{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T05:40:58Z","timestamp":1773466858736,"version":"3.50.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,3,19]],"date-time":"2019-03-19T00:00:00Z","timestamp":1552953600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2020,2]]},"DOI":"10.1007\/s10278-019-00199-y","type":"journal-article","created":{"date-parts":[[2019,4,17]],"date-time":"2019-04-17T15:31:02Z","timestamp":1555515062000},"page":"64-70","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9646-8801","authenticated-orcid":false,"given":"Ibrahim I.","family":"Suliman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,3,19]]},"reference":[{"key":"199_CR1","unstructured":"United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources and effects of ionizing radiation. 2008 UNSCEAR report to the general assembly with scientific annex. 2010"},{"key":"199_CR2","doi-asserted-by":"crossref","unstructured":"Martin CJ: The importance of radiation quality for optimization in radiology. Biomed Imaging Intervention J 3(2), 2007","DOI":"10.2349\/biij.3.2.e38"},{"issue":"1\u20134","key":"199_CR3","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1093\/rpd\/ncv186","volume":"165","author":"E Elshiekh","year":"2015","unstructured":"Elshiekh E, Suliman II, Habbani F: A comparative study of adult patient doses in film screen and computed radiography in some Sudanese hospitals. Radiat Prot Dosim 165(1\u20134):402\u2013405, 2015","journal-title":"Radiat Prot Dosim"},{"key":"199_CR4","volume-title":"Diagnostic Reference Levels in Thirty-six European Countries Part 2\/2. Radiation protection No. 180","author":"European Commission (EC)","year":"2014","unstructured":"European Commission (EC): Diagnostic Reference Levels in Thirty-six European Countries Part 2\/2. Radiation protection No. 180. Luxembourg: Publications Office of the European Union, 2014"},{"issue":"1","key":"199_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","volume":"46","author":"E Va\u00f1\u00f3","year":"2017","unstructured":"Va\u00f1\u00f3 E, Miller DL, Martin CJ, Rehani MM, Kang K, Rosenstein M, Ortiz-Lopez P, Mattsson S, Padovani R, Rogers A: ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging. Ann ICRP 46(1):1\u2013144, 2017","journal-title":"Ann ICRP"},{"key":"199_CR6","volume-title":"Patient dosimetry for X-rays used in medical imaging. International Commission on Radiation Measurements and Units (ICRU). ICRU Report No. 74","author":"ICRU","year":"2006","unstructured":"ICRU: Patient dosimetry for X-rays used in medical imaging. International Commission on Radiation Measurements and Units (ICRU). ICRU Report No. 74. Bethesda: ICRU, 2006"},{"key":"199_CR7","volume-title":"Dosimetry in diagnostic radiology: An International Code of Practice IAEA TRS. No 457","author":"International Atomic Energy Agency (IAEA)","year":"2007","unstructured":"International Atomic Energy Agency (IAEA): Dosimetry in diagnostic radiology: An International Code of Practice IAEA TRS. No 457. Vienna: IAEA, 2007"},{"key":"199_CR8","volume-title":"National protocol for patient dose measurements in diagnostic radiology (NRPB). Report of the Working Party of the Institute of Physical Science in Medicine","author":"National Radiological Protection Board","year":"1992","unstructured":"National Radiological Protection Board: National protocol for patient dose measurements in diagnostic radiology (NRPB). Report of the Working Party of the Institute of Physical Science in Medicine. Chilton: NRPB, 1992"},{"issue":"6","key":"199_CR9","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1007\/s10278-014-9715-y","volume":"27","author":"A Nitrosi","year":"2014","unstructured":"Nitrosi A, Corazza A, Bertolini M, Sghedoni R, Pattacini P, Iori M: Patient Dose Management Solution Directly Integrated in the RIS: \u201cGray Detector\u201d Software. J Digit Imaging 27(6):786\u2013793, 2014","journal-title":"J Digit Imaging"},{"issue":"6","key":"199_CR10","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1007\/s10278-015-9773-9","volume":"28","author":"J Kim","year":"2015","unstructured":"Kim J, Seo D, Choi I, Nam S, Yoon Y, Kim H, Her J, Han S, Kwon S, Park H, Yang D: Development of Diagnostic Reference Levels Using a Real-Time Radiation Dose Monitoring System at a Cardiovascular Center in Korea. J Digit Imaging 28(6):684\u2013694, 2015","journal-title":"J Digit Imaging"},{"key":"199_CR11","first-page":"1","volume":"34","author":"International Commission on Radiological Protection","year":"2004","unstructured":"International Commission on Radiological Protection: Managing patient dose in digital radiology. ICRP publication 93. Ann ICRP 34:1\u201374, 2004","journal-title":"Ann ICRP"},{"issue":"1","key":"199_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.12816\/0003081","volume":"11","author":"L Al-Lamki","year":"2011","unstructured":"Al-Lamki L: Radiation exposure from medical imaging: a wake-up call for Oman! Sultan Qaboos Univ Med J 11(1):1, 2011","journal-title":"Sultan Qaboos Univ Med J"},{"key":"199_CR13","volume-title":"Medical Electrical Equipment\u2013Part 2-43: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Interventional Procedures, IEC 60601\u20132-43 ed2.0","author":"International Electrotechnical Commission (IEC2010)","year":"2010","unstructured":"International Electrotechnical Commission (IEC2010): Medical Electrical Equipment\u2013Part 2-43: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Interventional Procedures, IEC 60601\u20132-43 ed2.0. Geneva: International Electrotechnical Commission, 2010"},{"key":"199_CR14","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1148\/radiographics.19.5.g99se211289","volume":"19","author":"RA Parry","year":"1999","unstructured":"Parry RA, Sharon AG, Benjamin RA: Typical patient dose in diagnostic radiology: the AAPM\/RSNA physics tutorials for residents. Radiographic 19:1289\u20131302, 1999","journal-title":"Radiographic"},{"key":"199_CR15","doi-asserted-by":"publisher","first-page":"2237","DOI":"10.1088\/0031-9155\/43\/8\/017","volume":"43","author":"N Petoussi-Heness","year":"1998","unstructured":"Petoussi-Heness N, Zankl M, Drexler G, Panzer W, Regulla D: Calculation of backscatter factors of diagnostic radiology using Monte Carlo methods. Phys Med Biol 43:2237\u20132250, 1998","journal-title":"Phys Med Biol"},{"key":"199_CR16","unstructured":"Hart D, Hillier MC, Shrimpton PC: Doses to Patients from Radiographic and Fluoroscopic X-ray Imaging Procedures in the UK-2010 Review. HPA-CRCE-034"},{"key":"199_CR17","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.radmeas.2016.02.017","volume":"87","author":"B Rasuli","year":"2016","unstructured":"Rasuli B, Ghorbani M, Juybari RT: Radiation dose measurement for patients undergoing common spine medical X-ray examinations and proposed local diagnostic reference levels. Radiat Meas 87:29\u201334, 2016","journal-title":"Radiat Meas"},{"key":"199_CR18","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.ejmp.2007.11.002","volume":"24","author":"OA Osibote","year":"2008","unstructured":"Osibote OA, de Azevedo ACP: Estimation of adult patient doses for common diagnostic X-ray examinations in Rio de Janeiro, Brazil. Phys Med 24:21\u201328, 2008","journal-title":"Phys Med"},{"issue":"4","key":"199_CR19","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1093\/rpd\/ncx293","volume":"179","author":"BS Rana","year":"2018","unstructured":"Rana BS, Kumar S, Sandhu IS, Singh NP: Dosimetry Of Adult And Pediatric Patients For Common Digital Radiography Examinations. Radiat Prot Dosim 179(4):349\u2013357, 2018","journal-title":"Radiat Prot Dosim"},{"key":"199_CR20","doi-asserted-by":"crossref","unstructured":"Ibiri NN, Olowookere CJ: Evaluation of dose-area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria. J Appl Clin Med Phys 17(6):392\u2013404","DOI":"10.1120\/jacmp.v17i6.6011"},{"issue":"5","key":"199_CR21","doi-asserted-by":"publisher","first-page":"1439","DOI":"10.1148\/rg.285075748","volume":"28","author":"EL Nickoloff","year":"2008","unstructured":"Nickoloff EL, Lu ZF, Dutta AK, So JC: Radiation dose descriptors: BERT, COD, DAP, and other strange creatures. Radiographics 28(5):1439\u20131450, 2008","journal-title":"Radiographics"},{"key":"199_CR22","unstructured":"International Commission on Radiological Protection (ICRP). The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103, Ann. ICRP 37 ICRP. 2007."},{"issue":"4","key":"199_CR23","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1088\/0952-4746\/36\/4\/975","volume":"36","author":"J Vilar-Palop","year":"2016","unstructured":"Vilar-Palop J, Vilar J, Hern\u00e1ndez-Aguado I, Gonz\u00e1lez-\u00c1lvarez I, Lumbreras B: Updated effective doses in radiology. J Radiol Prot 36(4):975, 2016","journal-title":"J Radiol Prot"},{"issue":"4","key":"199_CR24","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/S1078-8174(98)80011-4","volume":"4","author":"PC Brennan","year":"1998","unstructured":"Brennan PC, Nash M: Increasing FFD: an effective dose-reducing tool for lateral lumbar spine investigations. Radiography 4(4):251\u2013259, 1998","journal-title":"Radiography"},{"issue":"2","key":"199_CR25","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1007\/s00330-001-1166-4","volume":"12","author":"A Herrmann","year":"2002","unstructured":"Herrmann A, Bonel H, Stabler A, Kulinna C, Glaser C, Holzknecht N, Geiger B, Schatzl M, Reiser F: Chest imaging with flat-panel detector at low and standard doses: comparison with storage phosphor technology in normal patients. Eur Radiol 12(2):385\u2013390, 2002","journal-title":"Eur Radiol"},{"issue":"6","key":"199_CR26","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1080\/02841850510021616","volume":"46","author":"B Sj\u00f6holm","year":"2005","unstructured":"Sj\u00f6holm B, Geijer H, Persliden J: Impact of digital imaging on radiation doses to the patient during X-ray examination of the urinary tract. Acta Radiol 46(6):657\u2013661, 2005","journal-title":"Acta Radiol"},{"issue":"2","key":"199_CR27","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/s13246-014-0255-z","volume":"37","author":"II Suliman","year":"2014","unstructured":"Suliman II, Mohammedzein TS: Estimation of adult patient doses for common diagnostic X-ray examinations in Wad-Madani, Sudan: derivation of local diagnostic reference levels. Aust Phys Eng Sci Med 37(2):425\u2013429, 2014","journal-title":"Aust Phys Eng Sci Med"},{"key":"199_CR28","unstructured":"British Institute of Radiology (BIR). Assurance of Quality in the Diagnostic Imaging Department Quality Assurance Working Group of the Radiation Protection Committee of the BIR. UK, 2001."},{"issue":"11","key":"199_CR29","doi-asserted-by":"publisher","first-page":"e1146","DOI":"10.1002\/mp.13212","volume":"45","author":"JK Dave","year":"2018","unstructured":"Dave JK, Jones AK, Fisher R, Hulme K, Rill L, Zamora D, Woodward A, Brady S, MacDougall RD, Goldman L, Lang S: Current state of practice regarding digital radiography exposure indicators and deviation indices: report of AAPM Imaging Physics Committee Task Group 232. Med Phys 45(11):e1146\u2013e1160, 2018","journal-title":"Med Phys"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-019-00199-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-019-00199-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-019-00199-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T03:06:43Z","timestamp":1585105603000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-019-00199-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,19]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2]]}},"alternative-id":["199"],"URL":"https:\/\/doi.org\/10.1007\/s10278-019-00199-y","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,19]]},"assertion":[{"value":"19 March 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"The author declares that he has no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}