{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T05:58:14Z","timestamp":1768802294601,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,11,10]],"date-time":"2021-11-10T00:00:00Z","timestamp":1636502400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,11,10]],"date-time":"2021-11-10T00:00:00Z","timestamp":1636502400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2022,2]]},"DOI":"10.1007\/s10278-021-00531-5","type":"journal-article","created":{"date-parts":[[2021,11,10]],"date-time":"2021-11-10T19:02:58Z","timestamp":1636570978000},"page":"77-85","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Evaluation of Apparent Noise on CT Images Using Moving Average Filters"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1063-1872","authenticated-orcid":false,"given":"Keisuke","family":"Fujii","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keiichi","family":"Nomura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kuniharu","family":"Imai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihisa","family":"Muramatsu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"So","family":"Tsushima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Ota","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,11,10]]},"reference":[{"issue":"22","key":"531_CR1","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","volume":"357","author":"DJ Brenner","year":"2007","unstructured":"Brenner DJ, Hall EJ. Computed tomography \u2014 an increasing source of radiation exposure. New England Journal of Medicine 357(22):2277\u20132284, 2007","journal-title":"New England Journal of Medicine"},{"issue":"1","key":"531_CR2","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1148\/radiol.2015141260","volume":"277","author":"G Saiprasad","year":"2015","unstructured":"Saiprasad G, Filliben J, Peskin A, Siegel E, Chen J, Trimble C, Yang Z, Christianson O, Samei E, Krupinski E, Dima A. Evaluation of low-contrast detectability of iterative reconstruction across multiple institutions, CT scanner manufacturers, and radiation exposure levels. Radiology 277(1):124\u2013133, 2015","journal-title":"Radiology"},{"issue":"3","key":"531_CR3","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1148\/radiol.2019191422","volume":"293","author":"A Mileto","year":"2019","unstructured":"Mileto A, Guimaraes LS, McCollough CH, Fletcher JG, Yu L. State of the art in abdominal CT: The limits of iterative reconstruction algorithms. Radiology 293(3):491\u2013503, 2019","journal-title":"Radiology"},{"issue":"4","key":"531_CR4","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1148\/rg.344135128","volume":"34","author":"EC Ehman","year":"2014","unstructured":"Ehman EC, Yu L, Manduca A, Hara AK, Shiung MM, Jondal D, Lake DS, Paden RG, Blezek DJ, Bruesewitz MR, McCollough CH, Hough DM, Fletcher JG. Methods for clinical evaluation of noise reduction techniques in abdominopelvic CT. Radiographics 34(4):849\u2013862, 2014","journal-title":"Radiographics"},{"issue":"2","key":"531_CR5","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1148\/radiol.2018180137","volume":"289","author":"A Mileto","year":"2018","unstructured":"Mileto A, Zamora D, Alessio AM, Pereira C, Liu J, Bhargava P, Carnell J, Cowan SM, Dighe MK, Gunn ML, Kim S, Kolokythas O, Lee JH, Maki JH, Moshiri M, Nasrullah A, O'Malley RB, Schmiedl UP, Soloff EV, Toia GV, Wang CL, Kanal KM. CT detectability of small low-contrast hypoattenuating focal lesions: iterative reconstructions versus filtered back projection. Radiology 289(2):443\u2013454, 2018","journal-title":"Radiology"},{"issue":"2","key":"531_CR6","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1148\/radiol.15142047","volume":"276","author":"CH McCollough","year":"2015","unstructured":"McCollough CH, Yu L, Kofler JM, Leng S, Zhang Y, Li Z, Carter RE. Degradation of CT low-contrast spatial resolution due to the use of iterative reconstruction and reduced dose levels. Radiology 276(2):499\u2013506, 2015","journal-title":"Radiology"},{"issue":"3","key":"531_CR7","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1148\/radiol.2017161736","volume":"284","author":"J Solomon","year":"2017","unstructured":"Solomon J, Marin D, Choudhury KR, Patel B, Samei E. Effect of radiation dose reduction and reconstruction algorithm on image noise, contrast, resolution, and detectability of subtle hypoattenuating liver lesions at multidetector CT: filtered back projection versus a commercial model-based iterative reconstruction algorithm. Radiology 284(3):777\u2013787, 2017","journal-title":"Radiology"},{"issue":"5","key":"531_CR8","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1007\/s00330-016-4571-4","volume":"27","author":"BD Pooler","year":"2017","unstructured":"Pooler BD, Lubner MG, Kim DH, Chen OT, Li K, Chen GH, Pickhardt PJ. Prospective evaluation of reduced dose computed tomography for the detection of low-contrast liver lesions: direct comparison with concurrent standard dose imaging. European Radiology 27(5):2055\u20132066, 2017","journal-title":"European Radiology"},{"issue":"11","key":"531_CR9","doi-asserted-by":"publisher","first-page":"6163","DOI":"10.1007\/s00330-019-06170-3","volume":"29","author":"M Akagi","year":"2019","unstructured":"Akagi M, Nakamura Y, Higaki T, Narita K, Honda Y, Zhou J, Yu Z, Akino N, Awai K. Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT. European Radiology 29(11):6163\u20136171, 2019","journal-title":"European Radiology"},{"issue":"1","key":"531_CR10","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2214\/AJR.19.22332","volume":"215","author":"CT Jensen","year":"2020","unstructured":"Jensen CT, Liu X, Tamm EP, Chandler AG, Sun J, Morani AC, Javadi S, Wagner-Bartak NA. Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience. American Journal of Roentgenology 215(1):50\u201357, 2020","journal-title":"American Journal of Roentgenology"},{"issue":"3","key":"531_CR11","doi-asserted-by":"publisher","first-page":"566","DOI":"10.2214\/AJR.19.21809","volume":"214","author":"R Singh","year":"2020","unstructured":"Singh R, Digumarthy SR, Muse VV, Kambadakone AR, Blake MA, Tabari A, Hoi Y, Akino N, Angel E, Madan R, Kalra MK. Image quality and lesion detection on deep learning reconstruction and iterative reconstruction of submillisievert chest and abdominal CT. American Journal of Roentgenology 214(3):566\u2013573, 2020","journal-title":"American Journal of Roentgenology"},{"issue":"8","key":"531_CR12","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1016\/j.ejmp.2015.08.007","volume":"31","author":"FR Verdun","year":"2015","unstructured":"Verdun FR, Racine D, Ott JG, Tapiovaara MJ, Toroi P, Bochud FO, Veldkamp WJH, Schegerer A, Bouwman RW, Giron IH, Marshall NW, Edyvean S. Image quality in CT: From physical measurements to model observers. Physica Medica 31(8):823\u2013843, 2015","journal-title":"Physica Medica"},{"issue":"3","key":"531_CR13","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1007\/s00234-015-1631-4","volume":"58","author":"T Nakaura","year":"2016","unstructured":"Nakaura T, Iyama Y, Kidoh M, Yokoyama K, Oda S, Tokuyasu S, Harada K, Yamashita Y. Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging. Neuroradiology 58(3):245\u2013251, 2016","journal-title":"Neuroradiology"},{"issue":"10","key":"531_CR14","doi-asserted-by":"publisher","first-page":"6048","DOI":"10.1118\/1.4752209","volume":"39","author":"JB Solomon","year":"2012","unstructured":"Solomon JB, Christianson O, Samei E. Quantitative comparison of noise texture across CT scanners from different manufacturers. Medical Physics 39(10): 6048\u20136055, 2012","journal-title":"Medical Physics"},{"key":"531_CR15","doi-asserted-by":"crossref","unstructured":"Boedeker KL, Cooper VN, McNitt-Gray MF. Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta. Physics in Medicine and Biology 52(14):4027\u20134046, 2007","DOI":"10.1088\/0031-9155\/52\/14\/002"},{"issue":"3","key":"531_CR16","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1088\/0031-9155\/23\/3\/008","volume":"23","author":"SJ Riederer","year":"1978","unstructured":"Riederer SJ, Pelc NJ, Chesler DA. The noise power spectrum in computed x-ray tomography. Physics in Medicine and Biology 23(3):446\u2013454, 1978","journal-title":"Physics in Medicine and Biology"},{"issue":"2","key":"531_CR17","doi-asserted-by":"publisher","first-page":"R1","DOI":"10.1088\/0031-9155\/60\/2\/R1","volume":"60","author":"HH Barrett","year":"2015","unstructured":"Barrett HH, Myers KJ, Hoeschen C, Kupinski MA, Little MP. Task-based measures of image quality and their relation to radiation dose and patient risk. Physics in Medicine and Biology 60(2):R1\u2013R75, 2015","journal-title":"Physics in Medicine and Biology"},{"key":"531_CR18","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.ejmp.2018.04.006","volume":"48","author":"A Viry","year":"2018","unstructured":"Viry A, Aberle C, Racine D, Knebel JF, Schindera ST, Schmidt S, Becce F, Verdun FR. Effects of various generations of iterative CT reconstruction algorithms on low-contrast detectability as a function of the effective abdominal diameter: a quantitative task-based phantom study. Physica Medica 48:111\u2013118, 2018","journal-title":"Physica Medica"},{"key":"531_CR19","unstructured":"Canon Medical Systems Corporation. AiCE deep learning reconstruction: bringing the power of ultra-high resolution CT to routine imaging. Available at: https:\/\/mfl.ssl.cdn.sdlmedia.com\/636837173033229994OU.pdf. Accessed 6 Feb\u00a02021"},{"issue":"2","key":"531_CR20","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1148\/radiology.134.2.7352241","volume":"134","author":"PM Joseph","year":"1980","unstructured":"Joseph PM, Hilal SK, Schulz RA, Kelcz F. Clinical and experimental investigation of a smoothed CT reconstruction algorithm. Radiology 134(2):507\u2013516, 1980","journal-title":"Radiology"},{"key":"531_CR21","unstructured":"International Commission on Radiation Units and Measurements. Radiation dose and image-quality assessment in computed tomography. ICRU Report 87, 2012"},{"key":"531_CR22","doi-asserted-by":"crossref","unstructured":"Solomon J and Samei E. Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE. Medical Physics 41(9): 091908\u20131 \u2013 091908\u201312, 2014","DOI":"10.1118\/1.4893497"},{"issue":"9","key":"531_CR23","doi-asserted-by":"publisher","first-page":"3961","DOI":"10.1002\/mp.14319","volume":"47","author":"J Solomon","year":"2020","unstructured":"Solomon J, Lyu P, Marin D, and Samei E. Noise and spatial resolution properties of a commercially available deep learning-based CT reconstruction algorithm. Medical Physics 47(9): 3961-3971, 2020","journal-title":"Medical Physics"},{"issue":"8","key":"531_CR24","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1177\/0284185113488576","volume":"54","author":"M Matsuki","year":"2013","unstructured":"Matsuki M, Murakami T, Juri H, Yoshikawa S, Narumi Y. Impact of adaptive iterative dose reduction (AIDR) 3D on low-dose abdominal CT: comparison with routine-dose CT using filtered back projection. Acta Radiologica 54(8):869-875, 2013","journal-title":"Acta Radiologica"},{"issue":"1","key":"531_CR25","doi-asserted-by":"publisher","first-page":"127","DOI":"10.2214\/AJR.17.18025","volume":"210","author":"CD Mello-Amoedo","year":"2018","unstructured":"Mello-Amoedo CD, Martins AN, Tachibana A, Pinho DF, Baroni RH. Comparison of radiation dose and image quality of abdominopelvic CT using iterative (AIDR 3D) and conventional reconstructions. American Journal of Roentgenology 210(1):127\u2013133, 2018","journal-title":"American Journal of Roentgenology"},{"key":"531_CR26","doi-asserted-by":"crossref","unstructured":"Zhang X, Chen J, Yu N, Ren Z, Tian Q, Tian X, He T, Guo C. Improving image quality with model-based iterative reconstruction at quarter of nominal dose in upper abdominal CT. British Journal of Radiology 92(1093) 20180137\u20131 - 20180137\u20137, 2019","DOI":"10.1259\/bjr.20180137"},{"key":"531_CR27","doi-asserted-by":"crossref","unstructured":"Steuwe A, Weber M, Bethge OT, Rademacher C, Boschheidgen M, Sawicki LM, Antoch G, Aissa J et al. Influence of a novel deep-learning based reconstruction software on the objective and subjective image quality in low-dose abdominal computed tomography. British Journal of Radiology 94(1117) 20200677\u20131 - 20200677\u20139, 2021","DOI":"10.1259\/bjr.20200677"},{"key":"531_CR28","doi-asserted-by":"crossref","unstructured":"Vaishnav JY, Jung WC, Popescu LM, Zeng R, Myers KJ. Objective assessment of image quality and dose reduction in CT iterative reconstruction. Medical Physics 41(7): 071904\u20131 - 071904\u201312, 2014","DOI":"10.1118\/1.4881148"}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-021-00531-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-021-00531-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-021-00531-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T15:12:46Z","timestamp":1645110766000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-021-00531-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,10]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["531"],"URL":"https:\/\/doi.org\/10.1007\/s10278-021-00531-5","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,10]]},"assertion":[{"value":"6 April 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 September 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 November 2021","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The dimensional data of the standard- and obese-sized phantoms created in this study was retrospectively collected from clinical data, and this study was approved by ethics review board of National Cancer Center.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}