{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T01:15:15Z","timestamp":1789175715409,"version":"build-2803163510"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2019,9,13]],"date-time":"2019-09-13T00:00:00Z","timestamp":1568332800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,9,13]],"date-time":"2019-09-13T00:00:00Z","timestamp":1568332800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2020,4]]},"DOI":"10.1007\/s10278-019-00257-5","type":"journal-article","created":{"date-parts":[[2019,9,17]],"date-time":"2019-09-17T08:41:08Z","timestamp":1568709668000},"page":"456-464","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Imaging Properties of Additive Manufactured (3D Printed) Materials for Potential Use for Phantom Models"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5109-1799","authenticated-orcid":false,"given":"Elizabeth","family":"Silvestro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khalil N.","family":"Betts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael L.","family":"Francavilla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Savvas","family":"Andronikou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raymond W.","family":"Sze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,9,13]]},"reference":[{"issue":"5","key":"257_CR1","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1148\/rg.2017160165","volume":"37","author":"E George","year":"2017","unstructured":"George E, Liacouras P, Rybicki FJ, Mitsouras D: Measuring and establishing the accuracy and reproducibility of 3D printed medical models. RadioGraphics. 37(5):1424\u20131450, 2017. \nhttps:\/\/doi.org\/10.1148\/rg.2017160165","journal-title":"RadioGraphics."},{"issue":"7","key":"257_CR2","doi-asserted-by":"publisher","first-page":"1965","DOI":"10.1148\/rg.2015140320","volume":"35","author":"D Mitsouras","year":"2015","unstructured":"Mitsouras D, Liacouras P, Imanzadeh A, Giannopoulos AA, Cai T, Kumamaru KK, George E, Wake N, Caterson EJ, Pomahac B, Ho VB, Grant GT, Rybicki FJ: Medical 3D printing for the radiologist. RadioGraphics. 35(7):1965\u20131988, 2015. \nhttps:\/\/doi.org\/10.1148\/rg.2015140320","journal-title":"RadioGraphics."},{"key":"257_CR3","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1259\/dmfr.20160407","volume":"46","author":"KA Eley","year":"2017","unstructured":"Eley KA, Watt-Smith SR, Golding SJ: \u201cBlack bone\u201d MRI: A novel imaging technique for 3D printing. Dentomaxillofacial Radiol Dentomaxillofac Radiol. 46:46, 2017. \nhttps:\/\/doi.org\/10.1259\/dmfr.20160407","journal-title":"Dentomaxillofacial Radiol Dentomaxillofac Radiol."},{"key":"257_CR4","doi-asserted-by":"publisher","first-page":"033501","DOI":"10.1117\/1.JMI.3.3.033501","volume":"3","author":"S Leng","year":"2016","unstructured":"Leng S, Chen B, Vrieze T, Kuhlmann J, Yu L, Alexander A, Matsumoto J, Morris J, McCollough CH: Construction of realistic phantoms from patient images and a commercial three-dimensional printer. J Med Imaging. 3:033501, 2016. \nhttps:\/\/doi.org\/10.1117\/1.JMI.3.3.033501","journal-title":"J Med Imaging."},{"issue":"7","key":"257_CR5","doi-asserted-by":"publisher","first-page":"1989","DOI":"10.1148\/rg.2015140260","volume":"35","author":"JS Matsumoto","year":"2015","unstructured":"Matsumoto JS, Morris JM, Foley TA, Williamson EE, Leng S, McGee KP, Kuhlmann JL, Nesberg LE, Vrtiska TJ: Three-dimensional physical modeling: Applications and experience at Mayo Clinic. RadioGraphics. 35(7):1989\u20132006, 2015. \nhttps:\/\/doi.org\/10.1148\/rg.2015140260","journal-title":"RadioGraphics."},{"key":"257_CR6","doi-asserted-by":"publisher","unstructured":"Wood S, Krishnamurthy N, Santini T, Raval S, Farhat N, Holmes JA, Ibrahim TS: Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes. PLoS One. 12, 2017. \nhttps:\/\/doi.org\/10.1371\/journal.pone.0183168","DOI":"10.1371\/journal.pone.0183168"},{"key":"257_CR7","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1002\/mrm.25593","volume":"75","author":"JA Kasten","year":"2016","unstructured":"Kasten JA, Vetterli T, Lazeyras F, Van De Ville D: 3D-printed shepp-Logan phantom as a real-world benchmark for MRI. Magn Reson Med. 75:287\u2013294, 2016. \nhttps:\/\/doi.org\/10.1002\/mrm.25593","journal-title":"Magn Reson Med."},{"key":"257_CR8","volume-title":"Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes","author":"C Hazelaar","year":"2017","unstructured":"Hazelaar C, Van Eijnatten M, Dahele M, et al: Using 3D printing techniques to create an anthropomorphic thorax phantom for medical imaging purposes. 2017."},{"key":"257_CR9","doi-asserted-by":"publisher","first-page":"5467","DOI":"10.1002\/mp.12495","volume":"44","author":"L Cervi\u00f1o","year":"2017","unstructured":"Cervi\u00f1o L, Soultan D, Cornell M, Yock A, Pettersson N, Song WY, Aguilera J, Advani S, Murphy J, Hoh C, James C, Paravati A, Coope R, Gill B, Moiseenko V: A novel 3D-printed phantom insert for 4D PET\/CT imaging and simultaneous integrated boost radiotherapy. Med Phys. 44:5467\u20135474, 2017. \nhttps:\/\/doi.org\/10.1002\/mp.12495","journal-title":"Med Phys."},{"key":"257_CR10","doi-asserted-by":"publisher","unstructured":"Javan R, Cho AL: An Assembled Prototype Multimaterial Three-Dimensional\u2013Printed Model of the Neck for Computed Tomography\u2013 and Ultrasound-Guided Interventional Procedures. \nhttps:\/\/doi.org\/10.1097\/RCT.0000000000000630","DOI":"10.1097\/RCT.0000000000000630"},{"key":"257_CR11","doi-asserted-by":"publisher","unstructured":"Ceh J, Youd T, Mastrovich Z, Peterson C, Khan S, Sasser T, Sander I, Doney J, Turner C, Leevy W: Bismuth infusion of ABS enables additive manufacturing of complex radiological phantoms and shielding equipment. Sensors (Switzerland). 17, 2017. \nhttps:\/\/doi.org\/10.3390\/s17030459","DOI":"10.3390\/s17030459"},{"key":"257_CR12","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1007\/s10278-017-9954-9","volume":"30","author":"J Shin","year":"2017","unstructured":"Shin J, Sandhu RS, Shih G: Imaging properties of 3D printed materials: multi-energy CT of filament polymers. J Digit Imaging. 30:572\u2013575, 2017. \nhttps:\/\/doi.org\/10.1007\/s10278-017-9954-9","journal-title":"J Digit Imaging."},{"key":"257_CR13","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1007\/s10439-016-1757-5","volume":"45","author":"F Adams","year":"2017","unstructured":"Adams F, Qiu T, Mark A, Fritz B, Kramer L, Schlager D, Wetterauer U, Miernik A, Fischer P: Soft 3D-printed phantom of the human kidney with collecting system. Ann Biomed Eng. 45:963\u2013972, 2017. \nhttps:\/\/doi.org\/10.1007\/s10439-016-1757-5","journal-title":"Ann Biomed Eng."},{"key":"257_CR14","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1148\/radiol.2016152710","volume":"282","author":"P Jahnke","year":"2017","unstructured":"Jahnke P, Limberg FRP, Gerbl A, Ardila Pardo GL, Braun VPB, Hamm B, Scheel M: Radiopaque three-dimensional printing: A method to create realistic CT phantoms. Radiology. 282:569\u2013575, 2017. \nhttps:\/\/doi.org\/10.1148\/radiol.2016152710","journal-title":"Radiology."},{"key":"257_CR15","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1002\/mrm.26136","volume":"77","author":"D Mitsouras","year":"2017","unstructured":"Mitsouras D, Lee TC, Liacouras P, Ionita CN, Pietilla T, Maier SE, Mulkern RV: Three-dimensional printing of MRI-visible phantoms and MR image-guided therapy simulation. Magn Reson Med. 77:613\u2013622, 2017. \nhttps:\/\/doi.org\/10.1002\/mrm.26136","journal-title":"Magn Reson Med."},{"key":"257_CR16","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1097\/AAP.0000000000000136","volume":"39","author":"SJ West","year":"2014","unstructured":"West SJ, Mari JM, Khan A, Wan JHY, Zhu W, Koutsakos IG, Rowe M, Kamming D, Desjardins AE: Development of an ultrasound phantom for spinal injections with 3-dimensional printing. Regional Anesthesia and Pain Medicine. 39:429\u2013433, 2014. \nhttps:\/\/doi.org\/10.1097\/AAP.0000000000000136","journal-title":"Regional Anesthesia and Pain Medicine."},{"key":"257_CR17","doi-asserted-by":"publisher","first-page":"5913","DOI":"10.1118\/1.4930803","volume":"42","author":"MF Bieniosek","year":"2015","unstructured":"Bieniosek MF, Lee BJ, Levin CS: Technical note: Characterization of custom 3D printed multimodality imaging phantoms. Med Phys. 42:5913\u20135918, 2015. \nhttps:\/\/doi.org\/10.1118\/1.4930803","journal-title":"Med Phys."},{"key":"257_CR18","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1016\/j.medengphy.2011.10.012","volume":"34","author":"M Gatto","year":"2012","unstructured":"Gatto M, Memoli G, Shaw A, Sadhoo N, Gelat P, Harris RA: Three-dimensional printing (3DP) of neonatal head phantom for ultrasound: Thermocouple embedding and simulation of bone. Med Eng Phys. 34:929\u2013937, 2012. \nhttps:\/\/doi.org\/10.1016\/j.medengphy.2011.10.012","journal-title":"Med Eng Phys."},{"key":"257_CR19","doi-asserted-by":"publisher","first-page":"e740","DOI":"10.1002\/mp.13058","volume":"45","author":"V Filippou","year":"2018","unstructured":"Filippou V, Tsoumpas C: Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound. Med Phys. 45:e740\u2013e760, 2018. \nhttps:\/\/doi.org\/10.1002\/mp.13058","journal-title":"Med Phys."}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-019-00257-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10278-019-00257-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-019-00257-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,11]],"date-time":"2020-09-11T23:18:49Z","timestamp":1599866329000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10278-019-00257-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9,13]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,4]]}},"alternative-id":["257"],"URL":"https:\/\/doi.org\/10.1007\/s10278-019-00257-5","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,9,13]]},"assertion":[{"value":"13 September 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interest"}}]}}