{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T02:33:21Z","timestamp":1783650801634,"version":"3.55.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2008,5,17]],"date-time":"2008-05-17T00:00:00Z","timestamp":1210982400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2009,12]]},"DOI":"10.1007\/s10278-008-9131-2","type":"journal-article","created":{"date-parts":[[2008,5,16]],"date-time":"2008-05-16T15:58:12Z","timestamp":1210953492000},"page":"681-688","source":"Crossref","is-referenced-by-count":18,"title":["Computer Vision Approach for Ultrasound Doppler Angle Estimation"],"prefix":"10.1007","volume":"22","author":[{"given":"Ashraf A.","family":"Saad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thanasis","family":"Loupas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linda G.","family":"Shapiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2008,5,17]]},"reference":[{"key":"9131_CR1","volume-title":"Duplex Scanning in Vascular Disorders","author":"E Strandness","year":"2002","unstructured":"Strandness E: Duplex Scanning in Vascular Disorders, 3rd edition. Philadelphia, USA: Williams and Wilkins, 2002","edition":"3"},{"key":"9131_CR2","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1016\/S0741-5214(99)70211-9","volume":"29","author":"HG Beebe","year":"1999","unstructured":"Beebe HG, Salles-Cunha SX, Scissons RP, et al: Carotid arterial ultrasound scan imaging: A direct approach to stenosis measurement. J Vasc Surg 29:838\u2013844, 1999","journal-title":"J Vasc Surg"},{"key":"9131_CR3","doi-asserted-by":"crossref","first-page":"207","DOI":"10.2214\/ajr.172.1.9888769","volume":"172","author":"G Soulez","year":"1999","unstructured":"Soulez G, Therasse E, Robillard P, et al: The value of internal carotid systolic velocity ratio for assessing carotid artery stenosis with Doppler sonography. AJR Am J Roentgenol 172:207\u2013212, 1999","journal-title":"AJR Am J Roentgenol"},{"key":"9131_CR4","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1148\/radiol.2292030516","volume":"229","author":"EG Grant","year":"2003","unstructured":"Grant EG, Benson CB, Moneta GL, Alexandrov AV, Baker JD, Bluth EI, et al: Carotid artery stenosis: gray-scale and Doppler US diagnosis\u2014Society of Radiologists in Ultrasound Consensus Conference. Radiology 229:340\u2013346, 2003","journal-title":"Radiology"},{"key":"9131_CR5","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1161\/01.STR.30.2.402","volume":"30","author":"C Ranke","year":"1999","unstructured":"Ranke C, Creutzig A, Becker H, Trappe HJ: Standardization of carotid ultrasound: a hemodynamic method to normalize for interindividual and interequipment variability. Stroke 30:402\u20136, 1999","journal-title":"Stroke"},{"key":"9131_CR6","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/S0929-8266(01)00168-9","volume":"15","author":"SC Lewis","year":"2002","unstructured":"Lewis SC, Wardlaw JM: Which Doppler velocity is best for assessing suitability for carotid endarterectomy? Eur J Ultrasound 15:9\u201320, 2002","journal-title":"Eur J Ultrasound"},{"key":"9131_CR7","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.jvs.2003.12.017","volume":"39","author":"MM Corriveau","year":"2004","unstructured":"Corriveau MM, Johnston KW: Interobserver variability of carotid Doppler peak velocity measurements among technologists in an ICAVL-accredited vascular laboratory. J Vasc Surg 39:735\u201341, 2004","journal-title":"J Vasc Surg"},{"key":"9131_CR8","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/S0929-8266(00)00111-7","volume":"12","author":"GE Mead","year":"2000","unstructured":"Mead GE, Lewis SC, Wardlaw JM: Variability in Doppler ultrasound influences referral of patients for carotid surgery. Eur J Ultrasound 12:137\u201343, 2000","journal-title":"Eur J Ultrasound"},{"key":"9131_CR9","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1259\/0007-1285-69-818-172","volume":"69","author":"PR Hoskins","year":"1996","unstructured":"Hoskins PR: Accuracy of maximum velocity estimates made using Doppler ultrasound systems. Br J Radiol 69:172\u20137, 1996","journal-title":"Br J Radiol"},{"key":"9131_CR10","first-page":"206","volume":"14","author":"RJ Daigle","year":"1990","unstructured":"Daigle RJ, Stavros AT, Lee RM: Overestimation of velocity and frequency values by multielement linear array Doppler. J Vasc Technol 14:206\u201313, 1990","journal-title":"J Vasc Technol"},{"key":"9131_CR11","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/S0301-5629(01)00352-0","volume":"27","author":"AH Steinman","year":"2001","unstructured":"Steinman AH, Tavakkoli J, Myers JG, Cobbold RSC, Johnston KW: Sources of error in maximum velocity estimation using linear phased array Doppler systems with steady flow. Ultrasound Med Biol 27:655\u201364, 2001","journal-title":"Ultrasound Med Biol"},{"key":"9131_CR12","first-page":"972.el","volume":"42","author":"E Lui","year":"2005","unstructured":"Lui E, Steinman A, Cobbold R, Johnston K: Human factors as a source of error in peak Doppler velocity measurement. J Vasc Surg 42:972.el\u2013972.el10, 2005","journal-title":"J Vasc Surg"},{"key":"9131_CR13","unstructured":"ICAVL: Available at http:\/\/www.intersocietal.org\/icavl\/news\/articles\/anglecorrection.htm . Accessed 04 February 2008"},{"key":"9131_CR14","unstructured":"Lihong P, Michael J, Larry Y: Method and apparatus for automatic Doppler angle estimation in ultrasound imaging. US patent no. 6,068,598, 2000"},{"key":"9131_CR15","unstructured":"Criton A, Routh H: Automatic flow angle correction by ultrasound vector. US patent no. 6,464,637 B1, 2002"},{"key":"9131_CR16","unstructured":"Philips Healthcare: Available at http:\/\/www.medical.philips.com\/us\/products\/ultrasound\/general\/iu22\/ . Accessed 04 February 2008"},{"key":"9131_CR17","volume-title":"Doppler Ultrasound Physics, Instrumentation, and Signal Processing","author":"D Evans","year":"2000","unstructured":"Evans D, McDicken W: Doppler Ultrasound Physics, Instrumentation, and Signal Processing, 2nd edition. Chichester, England: Wiley, 2000","edition":"2"},{"key":"9131_CR18","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1109\/34.368189","volume":"17","author":"K Siddiqi","year":"1995","unstructured":"Siddiqi K, Kimia B: Parts of visual form: computational aspects. IEEE Trans Pattern Anal Mach Intell 17:239\u2013251, 1995","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"9131_CR19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.patcog.2003.07.008","volume":"37","author":"D Zheng","year":"2004","unstructured":"Zheng D, Lu G: Review of shape representation and description techniques. Pattern Recogn 37:1\u201319, 2004","journal-title":"Pattern Recogn"},{"key":"9131_CR20","doi-asserted-by":"crossref","DOI":"10.1109\/ICPR.2006.1049","volume-title":"Shape: Decomposition Approach for Ultrasound Color Doppler Image Segmentation","author":"A Saad","year":"2006","unstructured":"Saad A, Shapiro L: Shape Decomposition Approach for Ultrasound Color Doppler Image Segmentation, IEEE ICPR: Hong Kong, 2006"},{"key":"9131_CR21","volume-title":"Binary Digital Image Processing, A Discrete Approach","author":"S Marchand-Maillet","year":"2000","unstructured":"Marchand-Maillet S, Sharaiha Y: Binary Digital Image Processing, A Discrete Approach, London, UK: Academic, 2000"},{"key":"9131_CR22","volume-title":"A Transformation for Extracting New Descriptors of Shape, Models for the Perception of Speech and Visual Form","author":"H Blum","year":"1967","unstructured":"Blum H: A Transformation for Extracting New Descriptors of Shape, Models for the Perception of Speech and Visual Form, Cambridge, MA: M.I.T Press, 1967"},{"key":"9131_CR23","doi-asserted-by":"crossref","unstructured":"Montanari U: Continuous skeletons from digitized images. Journal of the ACM 16, 1969","DOI":"10.1145\/321541.321543"},{"key":"9131_CR24","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1109\/2945.942688","volume":"7","author":"I Bitter","year":"2001","unstructured":"Bitter I, Kauffman A: Penalized-distance volumetric skeleton algorithm. IEEE Trans Vis Comput Graph 7:195\u2013206, 2001","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"9131_CR25","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"i","author":"J Bland","year":"1986","unstructured":"Bland J, Altman D: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet i:307\u2013310, 1986","journal-title":"Lancet"},{"key":"9131_CR26","doi-asserted-by":"crossref","unstructured":"Mochtarian F, Mackworth A: A Theory of multiscale, curvature-based shape representation of planar curves. IEEE Trans Pattern Anal Mach Intell 14, 1992","DOI":"10.1109\/34.149591"},{"key":"9131_CR27","doi-asserted-by":"crossref","unstructured":"Wang Y, Lee S, Toraichi K: Multiscale curvature-based shape representation using B-Splines wavelets. IEEE Trans. Image Process 8, 1999","DOI":"10.1109\/83.799886"},{"key":"9131_CR28","doi-asserted-by":"crossref","unstructured":"Lauchard J, Vialard A, Vieilleville F: Analysis and comparative evaluation of discrete tangent estimators. Proceedings of 12th International Conference on Discrete Geometry for Computer Imagery: 240\u2013251, 2005","DOI":"10.1007\/978-3-540-31965-8_23"},{"issue":"Suppl 1","key":"9131_CR29","doi-asserted-by":"crossref","first-page":"S73","DOI":"10.1016\/S0301-5629(97)80595-9","volume":"23","author":"BL Madrazo","year":"1997","unstructured":"Madrazo BL, Guy WL, Bendick PJ, Dmuchowski C, Matasar KW, Ranval T: Duplex diagnostic criteria, a survey of ICAVL accredited laboratories. Ultrasound Med Biol 23(Suppl 1):S73, 1997","journal-title":"Ultrasound Med Biol"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-008-9131-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-008-9131-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-008-9131-2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T08:01:44Z","timestamp":1559116904000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-008-9131-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,5,17]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2009,12]]}},"alternative-id":["9131"],"URL":"https:\/\/doi.org\/10.1007\/s10278-008-9131-2","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,5,17]]}}}