{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T16:30:35Z","timestamp":1781022635444,"version":"3.54.1"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T00:00:00Z","timestamp":1641945600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T00:00:00Z","timestamp":1641945600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"published-print":{"date-parts":[[2022,4]]},"DOI":"10.1007\/s10278-021-00580-w","type":"journal-article","created":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T17:02:52Z","timestamp":1642006972000},"page":"327-334","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["The Improvement of Patient Centering in Computed Tomography Through a Technologist-Focused Education Initiative"],"prefix":"10.1007","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8617-0753","authenticated-orcid":false,"given":"Lindsay","family":"DeWeese","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Griglock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Moody","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron","family":"Mehlberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Celeste","family":"Winters","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,12]]},"reference":[{"issue":"5","key":"580_CR1","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.2214\/AJR.16.17215","volume":"208","author":"TP Szczykutowicz","year":"2017","unstructured":"Szczykutowicz TP, DuPlissis A, Pickhardt PJ. Variation in CT Number and Image Noise Uniformity According to Patient Positioning in MDCT. AJR Am J Roentgenol. May 2017;208(5):1064-1072. https:\/\/doi.org\/10.2214\/AJR.16.17215","journal-title":"AJR Am J Roentgenol."},{"issue":"3","key":"580_CR2","doi-asserted-by":"publisher","first-page":"102","DOI":"10.4329\/wjr.v4.i3.102","volume":"4","author":"MS Kim","year":"2012","unstructured":"Kim MS, Singh S, Halpern E, Saini S, Kalra MK. Ablation margin assessment of liver tumors with intravenous contrast-enhanced C-arm computed tomography. World J Radiol. Mar 28 2012;4(3):102-8. https:\/\/doi.org\/10.4329\/wjr.v4.i3.102","journal-title":"World J Radiol."},{"issue":"7","key":"580_CR3","doi-asserted-by":"publisher","first-page":"3093","DOI":"10.1118\/1.2748113","volume":"34","author":"T Toth","year":"2007","unstructured":"Toth T, Ge Z, Daly MP. The influence of patient centering on CT dose and image noise. Med Phys. Jul 2007;34(7):3093-101. https:\/\/doi.org\/10.1118\/1.2748113","journal-title":"Med Phys."},{"issue":"3","key":"580_CR4","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.ejmp.2011.06.002","volume":"28","author":"MA Habibzadeh","year":"2012","unstructured":"Habibzadeh MA, Ay MR, Asl AR, Ghadiri H, Zaidi H. Impact of miscentering on patient dose and image noise in x-ray CT imaging: phantom and clinical studies. Phys Med. Jul 2012;28(3):191-9. https:\/\/doi.org\/10.1016\/j.ejmp.2011.06.002","journal-title":"Phys Med."},{"issue":"4","key":"580_CR5","doi-asserted-by":"publisher","first-page":"1514","DOI":"10.1002\/mp.12137","volume":"44","author":"RM Marsh","year":"2017","unstructured":"Marsh RM, Silosky MS. The effects of patient positioning when interpreting CT dose metrics: A phantom study. Med Phys. Apr 2017;44(4):1514-1524. https:\/\/doi.org\/10.1002\/mp.12137","journal-title":"Med Phys."},{"issue":"6","key":"580_CR6","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/acm2.12594","volume":"20","author":"I Barreto","year":"2019","unstructured":"Barreto I, Lamoureux R, Olguin C, et al. Impact of patient centering in CT on organ dose and the effect of using a positioning compensation system: Evidence from OSLD measurements in postmortem subjects. Journal of Applied Clinical Medical Physics. 2019;20(6):141-151. https:\/\/doi.org\/10.1002\/acm2.12594","journal-title":"Journal of Applied Clinical Medical Physics."},{"issue":"11","key":"580_CR7","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1097\/rli.0000000000000482","volume":"53","author":"N Saltybaeva","year":"2018","unstructured":"Saltybaeva N, Schmidt B, Wimmer A, Flohr T, Alkadhi H. Precise and Automatic Patient Positioning in Computed Tomography. Investigative Radiology. 2018;53(11):641-646. https:\/\/doi.org\/10.1097\/rli.0000000000000482","journal-title":"Investigative Radiology."},{"key":"580_CR8","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-020-07629-4","author":"Y Gang","year":"2021","unstructured":"Gang Y, Chen X, Li H, et al. A comparison between manual and artificial intelligence\u2013based automatic positioning in CT imaging for COVID-19 patients. European Radiology. 2021.\u00a0https:\/\/doi.org\/10.1007\/s00330-020-07629-4","journal-title":"European Radiology."},{"issue":"5","key":"580_CR9","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.2214\/AJR.15.15466","volume":"206","author":"C Heilmaier","year":"2016","unstructured":"Heilmaier C, Zuber N, Bruijns B, Weishaupt D. Does Real-Time Monitoring of Patient Dose With Dose Management Software Increase CT Technologists' Radiation Awareness? AJR Am J Roentgenol. May 2016;206(5):1049-55. https:\/\/doi.org\/10.2214\/AJR.15.15466","journal-title":"AJR Am J Roentgenol."},{"issue":"1","key":"580_CR10","doi-asserted-by":"publisher","first-page":"123","DOI":"10.2214\/AJR.13.12028","volume":"203","author":"T Kaasalainen","year":"2014","unstructured":"Kaasalainen T, Palmu K, Reijonen V, Kortesniemi M. Effect of patient centering on patient dose and image noise in chest CT. AJR Am J Roentgenol. Jul 2014;203(1):123-30. https:\/\/doi.org\/10.2214\/AJR.13.12028","journal-title":"AJR Am J Roentgenol."},{"issue":"3","key":"580_CR11","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1067\/j.cpradiol.2018.02.007","volume":"48","author":"OO Akin-Akintayo","year":"2019","unstructured":"Akin-Akintayo OO, Alexander LF, Neill R, et al. Prevalence and Severity of Off-Centering During Diagnostic CT: Observations From 57,621 CT scans of the Chest, Abdomen, and\/or Pelvis. Curr Probl Diagn Radiol. May - Jun 2019;48(3):229-234. https:\/\/doi.org\/10.1067\/j.cpradiol.2018.02.007","journal-title":"Curr Probl Diagn Radiol. May -"},{"issue":"4","key":"580_CR12","doi-asserted-by":"publisher","first-page":"2079","DOI":"10.1007\/s00330-018-5745-z","volume":"29","author":"R Booij","year":"2019","unstructured":"Booij R, Budde RPJ, Dijkshoorn ML, Van Straten M. Accuracy of automated patient positioning in CT using a 3D camera for body contour detection. European Radiology. 2019;29(4):2079-2088. https:\/\/doi.org\/10.1007\/s00330-018-5745-z","journal-title":"European Radiology."},{"issue":"4","key":"580_CR13","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1007\/s10278-016-9861-5","volume":"29","author":"PM Cheng","year":"2016","unstructured":"Cheng PM. Patient Vertical Centering and Correlation with Radiation Output in Adult Abdominopelvic CT. J Digit Imaging. Aug 2016;29(4):428-37. https:\/\/doi.org\/10.1007\/s10278-016-9861-5","journal-title":"J Digit Imaging."}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-021-00580-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-021-00580-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-021-00580-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T15:23:05Z","timestamp":1744125785000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-021-00580-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,12]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["580"],"URL":"https:\/\/doi.org\/10.1007\/s10278-021-00580-w","relation":{},"ISSN":["0897-1889","1618-727X"],"issn-type":[{"value":"0897-1889","type":"print"},{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,12]]},"assertion":[{"value":"12 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was submitted to the Institutional Review Board (IRB) at Oregon Health & Science University. The IRB determined the study is not research involving human subjects and therefore IRB oversight was not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"Thomas Griglock is a member of the Scientific Advisory Board for Imalogix\u2122. No other authors have disclosures.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}