{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T01:44:12Z","timestamp":1773279852365,"version":"3.50.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2015,11,30]],"date-time":"2015-11-30T00:00:00Z","timestamp":1448841600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2016,6]]},"DOI":"10.1007\/s10278-015-9849-6","type":"journal-article","created":{"date-parts":[[2015,11,30]],"date-time":"2015-11-30T19:49:05Z","timestamp":1448912945000},"page":"347-356","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos"],"prefix":"10.1007","volume":"29","author":[{"given":"Changsun","family":"Kim","sequence":"first","affiliation":[]},{"given":"Hyunmin","family":"Cha","sequence":"additional","affiliation":[]},{"given":"Bo Seung","family":"Kang","sequence":"additional","affiliation":[]},{"given":"Hyuk Joong","family":"Choi","sequence":"additional","affiliation":[]},{"given":"Tae Ho","family":"Lim","sequence":"additional","affiliation":[]},{"given":"Jaehoon","family":"Oh","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2015,11,30]]},"reference":[{"issue":"1","key":"9849_CR1","doi-asserted-by":"crossref","first-page":"49","DOI":"10.15441\/ceem.14.008","volume":"1","author":"HK Lee","year":"2014","unstructured":"Lee HK, Kang BS, Kim C, Choi HJ: Ultrasound-guided regional anesthesia for the pain management of elderly patients with hip fractures in the emergency department. Clin Exp Emerg Med 1(1):49\u201355, 2014","journal-title":"Clin Exp Emerg Med"},{"issue":"1","key":"9849_CR2","doi-asserted-by":"crossref","first-page":"16","DOI":"10.15441\/ceem.14.020","volume":"2","author":"C Ahn","year":"2015","unstructured":"Ahn C, Kim C, Kang B, Choi HJ, Cho JH: Variation of availability and frequency of emergency physician-performed ultrasonography between adult and pediatric patients in the academic emergency department in Korea. Clin Exp Emerg Med 2(1):16\u201323, 2015","journal-title":"Clin Exp Emerg Med"},{"issue":"5","key":"9849_CR3","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.2214\/ajr.159.5.1414788","volume":"159","author":"AD Mendlowitz","year":"1992","unstructured":"Mendlowitz AD, Young DK: A system for full-motion real-time telesonography. AJR Am J Roentgenol 159(5):1123\u20131124, 1992","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"9849_CR4","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1258\/jtt.2012.110112","volume":"18","author":"YM Paulus","year":"2012","unstructured":"Paulus YM, Thompson NP: Inexpensive, realtime tele-ultrasound using a commercial, web-based video streaming device. J Telemed Telecare 18(4):185\u2013188, 2012","journal-title":"J Telemed Telecare"},{"issue":"3","key":"9849_CR5","doi-asserted-by":"crossref","first-page":"W219","DOI":"10.2214\/AJR.05.2148","volume":"188","author":"V Popov","year":"2007","unstructured":"Popov V, Popov D, Kacar I, Harris RD: The feasibility of real-time transmission of sonographic images from a remote location over low-bandwidth Internet links: a pilot study. AJR Am J Roentgenol 188(3):W219\u2013W222, 2007","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"9849_CR6","first-page":"54","volume":"22","author":"K Adambounou","year":"2012","unstructured":"Adambounou K, Farin F, Boucher A, Adjenou KV, Gbeassor M, N\u2019dakena K, Vincent N, Arbeille P: System of telesonography with synchronous teleconsultations and asynchronous telediagnoses (Togo). Med Sante Trop 22(1):54\u201360, 2012","journal-title":"Med Sante Trop"},{"key":"9849_CR7","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/1471-227X-12-19","volume":"12","author":"C Ogedegbe","year":"2012","unstructured":"Ogedegbe C, Morchel H, Hazelwood V, Chaplin WF, Feldman J: Development and evaluation of a novel, real time mobile telesonography system in management of patients with abdominal trauma: study protocol. BMC Emerg Med 12:19, 2012","journal-title":"BMC Emerg Med"},{"issue":"12","key":"9849_CR8","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1089\/tmj.2013.0034","volume":"19","author":"P McBeth","year":"2013","unstructured":"McBeth P, Crawford I, Tiruta C, Xiao Z, Zhu GQ, Shuster M, Sewell L, Panebianco N, Lautner D, Nicolaou S, Ball CG, Blaivas M, Dente CJ, Wyrzykowski AD, Kirkpatrick AW: Help is in your pocket: The potential accuracy of smartphone- and laptop-based remotely guided resuscitative telesonography. Telemed J E Health 19(12):924\u2013930, 2013","journal-title":"Telemed J E Health"},{"issue":"1","key":"9849_CR9","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/2036-7902-5-5","volume":"5","author":"N Biegler","year":"2013","unstructured":"Biegler N, McBeth PB, Tiruta C, Hamilton DR, Xiao Z, Crawford I, Tevez-Molina M, Miletic N, Ball CG, Pian L, Kirkpatrick AW: The feasibility of nurse practitioner-performed, telementored lung telesonography with remote physician guidance\u2014\u2018a remote virtual mentor\u2019. Crit Ultrasound J 5(1):5, 2013","journal-title":"Crit Ultrasound J"},{"issue":"6","key":"9849_CR10","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1097\/TA.0b013e318232cca7","volume":"71","author":"PB McBeth","year":"2011","unstructured":"McBeth PB, Crawford I, Blaivas M, Hamilton T, Musselwhite K, Panebianco N, Melniker L, Ball CG, Gargani L, Gherdovich C, Kirkpatrick AW: Simple, almost anywhere, with almost anyone: remote low-cost telementored resuscitative lung ultrasound. J Trauma 71(6):1528\u20131535, 2011","journal-title":"J Trauma"},{"issue":"6","key":"9849_CR11","doi-asserted-by":"crossref","first-page":"1597","DOI":"10.1097\/TA.0b013e3181e61ea9","volume":"69","author":"PB McBeth","year":"2010","unstructured":"McBeth PB, Hamilton T, Kirkpatrick AW: Cost-effective remote iPhone-teathered telementored trauma telesonography. J Trauma 69(6):1597\u20131599, 2010","journal-title":"J Trauma"},{"issue":"2","key":"9849_CR12","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1007\/s10278-012-9512-4","volume":"26","author":"D Martinov","year":"2013","unstructured":"Martinov D, Popov V, Ignjatov Z, Harris RD: Image quality in real-time teleultrasound of infant hip exam over low-bandwidth internet links: a transatlantic feasibility study. J Digit Imaging 26(2):209\u2013216, 2013","journal-title":"J Digit Imaging"},{"issue":"2","key":"9849_CR13","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1002\/jcu.22093","volume":"42","author":"P Arbeille","year":"2014","unstructured":"Arbeille P, Fornage B, Boucher A, Ruiz J, Georgescu M, Blouin J, Cristea J, Carles G, Farin F, Vincent N: Telesonography: virtual 3D image processing of remotely acquired abdominal, vascular, and fetal sonograms. J Clin Ultrasound 42(2):67\u201373, 2014","journal-title":"J Clin Ultrasound"},{"issue":"1","key":"9849_CR14","doi-asserted-by":"crossref","first-page":"E3","DOI":"10.1542\/peds.109.1.e3","volume":"109","author":"CA Sable","year":"2002","unstructured":"Sable CA, Cummings SD, Pearson GD, Schratz LM, Cross RC, Quivers ES, Rudra H, Martin GR: Impact of telemedicine on the practice of pediatric cardiology in community hospitals. Pediatrics 109(1):E3, 2002","journal-title":"Pediatrics"},{"issue":"9","key":"9849_CR15","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1016\/j.ijmedinf.2012.05.011","volume":"81","author":"C Costa","year":"2012","unstructured":"Costa C, Oliveira JL: Telecardiology through ubiquitous Internet services. Int J Med Inform 81(9):612\u2013621, 2012","journal-title":"Int J Med Inform"},{"issue":"1","key":"9849_CR16","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s11235-010-9355-6","volume":"49","author":"F Agboma","year":"2012","unstructured":"Agboma F, Liotta A: Quality of experience management in mobile content delivery system. Telecommun Syst 49(1):85\u201398, 2012. doi: 10.1007\/s11235-010-9355-6","journal-title":"Telecommun Syst"},{"issue":"1","key":"9849_CR17","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1258\/jtt.2011.110412","volume":"18","author":"HJ Choi","year":"2012","unstructured":"Choi HJ, Lee JH, Kang BS: Remote CT reading using an ultramobile PC and web-based remote viewing over a wireless network. J Telemed Telecare 18(1):26\u201331, 2012","journal-title":"J Telemed Telecare"},{"issue":"4","key":"9849_CR18","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1007\/s10278-013-9580-0","volume":"26","author":"JB Park","year":"2013","unstructured":"Park JB, Choi HJ, Lee JH, Kang BS: An assessment of the iPad 2 as a CT teleradiology tool using brain CT with subtle intracranial hemorrhage under conventional illumination. J Digit Imaging 26(4):683\u2013690, 2013","journal-title":"J Digit Imaging"},{"key":"9849_CR19","doi-asserted-by":"crossref","unstructured":"Kim C, Kang B, Choi HJ, Park JB: A feasibility study of real-time remote CT reading for suspected acute appendicitis using an iPhone. J Digit Imaging. 2015 Feb 21","DOI":"10.1007\/s10278-015-9775-7"},{"key":"9849_CR20","unstructured":"iTunes. http:\/\/www.apple.com\/itunes . Accessed April 7 2015. Archived by WebCite\u00ae at http:\/\/www.webcitation.org\/6XcqJOUMs"},{"key":"9849_CR21","unstructured":"Kim C, Kang B, LEE J, Choi HJ: The feasibility and effectiveness study for clinical application of realtime emergency tele-ultrasonography using the LTE smartphone\u2014Pilot study. Presented at: Pan-Pacific Emerg Med Congress. 2014 Oct 14"},{"key":"9849_CR22","unstructured":"Medical Image Perception Laboratory. http:\/\/perception.radiology.uiowa.edu . Accessed April 7 2015. Archived by WebCite\u00ae at http:\/\/www.webcitation.org\/6Xcs81hxF"},{"issue":"1","key":"9849_CR23","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1118\/1.2402583","volume":"34","author":"AS Chawla","year":"2007","unstructured":"Chawla AS, Samei E: Ambient illumination revisited: a new adaptation-based approach for optimizing medical imaging reading environments. Med Phys 34(1):81\u201390, 2007","journal-title":"Med Phys"},{"issue":"1","key":"9849_CR24","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1007\/s10278-012-9522-2","volume":"26","author":"JT Norweck","year":"2013","unstructured":"Norweck JT, Seibert JA, Andriole KP, Clunie DA, Curran BH, Flynn MJ, Krupinski E, Lieto RP, Peck DJ, Mian TA: ACR-AAPM-SIIM technical standard for electronic practice of medical imaging. J Digit Imaging 26(1):38\u201352, 2013","journal-title":"J Digit Imaging"},{"issue":"832","key":"9849_CR25","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1259\/bjr.70.832.9166071","volume":"70","author":"NE Hawass","year":"1997","unstructured":"Hawass NE: Comparing the sensitivities and specificities of two diagnostic procedures performed on the same group of patients. Br Radiol 70(832):360\u2013366, 1997","journal-title":"Br Radiol"},{"key":"9849_CR26","doi-asserted-by":"crossref","unstructured":"Huynh-Thu Q, Ghanbari M: Temporal aspect of perceived quality in mobile video broadcasting. IEEE Tran. Broadcast. 2008 Sep;54(3)","DOI":"10.1109\/TBC.2008.2001246"},{"issue":"2","key":"9849_CR27","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.acra.2010.09.007","volume":"18","author":"SL Hillis","year":"2011","unstructured":"Hillis SL, Obuchowski NA, Berbaum KS: Power estimation for multireader ROC methods an updated and unified approach. Acad Radiol 18(2):129\u2013142, 2011","journal-title":"Acad Radiol"},{"key":"9849_CR28","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1148\/radiology.167.2.3282253","volume":"167","author":"RB Jeffrey Jr","year":"1988","unstructured":"Jeffrey Jr, RB, Laing FC, Townsend RR: Acute appendicitis: sonographic criteria based on 250 cases. Radiology 167:327\u2013329, 1988","journal-title":"Radiology"},{"issue":"1","key":"9849_CR29","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1148\/radiol.10100984","volume":"259","author":"R Krishnamoorthi","year":"2011","unstructured":"Krishnamoorthi R, Ramarajan N, Wang NE, et al: Effectiveness of a staged US and CT protocol for the diagnosis of pediatric appendicitis: reducing radiation exposure in the age of ALARA. Radiology 259(1):231\u2013239, 2011","journal-title":"Radiology"},{"issue":"2","key":"9849_CR30","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1007\/s002470050023","volume":"30","author":"SP Karakas","year":"2000","unstructured":"Karakas SP, Guelfguat M, Leonidas JC, et al: Acute appendicitis in children: comparison of clinical diagnosis with ultrasound and CT imaging. Pediatr Radiol 30(2):94\u201398, 2000","journal-title":"Pediatr Radiol"},{"key":"9849_CR31","doi-asserted-by":"crossref","unstructured":"Kim C, Kang B, Park JB, Ha YR: The use of clinician-performed ultrasonography to determine the treatment method for suspected paediatric appendicitis. Hong Kong J Emerg Med. 2015 Jan;22(1):31\u201340. Availability: http:\/\/www.hkjem.com\/sites\/default\/files\/p31-40.pdf . Accessed April 7 2015. Archived by WebCite\u00ae at http:\/\/www.webcitation.org\/6XcsGbO6G","DOI":"10.1177\/102490791502200104"},{"issue":"2","key":"9849_CR32","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1007\/s00330-008-1176-6","volume":"19","author":"F Wiersma","year":"2009","unstructured":"Wiersma F, Toorenvliet BR, Bloem JL, et al: US examination of the appendix in children with suspected appendicitis: the additional value of secondary signs. Eur Radiol 19(2):455\u2013461, 2009","journal-title":"Eur Radiol"},{"issue":"11","key":"9849_CR33","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1016\/j.acra.2012.06.014","volume":"19","author":"AT Trout","year":"2012","unstructured":"Trout AT, Sanchez R, Ladino-Torres MF: Reevaluating the sonographic criteria for acute appendicitis in children: a review of the literature and a retrospective analysis of 246 cases. Acad Radiol 19(11):1382\u20131394, 2012","journal-title":"Acad Radiol"},{"key":"9849_CR34","unstructured":"The ministry of science, ICT and future planning. http:\/\/www.smartchoice.or.kr\/smc\/smartreport\/evaluateDownload.do . Accessed April 7 2015. Archived by WebCite\u00ae at http:\/\/www.webcitation.org\/6XcsNPQ1r"},{"key":"9849_CR35","unstructured":"The State of the Internet, 4th Quarter, 2014; 7(4). http:\/\/www.akamai.com\/dl\/content\/q4-2014-soti-report.pdf . Accessed April 7 2015. Archived by WebCite\u00ae at http:\/\/www.webcitation.org\/6XcspGrey"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-015-9849-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-015-9849-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-015-9849-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,2]],"date-time":"2019-09-02T02:35:31Z","timestamp":1567391731000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-015-9849-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,30]]},"references-count":35,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,6]]}},"alternative-id":["9849"],"URL":"https:\/\/doi.org\/10.1007\/s10278-015-9849-6","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,30]]}}}