{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:02:23Z","timestamp":1740135743780,"version":"3.37.3"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T00:00:00Z","timestamp":1601942400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T00:00:00Z","timestamp":1601942400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2020,12]]},"DOI":"10.1007\/s10278-020-00376-4","type":"journal-article","created":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T19:02:49Z","timestamp":1602010969000},"page":"1543-1553","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Adaptive Voxel Matching for Temporal CT Subtraction"],"prefix":"10.1007","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2498-4289","authenticated-orcid":false,"given":"Toru","family":"Tanaka","sequence":"first","affiliation":[]},{"given":"Ryo","family":"Ishikawa","sequence":"additional","affiliation":[]},{"given":"Keita","family":"Nakagomi","sequence":"additional","affiliation":[]},{"given":"Kazuhiro","family":"Miyasa","sequence":"additional","affiliation":[]},{"given":"Kiyohide","family":"Satoh","sequence":"additional","affiliation":[]},{"given":"Masahiro","family":"Yakami","sequence":"additional","affiliation":[]},{"given":"Thai","family":"Akasaka","sequence":"additional","affiliation":[]},{"given":"Koji","family":"Onoue","sequence":"additional","affiliation":[]},{"given":"Takeshi","family":"Kubo","sequence":"additional","affiliation":[]},{"given":"Mizuho","family":"Nishio","sequence":"additional","affiliation":[]},{"given":"Yutaka","family":"Emoto","sequence":"additional","affiliation":[]},{"given":"Kaori","family":"Togashi","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,10,6]]},"reference":[{"key":"376_CR1","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1118\/1.597308","volume":"21","author":"A Kano","year":"1994","unstructured":"Kano A, Doi K, MacMahon H, Hassell DD, Giger ML: Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys 21:453-461, 1994","journal-title":"Med Phys"},{"key":"376_CR2","doi-asserted-by":"publisher","first-page":"1490","DOI":"10.1109\/TMI.2003.819291","volume":"22","author":"D Loeckx","year":"2003","unstructured":"Loeckx D, Maes F, Vandermeulen D, Suetens P: Temporal subtraction of thorax CR-images using a statistical deformation model. IEEE Trans Med Imaging 22:1490-1504, 2003","journal-title":"IEEE Trans Med Imaging"},{"key":"376_CR3","doi-asserted-by":"publisher","unstructured":"Ishida T, Katsuragawa S, Kawashita I, Kim H, Itai Y, Awai K, Li Q, Doi, K: 3D temporal subtraction on multislice CT images using nonlinear warping technique. Proc. SPIE 6514, Medical Imaging 2007: Computer-Aided Diagnosis, 65143I; https:\/\/doi.org\/10.1117\/12.709004, 2007","DOI":"10.1117\/12.709004"},{"key":"376_CR4","doi-asserted-by":"publisher","first-page":"3457189","DOI":"10.1155\/2017\/3457189","volume":"2017","author":"P Yan","year":"2017","unstructured":"Yan P, Kodera Y, Shimamoto K: Evaluation of deformable image registration for three-dimensional temporal subtraction of chest computed tomography images. Int J Biomed Imaging 2017:3457189. https:\/\/doi.org\/10.1155\/2017\/3457189, 2017","journal-title":"Int J Biomed Imaging"},{"issue":"1","key":"376_CR5","doi-asserted-by":"publisher","first-page":"e85580","DOI":"10.1371\/journal.pone.0085580","volume":"9","author":"R Sakamoto","year":"2014","unstructured":"Sakamoto R, Mori S, Miller MI, Okada T, Togashi K: Detection of time-varying structures by large deformation diffeomorphic metric mapping to aid reading of high-resolution CT images of the lung. PLoS One 9(1):e85580. https:\/\/doi.org\/10.1371\/journal.pone.0085580, 2014","journal-title":"PLoS One"},{"issue":"2","key":"376_CR6","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1148\/radiol.2017161942","volume":"285","author":"R Sakamoto","year":"2017","unstructured":"Sakamoto R, Yakami M, Fujimoto K, Nakagomi K, Kubo T, Emoto Y, Akasaka T, Aoyama G, Yamamoto H, Miller MI, Mori S, Togashi K: Temporal subtraction of serial CT images with large deformation diffeomorphic metric mapping in the identification of bone metastases. Radiology 285(2):629-639, 2017","journal-title":"Radiology"},{"key":"376_CR7","volume-title":"Management of 3D Image Data. Human Remains: Another Dimension","author":"S Decker","year":"2017","unstructured":"Decker S, Ford J: Management of 3D Image Data. Human Remains: Another Dimension. London: Academic Press, 2017"},{"issue":"5","key":"376_CR8","first-page":"257","volume":"35","author":"T Tanaka","year":"2017","unstructured":"Tanaka T, Ishikawa R, Nakagomi K, Satoh K, Yakami M, Akasaka T, Onoue K, Nishio M, Emoto Y, Togashi K: Artifacts reduction in temporal subtraction images of thick-slice CT images (in Japanese). Med Imaging Technol 35(5):257-267, 2017","journal-title":"Med Imaging Technol"},{"issue":"461","key":"376_CR9","first-page":"281","volume":"107","author":"Y Itai","year":"2008","unstructured":"Itai Y, Kim H, Ishikawa S, Katsuragawa S, Doi K: A method for reducing of subtraction artifacts in temporal subtraction image based on voxel matching method. Inst Electron Inf Commun Eng 107(461):281-284, 2008","journal-title":"Inst Electron Inf Commun Eng"},{"key":"376_CR10","doi-asserted-by":"publisher","unstructured":"Itai Y, Kim H, Ishikawa S, Katsuragawa S, Doi K: A new registration method with voxel-matching technique for temporal subtraction images. Proc. SPIE 6915, Medical Imaging 2008: Computer-Aided Diagnosis, 69153I; https:\/\/doi.org\/10.1117\/12.769921, 2008","DOI":"10.1117\/12.769921"},{"issue":"1","key":"376_CR11","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/s10278-008-9169-1","volume":"23","author":"Y Itai","year":"2010","unstructured":"Itai Y, Kim H, Ishikawa S, Katsuragawa S, Doi K: Development of a voxel-matching technique for substantial reduction of subtraction artifacts in temporal subtraction images obtained from thoracic MDCT. J Digit Imaging 23(1):31\u201338, 2010","journal-title":"J Digit Imaging"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-020-00376-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-020-00376-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-020-00376-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,6]],"date-time":"2021-10-06T06:34:29Z","timestamp":1633502069000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-020-00376-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,6]]},"references-count":11,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["376"],"URL":"https:\/\/doi.org\/10.1007\/s10278-020-00376-4","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"type":"print","value":"0897-1889"},{"type":"electronic","value":"1618-727X"}],"subject":[],"published":{"date-parts":[[2020,10,6]]},"assertion":[{"value":"14 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with Ethical Standards"}},{"value":"K. Togashi has received research grants from Bayer AG; DAIICHI SANKYO Group; Eisai Co., Ltd.; FUJIFILM Holdings Corporation; Shimadzu Corporation; and Canon Medical Systems Corporation. T. Tanaka, R. Ishikawa, K. Nakagomi, K. Miyasa, and K. Satoh are Canon Inc. employees. The other authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. For this type of study, formal consent is not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Acquisition of informed consent was waived by the institutional review board because patient data were retrospectively collected in the current study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed Consent"}}]}}