{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T23:39:05Z","timestamp":1768001945533,"version":"3.49.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2007,3,1]],"date-time":"2007-03-01T00:00:00Z","timestamp":1172707200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2008,6]]},"DOI":"10.1007\/s10278-007-9022-y","type":"journal-article","created":{"date-parts":[[2007,2,28]],"date-time":"2007-02-28T14:16:20Z","timestamp":1172672180000},"page":"193-207","source":"Crossref","is-referenced-by-count":46,"title":["Introduction to Grayscale Calibration and Related Aspects of Medical Imaging Grade Liquid Crystal Displays"],"prefix":"10.1007","volume":"21","author":[{"given":"Kenneth A.","family":"Fetterly","sequence":"first","affiliation":[]},{"given":"Hartwig R.","family":"Blume","sequence":"additional","affiliation":[]},{"given":"Michael J.","family":"Flynn","sequence":"additional","affiliation":[]},{"given":"Ehsan","family":"Samei","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2007,3,1]]},"reference":[{"key":"9022_CR1","first-page":"97","volume":"1232","author":"H Blume","year":"1990","unstructured":"Blume H, Roehrig H, Browne M, Lan Ji T: Comparison of the physical performance of high resolution CRT displays and films recorded by laser image printers and displayed on light-boxes and the need for a display standard. Medical Imaging IV: Image Capture and Display. SPIE 1232:97\u2013114, 1990","journal-title":"SPIE"},{"key":"9022_CR2","first-page":"344","volume":"2707","author":"H Blume","year":"1996","unstructured":"Blume H: The ACR\/NEMA proposal for a grey-scale display function standard. Image Display. SPIE 2707:344\u2013360, 1996","journal-title":"SPIE"},{"key":"9022_CR3","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1148\/radiographics.19.6.g99no081653","volume":"19","author":"MJ Flynn","year":"1999","unstructured":"Flynn MJ, Kanicki J, Badano A, Meyer WR: High-fidelity electronic display of digital radiographs. RadioGraphics 19:1653\u20131669, 1999","journal-title":"RadioGraphics"},{"key":"9022_CR4","doi-asserted-by":"crossref","unstructured":"Samei E, Badano A, Chakraborty D, Compton K, Cornelius C, Corrigan K, Flynn MJ, Hemminger B, Hangiandreou N, Johnson J, Moxley M, Pavlicek W, Roehrig H, Rutz L, Shepard J, Uzenoff R, Wang J, Willis C. Assessment of Display Performance for Medical Imaging Systems, Report of the American Association of Physicists in Medicine (AAPM) Task Group 18. Madison, WI: Medical Physics Publishing, AAPM On-Line Report No. 03, April 2005","DOI":"10.1118\/1.1861159"},{"key":"9022_CR5","doi-asserted-by":"crossref","DOI":"10.1117\/3.353254","volume-title":"Contrast sensitivity of the human eye and its effects on image quality","author":"PGJ Barten","year":"1999","unstructured":"Barten PGJ: Contrast sensitivity of the human eye and its effects on image quality. Bellingham, WA: SPIE Press, 1999"},{"key":"9022_CR6","unstructured":"Digital Imaging and Communications in Medicine, Part 14: Grayscale Standard Display Function, published by National Electrical Manufacturer\u2019s Association, 2001"},{"key":"9022_CR7","first-page":"181","volume":"5199","author":"H Roehrig","year":"2003","unstructured":"Roehrig H, Chawla A, Krupinski E, Fan J, Gandhi K: Why should you calibrate your display? Penetrating Radiation Systems and Applications V. SPIE 5199:181\u2013192, 2003","journal-title":"SPIE"},{"key":"9022_CR8","first-page":"324","volume":"3663","author":"E Ogawa","year":"1999","unstructured":"Ogawa E, Shimura K: Appearance matching of radiographic images using lightness index. Image Perception and Performance. SPIE 3663:324\u2013332, 1999","journal-title":"SPIE"},{"key":"9022_CR9","first-page":"28","volume":"4323","author":"H Blume","year":"2001","unstructured":"Blume H, Ho AM, Stevens F, Steven PM: Practical aspects of grayscale calibration of display systems. PACS and Integrated Medical Information Systems: Design and Evaluation. SPIE 4323:28\u201341, 2001","journal-title":"SPIE"},{"key":"9022_CR10","first-page":"351","volume":"1666","author":"CW Tyler","year":"1992","unstructured":"Tyler CW, Chan H, Liu L, McBride B, Kontsevich L: How to get 1786 or more grey levels from an 8-bit color monitor. Human Vision, Visual Processing, and Digital Display III. SPIE 1666:351\u2013364, 1992","journal-title":"SPIE"},{"key":"9022_CR11","first-page":"438","volume":"5029","author":"M Flynn","year":"2003","unstructured":"Flynn M, Tchou P: Accurate measurement of monochrome luminance palettes for the calibration of medical LCD monitors. Visualization, Image-Guided Procedures, and Display. SPIE 5029:438\u2013448, 2003","journal-title":"SPIE"},{"key":"9022_CR12","unstructured":"Courtesy of F. Stevens, Planar Systems, Inc., Waltham, MA, 2006"},{"key":"9022_CR13","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1085\/jgp.11.3.255","volume":"11","author":"S Hecht","year":"1928","unstructured":"Hecht S, Hsia Y: Relation between visual acuity and illumination. J Gen Physiol 11:255\u2013281, 1928","journal-title":"J Gen Physiol"},{"key":"9022_CR14","first-page":"271","volume":"4681","author":"H Blume","year":"2002","unstructured":"Blume H, Steven PM, Cobb M, Ho AM, Stevens F, Muller S, Roehrig H, Fans J: Characterization of high-resolution liquid-crystal displays for medical images. Visualization, Image-Guided Procedures, and Display. SPIE 4681:271\u2013292, 2002","journal-title":"SPIE"},{"key":"9022_CR15","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s10278-005-8149-y","volume":"19","author":"S Langer","year":"2006","unstructured":"Langer S, Fetterly K, Mandrekar J, Harmsen S, Bartholmai B, Patton C, Bishop A, McCannel C: ROC Study of four LCD displays under typical medical center lighting conditions. J Digit Imaging 19:30\u201340, 2006","journal-title":"J Digit Imaging"},{"issue":"2","key":"9022_CR16","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1118\/1.2150777","volume":"33","author":"RS Saunders","year":"2006","unstructured":"Saunders RS, Samei E: Resolution and noise measurements of selected commercial medical displays. Med Phys 33(2):308\u2013319, 2006","journal-title":"Med Phys"},{"key":"9022_CR17","first-page":"449","volume":"5029","author":"H Blume","year":"2003","unstructured":"Blume H, Steven PM, Ho AM, Stevens F, Abileah A, Robinson S, Roehrig H, Fan J, Chawla A, Ghandi K: Characterization of liquid-crystal displays for medical images\u2014Part 2. Visualization, Image-Guided Procedures, and Display. SPIE 5029:449\u2013473, 2003","journal-title":"SPIE"},{"key":"9022_CR18","doi-asserted-by":"crossref","first-page":"2602","DOI":"10.1118\/1.1606449","volume":"30","author":"A Badano","year":"2003","unstructured":"Badano A, Flynn M, Martin S, Kanicki J: Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays. Med Phys 30:260\u201322613, 2003","journal-title":"Med Phys"},{"key":"9022_CR19","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1118\/1.2168430","volume":"33","author":"E Samei","year":"2006","unstructured":"Samei E, Wright SL: Viewing angle performance of medical liquid crystal displays. Med Phys 33:645\u2013654, 2006","journal-title":"Med Phys"},{"key":"9022_CR20","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1889\/1.2372420","volume":"14","author":"K Fetterly","year":"2006","unstructured":"Fetterly K, Samei E: A photographic technique for assessing the viewing-angle performance of liquid-crystal displays. J Soc Inf Disp 14:867\u2013872, 2006","journal-title":"J Soc Inf Disp"},{"key":"9022_CR21","doi-asserted-by":"crossref","first-page":"3452","DOI":"10.1118\/1.1824198","volume":"31","author":"A Badano","year":"2004","unstructured":"Badano A, Fifadara DH: Goniometric and conoscopic measurements of angular display contrast for one-, three-, five-, and nine-million-pixel medical liquid crystal displays. Med Phys 31:3452\u20133460, 2004","journal-title":"Med Phys"},{"key":"9022_CR22","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/0042-6989(65)90089-1","volume":"5","author":"AJ Fisher","year":"1965","unstructured":"Fisher AJ, Christie AW: A note on disability glare. Vision Res 5:565\u2013571, 1965","journal-title":"Vision Res"},{"key":"9022_CR23","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/0042-6989(68)90007-2","volume":"8","author":"VM Reading","year":"1968","unstructured":"Reading VM: Disability glare and age. Vision Res 8:207\u2013214, 1968","journal-title":"Vision Res"},{"key":"9022_CR24","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1111\/j.1444-0938.2003.tb03080.x","volume":"86","author":"JJ Vos","year":"2003","unstructured":"Vos JJ: On the cause of disability glare and its dependence on glare angle, age and ocular pigmentation. Clin Exp Optom 86:363\u2013370, 2003","journal-title":"Clin Exp Optom"},{"key":"9022_CR25","first-page":"260","volume":"6146","author":"M McEntee","year":"2006","unstructured":"McEntee M, Brennan P, Evanoff M, Phillps P, O Connor WT, Manning D: Optimum ambient lighting conditions for the viewing of softcopy radiological images. Image Perception, Observer Performance, and Technology Assessment. SPIE 6146:260\u2013268, 2006","journal-title":"SPIE"},{"key":"9022_CR26","first-page":"251","volume":"5744","author":"J Fan","year":"2005","unstructured":"Fan J, Roehrig H, Sundareshan MK, Dallas WJ, Krupinski E: Increasing contrast resolution and decreasing spatial noise for liquid crystal displays using digital dithering. Visualization, Display, and Image-Guided Procedures. SPIE 5744:251\u2013262, 2005","journal-title":"SPIE"},{"key":"9022_CR27","doi-asserted-by":"crossref","unstructured":"Siegel E, Krupinski E, Samei E, Flynn MJ, Andriole K, Erickson B, Thomas J, Badano A, Seibert JA, Pisano E: Digital mammography image quality-image display. Journal of American College of Radiology (in press, 2006)","DOI":"10.1016\/j.jacr.2006.03.007"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-007-9022-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-007-9022-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-007-9022-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T12:01:42Z","timestamp":1559131302000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-007-9022-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,3,1]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2008,6]]}},"alternative-id":["9022"],"URL":"https:\/\/doi.org\/10.1007\/s10278-007-9022-y","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,3,1]]}}}