{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T09:43:28Z","timestamp":1762249408917},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2012,6,22]],"date-time":"2012-06-22T00:00:00Z","timestamp":1340323200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2012,12]]},"DOI":"10.1007\/s10278-012-9500-8","type":"journal-article","created":{"date-parts":[[2012,6,21]],"date-time":"2012-06-21T19:50:15Z","timestamp":1340308215000},"page":"764-770","source":"Crossref","is-referenced-by-count":8,"title":["Extreme Compression for Extreme Conditions: Pilot Study to Identify Optimal Compression of CT Images Using MPEG-4 Video Compression"],"prefix":"10.1007","volume":"25","author":[{"given":"P. Gabriel","family":"Peterson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sung K.","family":"Pak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Binh","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Genevieve","family":"Jacobs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Les","family":"Folio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2012,6,22]]},"reference":[{"issue":"2","key":"9500_CR1","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1148\/radiol.2412060169","volume":"241","author":"JM Boone","year":"2006","unstructured":"Boone JM: Multidetector CT: opportunities, challenges, and concerns associated with scanners with 64 or more detector rows. Radiology 241(2):334\u2013337, 2006","journal-title":"Radiology"},{"issue":"2","key":"9500_CR2","doi-asserted-by":"crossref","first-page":"463","DOI":"10.2214\/ajr.163.2.8037051","volume":"163","author":"MA Goldberg","year":"1994","unstructured":"Goldberg MA, Pivovarov M, Mayo-Smith WW, Bhalla MP, \"Blickman JG, Bramson RT, Boland GW, Llewellyn HJ, Halpern E: Application of wavelet compression to digitized radiographs. Am J Roentgenol 163(2):463\u2013468, 1994","journal-title":"Am J Roentgenol"},{"issue":"3","key":"9500_CR3","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1148\/radiology.206.3.9494474","volume":"206","author":"V Savcenko","year":"1998","unstructured":"Savcenko V, Erickson BJ, Palisson PM, Persons KR, Manduca A, Hartman TE, Harms GF, Brown LR: Detection of subtle abnormalities on chest radiographs after irreversible compression. Radiology 206(3):609\u2013616, 1998","journal-title":"Radiology"},{"issue":"2","key":"9500_CR4","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1007\/s10278-002-0009-4","volume":"15","author":"AJ Megibow","year":"2002","unstructured":"Megibow AJ, Rusinek H, Lisi V, Bennett GL, Macari M, Israel GM, Krinsky GA: Computed tomography diagnosis utilizing compressed image data: an ROC analysis using acute appendicitis as a model. J Digit Imaging 15(2):84\u201390, 2002","journal-title":"J Digit Imaging"},{"issue":"1","key":"9500_CR5","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1148\/radiol.2381040896","volume":"238","author":"M Kallergi","year":"2006","unstructured":"Kallergi M, Lucier BJ, Berman CG, Hersh MR, Kim JJ, Szabunio MS, Clark RA: High-performance wavelet compression for mammography: localization response operating characteristic evaluation. Radiology 238(1):62\u201373, 2006","journal-title":"Radiology"},{"issue":"2","key":"9500_CR6","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1007\/s10278-003-1652-0","volume":"16","author":"TJ Chen","year":"2003","unstructured":"Chen TJ, Chuang KS, Wu J, Chen SC, Hwang IM, Jan ML: Quality degradation in lossy wavelet image compression. J Digit Imaging 16(2):210\u2013215, 2003","journal-title":"J Digit Imaging"},{"key":"9500_CR7","unstructured":"Microsoft Healthvault www.healthvault.com . Accessed June 2012."},{"key":"9500_CR8","unstructured":"Microsoft Healthvault; Organize your medical records in one place. http:\/\/www.microsoft.com\/en-us\/healthvault\/organize\/medical-records.aspx . Accessed June 2012."},{"key":"9500_CR9","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4419-5854-9","volume-title":"Combat radiology","author":"LR Folio","year":"2010","unstructured":"Folio LR: Combat radiology. Springer, NY, 2010"},{"key":"9500_CR10","unstructured":"Shogan P, Folio L: \u201cMicrosoft healthvault: An electronic personal health record option for deployed military.\u201d RSNA. LL-IN3510-L. Nov. 2009"},{"issue":"1","key":"9500_CR11","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1148\/radiol.2281020254","volume":"228","author":"JP Ko","year":"2003","unstructured":"Ko JP, Rusinek H, Naidich DP, McGuinness G, Rubinowitz AN, Leitman BS, Martino JM: Wavelet compression of low-dose chest CT data: effect on lung nodule detection. Radiology 228(1):70\u201375, 2003","journal-title":"Radiology"},{"issue":"6","key":"9500_CR12","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1109\/TIP.2006.871160","volume":"15","author":"G Fahmy","year":"2006","unstructured":"Fahmy G, Black Jr, J, Panchanathan S: Texture characterization for joint compression and classification based on human perception in the wavelet domain. IEEE Trans Image Process 15(6):1389\u20131396, 2006","journal-title":"IEEE Trans Image Process"},{"issue":"2 Suppl 1","key":"9500_CR13","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/BF03167656","volume":"13","author":"V Savcenko","year":"2000","unstructured":"Savcenko V, Erickson BJ, Persons KR, Campeau NG, Huston 3rd, J, Wood CP, Schreiner SA: An evaluation of JPEG and JPEG 2000 irreversible compression algorithms applied to neurologic computed tomography and magnetic resonance images. J Digit Imaging 13(2 Suppl 1):183\u2013185, 2000","journal-title":"J Digit Imaging"},{"issue":"3","key":"9500_CR14","first-page":"267","volume":"71","author":"H Ringl","year":"2000","unstructured":"Ringl H, Schernthaner RE, Kulinna-Cosentini C, Weber M, Schaefer-Prokop C, Herold CJ, Schima W: Lossy three-dimensional JPEG2000 compression of abdominal CT images: assessment of the visually lossless threshold and effect of compresnd. Environ Med 71(3):267, 2000","journal-title":"Environ Med"},{"key":"9500_CR15","unstructured":"Folio L, Sneeder W: Applied telemedicine, teleconsultation and tele-education aboard USS George Washington Aircraft Carrier. Abstract. Aviation, Space, and Environmental Medicine, 71:3, March 2000, 267"},{"issue":"4","key":"9500_CR16","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1148\/rg.274065124","volume":"27","author":"CW Arnold","year":"2007","unstructured":"Arnold CW, Bui AA, Morioka C, El-Saden S, Kangarloo H: Informatics in radiology a prototype web-based reporting system for onsite-offsite clinician communication. Radiographics 27(4):1201\u20131211, 2007","journal-title":"Radiographics"},{"issue":"1","key":"9500_CR17","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/S0301-5629(02)00696-8","volume":"29","author":"TL Poepping","year":"2003","unstructured":"Poepping TL, Gill J, Fenster A, Holdsworth DW: MP3 compression of Doppler ultrasound signals. Ultrasound Med Biol 29(1):65\u201376, 2003","journal-title":"Ultrasound Med Biol"},{"issue":"2","key":"9500_CR18","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/S0892-1997(03)00007-9","volume":"17","author":"J Gonzalez","year":"2003","unstructured":"Gonzalez J, Cervera T, Llau MJ: Acoustic analysis of pathological voices compressed with MPEG system. J Voice 17(2):126\u2013139, 2003","journal-title":"J Voice"},{"issue":"3","key":"9500_CR19","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1080\/14015430152728034","volume":"26","author":"J Gonzalez","year":"2001","unstructured":"Gonzalez J, Cervera T: The effect of MPEG audio compression on multidimensional set of voice parameters. Logoped Phoniatr Vocol 26(3):124\u2013138, 2001","journal-title":"Logoped Phoniatr Vocol"},{"key":"9500_CR20","volume-title":"Protecting Those Who Serve; Teleradiology technology delivers quicker diagnoses for deployed troops","author":"D Hinsley","year":"2005","unstructured":"Hinsley D. Protecting Those Who Serve; Teleradiology technology delivers quicker diagnoses for deployed troops. Imaging Economics. August 2005. http:\/\/www.imagingeconomics.com\/issues\/articles\/MI_2005-08_02.asp . Accessed June 2012."}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-012-9500-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-012-9500-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-012-9500-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T08:12:18Z","timestamp":1559117538000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-012-9500-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6,22]]},"references-count":20,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,12]]}},"alternative-id":["9500"],"URL":"https:\/\/doi.org\/10.1007\/s10278-012-9500-8","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,6,22]]}}}