{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T08:12:23Z","timestamp":1772784743350,"version":"3.50.1"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T00:00:00Z","timestamp":1710374400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T00:00:00Z","timestamp":1710374400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004955","name":"\u00d6sterreichische Forschungsf\u00f6rderungsgesellschaft","doi-asserted-by":"publisher","award":["858060"],"award-info":[{"award-number":["858060"]}],"id":[{"id":"10.13039\/501100004955","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005788","name":"Medical University of Vienna","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005788","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The introduction of three-dimensional (3D) printed anatomical models has garnered interest in pre-operative planning, especially in orthopedic and trauma surgery. Identifying potential error sources and quantifying their effect on the model dimensional accuracy are crucial for the applicability and reliability of such models. In this study, twenty radii were extracted from anatomic forearm specimens and subjected to osteotomy to simulate a defined fracture of the distal radius (Colles\u2019 fracture). Various factors, including two different computed tomography (CT) technologies (energy-integrating detector (EID) and photon-counting detector (PCD)), four different CT scanners, two scan protocols (i.e., routine and high dosage), two different scan orientations, as well as two segmentation algorithms were considered to determine their effect on 3D model accuracy. Ground truth was established using 3D reconstructions of surface scans of the physical specimens. Results indicated that all investigated variables significantly impacted the\u00a03D model accuracy\u00a0(<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). However, the mean absolute deviation fell within the range of 0.03\u2009\u00b1\u20090.20 to 0.32\u2009\u00b1\u20090.23\u00a0mm, well below the 0.5\u00a0mm threshold necessary for pre-operative planning. Intra- and inter-operator variability demonstrated fair to excellent agreement for 3D model accuracy, with an intra-class correlation (ICC)\u00a0of 0.43 to 0.92. This systematic investigation displayed dimensional deviations in the magnitude of sub-voxel imaging resolution for all variables. Major pitfalls included missed or overestimated bone regions during the segmentation process, necessitating additional manual editing of 3D models. In conclusion, this study demonstrates that 3D bone fracture models can be obtained with clinical routine scanners and scan protocols, utilizing a simple global segmentation threshold, thereby providing an accurate and reliable tool for pre-operative planning.<\/jats:p>","DOI":"10.1007\/s10278-024-00998-y","type":"journal-article","created":{"date-parts":[[2024,3,14]],"date-time":"2024-03-14T16:02:35Z","timestamp":1710432155000},"page":"1889-1901","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Accuracy Analysis of 3D Bone Fracture Models: Effects of Computed Tomography (CT) Imaging and Image Segmentation"],"prefix":"10.1007","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8740-3923","authenticated-orcid":false,"given":"Martin","family":"Bittner-Frank","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7320-0279","authenticated-orcid":false,"given":"Andreas","family":"Strassl","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0275-9988","authenticated-orcid":false,"given":"Ewald","family":"Unger","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5194-9118","authenticated-orcid":false,"given":"Lena","family":"Hirtler","sequence":"additional","affiliation":[]},{"given":"Barbara","family":"Eckhart","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4671-6701","authenticated-orcid":false,"given":"Markus","family":"Koenigshofer","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0029-6748","authenticated-orcid":false,"given":"Alexander","family":"Stoegner","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9001-7732","authenticated-orcid":false,"given":"Arastoo","family":"Nia","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8580-2314","authenticated-orcid":false,"given":"Domenik","family":"Popp","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1823-971X","authenticated-orcid":false,"given":"Franz","family":"Kainberger","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6321-1804","authenticated-orcid":false,"given":"Reinhard","family":"Windhager","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0279-6615","authenticated-orcid":false,"given":"Francesco","family":"Moscato","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9029-7172","authenticated-orcid":false,"given":"Emir","family":"Benca","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,3,14]]},"reference":[{"key":"998_CR1","doi-asserted-by":"publisher","first-page":"E200023011","DOI":"10.5435\/JAAOSGlobal-D-20-00230","volume":"5","author":"CM Wixted","year":"2021","unstructured":"C.M. Wixted, J.R. Peterson, R.J. Kadakia, S.B. Adams, Three-dimensional Printing in Orthopaedic Surgery: Current Applications and Future Developments, J. Am. Acad. Orthop. Surg. Glob. Res. Rev. 5 (2021) E200023011. https:\/\/doi.org\/10.5435\/JAAOSGlobal-D-20-00230.","journal-title":"J. Am. Acad. Orthop. Surg. Glob. Res. Rev."},{"key":"998_CR2","doi-asserted-by":"publisher","unstructured":"D.G. Alemayehu, Z. Zhang, E. Tahir, D. Gateau, D.F. Zhang, X. Ma, Preoperative Planning Using 3D Printing Technology in Orthopedic Surgery, Biomed Res. Int. 2021 (2021). https:\/\/doi.org\/10.1155\/2021\/7940242.","DOI":"10.1155\/2021\/7940242"},{"key":"998_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-63219-w","volume":"10","author":"S Shen","year":"2020","unstructured":"S. Shen, P.Z. Wang, X.Y. Li, X. Han, H.L. Tan, Pre-operative simulation using a three-dimensional printing model for surgical treatment of old and complex tibial plateau fractures, Sci. Rep. 10 (2020) 1\u201311. https:\/\/doi.org\/10.1038\/s41598-020-63219-w.","journal-title":"Sci. Rep."},{"key":"998_CR4","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1016\/j.surg.2015.12.017","volume":"159","author":"N Martelli","year":"2016","unstructured":"N. Martelli, C. Serrano, H. Van Den Brink, J. Pineau, P. Prognon, I. Borget, S. El Batti, Advantages and disadvantages of 3-dimensional printing in surgery: A systematic review, Surg. (United States). 159 (2016) 1485\u20131500. https:\/\/doi.org\/10.1016\/j.surg.2015.12.017.","journal-title":"Surg. (United States)."},{"key":"998_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12938-016-0236-4","volume":"15","author":"P Tack","year":"2016","unstructured":"P. Tack, J. Victor, P. Gemmel, L. Annemans, 3D-printing techniques in a medical setting: A systematic literature review, Biomed. Eng. Online. 15 (2016) 1\u201321. https:\/\/doi.org\/10.1186\/s12938-016-0236-4.","journal-title":"Biomed. Eng. Online."},{"key":"998_CR6","doi-asserted-by":"publisher","first-page":"13","DOI":"10.2217\/3dp-2021-0021","volume":"6","author":"G Traynor","year":"2022","unstructured":"G. Traynor, A.I. Shearn, E.G. Milano, M.V. Ordonez, M.N. Velasco Forte, M. Caputo, S. Schievano, H. Mustard, J. Wray, G. Biglino, The use of 3D-printed models in patient communication: a scoping review, J. 3D Print. Med. 6 (2022) 13\u201323. https:\/\/doi.org\/10.2217\/3dp-2021-0021.","journal-title":"J. 3D Print. Med."},{"key":"998_CR7","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s12891-019-2448-9","volume":"20","author":"C Chen","year":"2019","unstructured":"C. Chen, L. Cai, W. Zheng, J. Wang, X. Guo, H. Chen, The efficacy of using 3D printing models in the treatment of fractures: A randomised clinical trial, BMC Musculoskelet. Disord. 20 (2019) 4\u201311. https:\/\/doi.org\/10.1186\/s12891-019-2448-9.","journal-title":"BMC Musculoskelet. Disord."},{"key":"998_CR8","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s11548-010-0476-x","volume":"5","author":"F Rengier","year":"2010","unstructured":"F. Rengier, A. Mehndiratta, H. Von Tengg-Kobligk, C.M. Zechmann, R. Unterhinninghofen, H.U. Kauczor, F.L. Giesel, 3D printing based on imaging data: Review of medical applications, Int. J. Comput. Assist. Radiol. Surg. 5 (2010) 335\u2013341. https:\/\/doi.org\/10.1007\/s11548-010-0476-x.","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"998_CR9","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1016\/j.injury.2007.05.020","volume":"38","author":"C Hurson","year":"2007","unstructured":"C. Hurson, A. Tansey, B. O\u2019Donnchadha, P. Nicholson, J. Rice, J. McElwain, Rapid prototyping in the assessment, classification and preoperative planning of acetabular fractures, Injury. 38 (2007) 1158\u20131162. https:\/\/doi.org\/10.1016\/j.injury.2007.05.020.","journal-title":"Injury."},{"key":"998_CR10","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.jcot.2018.04.008","volume":"9","author":"M Javaid","year":"2018","unstructured":"M. Javaid, A. Haleem, Additive manufacturing applications in orthopaedics: A review, J. Clin. Orthop. Trauma. 9 (2018) 202\u2013206. https:\/\/doi.org\/10.1016\/j.jcot.2018.04.008.","journal-title":"J. Clin. Orthop. Trauma."},{"key":"998_CR11","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1177\/1553350614547773","volume":"22","author":"N Bizzotto","year":"2015","unstructured":"N. Bizzotto, A. Sandri, D. Regis, D. Romani, I. Tami, B. Magnan, Three-Dimensional Printing of Bone Fractures: A New Tangible Realistic Way for Preoperative Planning and Education, Surg. Innov. 22 (2015) 548\u2013551. https:\/\/doi.org\/10.1177\/1553350614547773.","journal-title":"Surg. Innov."},{"key":"998_CR12","doi-asserted-by":"publisher","unstructured":"H. Liang, H. Zhang, B. Chen, L. Yang, R. Xu, S. Duan, 3D printing technology combined with personalized plates for complex distal intra \u2013 articular fractures of the trimalleolar ankle, Sci. Rep. (2023) 1\u20139. https:\/\/doi.org\/10.1038\/s41598-023-49515-1.","DOI":"10.1038\/s41598-023-49515-1"},{"key":"998_CR13","doi-asserted-by":"publisher","first-page":"976","DOI":"10.1016\/j.injury.2016.01.013","volume":"47","author":"N Bizzotto","year":"2016","unstructured":"N. Bizzotto, I. Tami, A. Tami, A. Spiegel, D. Romani, M. Corain, R. Adani, B. Magnan, 3D Printed models of distal radius fractures, Injury. 47 (2016) 976\u2013978. https:\/\/doi.org\/10.1016\/j.injury.2016.01.013.","journal-title":"Injury."},{"key":"998_CR14","doi-asserted-by":"publisher","unstructured":"E. Benca,\u00a0B. Eckhart, A. Stoegner, E. Unger,\u00a0 M. Bittner-Frank,\u00a0A. Strassl,\u00a0C. Gahleitner,\u00a0L. Hirtler,\u00a0 R. Windhager,\u00a0 G.M. Hobusch,\u00a0F. Moscato, Dimensional accuracy and precision and surgeon perception of additively manufactured bone models: effect of manufacturing technology and part orientation. Abstract 3D Printing in Medicine 10 (2024). https:\/\/doi.org\/10.1186\/s41205-024-00203-4.","DOI":"10.1186\/s41205-024-00203-4"},{"key":"998_CR15","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1007\/s11548-019-02110-0","volume":"15","author":"S Weidert","year":"2020","unstructured":"S. Weidert, S. Andress, C. Linhart, E.M. Suero, A. Greiner, W. B\u00f6cker, C. Kammerlander, C.A. Becker, 3D printing method for next-day acetabular fracture surgery using a surface filtering pipeline: feasibility and 1-year clinical results, Int. J. Comput. Assist. Radiol. Surg. 15 (2020) 565\u2013575. https:\/\/doi.org\/10.1007\/s11548-019-02110-0.","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"998_CR16","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1177\/1753193417735001","volume":"43","author":"PWL ten Berg","year":"2018","unstructured":"P.W.L. ten Berg, J.G.G. Dobbe, G.J. Streekstra, Three-dimensional printed anatomical models in scaphoid surgery Dear, J. Hand Surg. Eur. Vol. 43 (2018) 100\u2013101. https:\/\/doi.org\/10.1177\/1753193417735001.","journal-title":"J. Hand Surg. Eur."},{"key":"998_CR17","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1016\/j.jhsa.2013.02.024","volume":"38","author":"T Kataoka","year":"2013","unstructured":"T. Kataoka, K. Oka, J. Miyake, S. Omori, H. Tanaka, T. Murase, 3-Dimensional Prebent Plate Fixation in Corrective Osteotomy of Malunited Upper Extremity Fractures Using a Real-Sized Plastic Bone Model Prepared By Preoperative Computer Simulation, J. Hand Surg. Am. 38 (2013) 909\u2013919. https:\/\/doi.org\/10.1016\/j.jhsa.2013.02.024.","journal-title":"J. Hand Surg. Am."},{"key":"998_CR18","doi-asserted-by":"publisher","unstructured":"H. Beli\u00ebn, H. Biesmans, A. Steenwerckx, E. Bijnens, C. Dierickx, Prebending of osteosynthesis plate using 3D printed models to treat symptomatic os acromiale and acromial fracture, J. Exp. Orthop. 4 (2017). https:\/\/doi.org\/10.1186\/s40634-017-0111-7.","DOI":"10.1186\/s40634-017-0111-7"},{"key":"998_CR19","doi-asserted-by":"publisher","first-page":"S53","DOI":"10.1016\/j.injury.2022.08.069","volume":"53","author":"A D\u2019Amelio","year":"2022","unstructured":"A. D\u2019Amelio, E.M.M. Van Lieshout, A.M. Wakker, M.H.J. Verhofstad, M.G. Van Vledder, 3D-printed patient specific instruments for corrective osteotomies of the lower extremity, Injury. 53 (2022) S53\u2013S58. https:\/\/doi.org\/10.1016\/j.injury.2022.08.069.","journal-title":"Injury."},{"key":"998_CR20","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1007\/s11751-017-0284-8","volume":"12","author":"RJO de Muinck Keizer","year":"2017","unstructured":"R.J.O. de Muinck Keizer, K.M. Lechner, M.A.M. Mulders, N.W.L. Schep, D. Eygendaal, J.C. Goslings, Three-dimensional virtual planning of corrective osteotomies of distal radius malunions: a systematic review and meta-analysis, Strateg. Trauma Limb Reconstr. 12 (2017) 77\u201389. https:\/\/doi.org\/10.1007\/s11751-017-0284-8.","journal-title":"Trauma Limb Reconstr."},{"key":"998_CR21","doi-asserted-by":"publisher","first-page":"160","DOI":"10.3109\/10929080109146002","volume":"6","author":"H Croitoru","year":"2000","unstructured":"H. Croitoru, R.E. Ellis, C.F. Small, D.R. Pichora, Fixation-based surgery: A new technique for distal radius osteotomy, Comput. Aided Surg. 6 (2000) 160\u2013169. https:\/\/doi.org\/10.3109\/10929080109146002.","journal-title":"Comput. Aided Surg."},{"key":"998_CR22","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1097\/BTH.0b013e31821da4b5","volume":"15","author":"RK De Oliveira","year":"2011","unstructured":"R.K. De Oliveira, P.J.D. Serrano, A. Badia, M.T. Ferreira, Corrective osteotomy after damage of the distal radial physis in children: Surgical technique and results, Tech. Hand Up. Extrem. Surg. 15 (2011) 236\u2013242. https:\/\/doi.org\/10.1097\/BTH.0b013e31821da4b5.","journal-title":"Hand Up. Extrem. Surg."},{"key":"998_CR23","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1016\/j.ejrad.2010.10.007","volume":"80","author":"V Bagaria","year":"2011","unstructured":"V. Bagaria, S. Deshpande, D.D. Rasalkar, A. Kuthe, B.K. Paunipagar, Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures, Eur. J. Radiol. 80 (2011) 814\u2013820. https:\/\/doi.org\/10.1016\/j.ejrad.2010.10.007.","journal-title":"Eur. J. Radiol."},{"key":"998_CR24","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.medengphy.2017.10.008","volume":"51","author":"M van Eijnatten","year":"2018","unstructured":"M. van Eijnatten, R. van Dijk, J. Dobbe, G. Streekstra, J. Koivisto, J. Wolff, CT image segmentation methods for bone used in medical additive manufacturing, Med. Eng. Phys. 51 (2018) 6\u201316. https:\/\/doi.org\/10.1016\/j.medengphy.2017.10.008.","journal-title":"Med. Eng. Phys."},{"key":"998_CR25","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1108\/RPJ-07-2015-0092","volume":"23","author":"M Van Eijnatten","year":"2017","unstructured":"M. Van Eijnatten, F.H. Berger, P. De Graaf, J. Koivisto, T. Forouzanfar, J. Wolff, Influence of CT parameters on STL model accuracy, Rapid Prototyp. J. 23 (2017) 678\u2013685. https:\/\/doi.org\/10.1108\/RPJ-07-2015-0092.","journal-title":"Rapid Prototyp. J."},{"key":"998_CR26","unstructured":"B. Schmutz, M.E. Wullschleger, M. a Schuetz, The effect of CT slice spacing on the geometry of 3D models, Proc. 6th Australasion Biomech. Conf. (2007) 93\u201394."},{"key":"998_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0214123","volume":"14","author":"ML Comrie","year":"2019","unstructured":"M.L. Comrie, G. Monteith, A. Zur Linden, M. Oblak, J. Phillips, F.M.K. James, The accuracy of computed tomography scans for rapid prototyping of canine skulls, PLoS One. 14 (2019) 1\u201310. https:\/\/doi.org\/10.1371\/journal.pone.0214123.","journal-title":"PLoS One."},{"key":"998_CR28","doi-asserted-by":"publisher","first-page":"226","DOI":"10.1016\/j.medengphy.2010.10.002","volume":"33","author":"K Rathnayaka","year":"2011","unstructured":"K. Rathnayaka, T. Sahama, M.A. Schuetz, B. Schmutz, Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions, Med. Eng. Phys. 33 (2011) 226\u2013233. https:\/\/doi.org\/10.1016\/j.medengphy.2010.10.002.","journal-title":"Med. Eng. Phys."},{"key":"998_CR29","doi-asserted-by":"publisher","first-page":"e524","DOI":"10.1016\/j.ejrad.2011.06.001","volume":"81","author":"Z Fourie","year":"2012","unstructured":"Z. Fourie, J. Damstra, R.H. Schepers, P.O. Gerrits, Y. Ren, Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography, Eur. J. Radiol. 81 (2012) e524\u2013e530. https:\/\/doi.org\/10.1016\/j.ejrad.2011.06.001.","journal-title":"Eur. J. Radiol."},{"key":"998_CR30","doi-asserted-by":"publisher","first-page":"188","DOI":"10.3109\/10929080802195783","volume":"13","author":"F Gelaude","year":"2008","unstructured":"F. Gelaude, J. Vander Sloten, B. Lauwers, Accuracy assessment of CT-based outer surface femur meshes, Comput. Aided Surg. 13 (2008) 188\u2013199. https:\/\/doi.org\/10.3109\/10929080802195783.","journal-title":"Comput. Aided Surg."},{"key":"998_CR31","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1002\/rcs","volume":"5","author":"K Oka","year":"2009","unstructured":"K. Oka, T. Murase, H. Moritomo, A. Goto, K. Sugamoto, H. Yoshikawa, Accuracy analysis of three-dimensional bone surface models of the forearm constructed from multidetector computed tomography data, Int. J. Comput. Assist. Radiol. Surg. 5 (2009) 452\u2013457. https:\/\/doi.org\/10.1002\/rcs.","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"998_CR32","doi-asserted-by":"publisher","first-page":"2930","DOI":"10.1007\/s00330-021-08441-4","volume":"32","author":"SJ Bette","year":"2022","unstructured":"S.J. Bette, F.M. Braun, M. Haerting, J.A. Decker, J.H. Luitjens, C. Scheurig-Muenkler, T.J. Kroencke, F. Schwarz, Visualization of bone details in a novel photon-counting dual-source CT scanner\u2014comparison with energy-integrating CT, Eur. Radiol. 32 (2022) 2930\u20132936. https:\/\/doi.org\/10.1007\/s00330-021-08441-4.","journal-title":"Eur. Radiol."},{"key":"998_CR33","doi-asserted-by":"publisher","unstructured":"E.J. Smith, J.A. Anstey, G. Venne, R.E. Ellis, Using additive manufacturing in accuracy evaluation of reconstructions from computed tomography, Proc. Inst. Mech. Eng. Part H J. Eng. Med. 227 (2013) 551\u2013559. https:\/\/doi.org\/10.1177\/0954411912474612.","DOI":"10.1177\/0954411912474612"},{"key":"998_CR34","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.hcl.2012.02.001","volume":"28","author":"KW Nellans","year":"2012","unstructured":"K.W. Nellans, E. Kowalski, K.C. Chung, The Epidemiology of Distal Radius Fractures. Hand Clin. 28 (2012) 113\u2013125. https:\/\/doi.org\/10.1016\/j.hcl.2012.02.001.","journal-title":"Hand Clin"},{"key":"998_CR35","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1002\/jor.21268","volume":"29","author":"SF Baumbach","year":"2011","unstructured":"S.F. Baumbach, R. Schmidt, P. Varga, T. Heinz, V. V\u00e9csei, P.K. Zysset, Where is the distal fracture line location of dorsally displaced distal radius fractures?, J. Orthop. Res. 29 (2011) 489\u2013494. https:\/\/doi.org\/10.1002\/jor.21268.","journal-title":"J. Orthop. Res."},{"key":"998_CR36","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1148\/radiology.219.1.r01ap1311","volume":"219","author":"CA Goldfarb","year":"2001","unstructured":"C.A. Goldfarb, Y. Yin, L.A. Gilula, A.J. Fisher, M.I. Boyer, Wrist fractures: What the clinician wants to know, Radiology. 219 (2001) 11\u201328. https:\/\/doi.org\/10.1148\/radiology.219.1.r01ap1311.","journal-title":"Radiology."},{"key":"998_CR37","doi-asserted-by":"publisher","unstructured":"D.J. Bozentka, P.K. Beredjiklian, D. Westawski, D.R. Steinberg, Digital radiographs in the assessment of distal radius fracture parameters, Clin. Orthop. Relat. Res. (2002) 409\u2013413. https:\/\/doi.org\/10.1097\/00003086-200204000-00048.","DOI":"10.1097\/00003086-200204000-00048"},{"key":"998_CR38","doi-asserted-by":"publisher","unstructured":"R.J. Medoff, Essential radiographic evaluation for distal radius fractures, First Edit, Elsevier Inc., 2009. https:\/\/doi.org\/10.1016\/b978-1-4160-5646-1.00006-0.","DOI":"10.1016\/b978-1-4160-5646-1.00006-0"},{"key":"998_CR39","doi-asserted-by":"publisher","first-page":"204800401664546","DOI":"10.1177\/2048004016645467","volume":"5","author":"N Byrne","year":"2016","unstructured":"N. Byrne, M. Velasco Forte, A. Tandon, I. Valverde, T. Hussain, A systematic review of image segmentation methodology, used in the additive manufacture of patient-specific 3D printed models of the cardiovascular system, JRSM Cardiovasc. Dis. 5 (2016) 204800401664546. https:\/\/doi.org\/10.1177\/2048004016645467.","journal-title":"JRSM Cardiovasc. Dis."},{"key":"998_CR40","first-page":"9","volume":"7","author":"TN Hangartner","year":"2007","unstructured":"T.N. Hangartner, Thresholding technique for accurate analysis of density and geometry in QCT, pQCT and \u00ccCT images, J. Musculoskelet. Neuronal Interact. 7 (2007) 9\u201316.","journal-title":"J. Musculoskelet. Neuronal Interact."},{"key":"998_CR41","doi-asserted-by":"publisher","unstructured":"P. Virtanen, R. Gommers, T.E. Oliphant, M. Haberland, T. Reddy, D. Cournapeau, E. Burovski, P. Peterson, W. Weckesser, J. Bright, S.J. van der Walt, M. Brett, J. Wilson, K.J. Millman, N. Mayorov, A.R.J. Nelson, E. Jones, R. Kern, E. Larson, C.J. Carey, \u0130. Polat, Y. Feng, E.W. Moore, J. VanderPlas, D. Laxalde, J. Perktold, R. Cimrman, I. Henriksen, E.A. Quintero, C.R. Harris, A.M. Archibald, A.H. Ribeiro, F. Pedregosa, P. van Mulbregt, A. Vijaykumar, A. Pietro Bardelli, A. Rothberg, A. Hilboll, A. Kloeckner, A. Scopatz, A. Lee, A. Rokem, C.N. Woods, C. Fulton, C. Masson, C. H\u00e4ggstr\u00f6m, C. Fitzgerald, D.A. Nicholson, D.R. Hagen, D. V. Pasechnik, E. Olivetti, E. Martin, E. Wieser, F. Silva, F. Lenders, F. Wilhelm, G. Young, G.A. Price, G.L. Ingold, G.E. Allen, G.R. Lee, H. Audren, I. Probst, J.P. Dietrich, J. Silterra, J.T. Webber, J. Slavi\u010d, J. Nothman, J. Buchner, J. Kulick, J.L. Sch\u00f6nberger, J.V. de Miranda Cardoso, J. Reimer, J. Harrington, J.L.C. Rodr\u00edguez, J. Nunez-Iglesias, J. Kuczynski, K. Tritz, M. Thoma, M. Newville, M. K\u00fcmmerer, M. Bolingbroke, M. Tartre, M. Pak, N.J. Smith, N. Nowaczyk, N. Shebanov, O. Pavlyk, P.A. Brodtkorb, P. Lee, R.T. McGibbon, R. Feldbauer, S. Lewis, S. Tygier, S. Sievert, S. Vigna, S. Peterson, S. More, T. Pudlik, T. Oshima, T.J. Pingel, T.P. Robitaille, T. Spura, T.R. Jones, T. Cera, T. Leslie, T. Zito, T. Krauss, U. Upadhyay, Y.O. Halchenko, Y. V\u00e1zquez-Baeza, SciPy 1.0: fundamental algorithms for scientific computing in Python, Nat. Methods. 17 (2020) 261\u2013272. https:\/\/doi.org\/10.1038\/s41592-019-0686-2.","DOI":"10.1038\/s41592-019-0686-2"},{"key":"998_CR42","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"T.K. Koo, M.Y. Li, A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research, J. Chiropr. Med. 15 (2016) 155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012.","journal-title":"J. Chiropr. Med."},{"key":"998_CR43","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1016\/j.medengphy.2014.03.016","volume":"36","author":"J Van den Broeck","year":"2014","unstructured":"J. Van den Broeck, E. Vereecke, R. Wirix-Speetjens, J. Vander Sloten, Segmentation accuracy of long bones, Med. Eng. Phys. 36 (2014) 949\u2013953. https:\/\/doi.org\/10.1016\/j.medengphy.2014.03.016.","journal-title":"Med. Eng. Phys."},{"key":"998_CR44","doi-asserted-by":"publisher","unstructured":"L. Li, C. Wang, X. Li, G. Fu, D. Chen, Y. Huang, Research on the dimensional accuracy of customized bone augmentation combined with 3D -printing individualized titanium mesh: A retrospective case series study, Clin. Implant Dent. Relat. Res. 23 (2020). https:\/\/doi.org\/10.1111\/cid.12966.","DOI":"10.1111\/cid.12966"},{"key":"998_CR45","doi-asserted-by":"publisher","first-page":"2293","DOI":"10.21037\/gs-21-264","volume":"10","author":"MP Chae","year":"2021","unstructured":"M.P. Chae, R.D. Chung, J.A. Smith, D.J. Hunter-Smith, W.M. Rozen, The accuracy of clinical 3D printing in reconstructive surgery: literature review and in vivo validation study, Gland Surg. 10 (2021) 2293\u20132303. https:\/\/doi.org\/10.21037\/gs-21-264.","journal-title":"Gland Surg"},{"key":"998_CR46","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.medengphy.2011.07.027","volume":"34","author":"K Rathnayaka","year":"2012","unstructured":"K. Rathnayaka, K.I. Momot, H. Noser, A. Volp, M.A. Schuetz, T. Sahama, B. Schmutz, Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D models, Med. Eng. Phys. 34 (2012) 357\u2013363. https:\/\/doi.org\/10.1016\/j.medengphy.2011.07.027.","journal-title":"Eng. Phys."},{"key":"998_CR47","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.joms.2005.03.016","volume":"63","author":"J Winder","year":"2005","unstructured":"J. Winder, R. Bibb, Medical Rapid Prototyping Technologies: State of the Art and Current Limitations for Application in Oral and Maxillofacial Surgery, J. Oral Maxillofac. Surg. 63 (2005) 1006\u20131015. https:\/\/doi.org\/10.1016\/j.joms.2005.03.016.","journal-title":"J. Oral Maxillofac. Surg."},{"key":"998_CR48","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1016\/j.media.2010.01.003","volume":"14","author":"GM Treece","year":"2010","unstructured":"G.M. Treece, A.H. Gee, P.M. Mayhew, K.E.S. Poole, High resolution cortical bone thickness measurement from clinical CT data, Med. Image Anal. 14 (2010) 276\u2013290. https:\/\/doi.org\/10.1016\/j.media.2010.01.003.","journal-title":"Image Anal."},{"key":"998_CR49","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1016\/j.medengphy.2015.04.010","volume":"37","author":"EA Lalone","year":"2015","unstructured":"E.A. Lalone, R.T. Willing, H.L. Shannon, G.J.W. King, J.A. Johnson, Accuracy assessment of 3D bone reconstructions using CT: An intro comparison, Med. Eng. Phys. 37 (2015) 729\u2013738. https:\/\/doi.org\/10.1016\/j.medengphy.2015.04.010.","journal-title":"Med. Eng. Phys."}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-024-00998-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-024-00998-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-024-00998-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T17:20:30Z","timestamp":1722878430000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-024-00998-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,14]]},"references-count":49,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,8]]}},"alternative-id":["998"],"URL":"https:\/\/doi.org\/10.1007\/s10278-024-00998-y","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,14]]},"assertion":[{"value":"25 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 December 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 December 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Anatomic forearm specimens were provided by the Center for Anatomy and Cell Biology, Medical University of Vienna (approved by the Ethics Committee of the Medical University of Vienna (EK-Nr: 2003\/2019)).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}]}}