{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T18:48:51Z","timestamp":1793731731741,"version":"4.6.1"},"reference-count":59,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T00:00:00Z","timestamp":1708905600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T00:00:00Z","timestamp":1708905600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002803","name":"Fondazione Cariplo","doi-asserted-by":"publisher","award":["#2018-0858"],"award-info":[{"award-number":["#2018-0858"]}],"id":[{"id":"10.13039\/501100002803","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Virtual Reality"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The diffusion of virtual reality urges to solve the problem of vergence-accommodation conflict arising when viewing stereoscopic displays, which causes visual stress. We addressed this issue with an approach based on reducing ocular convergence effort. In virtual environments, vergence can be controlled by manipulating the binocular separation of the virtual cameras. Using this technique, we implemented two quasi-3D conditions characterized by binocular image separations intermediate between 3D (stereoscopic) and 2D (monoscopic). In a first experiment, focused on perceptual aspects, ten participants performed a visuo-manual pursuit task while wearing a head-mounted display (HMD) in head-constrained (non-immersive) condition for an overall exposure time of ~\u20097\u00a0min. Passing from 3D to quasi-3D and 2D conditions, progressively resulted in a decrease of vergence eye movements\u2014both mean convergence angle (static vergence) and vergence excursion (dynamic vergence)\u2014and an increase of hand pursuit spatial error, with the target perceived further from the observer and larger. Decreased static and dynamic vergence predicted decreases in asthenopia trial-wise. In a second experiment, focused on tolerance aspects, fourteen participants performed a detection task in near-vision while wearing an HMD in head-free (immersive) condition for an overall exposure time of ~\u200920\u00a0min. Passing from 3D to quasi-3D and 2D conditions, there was a general decrease of both subjective and objective visual stress indicators (ocular convergence discomfort ratings, cyber-sickness symptoms and skin conductance level). Decreased static and dynamic vergence predicted the decrease in these indicators. Remarkably, skin conductance level predicted all subjective symptoms, both trial-wise and session-wise, suggesting that it could become an objective replacement of visual stress self-reports. We conclude that relieving convergence effort by reducing binocular image separation in virtual environments can be a simple and effective way to decrease visual stress caused by stereoscopic HMDs. The negative side-effect\u2014worsening of spatial vision\u2014arguably would become unnoticed or compensated over time. This initial proof-of-concept study should be extended by future large-scale studies testing additional environments, tasks, displays, users, and exposure times.<\/jats:p>","DOI":"10.1007\/s10055-023-00923-8","type":"journal-article","created":{"date-parts":[[2024,2,26]],"date-time":"2024-02-26T10:02:44Z","timestamp":1708941764000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Quasi-3D: reducing convergence effort improves visual comfort of head-mounted stereoscopic displays"],"prefix":"10.1007","volume":"28","author":[{"given":"Vittorio","family":"Dalmasso","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michela","family":"Moretti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7322-2240","authenticated-orcid":false,"given":"Claudio","family":"de\u2019Sperati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,26]]},"reference":[{"key":"923_CR1","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0304-3940(03)00098-3","volume":"340","author":"H Akiduki","year":"2003","unstructured":"Akiduki H, Nishiike S, Watanabe H, Matsuoka K, Kubo T, Takeda N (2003) Visual-vestibular conflict induced by virtual reality in humans. Neurosci Lett 340:197\u2013200","journal-title":"Neurosci Lett"},{"key":"923_CR2","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.jbi.2015.11.007","volume":"59","author":"A Alberdi","year":"2016","unstructured":"Alberdi A, Aztiria A, Basarab A (2016) Towards an automatic early stress recognition system for office environments based on multimodal measurements: a review. J Biomed Inform 59:49\u201375","journal-title":"J Biomed Inform"},{"key":"923_CR3","first-page":"419","volume":"9","author":"TL Alvarez","year":"2015","unstructured":"Alvarez TL (2015) A pilot study of disparity vergence and near dissociated phoria in convergence insufficiency patients before vs. after vergence therapy. Front Human Neurosci 9:419","journal-title":"Front Human Neurosci"},{"key":"923_CR4","doi-asserted-by":"crossref","first-page":"E985","DOI":"10.1097\/OPX.0b013e3181fef1aa","volume":"87","author":"TL Alvarez","year":"2010","unstructured":"Alvarez TL, Vicci VR, Alkan Y, Kim EH, Gohel S, Barrett AM, Chiaravalloti N, Biswal BB (2010) Vision therapy in adults with convergence insufficiency: clinical and functional magnetic resonance imaging measures. Optom vis Sci 87:E985-1002","journal-title":"Optom vis Sci"},{"key":"923_CR5","doi-asserted-by":"crossref","first-page":"45469","DOI":"10.1038\/srep45469","volume":"7","author":"JM Anglin","year":"2017","unstructured":"Anglin JM, Sugiyama T, Liew SL (2017) Visuomotor adaptation in head-mounted virtual reality versus conventional training. Sci Rep 7:45469","journal-title":"Sci Rep"},{"key":"923_CR6","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1146\/annurev-vision-082114-035800","volume":"2","author":"MS Banks","year":"2016","unstructured":"Banks MS, Hoffman DM, Kim J, Wetzstein G (2016) 3D Displays. Annu Rev vis Sci 2:397\u2013435","journal-title":"Annu Rev vis Sci"},{"key":"923_CR7","doi-asserted-by":"crossref","unstructured":"Bimberg P, Weissker T, Kulik A (2020) On the usage of the simulator sickness questionnaire for virtual reality research. In: IEEE conference on virtual reality and 3D user interfaces (VRW). IEEE, City, pp 464\u2013467","DOI":"10.1109\/VRW50115.2020.00098"},{"key":"923_CR8","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1111\/j.1469-8986.2012.01384.x","volume":"49","author":"W Boucsein","year":"2012","unstructured":"Boucsein W, Fowles DC, Grimnes S, Ben-Shakhar G, roth WT, Dawson ME, Filion DL (2012) Publication recommendations for electrodermal measurements. Psychophysiology 49:1017\u20131034","journal-title":"Psychophysiology"},{"key":"923_CR9","volume-title":"Handbook of psychophysiology","author":"JT Cacioppo","year":"2000","unstructured":"Cacioppo JT, Tassinary LG, Berntson GG (2000) Handbook of psychophysiology. Cambridge University Press, Cambridge"},{"key":"923_CR10","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1007\/s10055-021-00592-5","volume":"26","author":"S Chen","year":"2022","unstructured":"Chen S, Weng D (2022) The temporal pattern of VR sickness during 7.5-h virtual immersion. Virtual Reality 26:817\u2013822","journal-title":"Virtual Reality"},{"key":"923_CR11","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1111\/cxo.12798","volume":"102","author":"C Coles-Brennan","year":"2019","unstructured":"Coles-Brennan C, Sulley A, Young G (2019) Management of digital eye strain. Clin Exp Optom 102:18\u201329","journal-title":"Clin Exp Optom"},{"key":"923_CR12","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1016\/j.optm.2010.10.013","volume":"82","author":"JD Collier","year":"2011","unstructured":"Collier JD, Rosenfield M (2011) Accommodation and convergence during sustained computer work. Optometry 82:434\u2013440","journal-title":"Optometry"},{"key":"923_CR13","doi-asserted-by":"crossref","first-page":"205","DOI":"10.3389\/fpsyg.2011.00205","volume":"2","author":"E Combe","year":"2011","unstructured":"Combe E, Fujii N (2011) Depth perception and defensive system activation in a 3-d environment. Front Psychol 2:205","journal-title":"Front Psychol"},{"key":"923_CR14","volume-title":"Optometric clinical practice guideline care of the patient with accommodative and vergence dysfunction","author":"JS Cooper","year":"2011","unstructured":"Cooper JS, Burns CR, Cotter SA, Daum KM, Griffin JR, Scheiman MM (2011) Optometric clinical practice guideline care of the patient with accommodative and vergence dysfunction. American Optometric Association, Washington"},{"key":"923_CR15","doi-asserted-by":"crossref","first-page":"2132","DOI":"10.3389\/fpsyg.2018.02132","volume":"9","author":"N Du\u017cma\u0144ska","year":"2018","unstructured":"Du\u017cma\u0144ska N, Strojny P, Strojny A (2018) Can simulator sickness be avoided? A review on temporal aspects of simulator sickness. Front Psychol 9:2132","journal-title":"Front Psychol"},{"key":"923_CR16","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.ijpsycho.2021.08.001","volume":"168","author":"LV Eberhardt","year":"2021","unstructured":"Eberhardt LV, Gron G, Ulrich M, Huckauf A, Strauch C (2021) Direct voluntary control of pupil constriction and dilation: Exploratory evidence from pupillometry, optometry, skin conductance, perception, and functional MRI. Int J Psychophysiol 168:33\u201342","journal-title":"Int J Psychophysiol"},{"key":"923_CR17","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1163\/22134808-20181293","volume":"31","author":"M Gallagher","year":"2018","unstructured":"Gallagher M, Ferre ER (2018) Cybersickness: a multisensory integration perspective. Multisens Res 31:645\u2013674","journal-title":"Multisens Res"},{"key":"923_CR18","doi-asserted-by":"crossref","first-page":"e0205032","DOI":"10.1371\/journal.pone.0205032","volume":"13","author":"Z Gao","year":"2018","unstructured":"Gao Z, Hwang A, Zhai G, Peli E (2018) Correcting geometric distortions in stereoscopic 3D imaging. PLoS ONE 13:e0205032","journal-title":"PLoS ONE"},{"key":"923_CR19","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1163\/156856808784532509","volume":"21","author":"RL Gregory","year":"2008","unstructured":"Gregory RL (2008) Emmert\u2019s Law and the moon illusion. Spat vis 21:407\u2013420","journal-title":"Spat vis"},{"issue":"33","key":"923_CR20","first-page":"31","volume":"8","author":"DM Hoffman","year":"2008","unstructured":"Hoffman DM, Girshick AR, Akeley K, Banks MS (2008) Vergence-accommodation conflicts hinder visual performance and cause visual fatigue. J vis 8(33):31\u201330","journal-title":"J vis"},{"key":"923_CR21","doi-asserted-by":"crossref","unstructured":"Jones G, Lee D, Holliman N, Ezra D (2001) Controlling perceived depth in stereoscopic images. In: Woods AJ, Bolas MT, Merritt JO, Benton SA (eds) Proceedings of the stereoscopic displays and virtual reality systems VIII, SPIE, vol 4297, City","DOI":"10.1117\/12.430855"},{"key":"923_CR22","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1207\/s15327108ijap0303_3","volume":"3","author":"RS Kennedy","year":"1993","unstructured":"Kennedy RS, Lane NE, Berbaum KS, Lilienthal MG (1993) Simulator sickness questionnaire: an enhanced method for quantifying simulator sickness. Int J Aviat Psychol 3:203\u2013220","journal-title":"Int J Aviat Psychol"},{"key":"923_CR23","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1162\/105474600566952","volume":"9","author":"RS Kennedy","year":"2000","unstructured":"Kennedy RS, Stanney KM, Dunlap WP (2000) Duration and exposure to virtual environments: sickness curves during and across sessions. Presence Teleoper Virtual Environ 9:10","journal-title":"Presence Teleoper Virtual Environ"},{"key":"923_CR24","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s00221-011-2727-7","volume":"212","author":"EH Kim","year":"2011","unstructured":"Kim EH, Vicci VR, Granger-Donetti B, Alvarez TL (2011) Short-term adaptations of the dynamic disparity vergence and phoria systems. Exp Brain Res 212:267\u2013278","journal-title":"Exp Brain Res"},{"key":"923_CR25","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.apergo.2017.12.016","volume":"69","author":"HK Kim","year":"2018","unstructured":"Kim HK, Park J, Choi Y, Choe M (2018) Virtual reality sickness questionnaire (VRSQ): motion sickness measurement index in a virtual reality environment. Appl Ergon 69:66\u201373","journal-title":"Appl Ergon"},{"key":"923_CR26","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.displa.2004.07.004","volume":"25","author":"FL Kooi","year":"2004","unstructured":"Kooi FL, Toet A (2004) Visual comfort of binocular and 3D displays. Displays 25:99\u2013108","journal-title":"Displays"},{"key":"923_CR27","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3072959.3073622","volume":"36","author":"GA Koulieris","year":"2017","unstructured":"Koulieris GA, Bui B, Banks MS, Drettakis G (2017) Accommodation and comfort in head-mounted displays. ACM Trans Graph (TOG) 36:1\u201311","journal-title":"ACM Trans Graph (TOG)"},{"key":"923_CR28","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1109\/TVCG.2015.2473855","volume":"22","author":"G Kramida","year":"2016","unstructured":"Kramida G (2016) Resolving the vergence-accommodation conflict in head-mounted displays. IEEE Trans Visual Comput Graph 22:1912\u20131931","journal-title":"IEEE Trans Visual Comput Graph"},{"key":"923_CR29","doi-asserted-by":"crossref","first-page":"205031212211424","DOI":"10.1177\/20503121221142402","volume":"10","author":"AK Lema","year":"2022","unstructured":"Lema AK, Anbesu EW (2022) Computer vision syndrome and its determinants: a systematic review and meta-analysis. SAGE Open Med 10:20503121221142400","journal-title":"SAGE Open Med"},{"key":"923_CR30","doi-asserted-by":"crossref","first-page":"104401","DOI":"10.1016\/j.neubiorev.2021.10.023","volume":"134","author":"J Limanowski","year":"2022","unstructured":"Limanowski J (2022) Precision control for a flexible body representation. Neurosci Biobehav Rev 134:104401","journal-title":"Neurosci Biobehav Rev"},{"key":"923_CR31","doi-asserted-by":"crossref","first-page":"3176","DOI":"10.3758\/s13414-020-02006-1","volume":"82","author":"P Linton","year":"2020","unstructured":"Linton P (2020) Does vision extract absolute distance from vergence? Atten Percept Psychophys 82:3176\u20133195","journal-title":"Atten Percept Psychophys"},{"key":"923_CR32","doi-asserted-by":"crossref","first-page":"7043","DOI":"10.3390\/jcm11237043","volume":"11","author":"Z Liu","year":"2022","unstructured":"Liu Z, Zhang K, Gao S, Yang J, Qiu W (2022) Correlation between eye movements and asthenopia: a prospective observational study. J Clin Med 11:7043","journal-title":"J Clin Med"},{"key":"923_CR33","doi-asserted-by":"crossref","first-page":"1706","DOI":"10.1177\/0956797615597332","volume":"26","author":"A L\u00f6w","year":"2015","unstructured":"L\u00f6w A, Weymar M, Hamm AO (2015) When threat is near, get out of here: dynamics of defensive behavior during freezing and active avoidance. Psychol Sci 26:1706\u20131716","journal-title":"Psychol Sci"},{"key":"923_CR34","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1167\/jov.21.8.21","volume":"21","author":"J Lyu","year":"2021","unstructured":"Lyu J, Ng CJ, Bang SP, Yoon G (2021) Binocular accommodative response with extended depth of focus under controlled convergences. J vis 21:21","journal-title":"J vis"},{"key":"923_CR35","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1093\/brain\/119.4.1199","volume":"119","author":"TA Martin","year":"1996","unstructured":"Martin TA, Keating JG, Goodkin HP, Bastian AJ, Thach WT (1996) Throwing while looking through prisms: II. Specificity and storage of multiple gaze\u2014throw calibrations. Brain 119:1199\u20131211","journal-title":"Brain"},{"key":"923_CR36","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1007\/s00221-007-1041-x","volume":"183","author":"DR Melmoth","year":"2007","unstructured":"Melmoth DR, Storoni M, Todd G, Finlay AL, Grant S (2007) Dissociation between vergence and binocular disparity cues in the control of prehension. Exp Brain Res 183:283\u2013298","journal-title":"Exp Brain Res"},{"key":"923_CR37","doi-asserted-by":"crossref","unstructured":"Mendiburu B (2009\/2012) 3D movie making: stereoscopic digital cinema from script to screen. Routledge, London.","DOI":"10.4324\/9780080877969"},{"key":"923_CR38","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1007\/s002210050885","volume":"128","author":"M Mon-Williams","year":"1999","unstructured":"Mon-Williams M, Dijkerman HC (1999) The use of vergence information in the programming of prehension. Exp Brain Res 128:578\u2013582","journal-title":"Exp Brain Res"},{"key":"923_CR39","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1007\/s00420-018-1324-5","volume":"91","author":"R Mork","year":"2018","unstructured":"Mork R, Falkenberg HK, Fostervold KI, Thorud HMS (2018) Visual and psychological stress during computer work in healthy, young females-physiological responses. Int Arch Occup Environ Health 91:811\u2013830","journal-title":"Int Arch Occup Environ Health"},{"key":"923_CR40","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s00420-019-01457-w","volume":"93","author":"R Mork","year":"2020","unstructured":"Mork R, Falkenberg HK, Fostervold KI, Thorud HS (2020) Discomfort glare and psychological stress during computer work: subjective responses and associations between neck pain and trapezius muscle blood flow. Int Arch Occup Environ Health 93:29\u201342","journal-title":"Int Arch Occup Environ Health"},{"key":"923_CR41","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1162\/PRES_a_00048","volume":"20","author":"A Naceri","year":"2011","unstructured":"Naceri A, Chellali R, Hoinville T (2011) Depth perception within peripersonal space using head-mounted display. Presence Teleoper Virtual Environ 20:254\u2013272","journal-title":"Presence Teleoper Virtual Environ"},{"key":"923_CR42","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1097\/OPX.0b013e3180dc99a8","volume":"84","author":"NK Nahar","year":"2007","unstructured":"Nahar NK, Sheedy JE, Hayes J, Tai YC (2007) Objective measurements of lower-level visual stress. Optom vis Sci 84:620\u2013629","journal-title":"Optom vis Sci"},{"key":"923_CR43","doi-asserted-by":"crossref","unstructured":"Naqvi SAA, Badruddin N, Malik AS, Hazabbah W, Abdullah B (2013) Does 3D produce more symptoms of visually induced motion sickness? In: 2013 35th annual international conference of the IEEE engineering in medicine and biology society (EMBC), City, pp 6405\u20136408","DOI":"10.1109\/EMBC.2013.6611020"},{"key":"923_CR44","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1111\/j.1475-1313.2010.00763.x","volume":"30","author":"P Neveu","year":"2010","unstructured":"Neveu P, Priot AE, Plantier J, Roumes C (2010) Short exposure to telestereoscope affects the oculomotor system. Ophthalmic Physiol Opt 30:806\u2013815","journal-title":"Ophthalmic Physiol Opt"},{"key":"923_CR45","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.neures.2019.03.003","volume":"153","author":"C Prablanc","year":"2020","unstructured":"Prablanc C, Panico F, Fleury L, Pisella L, Nijboer T, Kitazawa S, Rossetti Y (2020) Adapting terminology: clarifying prism adaptation vocabulary, concepts, and methods. Neurosci Res 153:8\u201321","journal-title":"Neurosci Res"},{"key":"923_CR46","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1007\/s00221-010-2188-4","volume":"202","author":"A-E Priot","year":"2010","unstructured":"Priot A-E, Laboissi\u00e8re R, Sillan O, Roumes C, Prablanc C (2010) Adaptation of egocentric distance perception under telestereoscopic viewing within reaching space. Exp Brain Res 202:825\u2013836","journal-title":"Exp Brain Res"},{"key":"923_CR47","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.neuropsychologia.2010.11.028","volume":"49","author":"AE Priot","year":"2011","unstructured":"Priot AE, Laboissiere R, Plantier J, Prablanc C, Roumes C (2011) Partitioning the components of visuomotor adaptation to prism-altered distance. Neuropsychologia 49:498\u2013506","journal-title":"Neuropsychologia"},{"key":"923_CR48","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s10055-016-0285-9","volume":"20","author":"L Rebenitsch","year":"2016","unstructured":"Rebenitsch L, Owen C (2016) Review on cybersickness in applications and visual displays. Virtual Reality 20:101\u2013125","journal-title":"Virtual Reality"},{"key":"923_CR49","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.heares.2009.04.009","volume":"258","author":"GH Recanzone","year":"2009","unstructured":"Recanzone GH (2009) Interactions of auditory and visual stimuli in space and time. Hear Res 258:89\u201399","journal-title":"Hear Res"},{"key":"923_CR50","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/0141-9382(94)90073-6","volume":"15","author":"S Rushton","year":"1994","unstructured":"Rushton S, Mon-Williams M, Wann J (1994) Binocular vision in a bi-ocular world: New-generation head-mounted displays avoid causing visual deficit. Displays 15:255\u2013260","journal-title":"Displays"},{"key":"923_CR51","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1097\/00006324-200303000-00011","volume":"80","author":"M Scheiman","year":"2003","unstructured":"Scheiman M, Gallaway M, Frantz KA, Peters RJ, Hatch S, Cuff M, Mitchell GL (2003) Nearpoint of convergence: test procedure, target selection, and normative data. Optom vis Sci 80:214\u2013225","journal-title":"Optom vis Sci"},{"key":"923_CR52","first-page":"78630P78631","volume":"7863","author":"T Shibata","year":"2011","unstructured":"Shibata T, Kim J, Hoffman DM, Banks MS (2011) Visual discomfort with stereo displays: effects of viewing distance and direction of vergence-accommodation conflict. Proc SPIE Int Soc Opt Eng 7863:78630P78631-78630P78639","journal-title":"Proc SPIE Int Soc Opt Eng"},{"key":"923_CR53","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1007\/s12243-013-0394-3","volume":"68","author":"M Urvoy","year":"2013","unstructured":"Urvoy M, Barkowsky M, Le Callet P (2013) How visual fatigue and discomfort impact 3D-TV quality of experience: a comprehensive review of technological, psychophysical, and psychological factors. Ann Telecommun Annales Des T\u00e9l\u00e9communications 68:641\u2013655","journal-title":"Ann Telecommun Annales Des T\u00e9l\u00e9communications"},{"key":"923_CR54","doi-asserted-by":"crossref","unstructured":"Verdelet G, Desoche C, Volland F, Farn\u00e8 A, Coudert A, Hermann R, Salemme R (2019) Assessing spatial and temporal reliability of the vive System as a tool for naturalistic behavioural research. In: International conference on 3D immersion (IC3D), City, pp 1\u20138","DOI":"10.1109\/IC3D48390.2019.8975994"},{"key":"923_CR55","doi-asserted-by":"crossref","first-page":"2731","DOI":"10.1016\/0042-6989(95)00018-U","volume":"35","author":"JP Wann","year":"1995","unstructured":"Wann JP, Rushton S, Mon-Williams M (1995) Natural problems for stereoscopic depth perception in virtual environments. Vis Res 35:2731\u20132736","journal-title":"Vis Res"},{"key":"923_CR56","doi-asserted-by":"crossref","first-page":"195","DOI":"10.3758\/BF03211756","volume":"54","author":"RB Welch","year":"1993","unstructured":"Welch RB, Bridgeman B, Anand S, Browman KE (1993) Alternating prism exposure causes dual adaptation and generalization to a novel displacement. Percept Psychophys 54:195\u2013204","journal-title":"Percept Psychophys"},{"key":"923_CR57","doi-asserted-by":"crossref","unstructured":"Zangemeister WH, Heesen C, Rohr D, Gold SM (2020) Oculomotor fatigue and neuropsychological assessments mirror multiple sclerosis fatigue. J Eye Move Res 13","DOI":"10.16910\/jemr.13.4.6"},{"key":"923_CR58","doi-asserted-by":"crossref","first-page":"686740","DOI":"10.3389\/fnins.2021.686740","volume":"15","author":"F Zheng","year":"2021","unstructured":"Zheng F, Hou F, Chen R, Mei J, Huang P, Chen B, Wang Y (2021) Investigation of the relationship between subjective symptoms of visual fatigue and visual functions. Front Neurosci 15:686740","journal-title":"Front Neurosci"},{"key":"923_CR59","doi-asserted-by":"crossref","first-page":"100160","DOI":"10.1016\/j.rio.2021.100160","volume":"5","author":"Y Zhou","year":"2021","unstructured":"Zhou Y, Zhang J, Fang F (2021) Vergence-accommodation conflict in optical see-through display: review and prospect. Results Opt 5:100160","journal-title":"Results Opt"}],"container-title":["Virtual Reality"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10055-023-00923-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10055-023-00923-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10055-023-00923-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,12]],"date-time":"2024-11-12T21:08:32Z","timestamp":1731445712000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10055-023-00923-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,26]]},"references-count":59,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["923"],"URL":"https:\/\/doi.org\/10.1007\/s10055-023-00923-8","relation":{},"ISSN":["1359-4338","1434-9957"],"issn-type":[{"value":"1359-4338","type":"print"},{"value":"1434-9957","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,26]]},"assertion":[{"value":"8 February 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that the research was conducted in the absence of any conflict of interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}],"article-number":"49"}}