sensors"},{"issue":"2","key":"893_CR20","doi-asserted-by":"publisher","first-page":"133","DOI":"10.3348\/kjr.2019.0625","volume":"21","author":"HW Goo","year":"2020","unstructured":"Goo HW, Park SJ, Yoo SJ (2020) Advanced medical use of three-dimensional imaging in congenital heart disease: augmented reality, mixed reality, virtual reality, and three-dimensional printing. Korean J Radiol 21(2):133\u2013145","journal-title":"Korean J Radiol"},{"key":"893_CR21","unstructured":"IEC 63145\u201320-10:2019, (2019) Eyewear display\u2014part 20\u201310: Fundamental measurement methods\u2014optical properties. Standard, international electrotechnical commission, Geneva, CH"},{"key":"893_CR22","unstructured":"ISO 9358:1994 (1994) Optics and optical instruments\u2014veiling glare of image forming systems\u2014definitions and methods of measurement. Standard, international organization for standardization, Geneva, CH"},{"issue":"3","key":"893_CR23","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1109\/TITB.2002.802374","volume":"6","author":"DP Jang","year":"2002","unstructured":"Jang DP, Ku JH, Choi YH et al (2002) The development of virtual reality therapy (VRT) system for the treatment of acrophobia and therapeutic case. IEEE Trans Inf Technol Biomed 6(3):213\u2013217","journal-title":"IEEE Trans Inf Technol Biomed"},{"key":"893_CR24","doi-asserted-by":"crossref","unstructured":"Johnson M, Zhao C, Varshney A et\u00a0al (2022) Digital precompensation for luminance nonuniformities in augmented reality head mounted displays. In: 2022 IEEE international symposium on mixed and augmented reality adjunct (ISMAR-Adjunct), IEEE, pp 477\u2013482","DOI":"10.1109\/ISMAR-Adjunct57072.2022.00100"},{"issue":"1","key":"893_CR25","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s10278-020-00392-4","volume":"34","author":"AS Kim","year":"2021","unstructured":"Kim AS, Cheng WC, Beams R et al (2021a) Color rendering in medical extended-reality applications. J Digit Imaging 34(1):16\u201326","journal-title":"J Digit Imaging"},{"key":"893_CR26","doi-asserted-by":"crossref","unstructured":"Kim AS, Cheng WC, Beams R et\u00a0al (2021b) Spatiotemporal characteristics of medical extended-reality systems. In: Medical imaging 2021: Image perception, observer performance, and technology assessment, international society for and photonics, p 1159906","DOI":"10.1117\/12.2580736"},{"key":"893_CR27","doi-asserted-by":"crossref","unstructured":"Kress BC (2019) Digital optical elements and technologies (edo19): applications to AR\/VR\/MR. In: Digital optical technologies 2019, SPIE, pp 343\u2013355","DOI":"10.1117\/12.2544404"},{"issue":"1","key":"893_CR28","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1515\/nanoph-2020-0410","volume":"10","author":"BC Kress","year":"2021","unstructured":"Kress BC, Chatterjee I (2021) Waveguide combiners for mixed reality headsets: a nanophotonics design perspective. Nanophotonics 10(1):41\u201374","journal-title":"Nanophotonics"},{"key":"893_CR29","doi-asserted-by":"crossref","unstructured":"Krupinski EA, Johnson J, Roehrig H et\u00a0al (2004) Use of a human visual system model to predict the effects of display veiling glare on observer performance. In: Medical imaging 2004: image perception, observer performance, and technology assessment, SPIE, pp 423\u2013429","DOI":"10.1117\/12.532361"},{"key":"893_CR30","doi-asserted-by":"crossref","unstructured":"Livingston MA, Gabbard JL, Swan JE et\u00a0al (2013) Basic perception in head-worn augmented reality displays. In: Human factors in augmented reality environments. Springer, pp 35\u201365","DOI":"10.1007\/978-1-4614-4205-9_3"},{"issue":"1","key":"893_CR31","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1007\/s11517-018-1861-9","volume":"57","author":"L Ma","year":"2019","unstructured":"Ma L, Jiang W, Zhang B et al (2019) Augmented reality surgical navigation with accurate CBCT-patient registration for dental implant placement. Med Biol Eng Comput 57(1):47\u201357","journal-title":"Med Biol Eng Comput"},{"issue":"8","key":"893_CR32","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1016\/j.cpr.2010.07.001","volume":"30","author":"KM Malloy","year":"2010","unstructured":"Malloy KM, Milling LS (2010) The effectiveness of virtual reality distraction for pain reduction: a systematic review. Clin Psychol Rev 30(8):1011\u20131018","journal-title":"Clin Psychol Rev"},{"key":"893_CR33","doi-asserted-by":"crossref","unstructured":"McCann JJ, Rizzi A (2007) Veiling glare: the dynamic range limit of HDR images. In: Human vision and electronic imaging XII, SPIE, pp 394\u2013403","DOI":"10.1117\/12.703042"},{"issue":"2","key":"893_CR34","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1007\/s10055-007-0080-8","volume":"12","author":"L Moody","year":"2008","unstructured":"Moody L, Waterworth A, McCarthy AD et al (2008) The feasibility of a mixed reality surgical training environment. Virtual Real 12(2):77\u201386","journal-title":"Virtual Real"},{"issue":"6","key":"893_CR35","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1089\/cyber.2014.0198","volume":"17","author":"JL Mosso-V\u00e1zquez","year":"2014","unstructured":"Mosso-V\u00e1zquez JL, Gao K, Wiederhold BK et al (2014) Virtual reality for pain management in cardiac surgery. Cyberpsychol Behav Soc Netw 17(6):371\u2013378","journal-title":"Cyberpsychol Behav Soc Netw"},{"issue":"3","key":"893_CR36","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1109\/TCE.2009.5278053","volume":"55","author":"J Park","year":"2009","unstructured":"Park J, Byun SC, Lee BU (2009) Lens distortion correction using ideal image coordinates. IEEE Trans Consum Electron 55(3):987\u2013991","journal-title":"IEEE Trans Consum Electron"},{"key":"893_CR37","doi-asserted-by":"crossref","unstructured":"Penczek J, Hasan M, Denning BS et\u00a0al (2019) 31-2: Measuring interocular geometric distortion of near-eye displays. In: SID symposium digest of technical papers, Wiley Online Library, pp 430\u2013433","DOI":"10.1002\/sdtp.12948"},{"key":"893_CR38","doi-asserted-by":"crossref","unstructured":"Penczek J, Austin RL, Hasan M et\u00a0al (2021) 51-2: Distinguished paper: measuring color capability of wide color gamut near-eye displays. In: SID symposium digest of technical papers, Wiley Online Library, pp 702\u2013705","DOI":"10.1002\/sdtp.14780"},{"key":"893_CR39","doi-asserted-by":"crossref","unstructured":"Petrak O, Schwarz F, Pohl L et al (2021) Laser beam scanning based AR-display applying resonant 2D mems mirrors. Optical architectures for displays and sensing in augmented, virtual, and mixed reality (AR, VR, MR) II, SPIE, pp 15\u201332","DOI":"10.1117\/12.2579695"},{"key":"893_CR40","unstructured":"Porsch T, Funke C, Schmidt F et\u00a0al (2015) Measurement of the unified glare rating (UGR) based on using ILMD. In: CIE Proc, pp 1471\u20131480"},{"issue":"1","key":"893_CR41","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41747-017-0033-2","volume":"2","author":"P Pratt","year":"2018","unstructured":"Pratt P, Ives M, Lawton G et al (2018) Through the hololens$$^{{\\rm TM}}$$ looking glass: augmented reality for extremity reconstruction surgery using 3D vascular models with perforating vessels. Eur Radiol Exp 2(1):1\u20137","journal-title":"Eur Radiol Exp"},{"key":"893_CR42","doi-asserted-by":"crossref","unstructured":"Ren D, Goldschwendt T, Chang Y et\u00a0al (2016) Evaluating wide-field-of-view augmented reality with mixed reality simulation. In: 2016 IEEE virtual reality (VR), IEEE, pp 93\u2013102","DOI":"10.1109\/VR.2016.7504692"},{"key":"893_CR43","doi-asserted-by":"crossref","unstructured":"Roehrig H, Fan J, Chawla A et\u00a0al (2002) The liquid crystal display (LCD) for medical imaging in comparison with the cathode ray tube display (CRT). In: Penetrating radiation systems and applications IV, SPIE, pp 114\u2013131","DOI":"10.1117\/12.456332"},{"issue":"4","key":"893_CR44","doi-asserted-by":"publisher","first-page":"1205","DOI":"10.1118\/1.1861159","volume":"32","author":"E Samei","year":"2005","unstructured":"Samei E, Badano A, Chakraborty D et al (2005) Assessment of display performance for medical imaging systems: executive summary of AAPM TG18 report. Med Phys 32(4):1205\u20131225","journal-title":"Med Phys"},{"issue":"12","key":"893_CR45","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1080\/17434440.2019.1693892","volume":"16","author":"S S\u0142yk","year":"2019","unstructured":"S\u0142yk S, Zarzycki MZ, Kocwa-Karna\u015b A et al (2019) Virtual reality in the diagnostics and therapy of neurological diseases. Expert Rev Med Devices 16(12):1035\u20131040","journal-title":"Expert Rev Med Devices"},{"issue":"1","key":"893_CR46","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1007\/s10278-018-0122-7","volume":"32","author":"J Sutherland","year":"2019","unstructured":"Sutherland J, Belec J, Sheikh A et al (2019) Applying modern virtual and augmented reality technologies to medical images and models. J Digit Imaging 32(1):38\u201353","journal-title":"J Digit Imaging"},{"issue":"3","key":"893_CR47","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1145\/1276377.1276424","volume":"26","author":"EV Talvala","year":"2007","unstructured":"Talvala EV, Adams A, Horowitz M et al (2007) Veiling glare in high dynamic range imaging. ACM Trans Gr (TOG) 26(3):37","journal-title":"ACM Trans Gr (TOG)"},{"key":"893_CR48","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.compmedimag.2014.11.003","volume":"40","author":"J Wang","year":"2015","unstructured":"Wang J, Suenaga H, Liao H et al (2015) Real-time computer-generated integral imaging and 3D image calibration for augmented reality surgical navigation. Comput Med Imaging Gr 40:147\u2013159","journal-title":"Comput Med Imaging Gr"},{"issue":"10","key":"893_CR49","doi-asserted-by":"publisher","first-page":"965","DOI":"10.1109\/34.159901","volume":"14","author":"J Weng","year":"1992","unstructured":"Weng J, Cohen P, Herniou M et al (1992) Camera calibration with distortion models and accuracy evaluation. IEEE Trans Pattern Anal Mach Intell 14(10):965\u2013980","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"893_CR50","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.cap.2022.10.007","volume":"45","author":"Z Xiong","year":"2023","unstructured":"Xiong Z, Wen Z, Cui Z et al (2023) The influences of lateral leakage on hysteresis effects in flexible organic light-emitting diodes array. Curr Appl Phys 45:6\u201311","journal-title":"Curr Appl Phys"},{"key":"893_CR51","doi-asserted-by":"publisher","first-page":"022010","DOI":"10.1088\/2515-7647\/abf02e","volume":"3","author":"K Yin","year":"2021","unstructured":"Yin K, He Z, Xiong J et al (2021) Virtual reality and augmented reality displays: advances and future perspectives. J Phys Photonics 3:022010","journal-title":"J Phys Photonics"},{"key":"893_CR52","doi-asserted-by":"crossref","unstructured":"Zhao C, Beams R, Johnson M et\u00a0al (2022a) 18-2: Assessment of image quality in augmented reality displays using a computational model of target detectability. In: SID symposium digest of technical papers, Wiley Online Library, pp 194\u2013197","DOI":"10.1002\/sdtp.15451"},{"issue":"1","key":"893_CR53","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-022-24345-9","volume":"12","author":"C Zhao","year":"2022","unstructured":"Zhao C, Kim AS, Beams R et al (2022b) Spatiotemporal image quality of virtual reality head mounted displays. Sci Rep 12(1):1\u201313","journal-title":"Sci Rep"},{"issue":"5","key":"893_CR54","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1002\/jsid.1208","volume":"31","author":"C Zhao","year":"2023","unstructured":"Zhao C, Beams R, Badano A (2023) Radially variant contrast measurement in virtual reality headsets using circular concentric ring patterns. J Soc Inf Disp 31(5):387\u2013397","journal-title":"J Soc Inf Disp"}],"container-title":["Virtual Reality"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10055-023-00893-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10055-023-00893-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10055-023-00893-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T21:06:50Z","timestamp":1710364010000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10055-023-00893-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,5]]},"references-count":54,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["893"],"URL":"https:\/\/doi.org\/10.1007\/s10055-023-00893-x","relation":{},"ISSN":["1359-4338","1434-9957"],"issn-type":[{"value":"1359-4338","type":"print"},{"value":"1434-9957","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,5]]},"assertion":[{"value":"28 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors have no conflict of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"11"}}