{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T06:21:51Z","timestamp":1761805311734},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2014,5,7]],"date-time":"2014-05-07T00:00:00Z","timestamp":1399420800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2014,10]]},"DOI":"10.1007\/s10278-014-9695-y","type":"journal-article","created":{"date-parts":[[2014,5,6]],"date-time":"2014-05-06T17:34:31Z","timestamp":1399397671000},"page":"679-686","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of Low-Cost Telemammography Screening Configurations: A Comparison with Film-Screen Readings in Vulnerable Areas"],"prefix":"10.1007","volume":"27","author":[{"given":"Antonio J.","family":"Salazar","sequence":"first","affiliation":[]},{"given":"Javier","family":"Romero","sequence":"additional","affiliation":[]},{"given":"Oscar","family":"Bernal","sequence":"additional","affiliation":[]},{"given":"Angela","family":"Moreno","sequence":"additional","affiliation":[]},{"given":"Sof\u00eda","family":"Velasco","sequence":"additional","affiliation":[]},{"given":"Xavier","family":"D\u00edaz","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2014,5,7]]},"reference":[{"key":"9695_CR1","doi-asserted-by":"crossref","first-page":"S16","DOI":"10.1111\/j.1075-122X.2006.00200.x","volume":"12","author":"RA Smith","year":"2006","unstructured":"Smith RA, Caleffi M, Albert U-S, Chen THH, Duffy SW, Franceschi D, Nystr\u00f6m L: Breast Cancer in Limited-Resource Countries: Early Detection and Access to Care. Breast J 12:S16\u2013S26, 2006","journal-title":"Breast J"},{"key":"9695_CR2","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1046\/j.1524-4741.9.s2.4.x","volume":"9","author":"BO Anderson","year":"2003","unstructured":"Anderson BO, Braun S, Lim S, Smith RA, Taplin S, Thomas DB: Early Detection of Breast Cancer in Countries with Limited Resources. Breast J 9:S51\u2013S59, 2003","journal-title":"Breast J"},{"key":"9695_CR3","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1186\/bcr616","volume":"5","author":"R Smith","year":"2003","unstructured":"Smith R: IARC Handbooks of Cancer Prevention, Volume 7: Breast Cancer Screening. Breast Cancer Res 5:216\u2013217, 2003","journal-title":"Breast Cancer Res"},{"key":"9695_CR4","doi-asserted-by":"crossref","first-page":"347","DOI":"10.7326\/0003-4819-137-5_Part_1-200209030-00012","volume":"137","author":"LL Humphrey","year":"2002","unstructured":"Humphrey LL, Helfand M, Chan BKS, Woolf SH: Breast Cancer Screening: A Summary of the Evidence for the U.S. Preventive Services Task Force. Ann Intern Med 137:347\u2013360, 2002","journal-title":"Ann Intern Med"},{"key":"9695_CR5","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1056\/NEJMcp021804","volume":"348","author":"SW Fletcher","year":"2003","unstructured":"Fletcher SW, Elmore JG: Mammographic Screening for Breast Cancer. N Engl J Med 348:1672\u20131680, 2003","journal-title":"N Engl J Med"},{"key":"9695_CR6","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1056\/NEJMoa052911","volume":"353","author":"ED Pisano","year":"2005","unstructured":"Pisano ED, Gatsonis C, Hendrick E, Yaffe M, Baum JK, Acharyya S, Conant EF, Fajardo LL, Bassett L, D'Orsi C, Jong R, Rebner M: Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening. N Engl J Med 353:1773\u20131783, 2005","journal-title":"N Engl J Med"},{"key":"9695_CR7","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1007\/s00330-006-0452-6","volume":"17","author":"T Kamitani","year":"2007","unstructured":"Kamitani T, Yabuuchi H, Soeda H, Matsuo Y, Okafuji T, Sakai S, Furuya A, Hatakenaka M, Ishii N, Honda H: Detection of masses and microcalcifications of breast cancer on digital mammograms: comparison among hard-copy film, 3-megapixel liquid crystal display (LCD) monitors and 5-megapixel LCD monitors: an observer performance study. Eur Radiol 17:1365\u20131371, 2007","journal-title":"Eur Radiol"},{"key":"9695_CR8","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1007\/s10278-003-1661-z","volume":"16","author":"S Obenauer","year":"2003","unstructured":"Obenauer S, Hermann K-P, Marten K, Luftner-Nagel S, Heyden D, Skaane P, Grabbe E: Soft Copy versus Hard Copy Reading in Digital Mammography. J Digit Imaging 16:341\u2013344, 2003","journal-title":"J Digit Imaging"},{"key":"9695_CR9","doi-asserted-by":"crossref","first-page":"889","DOI":"10.2214\/ajr.173.4.10511142","volume":"173","author":"K Powell","year":"1999","unstructured":"Powell K, Obuchowski N, Chilcote W, Barry M, Ganobcik S, Cardenosa G: Film-screen versus digitized mammography: assessment of clinical equivalence. AJR 173:889\u2013894, 1999","journal-title":"AJR"},{"key":"9695_CR10","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1007\/s10278-006-1046-1","volume":"20","author":"J Gitlin","year":"2007","unstructured":"Gitlin J, Narayan A, Mitchell C, Akmal A, Eisner D, Peterson L, Nie D, McClintock T: A Comparative Study of Conventional Mammography Film Interpretations with Soft Copy Readings of the Same Examinations. J Digit Imaging 20:42\u201352, 2007","journal-title":"J Digit Imaging"},{"key":"9695_CR11","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1148\/radiol.2232010704","volume":"223","author":"ED Pisano","year":"2002","unstructured":"Pisano ED, Cole EB, Kistner EO, Muller KE, Hemminger BM, Brown ML, Johnston RE, Kuzmiak CM, Braeuning MP, Freimanis RI, Soo MS, Baker JA, Walsh R: Interpretation of digital mammograms: Comparison of speed and accuracy of soft-copy versus printed-film display. Radiology 223:483\u2013488, 2002","journal-title":"Radiology"},{"key":"9695_CR12","doi-asserted-by":"crossref","first-page":"153","DOI":"10.3348\/kjr.2003.4.3.153","volume":"4","author":"SA Hwang","year":"2003","unstructured":"Hwang SA, Seo JB, Choi BK, Do KH, Ko SM, Lee SH, Lee JS, Song JW, Song KS, Lim TH: Liquid-crystal display monitors and cathode-ray tube monitors: A comparison of observer performance in the detection of small solitary pulmonary nodules. Korean J Radiol 4:153\u2013156, 2003","journal-title":"Korean J Radiol"},{"key":"9695_CR13","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.ejrad.2007.05.023","volume":"66","author":"CM Park","year":"2008","unstructured":"Park CM, Lee HJ, Goo JM, Han DH, Kim JH, Lim KY, Kim SH, Kang JJ, Kim KG, Lee CH, Chun EJ, Im JG: Comparison of observer performance on soft-copy reading of digital chest radiographs: High resolution liquid-crystal display monitors versus cathode-ray tube monitors. Eur J Radiol 66:13\u201318, 2008","journal-title":"Eur J Radiol"},{"key":"9695_CR14","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1007\/s10278-005-8149-y","volume":"19","author":"S Langer","year":"2006","unstructured":"Langer S, Fetterly K, Mandrekar J, Harmsen S, Bartholmai B, Patton C, Bishop A, McCannel C: ROC Study of Four LCD Displays Under Typical Medical Center Lighting Conditions. J Digit Imaging 19:30\u201340, 2006","journal-title":"J Digit Imaging"},{"key":"9695_CR15","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1007\/s10278-007-9028-5","volume":"20","author":"H Geijer","year":"2007","unstructured":"Geijer H, Geijer M, Forsberg L, Kheddache S, Sund P: Comparison of Color LCD and Medical-grade Monochrome LCD Displays in Diagnostic Radiology. J Digit Imaging 20:114\u2013121, 2007","journal-title":"J Digit Imaging"},{"key":"9695_CR16","unstructured":"ACR: American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS Atlas), Reston, Va: ACR, 2003"},{"key":"9695_CR17","doi-asserted-by":"crossref","unstructured":"Salazar AJ, Romero J, Bernal O, Moreno A, Velasco S, D\u00edaz X: Effects of the DICOM grayscale standard display function on the accuracy of medical-grade grayscale and consumer-grade color displays for telemammography screening. Proc. IX International Seminar on Medical Information Processing and Analysis: Mexico, November 19, 8922:89220R-89220R-89210, 2013","DOI":"10.1117\/12.2035999"},{"key":"9695_CR18","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1089\/tmj.2010.0189","volume":"14","author":"AJ Salazar","year":"2011","unstructured":"Salazar AJ, Camacho JC, Aguirre DA: Comparison between different cost devices for digital capture of X-ray films with Computed Tomography (CT) correlation. Telemed J Health 14:275\u2013282, 2011","journal-title":"Telemed J Health"},{"key":"9695_CR19","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1258\/jtt.2011.110708","volume":"18","author":"AJ Salazar","year":"2012","unstructured":"Salazar AJ, Camacho JC, Aguirre DA: Agreement and reading-time assessment of differently priced devices for digital capture of X-ray films. J Telemed Telecare 18:82\u201385, 2012","journal-title":"J Telemed Telecare"},{"key":"9695_CR20","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s10278-011-9391-0","volume":"25","author":"AJ Salazar","year":"2012","unstructured":"Salazar AJ, Camacho JC, Aguirre DA: Comparison between different cost devices for digital capture of X-ray films: an image characteristics detection approach. J Digit Imaging 25:91\u2013100, 2012. doi: 10.1007\/s10278-011-9391-0","journal-title":"J Digit Imaging"},{"key":"9695_CR21","doi-asserted-by":"crossref","unstructured":"Salazar AJ, Camacho JC, Aguirre DA, Ocampo J, Diaz XA: Clinical Diagnostic Accuracy on chest X-ray of the DICOM Grayscale Standard Display Function in Medical-grade Grayscale and Consumer-grade Color Displays. AJR In press, 2014","DOI":"10.2214\/AJR.13.11509"},{"key":"9695_CR22","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1089\/tmj.2013.0236","volume":"20","author":"AJ Salazar","year":"2013","unstructured":"Salazar AJ, Camacho JC, Aguirre DA, Ocampo J, Diaz XA: Diagnostic accuracy of digitized chest X-rays using consumer-grade color displays for low-cost teleradiology services. Telemed J Health 20:304\u2013311, 2013","journal-title":"Telemed J Health"},{"key":"9695_CR23","doi-asserted-by":"crossref","unstructured":"Salazar A, Aguirre D, Ocampo J, Camacho J, D\u00edaz X: Evaluation of Three Pneumothorax Size Quantification Methods on Digitized Chest X-ray Films Using Medical-Grade Grayscale and Consumer-Grade Color Displays. J Digit Imaging 1\u20137, 2013","DOI":"10.1007\/s10278-013-9651-2"},{"key":"9695_CR24","doi-asserted-by":"crossref","first-page":"671","DOI":"10.2214\/ajr.179.3.1790671","volume":"179","author":"JM Lewin","year":"2002","unstructured":"Lewin JM, D'Orsi CJ, Hendrick RE, Moss LJ, Isaacs PK, Karellas A, Cutter GR: Clinical Comparison of Full-Field Digital Mammography and Screen-Film Mammography for Detection of Breast Cancer. AJR 179:671\u2013677, 2002","journal-title":"AJR"},{"key":"9695_CR25","doi-asserted-by":"crossref","first-page":"603","DOI":"10.2214\/ajr.175.3.1750603","volume":"175","author":"NA Obuchowski","year":"2000","unstructured":"Obuchowski NA: Sample Size Tables For Receiver Operating Characteristic Studies. AJR 175:603\u2013608, 2000","journal-title":"AJR"},{"key":"9695_CR26","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1097\/00004424-199209000-00015","volume":"27","author":"DD Dorfman","year":"1992","unstructured":"Dorfman DD, Berbaum KS, Metz CE: Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method. Investig Radiol 27:723\u2013731, 1992","journal-title":"Investig Radiol"},{"key":"9695_CR27","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1016\/S1076-6332(97)80032-3","volume":"4","author":"CA Roe","year":"1997","unstructured":"Roe CA, Metz CE: Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: validation with computer simulation. Acad Radiol 4:298\u2013303, 1997","journal-title":"Acad Radiol"},{"key":"9695_CR28","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2307\/2529310","volume":"33","author":"JR Landis","year":"1977","unstructured":"Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 33:159\u2013174, 1977","journal-title":"Biometrics"},{"key":"9695_CR29","volume-title":"Mammographic Interpretation Training: How Could Low Cost Display Devices Help?","author":"Y Chen","year":"2010","unstructured":"Chen Y, Gale A: Mammographic Interpretation Training: How Could Low Cost Display Devices Help? Springer Berlin, Heidelberg, 2010"},{"key":"9695_CR30","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1016\/j.acra.2005.03.071","volume":"12","author":"EA Krupinski","year":"2005","unstructured":"Krupinski EA: Visual search of mammographic images: Influence of lesion subtlety. Acad Radiol 12:965\u2013969, 2005","journal-title":"Acad Radiol"},{"key":"9695_CR31","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1007\/s10278-006-1052-3","volume":"20","author":"T Kimpe","year":"2007","unstructured":"Kimpe T, Tuytschaever T: Increasing the Number of Gray Shades in Medical Display Systems\u2014How Much is Enough? J Digit Imaging 20:422\u2013432, 2007","journal-title":"J Digit Imaging"},{"key":"9695_CR32","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s10278-007-9022-y","volume":"21","author":"K Fetterly","year":"2008","unstructured":"Fetterly K, Blume H, Flynn M, Samei E: Introduction to Grayscale Calibration and Related Aspects of Medical Imaging Grade Liquid Crystal Displays. J Digit Imaging 21:193\u2013207, 2008","journal-title":"J Digit Imaging"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-014-9695-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-014-9695-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-014-9695-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,10]],"date-time":"2019-08-10T07:27:20Z","timestamp":1565422040000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-014-9695-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,7]]},"references-count":32,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,10]]}},"alternative-id":["9695"],"URL":"https:\/\/doi.org\/10.1007\/s10278-014-9695-y","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,7]]}}}