{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T09:49:37Z","timestamp":1767260977998,"version":"3.37.3"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,10]],"date-time":"2024-01-10T00:00:00Z","timestamp":1704844800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,10]],"date-time":"2024-01-10T00:00:00Z","timestamp":1704844800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"DOI":"10.1007\/s10278-023-00902-0","type":"journal-article","created":{"date-parts":[[2024,1,10]],"date-time":"2024-01-10T18:01:32Z","timestamp":1704909692000},"page":"167-179","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Generating PET Attenuation Maps via Sim2Real Deep Learning\u2013Based Tissue Composition Estimation Combined with MLACF"],"prefix":"10.1007","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8388-2904","authenticated-orcid":false,"given":"Tetsuya","family":"Kobayashi","sequence":"first","affiliation":[]},{"given":"Yui","family":"Shigeki","sequence":"additional","affiliation":[]},{"given":"Yoshiyuki","family":"Yamakawa","sequence":"additional","affiliation":[]},{"given":"Yumi","family":"Tsutsumida","sequence":"additional","affiliation":[]},{"given":"Tetsuro","family":"Mizuta","sequence":"additional","affiliation":[]},{"given":"Kohei","family":"Hanaoka","sequence":"additional","affiliation":[]},{"given":"Shota","family":"Watanabe","sequence":"additional","affiliation":[]},{"given":"Daisuke","family":"Morimoto\u2011Ishikawa","sequence":"additional","affiliation":[]},{"given":"Takahiro","family":"Yamada","sequence":"additional","affiliation":[]},{"given":"Hayato","family":"Kaida","sequence":"additional","affiliation":[]},{"given":"Kazunari","family":"Ishii","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,1,10]]},"reference":[{"key":"902_CR1","volume-title":"PET: Molecular imaging and its biological applications","author":"ME Phelps","year":"2012","unstructured":"Phelps ME. PET: Molecular imaging and its biological applications. New York: Springer; 2012."},{"key":"902_CR2","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.cpet.2007.12.002","volume":"2","author":"Z Habib","year":"2007","unstructured":"Habib Z, Montandon M, Alavi A. Advances in attenuation correction techniques in PET. PET Clin. 2007;2:191\u2013217. https:\/\/doi.org\/10.1016\/j.cpet.2007.12.002.","journal-title":"PET Clin."},{"key":"902_CR3","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.cpet.2007.10.003","volume":"2","author":"Z Habib","year":"2007","unstructured":"Habib Z, Montandon M. Scatter compensation techniques in PET. PET Clin. 2007;2:219\u2013234. https:\/\/doi.org\/10.1016\/j.cpet.2007.10.003.","journal-title":"PET Clin."},{"key":"902_CR4","volume-title":"Correction techniques in emission tomography","author":"D Mohammad","year":"2012","unstructured":"Mohammad D, Jiang X, Sch\u00e4fers K. Correction techniques in emission tomography. Boca Raton: CRC Press; 2012."},{"key":"902_CR5","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1007\/s00259-002-0796-3","volume":"29","author":"C Burger","year":"2002","unstructured":"Burger C, Goerres G, Schoenes S, Buck A, Lonn AHR, Von Schulthess GK. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging. 2002;29:922\u2013927. https:\/\/doi.org\/10.1007\/s00259-002-0796-3.","journal-title":"Eur J Nucl Med Mol Imaging."},{"key":"902_CR6","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1016\/j.neuroimage.2016.12.010","volume":"147","author":"CN Ladefoged","year":"2017","unstructured":"Ladefoged CN, Law I, Anazoda U, Lawrence KS, Izquierdo-Garcia D, Catana C, et al. A multi-centre evaluation of eleven clinically feasible brain PET\/MRI attenuation correction techniques using a large cohort of patients. Neuroimage. 2017;147:346\u2013359. https:\/\/doi.org\/10.1016\/j.neuroimage.2016.12.010.","journal-title":"Neuroimage."},{"key":"902_CR7","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1007\/s002590050282","volume":"25","author":"DL Bailey","year":"1998","unstructured":"Bailey DL. Transmission scanning in emission tomography. Eur J Nucl Med. 1998;25:774\u2013787. https:\/\/doi.org\/10.1007\/s002590050282.","journal-title":"Eur J Nucl Med."},{"issue":"4","key":"902_CR8","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1088\/0031-9155\/57\/4\/885","volume":"57","author":"M Defrise","year":"2012","unstructured":"Defrise M, Ahmadreza R, Nuyts J. Time-of-flight PET data determine the attenuation sinogram up to a constant.\u00a0Phys Med Biol.\u00a02012;57.4:885. https:\/\/doi.org\/10.1088\/0031-9155\/57\/4\/885","journal-title":"Phys Med Biol."},{"issue":"2","key":"902_CR9","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1118\/1.4938264","volume":"43","author":"Y Berker","year":"2016","unstructured":"Berker Y, Li Y. Attenuation correction in emission tomography using the emission data\u2014a review. Med Phys. 2016;43.2:807-832. https:\/\/doi.org\/10.1118\/1.4938264","journal-title":"Med Phys."},{"issue":"7","key":"902_CR10","doi-asserted-by":"publisher","first-page":"2542","DOI":"10.1088\/1361-6560\/aa5e99","volume":"62","author":"H Bal","year":"2017","unstructured":"Bal H, Panin VY, Platsch G, Defrise M, Hayden G, Hutton C, Serrano B, Paulmier B, Casey ME. Evaluation of MLACF based calculated attenuation brain PET imaging for FDG patient studies. Phys Med Biol. 2017;62.7:2542. https:\/\/doi.org\/10.1088\/1361-6560\/aa5e99","journal-title":"Phys Med Biol."},{"key":"902_CR11","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1186\/s40658-022-00518-3","volume":"9","author":"D Morimoto-Ishikawa","year":"2022","unstructured":"Morimoto-Ishikawa D, Hanaoka K, Watanabe S, Yamada T, Yamakawa Y, Minagawa S, Tekenouchi S, Ohtani A, Mizuta T, Kaida H, Ishii K. Evaluation of the performance of a high-resolution time-of-flight PET system dedicated to the head and breast according to NEMA NU 2-2012 standard. EJNMMI Phys. 2022;9:88. https:\/\/doi.org\/10.1186\/s40658-022-00518-3.","journal-title":"EJNMMI Phys."},{"key":"902_CR12","doi-asserted-by":"publisher","unstructured":"Kobayashi T, Kitamura K. A solution for scaling problem in joint estimation of activity and attenuation. 2017 IEEE NSS\/MIC, Atlanta, GA, USA. 2017:1\u20135. https:\/\/doi.org\/10.1109\/NSSMIC.2017.8532856.","DOI":"10.1109\/NSSMIC.2017.8532856"},{"key":"902_CR13","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1007\/s12149-022-01721-z","volume":"36","author":"T Mizuta","year":"2022","unstructured":"Mizuta T, Kobayashi T, Yamakawa Y, Hanaoka K, Watanabe S, Morimoto-Ishikawa D, Yamada T, Kaida H, Ishii K. Initial evaluation of a new maximum-likelihood attenuation correction factor-based attenuation correction for time-of-flight brain PET. Ann Nucl Med. 2022;36:420\u2013426. https:\/\/doi.org\/10.1007\/s12149-022-01721-z.","journal-title":"Ann Nucl Med."},{"key":"902_CR14","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1109\/JPROC.2019.2936809","volume":"108","author":"K Gong","year":"2019","unstructured":"Gong K, Berg E, Cherry S, Qi J. Machine learning in PET: from photon detection to quantitative image reconstruction. Proc IEEE. 2019;108:51\u201368. https:\/\/doi.org\/10.1109\/JPROC.2019.2936809.","journal-title":"Proc IEEE."},{"key":"902_CR15","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.ejmp.2020.07.028","volume":"76","author":"T Wang","year":"2020","unstructured":"Wang T, Lei Y, Curran WJ, Liu T, Nye JA, Yang X. Machine learning in quantitative PET: A review of attenuation correction and low-count image reconstruction methods. Phys Med. 2020;76:294\u2013306. https:\/\/doi.org\/10.1016\/j.ejmp.2020.07.028.","journal-title":"Phys Med."},{"key":"902_CR16","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.ejmp.2021.03.008","volume":"83","author":"H Arabi","year":"2021","unstructured":"Arabi H, Allaf AA, Sanaat A, Shiri I, Zaidi H. The promise of artificial intelligence and deep learning in PET and SPECT imaging. Phys Med. 2021;83:122\u2013137. https:\/\/doi.org\/10.1016\/j.ejmp.2021.03.008.","journal-title":"Phys Med."},{"key":"902_CR17","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1109\/TRPMS.2020.3009269","volume":"5","author":"JS Lee","year":"2020","unstructured":"Lee JS. A review of deep-learning-based approaches for attenuation correction in positron emission tomography. IEEE Trans Radiat Plasma Med Sci. 2020;5:160\u2013184. https:\/\/doi.org\/10.1109\/TRPMS.2020.3009269.","journal-title":"IEEE Trans Radiat Plasma Med Sci."},{"key":"902_CR18","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1007\/s10334-012-0353-4","volume":"26","author":"G Wagenknecht","year":"2013","unstructured":"Wagenknecht G, Kaiser HJ, Mottaghy MF, Herzog H. MRI for attenuation correction in PET: methods and challenges. MAGMA. 2013;26:99\u2013113. https:\/\/doi.org\/10.1007\/s10334-012-0353-4.","journal-title":"MAGMA."},{"key":"902_CR19","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1109\/TMI.2014.2318175","volume":"33","author":"R Ahmadreza","year":"2014","unstructured":"Ahmadreza R, Defrise M, Nuyts J. ML-reconstruction for TOF-PET with simultaneous estimation of the attenuation factors. IEEE Trans Med Imaging. 2014;33:1563\u20131572. https:\/\/doi.org\/10.1109\/TMI.2014.2318175.","journal-title":"IEEE Trans Med Imaging."},{"key":"902_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1145\/3197517.3201275","volume":"37","author":"Y Aksoy","year":"2018","unstructured":"Aksoy Y, Oh T, Paris S, Pollefeys M, Matusik W. Semantic soft segmentation. ACM Trans Graph. 2018;37:1-13. https:\/\/doi.org\/10.1145\/3197517.3201275.","journal-title":"ACM Trans Graph."},{"key":"902_CR21","doi-asserted-by":"publisher","unstructured":"Ronneberger O, Fischer P, Brox T. U-Net: Convolutional networks for biomedical image segmentation. In: Navab N, Hornegger J, Wells W, Frangi A, editors. Medical Image Computing and Computer-Assisted Intervention. MICCAI 2015. Lecture Notes in Computer Science, vol. 9351. Springer; 2015. https:\/\/doi.org\/10.1007\/978-3-319-24574-4_28","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"902_CR22","doi-asserted-by":"publisher","first-page":"153","DOI":"10.2967\/jnumed.122.264080","volume":"64","author":"K Ishii","year":"2023","unstructured":"Ishii K, Hanaoka K, Watanabe S, Morimoto-Ishikawa D, Yamada T, Kaida H, Yamakawa Y, Minagawa S, Takenouchi S, Ohtani A, Mizuta T. High-resolution silicon photomultiplier time-of-flight dedicated head PET system for clinical brain studies. J Nucl Med. 2023;64:153\u2013158. https:\/\/doi.org\/10.2967\/jnumed.122.264080.","journal-title":"J Nucl Med."},{"key":"902_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40658-018-0225-8","volume":"5","author":"F Liu","year":"2018","unstructured":"Liu F, Jang H, Kijowski R, Zhao G, Bradshaw T, McMillan AB. A deep learning approach for 18F-FDG PET attenuation correction. EJNMMI Phys. 2018;5:1\u201315. https:\/\/doi.org\/10.1186\/s40658-018-0225-8.","journal-title":"EJNMMI Phys."},{"key":"902_CR24","doi-asserted-by":"publisher","first-page":"215016","DOI":"10.1088\/1361-6560\/ab4eb7","volume":"64","author":"X Dong","year":"2019","unstructured":"Dong X, Wang T, Lei Y, Higgins K, Liu T, Curran WJ, Mai H, Nye JA, Yang X. Synthetic CT generation from non-attenuation corrected PET images for whole-body PET imaging. Phys Med Biol. 2019;64:215016. https:\/\/doi.org\/10.1088\/1361-6560\/ab4eb7.","journal-title":"Phys Med Biol."},{"key":"902_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13550-020-00644-y","volume":"10","author":"K Armanious","year":"2020","unstructured":"Armanious K, Hepp T, K\u00fcstner T, Dittman H, Nikolaou K, La Fougere C, Yang B, Gatidis S. Independent attenuation correction of whole body [18F] FDG-PET using a deep learning approach with Generative Adversarial Networks. EJNMMI Res. 2020;10:1\u20139. https:\/\/doi.org\/10.1186\/s13550-020-00644-y.","journal-title":"EJNMMI Res."},{"key":"902_CR26","doi-asserted-by":"publisher","first-page":"1410","DOI":"10.1109\/TMI.2006.883453","volume":"25","author":"B Aubert-Broche","year":"2006","unstructured":"Aubert-Broche B, Griffin M, Pike GB, Evans AC, Collins DL. Twenty new digital brain phantoms for creation of validation image data bases. IEEE Trans Med Imaging. 2006;25:1410\u20131416. https:\/\/doi.org\/10.1109\/TMI.2006.883453.","journal-title":"IEEE Trans Med Imaging."},{"key":"902_CR27","doi-asserted-by":"publisher","unstructured":"Watson CC, Newport DF, Casey ME. A single scatter simulation technique for scatter correction in 3D PET. In: Grangeat P, Amans JL, editors.\u00a0Three-dimensional image reconstruction in radiology and nuclear medicine. Computation imaging and vision, vol. 4. Dordrecht: Springer; 1996. pp. 255\u2013268. https:\/\/doi.org\/10.1007\/978-94-015-8749-5_18.","DOI":"10.1007\/978-94-015-8749-5_18"},{"key":"902_CR28","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1109\/42.363108","volume":"13","author":"HM Hudson","year":"1994","unstructured":"Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging. 1994;13:601\u2013609. https:\/\/doi.org\/10.1109\/42.363108.","journal-title":"IEEE Trans Med Imaging."},{"key":"902_CR29","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1007\/s12149-021-01611-w","volume":"35","author":"F Hashimoto","year":"2021","unstructured":"Hashimoto F, Ito M, Ote K, Isobe T, Okada H, Ouchi Y. Deep learning-based attenuation correction for brain PET with various radiotracers. Ann Nucl Med. 2021;35:691\u2013701. https:\/\/doi.org\/10.1007\/s12149-021-01611-w.","journal-title":"Ann Nucl Med."},{"key":"902_CR30","unstructured":"Kingma DP, Ba AJ. A method for stochastic optimization. ArXiv e-prints [Internet]. 2014. Available from: http:\/\/arxiv.org\/abs\/1412.6980. Accessed\u00a013 Nov 2023."},{"key":"902_CR31","unstructured":"Abadi M, Agarwal A, Barham P, Brevdo E, Chen Z, Citro C, et al. TensorFlow: large-scale machine learning on heterogeneous distributed systems. ArXiv e-prints [Internet]. 2016. Available from: http:\/\/arxiv.org\/abs\/1603.04467. Accessed 13 Nov 2023."},{"key":"902_CR32","doi-asserted-by":"publisher","unstructured":"Nakayama T, Kudo H. Derivation and implementation of ordered-subsets algorithms for list-mode PET data. IEEE Nucl Sci Symp Conf Rec, Fajardo, PR, USA. 2005;4:1954. https:\/\/doi.org\/10.1109\/NSSMIC.2005.1596714","DOI":"10.1109\/NSSMIC.2005.1596714"},{"key":"902_CR33","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1109\/42.563664","volume":"16","author":"F Maes","year":"1997","unstructured":"Maes F, Collignon A, Vandermeulen D, Marchal G, Suetens P. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imaging. 1997;16:187\u2013198. https:\/\/doi.org\/10.1109\/42.563664","journal-title":"IEEE Trans Med Imaging."}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-023-00902-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-023-00902-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-023-00902-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T15:15:10Z","timestamp":1709306110000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-023-00902-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,10]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["902"],"URL":"https:\/\/doi.org\/10.1007\/s10278-023-00902-0","relation":{},"ISSN":["2948-2933"],"issn-type":[{"type":"electronic","value":"2948-2933"}],"subject":[],"published":{"date-parts":[[2024,1,10]]},"assertion":[{"value":"19 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"There are no procedures requiring ethics approval relevant to this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"There are no procedures requiring informed consent relevant to this article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"All authors have approved the manuscript and agree with the submission.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}},{"value":"Tetsuya Kobayashi, Yui Shigeki, Yoshiyuki Yamakawa, Yumi Tsutsumida, and Tetsuro Mizuta are employees of Shimadzu Corp. There are no other potential conflicts of interest relevant to this article.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}]}}