{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,15]],"date-time":"2025-04-15T10:08:04Z","timestamp":1744711684302,"version":"3.37.3"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,6,1]],"date-time":"2021-06-01T00:00:00Z","timestamp":1622505600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1007\/s10278-021-00458-x","type":"journal-article","created":{"date-parts":[[2021,6,22]],"date-time":"2021-06-22T18:05:59Z","timestamp":1624385159000},"page":"717-730","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A Workflow for Ensuring DICOM Compatibility During Radiography Device Software Development"],"prefix":"10.1007","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3983-7222","authenticated-orcid":false,"given":"Altay","family":"Brusan","sequence":"first","affiliation":[]},{"given":"Aytac","family":"Durmaz","sequence":"additional","affiliation":[]},{"given":"Cengizhan","family":"Ozturk","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2021,6,22]]},"reference":[{"key":"458_CR1","unstructured":"ISO - IEC 82304\u20131:2016 - Health software \u2014 part 1: general requirements for product safety, (2016). https:\/\/www.iso.org\/standard\/59543.html (accessed January 12, 2020)."},{"key":"458_CR2","unstructured":"ISO - ISO 14971:2019 - Medical devices \u2014 application of risk management to medical devices, (n.d.). https:\/\/www.iso.org\/standard\/72704.html (accessed January 12, 2020)."},{"key":"458_CR3","unstructured":"IEC 60601\u20131\u20132:2014 | IEC Webstore | electromagnetic compatibility, EMC, smart city, (n.d.). https:\/\/webstore.iec.ch\/publication\/2590 (accessed January 12, 2020)."},{"key":"458_CR4","doi-asserted-by":"publisher","DOI":"10.1111\/1468-0009.12278","author":"JG Ronquillo","year":"2017","unstructured":"J.G. Ronquillo, D.M. Zuckerman, Software-related recalls of health information technology and other medical devices: implications for FDA Regulation of Digital Health, Milbank\u00a0Q. (2017).\u00a0https:\/\/doi.org\/10.1111\/1468-0009.12278.","journal-title":"Milbank Q"},{"key":"458_CR5","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1007\/s10278-014-9748-2","volume":"28","author":"C Oglevee","year":"2015","unstructured":"C. Oglevee, O. Pianykh, Losing images in digital radiology: more than you think, J. Digit. Imaging. 28 (2015) 264\u2013271.\u00a0https:\/\/doi.org\/10.1007\/s10278-014-9748-2.","journal-title":"J Digit Imaging"},{"issue":"8","key":"458_CR6","first-page":"535","volume":"39","author":"M Grissinger","year":"2014","unstructured":"Grissinger M. Oops, sorry, wrong patient!: a patient verification process is needed everywhere, not just at the bedside. P T. 2014;39(8):535\u2013537.","journal-title":"P T"},{"key":"458_CR7","unstructured":"PS3.1\u200b DICOM PS3.1 2019e-Introduction and overview\u200b, 2019. http:\/\/dicom.nema.org\/medical\/dicom\/current\/output\/pdf\/part01.pdf (accessed January 12, 2020)."},{"key":"458_CR8","unstructured":"Digital Imaging and Communications in Medicine (DICOM) Part 2: Conformance,2020. http:\/\/dicom.nema.org\/medical\/dicom\/current\/output\/html\/part02.html(access January 1,2021)"},{"issue":"6","key":"458_CR9","doi-asserted-by":"publisher","first-page":"1381","DOI":"10.1148\/radiographics.13.6.8290731","volume":"13","author":"FW Prior","year":"1993","unstructured":"Prior FW. Specifying DICOM compliance for modality interfaces. Radiographics. 1993 Nov;13(6):1381-8.\u00a0https:\/\/doi.org\/10.1148\/radiographics.13.6.8290731. PMID: 8290731.","journal-title":"Radiographics."},{"key":"458_CR10","unstructured":"Prior F., User conformance profile: DICOM Version 3.0 Compliance. 1994, archive.org. http:\/\/web.archive.org\/web\/19970614021615\/http:\/\/www.xray.hmc.psu.edu\/dicom\/UCP.html (access Jan 2021)"},{"key":"458_CR11","unstructured":"IEC 62304:2006 - Medical device software -- software life cycle processes, 2006. https:\/\/doi.org\/11.040.01 Medical equipment in general."},{"key":"458_CR12","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.scico.2017.07.003","volume":"158","author":"P Arcaini","year":"2018","unstructured":"P. Arcaini, S. Bonfanti, A. Gargantini, A. Mashkoor, E. Riccobene, Integrating formal methods into medical software development: The ASM approach, Sci. Comput. Program. 158 (2018) 148\u2013167.\u00a0https:\/\/doi.org\/10.1016\/j.scico.2017.07.003.","journal-title":"Sci Comput Program"},{"key":"458_CR13","doi-asserted-by":"publisher","unstructured":"R. Jetley, S.P. Iyer, P.L. Jones, A formal methods approach to medical device review, Computer (Long. Beach. Calif). 39 (2006) 61\u201367.\u00a0https:\/\/doi.org\/10.1109\/MC.2006.113.","DOI":"10.1109\/MC.2006.113"},{"key":"458_CR14","doi-asserted-by":"publisher","unstructured":"Richard F. Paige, Nicholas Matragkas, Louis M. Rose, Evolving models in model-driven engineering: state-of-the-art and future challenges, Journal of Systems and Software, Volume 111, 2016, Pages 272-280, ISSN 0164-1212, https:\/\/doi.org\/10.1016\/j.jss.2015.08.047.","DOI":"10.1016\/j.jss.2015.08.047"},{"key":"458_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-019-00304-1","author":"A Brusan","year":"2019","unstructured":"Brusan, A., Durmaz, F.A., Yaman, A. et al. iBEX: modular open-source software for digital radiography. J Digit Imaging (2019)\u00a0https:\/\/doi.org\/10.1007\/s10278-019-00304-1.","journal-title":"J Digit Imaging"},{"key":"458_CR16","unstructured":"Kambalyal, C. (2010). 3-Tier architecture. Retrieved On, 2, 34, 2010."},{"key":"458_CR17","unstructured":"Boochever, Stephen S. HIS\/RIS\/PACS integration: getting to the gold standard. Radiology management 26 3 (2004): 16-24; quiz 25-7"},{"key":"458_CR18","doi-asserted-by":"publisher","unstructured":"Steven G. Langer, Brent K. Stewart, Implementation of an HL7\/DICOM broker for automated patient demographic data entry in computed radiography systems, Proc. SPIE 3339, Medical Imaging 1998: PACS Design and Evaluation: Engineering and Clinical Issues, (13 July 1998);\u00a0https:\/\/doi.org\/10.1117\/12.319815.","DOI":"10.1117\/12.319815"},{"key":"458_CR19","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s10278-010-9331-4","volume":"24","author":"J Philbin","year":"2011","unstructured":"Philbin, J., Prior, F. & Nagy, P. Will the next generation of PACS be sitting on a cloud?. J Digit Imaging 24, 179\u2013183 (2011).\u00a0https:\/\/doi.org\/10.1007\/s10278-010-9331-4","journal-title":"J Digit Imaging"},{"key":"458_CR20","unstructured":"gazelle simulator tools, https:\/\/gazelle.ihe.net\/node\/437 (accessed Jan 01,2021)"},{"key":"458_CR21","unstructured":"Connectathon home page,\u00a0https:\/\/connectathon.ihe-europe.net\/ (access Jan 1,2021)"},{"key":"458_CR22","unstructured":"IHE Radiology (RAD) Technical Framework IHE RAD TF-1 Integration Profiles, IHE International, Inc, 2020, https:\/\/www.ihe.net\/uploadedFiles\/Documents\/Radiology\/IHE_RAD_TF_Vol1.pdf (access Jan 1,2021)"},{"key":"458_CR23","unstructured":"Scheduled Workflow, https:\/\/wiki.ihe.net\/index.php\/Scheduled_Workflow (last access Jan 2,2021)"},{"key":"458_CR24","unstructured":"Patient Information Reconciliation, https:\/\/wiki.ihe.net\/index.php\/Patient_Information_Reconciliation (access Jan 2,2021)"},{"key":"458_CR25","unstructured":"Imaging Object Change Management, https:\/\/wiki.ihe.net\/index.php\/Imaging_Object_Change_Management (access Jan 2021)"},{"issue":"12","key":"458_CR26","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/s1549-3741(04)30082-1","volume":"30","author":"EW Israelski","year":"2004","unstructured":"Israelski EW, Muto WH. Human factors risk management as a way to improve medical device safety: a case study of the therac 25 radiation therapy system. Jt Comm J Qual Saf. 2004 Dec;30(12):689-95.\u00a0https:\/\/doi.org\/10.1016\/s1549-3741(04)30082-1. PMID: 15646102.","journal-title":"Jt Comm J Qual Saf."},{"key":"458_CR27","unstructured":"FDA, General Principles of Software Validation; Final guidance for industry and FDA staff. www.fda.gov\/MedicalDevices\/ (accessed January 13, 2020)."},{"key":"458_CR28","unstructured":"IEC 60601\u20132\u201328:2017 | IEC Webstore | Medical electrical equipment - part 2\u201328: particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis. https:\/\/webstore.iec.ch\/publication\/32908 (accessed January 1, 2021)."},{"key":"458_CR29","unstructured":"IEC 60601\u20132\u201343:2010 | IEC Webstore | Medical electrical equipment - part 2\u201343: particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures. https:\/\/webstore.iec.ch\/publication\/2659 (accessed January 1, 2021)."},{"key":"458_CR30","unstructured":"IEC 60601\u20132\u201344:2009 | IEC Webstore | Medical electrical equipment - part 2\u201344: particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography. https:\/\/webstore.iec.ch\/publication\/2661 (accessed January 1, 2021)."},{"key":"458_CR31","unstructured":"IEC 60601\u20132\u201345:2011 | IEC Webstore | Medical electrical equipment - part 2\u201343: medical electrical equipment - part 2\u201345: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices. https:\/\/webstore.iec.ch\/publication\/2664 (accessed January 1, 2021)."},{"key":"458_CR32","unstructured":"IEC TR 62366\u20132:2016| IEC Webstore | Medical devices - part 2: guidance on the application of usability engineering to medical devices. https:\/\/webstore.iec.ch\/publication\/24664 (accessed January 1, 2021)."},{"key":"458_CR33","unstructured":"Medical Devices; current good manufacturing practice (CGMP) final rule; quality system regulation, 61 Federal Register 52602 (October 7, 1996)."},{"key":"458_CR34","doi-asserted-by":"publisher","unstructured":"Andrew J. Hewett, Hermann Grevemeyer, Andreas Barth, Marco Eichelberg, and Peter F. Jensch Conformance testing of DICOM image objects, Proc. SPIE 3035, Medical Imaging 1997: PACS Design and Evaluation: Engineering and Clinical Issues, (22 May 1997);\u00a0https:\/\/doi.org\/10.1117\/12.27460.","DOI":"10.1117\/12.27460"},{"key":"458_CR35","unstructured":"David A. Clunie, DICOM validator \u2013 Dciodvfy, available at http:\/\/www.dclunie.com\/dicom3tools\/dciodvfy.html (access January 2, 2021)"},{"key":"458_CR36","doi-asserted-by":"publisher","unstructured":"Warnock MJ, Toland C, Evans D, Wallace B, Nagy P. Benefits of using the DCM4CHE DICOM archive. J Digit Imaging. 2007 Nov;20 Suppl 1(Suppl 1):125-9. https:\/\/doi.org\/10.1007\/s10278-007-9064-1. Epub 2007 Oct 5. PMID: 17917780; PMCID: PMC2039778.","DOI":"10.1007\/s10278-007-9064-1"},{"key":"458_CR37","doi-asserted-by":"publisher","unstructured":"Potter G, Busbridge R, Toland M, Nagy P. Mastering DICOM with DVTk. J Digit Imaging. 2007 Nov;20 Suppl 1(Suppl 1):47-62. https:\/\/doi.org\/10.1007\/s10278-007-9057-0. Epub 2007 Aug 7. PMID: 17680308; PMCID: PMC2039858.","DOI":"10.1007\/s10278-007-9057-0"},{"key":"458_CR38","doi-asserted-by":"publisher","unstructured":"S.R. Rakitin, Coping with defective software in medical devices, Computer (Long. Beach. Calif). 39 (2006) 40\u201345. https:\/\/doi.org\/10.1109\/MC.2006.123.","DOI":"10.1109\/MC.2006.123"},{"key":"458_CR39","unstructured":"ISO\/IEC\/IEEE 29119\u20132:2013 Software and systems engineering \u2014 software testing \u2014 Part 2: Test processes. https:\/\/www.iso.org\/standard\/56736.html (accessed January 1, 2021)."},{"key":"458_CR40","unstructured":"ISO\/IEC 25010:2011 Systems and software engineering \u2014 Systems and software Quality Requirements and Evaluation (SQuaRE) \u2014 system and software quality models. https:\/\/www.iso.org\/standard\/35733.html (accessed January 1, 2021)."},{"key":"458_CR41","unstructured":"ISO\/IEC\/IEEE 29119\u20135 First edition 2016\u201311\u201315: ISO\/IEC\/IEEE International Standard - software and systems engineering -- software testing -- part 5: keyword-driven testing., IEEE, 2016."},{"key":"458_CR42","unstructured":"IEC 80001\u20131:2010 Application of risk management for IT-networks incorporating medical devices \u2014 part 1: roles, responsibilities and activities https:\/\/www.iso.org\/standard\/44863.html (access January 1, 2021)"},{"key":"458_CR43","unstructured":"D. Rosenberg, M. Stephens, Use case driven object modeling with UML: theory and practice, 1st ed., Apress, New York, 2007."},{"key":"458_CR44","unstructured":"A. College of Radiology, ACR\u2013AAPM\u2013SIIM-SPR practice parameter for digital radiography; ACR\u2013AAPM\u2013SIIM-SPR practice parameter for digital radiography, n.d. https:\/\/www.acr.org\/-\/media\/ACR\/Files\/Practice-Parameters\/Rad-Digital.pdf, (accessed January 12, 2020)."},{"key":"458_CR45","unstructured":"A. College of Radiology, ACR\u2013AAPM\u2013SIIM technical standard for electronic practice of medical imaging, n.d. https:\/\/www.acr.org\/-\/media\/ACR\/Files\/Practice-Parameters\/Elec-Practice-MedImag.pdf (accessed January 12, 2020)."},{"key":"458_CR46","unstructured":"A. College of Radiology, ACR\u2013AAPM\u2013SIIM practice parameter for electronic medical information privacy and security, n.d. https:\/\/www.acr.org\/-\/media\/ACR\/Files\/Practice-Parameters\/Elec-Info-Privacy.pdf. (accessed January 13, 2020)."},{"key":"458_CR47","unstructured":"DICOM PS3.3 2019e - Information object definitions, (n.d.). http:\/\/dicom.nema.org\/MEDICAL\/Dicom\/current\/output\/chtml\/part03\/PS3.3.html (accessed January 13, 2020)."},{"key":"458_CR48","unstructured":"M. Rausand, A. Hoylan, System reliability theory: models, statistical methods, and applications, Wiley Series in probability and statistics, second edition, 2004."},{"key":"458_CR49","unstructured":"RUP test plan, https:\/\/sceweb.uhcl.edu\/helm\/RationalUnifiedProcess\/process\/templates.htm (access January 2021)"},{"key":"458_CR50","unstructured":"Digital X-Ray Image IOD, http:\/\/dicom.nema.org\/dicom\/2013\/output\/chtml\/part03\/sect_A.26.html (access January 1,2021)"},{"key":"458_CR51","doi-asserted-by":"crossref","unstructured":"O.S. Pianykh, Digital imaging and communications in medicine (DICOM): a practical introduction and survival guide, Springer, 2012.","DOI":"10.1007\/978-3-642-10850-1"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-021-00458-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-021-00458-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-021-00458-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,2]],"date-time":"2021-08-02T17:13:12Z","timestamp":1627924392000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-021-00458-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":51,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["458"],"URL":"https:\/\/doi.org\/10.1007\/s10278-021-00458-x","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"type":"print","value":"0897-1889"},{"type":"electronic","value":"1618-727X"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"9 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}