{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T20:55:37Z","timestamp":1761252937576},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2014,11,11]],"date-time":"2014-11-11T00:00:00Z","timestamp":1415664000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2015,6]]},"DOI":"10.1007\/s10278-014-9736-6","type":"journal-article","created":{"date-parts":[[2014,11,14]],"date-time":"2014-11-14T18:34:13Z","timestamp":1415990053000},"page":"338-345","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of Back Projection Methods for Breast Tomosynthesis Image Reconstruction"],"prefix":"10.1007","volume":"28","author":[{"given":"Weihua","family":"Zhou","sequence":"first","affiliation":[]},{"given":"Jianping","family":"Lu","sequence":"additional","affiliation":[]},{"given":"Otto","family":"Zhou","sequence":"additional","affiliation":[]},{"given":"Ying","family":"Chen","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2014,11,11]]},"reference":[{"key":"9736_CR1","doi-asserted-by":"crossref","DOI":"10.1007\/978-94-011-4613-5","volume-title":"Mammographic Image Analysis","author":"R Highnam","year":"1999","unstructured":"Highnam R, Brady M (1999) Mammographic Image Analysis. Kluwer Academic Publishers, Dordrecht, The Netherlands"},{"key":"9736_CR2","volume-title":"Mammography and Beyond: Developing Technologies for the early Detection of Breast Cancer","author":"SJ Nass","year":"2001","unstructured":"Nass SJ, Henderson IC, Lashof JC (2001) Mammography and Beyond: Developing Technologies for the early Detection of Breast Cancer. National Academy Press, Washington, DC"},{"key":"9736_CR3","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1148\/radiology.205.2.9356620","volume":"205","author":"LT Niklason","year":"1997","unstructured":"Niklason LT, Christian BT, Niklason LE, Kopans DB, Castleberry DE, Opsahl-Ong BH, Landberg CE, Slanetz PJ, Giardino AA, Moore RH, Albagi D, DeJule MC, Fitzgerald PA, Fobare DF, Giambattista BW, Kwasnick RF, Liu J, Lubowski SJ, Possin GE, Richotte JF, Wei CY, Wirth RF (1997) Digital tomosynthesis in breast imaging. Radiology 205:399\u2013406","journal-title":"Radiology"},{"issue":"Suppl 1","key":"9736_CR4","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1148\/rg.27si075511","volume":"27","author":"JM Park","year":"2007","unstructured":"Park JM, Franken EA, Garg M, Fajardo LL, Niklason LT (2007) Breast tomosynthesis: present considerations and future applications. Radiographics 27(Suppl 1):231\u2013240","journal-title":"Radiographics"},{"issue":"10","key":"9736_CR5","doi-asserted-by":"crossref","first-page":"3885","DOI":"10.1118\/1.2776256","volume":"34","author":"Y Chen","year":"2007","unstructured":"Chen Y, Lo JY, Dobbins JT III (2007) Importance of point-by-point back projection (BP) correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of microcalcifications. Med Phys 34(10):3885\u20133892","journal-title":"Med Phys"},{"key":"9736_CR6","first-page":"131","volume":"6142","author":"T Mertelemeier","year":"2006","unstructured":"Mertelemeier T, Orman J, Haerer W, Dudam MK (2006) Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device. Proc SPIE 6142:131\u2013142","journal-title":"Proc SPIE"},{"key":"9736_CR7","unstructured":"Chen Y, Lo JY, Dobbins JT III (2004) Matrix Inversion Tomosynthesis (MITS) of the Breast: Preliminary Results. RSNA 90th Scientific Assembly, Chicago, IL"},{"key":"9736_CR8","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1118\/1.1543934","volume":"30","author":"T Wu","year":"2003","unstructured":"Wu T, Stewart A, Stanton M, McCauley T, Philips W, Kopans DB, Moore RH, Eberhard JW, Opsahl-Ong B, Niklason L, Williams MB (2003) Tomographic mammography using a limited number of low-dose cone-beam projection images. Med Phys 30:365\u2013380","journal-title":"Med Phys"},{"issue":"4","key":"9736_CR9","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1504\/IJFIPM.2008.022152","volume":"1","author":"W Zhou","year":"2008","unstructured":"Zhou W, Balla A, Chen Y (2008) Tomosynthesis Reconstruction Using an Accelerated Expectation Maximization Algorithm with Novel Data Structure Based on Sparse Matrix Ray-Tracing Method. Int J Funct Inform Personalised Med 1(4):355\u2013365","journal-title":"Int J Funct Inform Personalised Med"},{"issue":"1","key":"9736_CR10","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1109\/42.20361","volume":"8","author":"AH Andersen","year":"1989","unstructured":"Andersen AH (1989) Algebraic reconstruction in CT from limited views. IEEE Trans On Med Imaging 8(1):50\u201355","journal-title":"IEEE Trans On Med Imaging"},{"issue":"10","key":"9736_CR11","doi-asserted-by":"crossref","first-page":"3781","DOI":"10.1118\/1.2237543","volume":"33","author":"Y Zhang","year":"2006","unstructured":"Zhang Y, Chan H, Sahiner B, Wei J, Goodsitt MM, Hadjiiski LM, Ge J, Zhou C (2006) A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. Med Phys 33(10):3781\u20133795","journal-title":"Med Phys"},{"key":"9736_CR12","doi-asserted-by":"crossref","first-page":"725859","DOI":"10.1117\/12.811659","volume":"7258","author":"Y Chen","year":"2009","unstructured":"Chen Y, Zhou W, Yang G, Lu JP, Zhou O (2009) Breast tomosynthesis reconstruction with a multi-beam x-ray source. Proc SPIE 7258:725859\u20137258568","journal-title":"Proc SPIE"},{"key":"9736_CR13","first-page":"1","volume":"7622H","author":"W Zhou","year":"2010","unstructured":"Zhou W, Xin Q, Lu JP, Zhou O, Chen Y (2010) Multi-beam X-ray source breast tomosynthesis reconstruction with different algorithms. Proc SPIE 7622H:1\u20138","journal-title":"Proc. SPIE"},{"key":"9736_CR14","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1088\/0031-9155\/48\/19\/R01","volume":"48","author":"JT Dobbins III","year":"2003","unstructured":"Dobbins JT III, Godfrey DJ (2003) Digital X-ray tomosynthesis: current state of the art and clinical potential. Phys Med Biol 48:65\u2013106","journal-title":"Phys Med Biol"},{"key":"9736_CR15","doi-asserted-by":"crossref","first-page":"5219","DOI":"10.1118\/1.2996014","volume":"35","author":"B Zhao","year":"2008","unstructured":"Zhao B, Zhao W (2008) Three-dimensional linear system analysis for breast tomosynthesis. Med Phys 35:5219. doi: 10.1118\/1.2996014","journal-title":"Med Phys"},{"key":"9736_CR16","volume-title":"Digital Image Processing","author":"RC Gonzalez","year":"2002","unstructured":"Gonzalez RC, Woods RE (2002) Digital Image Processing. Second Edition, Prentice Hall"},{"key":"9736_CR17","unstructured":"Smith L: A Tutorial on Principal Components Analysis, www.cs.otago.ac.nz\/cosc453\/student_tutorials\/principal_components.pdf , 2002."},{"key":"9736_CR18","doi-asserted-by":"crossref","first-page":"69131A","DOI":"10.1117\/12.770622","volume":"6913","author":"G Yang","year":"2008","unstructured":"Yang G, Rajaram R, Cao G, Sultana S, Liu Z, Lalush D, Lu JP, Zhou O (2008) Stationary digital breast tomosynthesis system with a multi-beam field emission x-ray source array. Proc SPIE 6913:69131A","journal-title":"Proc SPIE"},{"key":"9736_CR19","unstructured":"CIRS Company. Stereotactic needle biopsy training phantom Model 013. Available at: http:\/\/www.cirsinc.com\/products\/all\/44\/stereotactic-needle-biopsy-training-phantom\/ . Accessed on August 9th, 2014."},{"issue":"2","key":"9736_CR20","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1007\/978-3-642-03879-2_128","volume":"25","author":"LTG Guimar\u00e3es","year":"2009","unstructured":"Guimar\u00e3es LTG, Schiabel H, Stemberg DRM (2009) Computer Simulation in Evaluating the Attenuation Coefficients Influence on Mammography Images Contrast. IFMBE Proc 25(2):454\u2013457","journal-title":"IFMBE Proc"},{"key":"9736_CR21","unstructured":"Chen Y, Zhou W, Dobbins JT (2014) Fourier-Domain Methods for Optimization of Tomosynthesis (NEQ). book chapter in Tomosynthesis Imaging, ed. Reiser I and Glick S: Taylor & Francis"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-014-9736-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-014-9736-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-014-9736-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T12:12:24Z","timestamp":1559131944000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-014-9736-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11,11]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["9736"],"URL":"https:\/\/doi.org\/10.1007\/s10278-014-9736-6","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,11,11]]}}}