{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T17:34:50Z","timestamp":1778175290253,"version":"3.51.4"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T00:00:00Z","timestamp":1682553600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T00:00:00Z","timestamp":1682553600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003125","name":"Suomen Kulttuurirahasto","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003125","id-type":"DOI","asserted-by":"publisher"}]},{"name":"University of Turku (UTU) including Turku University Central Hospital"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Carimas is a multi-purpose medical imaging data processing tool, which can be used to visualize, analyze, and model different medical images in research. Originally, it was developed only for positron emission tomography data in 2009, but the use of this software has extended to many other tomography imaging modalities, such as computed tomography and magnetic resonance imaging. Carimas is especially well-suited for analysis of three- and four-dimensional image data and creating polar maps in modeling of cardiac perfusion. This article explores various parts of Carimas, including its key features, program structure, and application possibilities.<\/jats:p>","DOI":"10.1007\/s10278-023-00812-1","type":"journal-article","created":{"date-parts":[[2023,4,27]],"date-time":"2023-04-27T20:24:19Z","timestamp":1682627059000},"page":"1885-1893","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":43,"title":["Carimas: An Extensive Medical Imaging Data Processing Tool for Research"],"prefix":"10.1007","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7775-7656","authenticated-orcid":false,"given":"Oona","family":"Rainio","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunlei","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9401-0725","authenticated-orcid":false,"given":"Jarmo","family":"Teuho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6549-8749","authenticated-orcid":false,"given":"Sergey V.","family":"Nesterov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vesa","family":"Oikonen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sauli","family":"Piirola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timo","family":"Laitinen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marko","family":"T\u00e4tt\u00e4l\u00e4inen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3156-9593","authenticated-orcid":false,"given":"Juhani","family":"Knuuti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0982-8360","authenticated-orcid":false,"given":"Riku","family":"Kl\u00e9n","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,4,27]]},"reference":[{"key":"812_CR1","doi-asserted-by":"publisher","first-page":"1594","DOI":"10.1007\/s00259-009-1143-8","volume":"36","author":"SV Nesterov","year":"2009","unstructured":"S.V. Nesterov, C. Han, M. M\u00e4ki, S. Kajander, A.G. Naum, H. Helenius, I. Lisinen, H. Ukkonen, M. Pietil\u00e4, E. Joutsiniemi, J. Knuuti, Myocardial perfusion quantitation with 15O-labelled water PET: high reproducibility of the new cardiac analysis software (Carimas\u2122). Eur J Nucl Med Mol Imaging, 36, (2009), pp. 1594\u20131602.","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"812_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/jcbfm.1983.1","volume":"3","author":"CS Patlak","year":"1983","unstructured":"C.S. Patlak, R.G. Blasberg, J.D. Fenstermacher, Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J. Cereb. Blood Flow Metab. 3, (1983), pp. 1\u20137.","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"812_CR3","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1016\/S0969-8051(00)00137-2","volume":"27","author":"J Logan","year":"2000","unstructured":"J. Logan, Graphical analysis of PET data applied to reversible and irreversible tracers. Nucl. Med. Biol. 27, (2000), pp. 661\u2013670.","journal-title":"Nucl. Med. Biol."},{"key":"812_CR4","first-page":"711","volume":"36","author":"JA Thie","year":"1995","unstructured":"J.A. Thie, Clarification of a fractional uptake concept. J. Nucl. Med. 36, (1995), pp. 711\u2013712.","journal-title":"J. Nucl. Med."},{"issue":"2","key":"812_CR5","doi-asserted-by":"crossref","first-page":"133","DOI":"10.47102\/annals-acadmedsg.V33N2p133","volume":"33","author":"DW Townsend","year":"2004","unstructured":"D.W. Townsend, Physical principles and technology of clinical PET imaging. Annals-Academy of Medicine Singapore, 33, 2, (2004), pp. 133-145.","journal-title":"Annals-Academy of Medicine Singapore"},{"issue":"6","key":"812_CR6","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1097\/00004647-200106000-00002","volume":"21","author":"RN Gunn","year":"2001","unstructured":"R.N. Gunn, S.R. Gunn, V.J. Cunningham, Positron Emission Tomography Compartmental Models. Journal of Cerebral Blood Flow & Metabolism, 21, 6, (2001), pp. 635-652.","journal-title":"Journal of Cerebral Blood Flow & Metabolism"},{"key":"812_CR7","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1016\/S1071-3581(96)90059-8","volume":"3","author":"TR DeGrado","year":"1996","unstructured":"T.R. DeGrado, M.W. Hanson, T.G. Turkington, D.M. Delong, D.A. Brezinski, J.-P. Vall\u00e9e, L.W. Hedlund, J. Zhang, F. Cobb, M.J. Sullivan, R.E. Coleman, Estimation of myocardial blood flow for longitudinal studies with 13N-labeled ammonia and positron emission tomography. J Nucl Cardiol 3, (1996) pp. 494\u2013507","journal-title":"J Nucl Cardiol"},{"issue":"5","key":"812_CR8","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1016\/0735-1097(90)90237-J","volume":"15","author":"GD Hutchins","year":"1990","unstructured":"G.D. Hutchins, M. Schwaiger, K.C. Rosenspire, J. Krivokapich, H. Schelbert, D.E. Kuhl, Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imaging. J Am Coll Cardiol. 15, 5, (1990), pp. 1032-42.","journal-title":"J Am Coll Cardiol."},{"key":"812_CR9","doi-asserted-by":"crossref","unstructured":"J. Krivokapich, G.T. Smith, S.C. Huang, E.J. Hoffman, O. Ratib, M.E. Phelps, H.R. Schelbert, 13N ammonia myocardial imaging at rest and with exercise in normal volunteers. Quantification of absolute myocardial perfusion with dynamic positron emission tomography. Circulation, 80, 5, (1989), pp. 1328-37.","DOI":"10.1161\/01.CIR.80.5.1328"},{"key":"812_CR10","doi-asserted-by":"crossref","unstructured":"M.D. Cerqueira, N.J. Weissman, V. Dilsizian, A.K. Jacobs, S. Kaul, W.K. Laskey, D.J. Pennell, J.A. Rumberger, T. Ryan, M.S. Verani, American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation, 105, 4, (2002) pp. 539-542.","DOI":"10.1161\/hc0402.102975"},{"key":"812_CR11","unstructured":"G.S. Lin, H.H. Hines, G. Grant, K. Taylor, C. Ryals, Automated Quantification of Myocardial Ischemia and Wall Motion Defects by Use of Cardiac SPECT Polar Mapping and 4-Dimensional Surface Rendering. Journal of Nuclear Medicine Technology March, 34, 1, (2006), pp. 3-17."},{"issue":"4","key":"812_CR12","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1115\/1.2796031","volume":"118","author":"KD Costa","year":"1996","unstructured":"K.D. Costa, P.J. Hunter, J.M. Rogers, J.M. Guccione, L.K. Waldman, A.D. McCulloch, A Three-Dimensional Finite Element Method for Large Elastic Deformations of Ventricular Myocardium: I\u2013Cylindrical and Spherical Polar Coordinates. J Biomech Eng., 118, 4, (1996), pp. 452-463.","journal-title":"J Biomech Eng."},{"key":"812_CR13","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1007\/s002590050301","volume":"25","author":"SG Nekolla","year":"1998","unstructured":"S.G. Nekolla, C. Miethaner, N. Nguyen, S.I. Ziegler, M. Schwaiger, Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography. European Journal of Nuclear Medicine, 25, (1998), pp. 1313\u20131321.","journal-title":"European Journal of Nuclear Medicine"},{"key":"812_CR14","doi-asserted-by":"crossref","unstructured":"M. Anttinen, O. Ettala, S. Malaspina, I. Jambor, M. Sandell, S. Kajander, I. Rinta-Kiikka, J. Schildt, E. Saukko, P. Rautio, K.L. Timonen, T. Matikainen, T. Noponen, J. Saunavaara, E. L\u00f6yttyniemi, P. Taime, J. Kemppainen, P.B. Dean, R.B. Sequeiros, H.J.Aronen, M. Sepp\u00e4nen, P.J. Bostr\u00f6m. (2021). A Prospective Comparison of 18F-prostate-specific Membrane Antigen-1007 Positron Emission Tomography Computed Tomography, Whole-body 1.5 T Magnetic Resonance Imaging with Diffusion-weighted Imaging, and Single-photon Emission Computed Tomography\/Computed Tomography with Traditional Imaging in Primary Distant Metastasis Staging of Prostate Cancer (PROSTAGE). European Urology Oncology, 4(4), 635-644","DOI":"10.1016\/j.euo.2020.06.012"},{"issue":"11","key":"812_CR15","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1016\/j.jcmg.2016.10.025","volume":"10","author":"T Maaniitty","year":"2017","unstructured":"T. Maaniitty, I. Stenstr\u00f6m, J.J. Bax, V. Uusitalo, H. Ukkonen, S. Kajander, M. M\u00e4ki, A. Saraste, J. Knuuti, Prognostic Value of Coronary CT Angiography With Selective PET Perfusion Imaging in Coronary Artery Disease. JACC Cardiovasc Imaging. 10, 11, (2017), pp. 1361-1370.","journal-title":"JACC Cardiovasc Imaging."},{"key":"812_CR16","unstructured":"J. Liedes, H. Hellstr\u00f6m, O. Rainio, S. Murtoj\u00e4rvi, S. Malaspina, J. Hirvonen, R. Kl\u00e9n, J. Kemppainen. (2022). Automatic segmentation of head and neck cancer from PET-MRI data using deep learning. [Manuscript]."}],"container-title":["Journal of Digital Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-023-00812-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-023-00812-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-023-00812-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,11]],"date-time":"2023-12-11T16:43:23Z","timestamp":1702313003000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-023-00812-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,27]]},"references-count":16,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,8]]}},"alternative-id":["812"],"URL":"https:\/\/doi.org\/10.1007\/s10278-023-00812-1","relation":{},"ISSN":["1618-727X"],"issn-type":[{"value":"1618-727X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,27]]},"assertion":[{"value":"15 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2023","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The medical images shown in Figs.\u00a0,, andare from the studies [,], and [], respectively. All three studies were approved by Ethics Committee of the Hospital District of Southwest Finland and their participants were at least 18 years of age and consented to research use of their data. Figure\u00a0is from taken from an older version of\u00a0the official site of Carimas.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval and Consent to Participate"}},{"value":"J.K. received consultation fees from GE Healthcare and AstraZeneca and speaker fees from GE Healthcare, Bayer, Lundbeck, Boehringer-Ingelheim, Pfizer, Merck, and Siemens, outside the submitted work.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}