{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T22:45:16Z","timestamp":1778193916817,"version":"3.51.4"},"reference-count":83,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T00:00:00Z","timestamp":1750809600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T00:00:00Z","timestamp":1750809600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The objective of this study is to investigate the impact of deep learning reconstruction and accelerated acquisition on reproducibility and variability of radiomic features in abdominal MRI. Seventeen volunteers were prospectively included to undergo abdominal MRI on a 3-T scanner for axial T2-weighted, axial T2-weighted fat-suppressed, and coronal T2-weighted sequences. Each sequence was scanned for four times using clinical reference acquisition with standard reconstruction, clinical reference acquisition with deep learning reconstruction, accelerated acquisition with standard reconstruction, and accelerated acquisition with deep learning reconstruction, respectively. The regions of interest were drawn for ten anatomical sites with rigid registrations. Ninety-three radiomic features were extracted via PyRadiomics after\n                    <jats:italic>z<\/jats:italic>\n                    -score normalization. The reproducibility was evaluated using clinical reference acquisition with standard reconstruction as reference by intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). The variability among four scans was assessed by coefficient of variation (CV) and quartile coefficient of dispersion (QCD). Our study found that the median (first and third\u00a0quartile) of overall ICC and CCC values were 0.451 (0.305, 0.583) and 0.450 (0.304, 0.582). The overall percentage of radiomic features with ICC\u2009&gt;\u20090.90 and CCC\u2009&gt;\u20090.90 was 8.1% and 8.1%, and was considered acceptable. The median (first and third\u00a0quartile) of overall CV and QCD values was 9.4% (4.9%, 17.2%) and 4.9% (2.5%, 9.7%). The overall percentage of radiomic features with CV\u2009&lt;\u200910% and QCD\u2009&lt;\u200910% was 51.9% and 75.0%, and was considered acceptable. Without respect to clinical significance, deep learning reconstruction and accelerated acquisition led to a poor reproducibility of radiomic features, but more than a half of the radiomic features varied within an acceptable range.\n                  <\/jats:p>","DOI":"10.1007\/s10278-025-01503-9","type":"journal-article","created":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T14:32:14Z","timestamp":1750861934000},"page":"1181-1194","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Assessment of Robustness of MRI Radiomic Features in the Abdomen: Impact of Deep Learning Reconstruction and Accelerated Acquisition"],"prefix":"10.1007","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9817-2294","authenticated-orcid":false,"given":"Jingyu","family":"Zhong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yue","family":"Xing","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yangfan","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xianwei","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shun","family":"Dai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Defang","family":"Ding","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junjie","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiarui","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7426-4496","authenticated-orcid":false,"given":"Yang","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minda","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominik","family":"Nickel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjie","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6612-8520","authenticated-orcid":false,"given":"Weiwu","family":"Yao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,6,25]]},"reference":[{"issue":"5","key":"1503_CR1","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1002\/jmri.20293","volume":"21","author":"C Klessen","year":"2005","unstructured":"Klessen C, Asbach P, Kroencke TJ et al (2005) Magnetic resonance imaging of the upper abdomen using a free-breathing T2-weighted turbo spin echo sequence with navigator triggered prospective acquisition correction. J Magn Reson Imaging 21(5):576\u2013582. https:\/\/doi.org\/10.1002\/jmri.20293","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"1503_CR2","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1002\/jmri.21002","volume":"26","author":"SS Lee","year":"2007","unstructured":"Lee SS, Byun JH, Hong HS et al (2007) Image quality and focal lesion detection on T2-weighted MR imaging of the liver: comparison of two high-resolution free-breathing imaging techniques with two breath-hold imaging techniques. J Magn Reson Imaging 26(2):323\u2013330. https:\/\/doi.org\/10.1002\/jmri.21002","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"1503_CR3","doi-asserted-by":"publisher","first-page":"934","DOI":"10.1002\/mrm.24727","volume":"71","author":"EK Brodsky","year":"2014","unstructured":"Brodsky EK, Bultman EM, Johnson KM et al (2014) High-spatial and high-temporal resolution dynamic contrast-enhanced perfusion imaging of the liver with time-resolved three-dimensional radial MRI. Magn Reson Med 71(3):934\u2013941. https:\/\/doi.org\/10.1002\/mrm.24727","journal-title":"Magn Reson Med"},{"issue":"4","key":"1503_CR4","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1001\/jamaoncol.2016.3147","volume":"3","author":"SY Kim","year":"2017","unstructured":"Kim SY, An J, Lim YS et al (2017) MRI with liver-specific contrast for surveillance of patients with cirrhosis at high risk of hepatocellular carcinoma. JAMA Oncol 3(4):456\u2013463. https:\/\/doi.org\/10.1001\/jamaoncol.2016.3147","journal-title":"JAMA Oncol"},{"issue":"3","key":"1503_CR5","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1148\/rg.2019180123","volume":"39","author":"R Canellas","year":"2019","unstructured":"Canellas R, Rosenkrantz AB, Taouli B et al (2019) Abbreviated MRI protocols for the abdomen. Radiographics 39(3):744\u2013758. https:\/\/doi.org\/10.1148\/rg.2019180123","journal-title":"Radiographics"},{"issue":"1","key":"1503_CR6","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1002\/jmri.28764","volume":"59","author":"KI Ringe","year":"2024","unstructured":"Ringe KI, Wang J, Deng Y et al (2024) Abbreviated MRI protocols in the abdomen and pelvis. J Magn Reson Imaging 59(1):58\u201369. https:\/\/doi.org\/10.1002\/jmri.28764","journal-title":"J Magn Reson Imaging"},{"issue":"2","key":"1503_CR7","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1002\/jmri.21855","volume":"30","author":"S Nanko","year":"2009","unstructured":"Nanko S, Oshima H, Watanabe T, Sasaki S, Hara M, Shibamoto Y (2009) Usefulness of the application of the BLADE technique to reduce motion artifacts on navigation-triggered prospective acquisition correction (PACE) T2-weighted MRI (T2WI) of the liver. J Magn Reson Imaging 30(2):321\u2013216. https:\/\/doi.org\/10.1002\/jmri.21855","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"1503_CR8","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1148\/radiol.14140386","volume":"274","author":"MR Bashir","year":"2015","unstructured":"Bashir MR, Castelli P, Davenport MS et al (2015) Respiratory motion artifact affecting hepatic arterial phase MR imaging with gadoxetate disodium is more common in patients with a prior episode of arterial phase motion associated with gadoxetate disodium. Radiology 274(1):141\u2013148. https:\/\/doi.org\/10.1148\/radiol.14140386","journal-title":"Radiology"},{"issue":"6","key":"1503_CR9","doi-asserted-by":"publisher","first-page":"2821","DOI":"10.1007\/s00330-018-5897-x","volume":"29","author":"YS Park","year":"2019","unstructured":"Park YS, Lee J, Kim JW, Park CM, Lee CH (2019) Second shot arterial phase to overcome degraded hepatic arterial phase in liver MR imaging. Eur Radiol 29(6):2821\u20132829. https:\/\/doi.org\/10.1007\/s00330-018-5897-x","journal-title":"Eur Radiol"},{"issue":"1","key":"1503_CR10","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1097\/00004728-200101000-00010","volume":"25","author":"Y Nakayama","year":"2001","unstructured":"Nakayama Y, Yamashita Y, Matsuno Y et al (2001) Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: comparison with high resolution turbo spin echo sequence. J Comput Assist Tomogr 25(1):55\u201360. https:\/\/doi.org\/10.1097\/00004728-200101000-00010","journal-title":"J Comput Assist Tomogr"},{"issue":"1","key":"1503_CR11","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/s002619910019","volume":"25","author":"MG Lee","year":"2000","unstructured":"Lee MG, Jeong YK, Kim JC et al (2000) Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences. Abdom Imaging 25(1):93\u201399. https:\/\/doi.org\/10.1007\/s002619910019","journal-title":"Abdom Imaging"},{"issue":"2","key":"1503_CR12","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1109\/TMI.2017.2760978","volume":"37","author":"J Schlemper","year":"2018","unstructured":"Schlemper J, Caballero J, Hajnal JV, Price AN, Rueckert D (2018) A deep cascade of convolutional neural networks for dynamic MR image reconstruction. IEEE Trans Med Imaging 37(2):491\u2013503. https:\/\/doi.org\/10.1109\/TMI.2017.2760978","journal-title":"IEEE Trans Med Imaging"},{"issue":"6","key":"1503_CR13","doi-asserted-by":"publisher","first-page":"3055","DOI":"10.1002\/mrm.26977","volume":"79","author":"K Hammernik","year":"2018","unstructured":"Hammernik K, Klatzer T, Kobler E et al (2018) Learning a variational network for reconstruction of accelerated MRI data. Magn Reson Med 79(6):3055\u20133071. https:\/\/doi.org\/10.1002\/mrm.26977","journal-title":"Magn Reson Med"},{"issue":"5","key":"1503_CR14","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1097\/RLI.0000000000000743","volume":"56","author":"J Herrmann","year":"2021","unstructured":"Herrmann J, Gassenmaier S, Nickel D et al (2021) Diagnostic confidence and feasibility of a deep learning accelerated HASTE sequence of the abdomen in a single breath-hold. Invest Radiol 56(5):313\u2013319. https:\/\/doi.org\/10.1097\/RLI.0000000000000743","journal-title":"Invest Radiol"},{"issue":"10","key":"1503_CR15","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1097\/RLI.0000000000000785","volume":"56","author":"J Herrmann","year":"2021","unstructured":"Herrmann J, Nickel D, Mugler JP 3rd et al (2021) Development and evaluation of deep learning-accelerated single-breath-hold abdominal HASTE at 3 T using variable refocusing flip angles. Invest Radiol 56(10):645\u2013652. https:\/\/doi.org\/10.1097\/RLI.0000000000000785","journal-title":"Invest Radiol"},{"key":"1503_CR16","doi-asserted-by":"publisher","unstructured":"Herrmann J, Wessling D, Nickel D et al (2023) Comprehensive clinical evaluation of a deep learning-accelerated, single-breath-hold abdominal HASTE at 1.5 T and 3 T. Acad Radiol 30(1):93\u2013102. https:\/\/doi.org\/10.1016\/j.acra.2022.03.018","DOI":"10.1016\/j.acra.2022.03.018"},{"issue":"11","key":"1503_CR17","doi-asserted-by":"publisher","first-page":"8447","DOI":"10.1007\/s00330-021-08008-3","volume":"31","author":"K Shanbhogue","year":"2021","unstructured":"Shanbhogue K, Tong A, Smereka P et al (2021) Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning-based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence. Eur Radiol 31(11):8447\u20138457. https:\/\/doi.org\/10.1007\/s00330-021-08008-3","journal-title":"Eur Radiol"},{"issue":"10","key":"1503_CR18","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.diii.2022.05.001","volume":"103","author":"S Mul\u00e9","year":"2022","unstructured":"Mul\u00e9 S, Kharrat R, Zerbib P et al (2022) Fast T2-weighted liver MRI: Image quality and solid focal lesions conspicuity using a deep learning accelerated single breath-hold HASTE fat-suppressed sequence. Diagn Interv Imaging 103(10):479\u2013485. https:\/\/doi.org\/10.1016\/j.diii.2022.05.001","journal-title":"Diagn Interv Imaging"},{"key":"1503_CR19","doi-asserted-by":"publisher","first-page":"110588","DOI":"10.1016\/j.ejrad.2022.110588","volume":"157","author":"S Han","year":"2022","unstructured":"Han S, Lee JM, Kim SW et al (2022) Evaluation of HASTE T2 weighted image with reduced echo time for detecting focal liver lesions in patients at risk of developing hepatocellular carcinoma. Eur J Radiol 157:110588. https:\/\/doi.org\/10.1016\/j.ejrad.2022.110588","journal-title":"Eur J Radiol"},{"issue":"6","key":"1503_CR20","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1097\/RLI.0000000000000943","volume":"58","author":"F Ichinohe","year":"2023","unstructured":"Ichinohe F, Oyama K, Yamada A et al (2023) Usefulness of breath-hold fat-suppressed T2-weighted images with deep learning-based reconstruction of the liver: comparison to conventional free-breathing turbo spin echo. Invest Radiol 58(6):373\u2013379. https:\/\/doi.org\/10.1097\/RLI.0000000000000943","journal-title":"Invest Radiol"},{"issue":"10","key":"1503_CR21","doi-asserted-by":"publisher","first-page":"6817","DOI":"10.1007\/s00330-023-09693-y","volume":"33","author":"P Wary","year":"2023","unstructured":"Wary P, Hossu G, Ambarki K et al (2023) Deep learning HASTE sequence compared with T2-weighted BLADE sequence for liver MRI at 3 Tesla: a qualitative and quantitative prospective study. Eur Radiol 33(10):6817\u20136827. https:\/\/doi.org\/10.1007\/s00330-023-09693-y","journal-title":"Eur Radiol"},{"issue":"1","key":"1503_CR22","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1007\/s00261-022-03687-y","volume":"48","author":"LA Ginocchio","year":"2023","unstructured":"Ginocchio LA, Smereka PN, Tong A et al (2023) Accelerated T2-weighted MRI of the liver at 3 T using a single-shot technique with deep learning-based image reconstruction: impact on the image quality and lesion detection. Abdom Radiol (NY) 48(1):282\u2013290. https:\/\/doi.org\/10.1007\/s00261-022-03687-y","journal-title":"Abdom Radiol (NY)"},{"issue":"4","key":"1503_CR23","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.ejca.2011.11.036","volume":"48","author":"P Lambin","year":"2012","unstructured":"Lambin P, Rios-Velazquez E, Leijenaar R et al (2012) Radiomics: extracting more information from medical images using advanced feature analysis. Eur J Cancer 48(4):441\u2013446. https:\/\/doi.org\/10.1016\/j.ejca.2011.11.036","journal-title":"Eur J Cancer"},{"issue":"2","key":"1503_CR24","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1148\/radiol.2015151169","volume":"278","author":"RJ Gillies","year":"2016","unstructured":"Gillies RJ, Kinahan PE, Hricak H (2016) Radiomics: images are more than pictures, they are data. Radiology 278(2):563\u2013577. https:\/\/doi.org\/10.1148\/radiol.2015151169","journal-title":"Radiology"},{"issue":"12","key":"1503_CR25","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1038\/nrclinonc.2017.141","volume":"14","author":"P Lambin","year":"2017","unstructured":"Lambin P, Leijenaar RTH, Deist TM et al (2017) Radiomics: the bridge between medical imaging and personalized medicine. Nat Rev Clin Oncol 14(12):749\u2013762. https:\/\/doi.org\/10.1038\/nrclinonc.2017.141","journal-title":"Nat Rev Clin Oncol"},{"issue":"2","key":"1503_CR26","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1038\/s41571-022-00707-0","volume":"20","author":"EP Huang","year":"2023","unstructured":"Huang EP, O\u2019Connor JPB, McShane LM et al (2023) Criteria for the translation of radiomics into clinically useful tests. Nat Rev Clin Oncol 20(2):69\u201382. https:\/\/doi.org\/10.1038\/s41571-022-00707-0","journal-title":"Nat Rev Clin Oncol"},{"issue":"10","key":"1503_CR27","doi-asserted-by":"publisher","first-page":"6736","DOI":"10.1007\/s00330-023-09645-6","volume":"33","author":"S Volpe","year":"2023","unstructured":"Volpe S, Mastroleo F, Krengli M, Jereczek-Fossa BA (2023) Quo vadis radiomics? Bibliometric analysis of 10-year Radiomics journey. Eur Radiol 33(10):6736\u20136745. https:\/\/doi.org\/10.1007\/s00330-023-09645-6","journal-title":"Eur Radiol"},{"issue":"11","key":"1503_CR28","doi-asserted-by":"publisher","first-page":"7542","DOI":"10.1007\/s00330-023-09772-0","volume":"33","author":"B Kocak","year":"2023","unstructured":"Kocak B, Baessler B, Cuocolo R, Mercaldo N, Pinto Dos Santos D (2023) Trends and statistics of artificial intelligence and radiomics research in radiology, nuclear medicine, and medical imaging: bibliometric analysis. Eur Radiol 33(11):7542\u20137555. https:\/\/doi.org\/10.1007\/s00330-023-09772-0","journal-title":"Eur Radiol"},{"issue":"1","key":"1503_CR29","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1186\/s13244-023-01437-2","volume":"14","author":"J Zhong","year":"2023","unstructured":"Zhong J, Lu J, Zhang G et al (2023) An overview of meta-analyses on radiomics: more evidence is needed to support clinical translation. Insights Imaging 14(1):111. https:\/\/doi.org\/10.1186\/s13244-023-01437-2","journal-title":"Insights Imaging"},{"issue":"11","key":"1503_CR30","doi-asserted-by":"publisher","first-page":"7556","DOI":"10.1007\/s00330-023-09768-w","volume":"33","author":"B Kocak","year":"2023","unstructured":"Kocak B, Chepelev LL, Chu LC et al (2023) Assessment of RadiomIcS rEsearch (ARISE): a brief guide for authors, reviewers, and readers from the Scientific Editorial Board of European Radiology. Eur Radiol 33(11):7556\u20137560. https:\/\/doi.org\/10.1007\/s00330-023-09768-w","journal-title":"Eur Radiol"},{"issue":"1","key":"1503_CR31","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1186\/s13244-023-01415-8","volume":"14","author":"B Kocak","year":"2023","unstructured":"Kocak B, Baessler B, Bakas S et al (2023) CheckList for EvaluAtion of Radiomics research (CLEAR): a step-by-step reporting guideline for authors and reviewers endorsed by ESR and EuSoMII. Insights Imaging 14(1):75. https:\/\/doi.org\/10.1186\/s13244-023-01415-8","journal-title":"Insights Imaging"},{"issue":"1","key":"1503_CR32","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s13244-023-01572-w","volume":"15","author":"B Kocak","year":"2024","unstructured":"Kocak B, Akinci D\u2019Antonoli T, Mercaldo N et al (2024) METhodological RadiomICs Score (METRICS): a quality scoring tool for radiomics research endorsed by EuSoMII. Insights Imaging 15(1):8. https:\/\/doi.org\/10.1186\/s13244-023-01572-w","journal-title":"Insights Imaging"},{"issue":"1","key":"1503_CR33","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1007\/s00330-023-10095-3","volume":"34","author":"T Akinci D\u2019Antonoli","year":"2024","unstructured":"Akinci D\u2019Antonoli T, Cuocolo R, Baessler B, Pinto Dos Santos D (2024) Towards reproducible radiomics research: introduction of a database for radiomics studies. Eur Radiol 34(1):436\u2013443. https:\/\/doi.org\/10.1007\/s00330-023-10095-3","journal-title":"Eur Radiol"},{"issue":"2","key":"1503_CR34","doi-asserted-by":"publisher","first-page":"189","DOI":"10.2967\/jnumed.117.200501","volume":"59","author":"M Valli\u00e8res","year":"2018","unstructured":"Valli\u00e8res M, Zwanenburg A, Badic B, Cheze Le Rest C, Visvikis D, Hatt M (2018) Responsible radiomics research for faster clinical translation. J Nucl Med 59(2):189\u2013193. https:\/\/doi.org\/10.2967\/jnumed.117.200501","journal-title":"J Nucl Med"},{"issue":"7","key":"1503_CR35","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.3348\/kjr.2018.0070","volume":"20","author":"JE Park","year":"2019","unstructured":"Park JE, Park SY, Kim HJ, Kim HS (2019) Reproducibility and generalizability in radiomics modeling: possible strategies in radiologic and statistical perspectives. Korean J Radiol 20(7):1124\u20131137. https:\/\/doi.org\/10.3348\/kjr.2018.0070","journal-title":"Korean J Radiol"},{"issue":"13","key":"1503_CR36","doi-asserted-by":"publisher","first-page":"2638","DOI":"10.1007\/s00259-019-04391-8","volume":"46","author":"A Zwanenburg","year":"2019","unstructured":"Zwanenburg A (2019) Radiomics in nuclear medicine: robustness, reproducibility, standardization, and how to avoid data analysis traps and replication crisis. Eur J Nucl Med Mol Imaging 46(13):2638\u20132655. https:\/\/doi.org\/10.1007\/s00259-019-04391-8","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"1503_CR37","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.phro.2021.10.007","volume":"20","author":"E Pfaehler","year":"2021","unstructured":"Pfaehler E, Zhovannik I, Wei L et al (2021) A systematic review and quality of reporting checklist for repeatability and reproducibility of radiomic features. Phys Imaging Radiat Oncol 20:69\u201375. https:\/\/doi.org\/10.1016\/j.phro.2021.10.007","journal-title":"Phys Imaging Radiat Oncol"},{"issue":"5","key":"1503_CR38","doi-asserted-by":"publisher","first-page":"2706","DOI":"10.1007\/s00330-020-07370-y","volume":"31","author":"D Alis","year":"2021","unstructured":"Alis D, Yergin M, Asmakutlu O, Topel C, Karaarslan E (2021) The influence of cardiac motion on radiomics features: radiomics features of non-enhanced CMR cine images greatly vary through the cardiac cycle. Eur Radiol 31(5):2706\u20132715. https:\/\/doi.org\/10.1007\/s00330-020-07370-y","journal-title":"Eur Radiol"},{"issue":"2","key":"1503_CR39","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1002\/jmri.27558","volume":"54","author":"A Cromb\u00e9","year":"2021","unstructured":"Cromb\u00e9 A, Buy X, Han F, Toupin S, Kind M (2021) Assessment of repeatability, reproducibility, and performances of T2 mapping-based radiomics features: a comparative study. J Magn Reson Imaging 54(2):537\u2013548. https:\/\/doi.org\/10.1002\/jmri.27558","journal-title":"J Magn Reson Imaging"},{"issue":"9","key":"1503_CR40","doi-asserted-by":"publisher","first-page":"6457","DOI":"10.1007\/s00330-021-07760-w","volume":"31","author":"M Kim","year":"2021","unstructured":"Kim M, Jung SC, Park JE, Park SY, Lee H, Choi KM (2021) Reproducibility of radiomic features in SENSE and compressed SENSE: impact of acceleration factors. Eur Radiol 31(9):6457\u20136470. https:\/\/doi.org\/10.1007\/s00330-021-07760-w","journal-title":"Eur Radiol"},{"issue":"3","key":"1503_CR41","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1002\/jmri.27581","volume":"54","author":"J Jang","year":"2021","unstructured":"Jang J, El-Rewaidy H, Ngo LH et al (2021) Sensitivity of myocardial radiomic features to imaging parameters in cardiac mr imaging. J Magn Reson Imaging 54(3):787\u2013794. https:\/\/doi.org\/10.1002\/jmri.27581","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"1503_CR42","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1002\/jmri.27635","volume":"54","author":"B Eck","year":"2021","unstructured":"Eck B, Chirra PV, Muchhala A et al (2021) Prospective evaluation of repeatability and robustness of radiomic descriptors in healthy brain tissue regions in vivo across systematic variations in T2-weighted magnetic resonance imaging acquisition parameters. J Magn Reson Imaging 54(3):1009\u20131021. https:\/\/doi.org\/10.1002\/jmri.27635","journal-title":"J Magn Reson Imaging"},{"issue":"9","key":"1503_CR43","doi-asserted-by":"publisher","first-page":"1573","DOI":"10.3390\/diagnostics11091573","volume":"11","author":"NSM Haniff","year":"2021","unstructured":"Haniff NSM, Abdul Karim MK et al (2021) Stability and reproducibility of radiomic features based various segmentation technique on MR images of hepatocellular carcinoma (HCC). Diagnostics (Basel) 11(9):1573. https:\/\/doi.org\/10.3390\/diagnostics11091573","journal-title":"Diagnostics (Basel)"},{"issue":"2","key":"1503_CR44","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1002\/jmri.28027","volume":"56","author":"RWY Granzier","year":"2022","unstructured":"Granzier RWY, Ibrahim A, Primakov S et al (2022) Test-retest data for the assessment of breast MRI radiomic feature repeatability. J Magn Reson Imaging 56(2):592\u2013604. https:\/\/doi.org\/10.1002\/jmri.28027","journal-title":"J Magn Reson Imaging"},{"issue":"7","key":"1503_CR45","doi-asserted-by":"publisher","first-page":"4791","DOI":"10.1007\/s00330-022-08555-3","volume":"32","author":"S Fujita","year":"2022","unstructured":"Fujita S, Hagiwara A, Yasaka K et al (2022) Radiomics with 3-dimensional magnetic resonance fingerprinting: influence of dictionary design on repeatability and reproducibility of radiomic features. Eur Radiol 32(7):4791\u20134800. https:\/\/doi.org\/10.1007\/s00330-022-08555-3","journal-title":"Eur Radiol"},{"issue":"5","key":"1503_CR46","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.1002\/jmri.28191","volume":"56","author":"RN Mitchell-Hay","year":"2022","unstructured":"Mitchell-Hay RN, Ahearn TS, Murray AD, Waiter GD (2022) Investigation of the inter- and intrascanner reproducibility and repeatability of radiomics features in T1-weighted brain MRI. J Magn Reson Imaging 56(5):1559\u20131568. https:\/\/doi.org\/10.1002\/jmri.28191","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"1503_CR47","doi-asserted-by":"publisher","first-page":"2030","DOI":"10.1007\/s00330-021-08282-1","volume":"32","author":"G Carbonell","year":"2022","unstructured":"Carbonell G, Kennedy P, Bane O et al (2022) Precision of MRI radiomics features in the liver and hepatocellular carcinoma. Eur Radiol 32(3):2030\u20132040. https:\/\/doi.org\/10.1007\/s00330-021-08282-1","journal-title":"Eur Radiol"},{"issue":"6","key":"1503_CR48","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1097\/RCT.0000000000001344","volume":"46","author":"K Hu","year":"2022","unstructured":"Hu K, Deng W, Li N et al (2022) Impact of parallel acquisition technology on the robustness of magnetic resonance imaging radiomic features. J Comput Assist Tomogr 46(6):906\u2013913. https:\/\/doi.org\/10.1097\/RCT.0000000000001344","journal-title":"J Comput Assist Tomogr"},{"key":"1503_CR49","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.clinimag.2022.01.002","volume":"83","author":"V Prabhu","year":"2022","unstructured":"Prabhu V, Gillingham N, Babb JS et al (2022) Repeatability, robustness, and reproducibility of texture features on 3 Tesla liver MRI. Clin Imaging 83:177\u2013183. https:\/\/doi.org\/10.1016\/j.clinimag.2022.01.002","journal-title":"Clin Imaging"},{"issue":"4","key":"1503_CR50","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/RLI.0000000000000927","volume":"58","author":"M Wennmann","year":"2023","unstructured":"Wennmann M, Bauer F, Klein A et al (2023) In vivo repeatability and multiscanner reproducibility of MRI radiomics features in patients with monoclonal plasma cell disorders: a prospective bi-institutional study. Invest Radiol 58(4):253\u2013264. https:\/\/doi.org\/10.1097\/RLI.0000000000000927","journal-title":"Invest Radiol"},{"issue":"3","key":"1503_CR51","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1002\/jmri.28572","volume":"58","author":"K Lin","year":"2023","unstructured":"Lin K, Sarnari R, Carr JC, Markl M (2023) Cine MRI-derived radiomics features of the cardiac blood pool: periodicity, specificity, and reproducibility. J Magn Reson Imaging 58(3):807\u2013814. https:\/\/doi.org\/10.1002\/jmri.28572","journal-title":"J Magn Reson Imaging"},{"issue":"8","key":"1503_CR52","doi-asserted-by":"publisher","first-page":"5056","DOI":"10.1007\/s00330-023-10495-5","volume":"34","author":"M Gross","year":"2024","unstructured":"Gross M, Huber S, Arora S et al (2024) Automated MRI liver segmentation for anatomical segmentation, liver volumetry, and the extraction of radiomics. Eur Radiol 34(8):5056\u20135065. https:\/\/doi.org\/10.1007\/s00330-023-10495-5","journal-title":"Eur Radiol"},{"issue":"3","key":"1503_CR53","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1148\/radiol.2019190928","volume":"293","author":"M Meyer","year":"2019","unstructured":"Meyer M, Ronald J, Vernuccio F et al (2019) Reproducibility of CT radiomic features within the same patient: influence of radiation dose and CT reconstruction settings. Radiology 293(3):583\u2013591. https:\/\/doi.org\/10.1148\/radiol.2019190928","journal-title":"Radiology"},{"issue":"4","key":"1503_CR54","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1007\/s00261-020-02415-8","volume":"45","author":"S Javadi","year":"2020","unstructured":"Javadi S, Elsherif S, Bhosale P et al (2020) Quantitative attenuation accuracy of virtual non-enhanced imaging compared to that of true non-enhanced imaging on dual-source dual-energy CT. Abdom Radiol (NY) 45(4):1100\u20131109. https:\/\/doi.org\/10.1007\/s00261-020-02415-8","journal-title":"Abdom Radiol (NY)"},{"issue":"2","key":"1503_CR55","doi-asserted-by":"publisher","first-page":"95","DOI":"10.5152\/dir.2019.19345","volume":"26","author":"\u0130 \u00c7aml\u0131da\u011f","year":"2020","unstructured":"\u00c7aml\u0131da\u011f \u0130 (2020) Compatibility of true and virtual unenhanced attenuation in rapid kV-switching dual energy CT. Diagn Interv Radiol 26(2):95\u2013100. https:\/\/doi.org\/10.5152\/dir.2019.19345","journal-title":"Diagn Interv Radiol"},{"issue":"6","key":"1503_CR56","doi-asserted-by":"publisher","first-page":"1000","DOI":"10.3390\/diagnostics11061000","volume":"11","author":"D Caruso","year":"2021","unstructured":"Caruso D, Zerunian M, Pucciarelli F et al (2021) Influence of adaptive statistical iterative reconstructions on CT radiomic features in oncologic patients. Diagnostics (Basel) 11(6):1000. https:\/\/doi.org\/10.3390\/diagnostics11061000","journal-title":"Diagnostics (Basel)"},{"issue":"3","key":"1503_CR57","doi-asserted-by":"publisher","first-page":"1959","DOI":"10.1007\/s00330-021-08249-2","volume":"32","author":"S Lennartz","year":"2022","unstructured":"Lennartz S, O\u2019Shea A, Parakh A, Persigehl T, Baessler B, Kambadakone A (2022) Robustness of dual-energy CT-derived radiomic features across three different scanner types. Eur Radiol 32(3):1959\u20131970. https:\/\/doi.org\/10.1007\/s00330-021-08249-2","journal-title":"Eur Radiol"},{"issue":"21","key":"1503_CR58","doi-asserted-by":"publisher","first-page":"e104","DOI":"10.1158\/0008-5472.CAN-17-0339","volume":"77","author":"JJM van Griethuysen","year":"2017","unstructured":"van Griethuysen JJM, Fedorov A, Parmar C et al (2017) Computational radiomics system to decode the radiographic phenotype. Cancer Res 77(21):e104\u2013e107. https:\/\/doi.org\/10.1158\/0008-5472.CAN-17-0339","journal-title":"Cancer Res"},{"issue":"2","key":"1503_CR59","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1148\/radiol.2020191145","volume":"295","author":"A Zwanenburg","year":"2020","unstructured":"Zwanenburg A, Valli\u00e8res M, Abdalah MA et al (2020) The image biomarker standardization initiative: standardized quantitative radiomics for high-throughput image-based phenotyping. Radiology 295(2):328\u2013338. https:\/\/doi.org\/10.1148\/radiol.2020191145","journal-title":"Radiology"},{"issue":"2","key":"1503_CR60","doi-asserted-by":"publisher","first-page":"e231319","DOI":"10.1148\/radiol.231319","volume":"310","author":"P Whybra","year":"2024","unstructured":"Whybra P, Zwanenburg A, Andrearczyk V et al (2024) The image biomarker standardization initiative: standardized convolutional filters for reproducible radiomics and enhanced clinical insights. Radiology 310(2):e231319. https:\/\/doi.org\/10.1148\/radiol.231319","journal-title":"Radiology"},{"issue":"2","key":"1503_CR61","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY (2016) A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 15(2):155\u2013163. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012","journal-title":"J Chiropr Med"},{"issue":"3","key":"1503_CR62","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.cmpb.2012.09.002","volume":"109","author":"JL Carrasco","year":"2013","unstructured":"Carrasco JL, Phillips BR, Puig-Martinez J, King TS, Chinchilli VM (2013) Estimation of the concordance correlation coefficient for repeated measures using SAS and R. Comput Methods Programs Biomed 109(3):293\u2013304. https:\/\/doi.org\/10.1016\/j.cmpb.2012.09.002","journal-title":"Comput Methods Programs Biomed"},{"issue":"6","key":"1503_CR63","doi-asserted-by":"publisher","first-page":"1235","DOI":"10.1128\/cdli.9.6.1235-1239.2002","volume":"9","author":"GF Reed","year":"2002","unstructured":"Reed GF, Lynn F (2002) Meade BD (2002) Use of coefficient of variation in assessing variability of quantitative assays. Clin Diagn Lab Immunol. 9(6):1235\u20131239. https:\/\/doi.org\/10.1128\/cdli.9.6.1235-1239.2002","journal-title":"Clin Diagn Lab Immunol."},{"issue":"11","key":"1503_CR64","doi-asserted-by":"publisher","first-page":"2953","DOI":"10.1016\/j.csda.2005.05.007","volume":"50","author":"DG Bonett","year":"2006","unstructured":"Bonett DG (2006) Confidence interval for a coefficient of quartile variation. Comput Stat Data Anal 50(11):2953\u20132957. https:\/\/doi.org\/10.1016\/j.csda.2005.05.007","journal-title":"Comput Stat Data Anal"},{"issue":"4","key":"1503_CR65","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1002\/jmri.29192","volume":"60","author":"J Zhong","year":"2024","unstructured":"Zhong J, Liu X, Hu Y et al (2024) Robustness of quantitative diffusion metrics from four models: a prospective study on the influence of scan-rescans, voxel size, coils, and observers. J Magn Reson Imaging 60(4):1470\u20131483. https:\/\/doi.org\/10.1002\/jmri.29192","journal-title":"J Magn Reson Imaging"},{"issue":"8","key":"1503_CR66","doi-asserted-by":"publisher","first-page":"5480","DOI":"10.1007\/s00330-022-08628-3","volume":"32","author":"Y Chen","year":"2022","unstructured":"Chen Y, Zhong J, Wang L et al (2022) Robustness of CT radiomics features: consistency within and between single-energy CT and dual-energy CT. Eur Radiol 32(8):5480\u20135490. https:\/\/doi.org\/10.1007\/s00330-022-08628-3","journal-title":"Eur Radiol"},{"issue":"2","key":"1503_CR67","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1007\/s00330-022-09119-1","volume":"33","author":"J Zhong","year":"2022","unstructured":"Zhong J, Xia Y, Chen Y et al (2022) Deep learning image reconstruction algorithm reduces image noise while alters radiomics features in dual-energy CT in comparison with conventional iterative reconstruction algorithms: a phantom study. Eur Radiol 33(2):812\u2013824. https:\/\/doi.org\/10.1007\/s00330-022-09119-1","journal-title":"Eur Radiol"},{"issue":"1","key":"1503_CR68","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s13244-023-01426-5","volume":"14","author":"J Zhong","year":"2023","unstructured":"Zhong J, Pan Z, Chen Y et al (2023) Robustness of radiomics features of virtual unenhanced and virtual monoenergetic images in dual-energy CT among different imaging platforms and potential role of CT number variability. Insights Imaging 14(1):79. https:\/\/doi.org\/10.1186\/s13244-023-01426-5","journal-title":"Insights Imaging"},{"issue":"1","key":"1503_CR69","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s10278-023-00901-1","volume":"37","author":"J Zhong","year":"2024","unstructured":"Zhong J, Wu Z, Wang L et al (2024) Impacts of adaptive statistical iterative reconstruction-V and deep learning image reconstruction algorithms on robustness of CT radiomics features: opportunity for minimizing radiomics variability among scans of different dose levels. J Imaging Inform Med 37(1):123\u2013133. https:\/\/doi.org\/10.1007\/s10278-023-00901-1","journal-title":"J Imaging Inform Med"},{"issue":"2","key":"1503_CR70","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1007\/s00330-024-10976-1","volume":"35","author":"L Zhu","year":"2025","unstructured":"Zhu L, Dong H, Sun J et al (2025) Robustness of radiomics among photon-counting detector CT and dual-energy CT systems: a texture phantom study. Eur Radiol 35(2):871\u2013884. https:\/\/doi.org\/10.1007\/s00330-024-10976-1","journal-title":"Eur Radiol"},{"key":"1503_CR71","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-025-11374-x","author":"H Zhang","year":"2025","unstructured":"Zhang H, Lu T, Wang L et al (2025) Robustness of radiomics within photon-counting detector CT: impact of acquisition and reconstruction factors. Eur Radiol. https:\/\/doi.org\/10.1007\/s00330-025-11374-x","journal-title":"Eur Radiol"},{"issue":"4","key":"1503_CR72","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1097\/RMR.0000000000000247","volume":"29","author":"MA Oztek","year":"2020","unstructured":"Oztek MA, Brunnquell CL, Hoff MN et al (2020) Practical considerations for radiologists in implementing a patient-friendly MRI experience. Top Magn Reson Imaging 29(4):181\u2013186. https:\/\/doi.org\/10.1097\/RMR.0000000000000247","journal-title":"Top Magn Reson Imaging"},{"issue":"6","key":"1503_CR73","doi-asserted-by":"publisher","first-page":"1202","DOI":"10.1002\/mrm.10171","volume":"47","author":"MA Griswold","year":"2002","unstructured":"Griswold MA, Jakob PM, Heidemann RM et al (2002) Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 47(6):1202\u20131210. https:\/\/doi.org\/10.1002\/mrm.10171","journal-title":"Magn Reson Med"},{"issue":"1","key":"1503_CR74","doi-asserted-by":"publisher","first-page":"4041","DOI":"10.1038\/s41598-017-04151-4","volume":"7","author":"P Brynolfsson","year":"2017","unstructured":"Brynolfsson P, Nilsson D, Torheim T et al (2017) Haralick texture features from apparent diffusion coefficient (ADC) MRI images depend on imaging and pre-processing parameters. Sci Rep 7(1):4041. https:\/\/doi.org\/10.1038\/s41598-017-04151-4","journal-title":"Sci Rep"},{"issue":"3","key":"1503_CR75","doi-asserted-by":"publisher","first-page":"e212922","DOI":"10.1148\/radiol.212922","volume":"306","author":"H Almansour","year":"2023","unstructured":"Almansour H, Herrmann J, Gassenmaier S et al (2023) Deep learning reconstruction for accelerated spine MRI: Prospective analysis of interchangeability. Radiology 306(3):e212922. https:\/\/doi.org\/10.1148\/radiol.212922","journal-title":"Radiology"},{"issue":"2","key":"1503_CR76","doi-asserted-by":"publisher","first-page":"e220425","DOI":"10.1148\/radiol.220425","volume":"307","author":"PM Johnson","year":"2023","unstructured":"Johnson PM, Lin DJ, Zbontar J et al (2023) Deep learning reconstruction enables prospectively accelerated clinical knee MRI. Radiology 307(2):e220425. https:\/\/doi.org\/10.1148\/radiol.220425","journal-title":"Radiology"},{"issue":"1","key":"1503_CR77","doi-asserted-by":"publisher","first-page":"e231405","DOI":"10.1148\/radiol.231405","volume":"310","author":"Y Xie","year":"2024","unstructured":"Xie Y, Tao H, Li X et al (2024) Prospective comparison of standard and deep learning-reconstructed turbo spin-echo MRI of the shoulder. Radiology 310(1):e231405. https:\/\/doi.org\/10.1148\/radiol.231405","journal-title":"Radiology"},{"issue":"2","key":"1503_CR78","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1148\/radiol.204097","volume":"303","author":"T Ueda","year":"2022","unstructured":"Ueda T, Ohno Y, Yamamoto K et al (2022) Deep learning reconstruction of diffusion-weighted MRI improves image quality for prostatic imaging. Radiology 303(2):373\u2013381. https:\/\/doi.org\/10.1148\/radiol.204097","journal-title":"Radiology"},{"issue":"1","key":"1503_CR79","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1148\/radiol.2020200723","volume":"298","author":"M Kim","year":"2021","unstructured":"Kim M, Kim HS, Kim HJ et al (2021) Thin-slice pituitary MRI with deep learning-based reconstruction: diagnostic performance in a postoperative setting. Radiology 298(1):114\u2013122. https:\/\/doi.org\/10.1148\/radiol.2020200723","journal-title":"Radiology"},{"issue":"12","key":"1503_CR80","doi-asserted-by":"publisher","first-page":"8656","DOI":"10.1007\/s00330-023-09918-0","volume":"33","author":"H Yoo","year":"2023","unstructured":"Yoo H, Yoo RE, Choi SH et al (2023) Deep learning-based reconstruction for acceleration of lumbar spine MRI: a prospective comparison with standard MRI. Eur Radiol 33(12):8656\u20138668. https:\/\/doi.org\/10.1007\/s00330-023-09918-0","journal-title":"Eur Radiol"},{"key":"1503_CR81","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.ejmp.2018.05.017","volume":"50","author":"F Yang","year":"2018","unstructured":"Yang F, Dogan N, Stoyanova R, Ford JC (2018) Evaluation of radiomic texture feature error due to MRI acquisition and reconstruction: a simulation study utilizing ground truth. Phys Med 50:26\u201336. https:\/\/doi.org\/10.1016\/j.ejmp.2018.05.017","journal-title":"Phys Med"},{"issue":"6","key":"1503_CR82","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1097\/RCT.0000000000001648","volume":"48","author":"H Li","year":"2024","unstructured":"Li H, Alves VV, Pednekar A et al (2024) Impact of emerging deep learning-based MR image reconstruction algorithms on abdominal MRI radiomic features. J Comput Assist Tomogr 48(6):955\u2013962. https:\/\/doi.org\/10.1097\/RCT.0000000000001648","journal-title":"J Comput Assist Tomogr"},{"issue":"6","key":"1503_CR83","doi-asserted-by":"publisher","first-page":"e220133","DOI":"10.1148\/rg.220133","volume":"43","author":"S Kiryu","year":"2023","unstructured":"Kiryu S, Akai H, Yasaka K et al (2023) Clinical impact of deep learning reconstruction in MRI. Radiographics 43(6):e220133. https:\/\/doi.org\/10.1148\/rg.220133","journal-title":"Radiographics"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01503-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01503-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01503-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T16:24:20Z","timestamp":1776875060000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01503-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,25]]},"references-count":83,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,4]]}},"alternative-id":["1503"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01503-9","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,25]]},"assertion":[{"value":"24 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional Review Board approval was obtained from Tongren Hospital, Shanghai Jiao Tong University School of Medicine (2022-029-01, 2023-018-01).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"Written informed consent from all participants was received.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}},{"value":"Dr. Jingyu Zhong acknowledges his position as a member of the Scientific Editorial Board of\n                      European Radiology, Insights into Imaging, American Journal of Roentgenology,\n                      and\n                      BMC Medical Imaging.\n                      Dr. Yang Song, Ms. Minda Lu, and Dr. Dominik Nickel are employees of Siemens Healthineers Ltd. However, they did technical support under Siemens collaboration regulation without any payment and personal concern regarding to this study. They neither had access nor control on the data acquisition and analysis. All other authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}