{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T02:54:46Z","timestamp":1784256886874,"version":"3.55.0"},"reference-count":62,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T00:00:00Z","timestamp":1746403200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T00:00:00Z","timestamp":1746403200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["JP21K15827"],"award-info":[{"award-number":["JP21K15827"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"DOI":"10.1007\/s10278-025-01508-4","type":"journal-article","created":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T14:09:05Z","timestamp":1746454145000},"page":"827-841","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Deep Learning on Misaligned Dual-Energy Chest X-ray Images Using Paired Cycle-Consistent Generative Adversarial Networks"],"prefix":"10.1007","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0975-2164","authenticated-orcid":false,"given":"Yasuyuki","family":"Ueda","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Misato","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riko","family":"Shimazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asumi","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masashi","family":"Seki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takayuki","family":"Ishida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,5]]},"reference":[{"issue":"2","key":"1508_CR1","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/RTI.0b013e318173dd38","volume":"23","author":"H MacMahon","year":"2008","unstructured":"MacMahon H, Li F, Engelmann R, Roberts R, Armato S: Dual energy subtraction and temporal subtraction chest radiography. J Thorac Imaging. 23(2):77-85, 2008. https:\/\/doi.org\/10.1097\/RTI.0b013e318173dd38","journal-title":"J Thorac Imaging."},{"issue":"2","key":"1508_CR2","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.ejrad.2009.05.059","volume":"72","author":"H MacMahon","year":"2009","unstructured":"MacMahon H, Armato SG 3rd: Temporal subtraction chest radiography. Eur J Radiol. 72(2):238-243, 2009. https:\/\/doi.org\/10.1016\/j.ejrad.2009.05.059","journal-title":"Eur J Radiol."},{"key":"1508_CR3","doi-asserted-by":"publisher","unstructured":"Kido S, Ikezoe J, Naito H, Tamura S, Kozuka T, Ito W, et al.: Single-exposure dual-energy chest images with computed radiography. Evaluation with simulated pulmonary nodules. Invest Radiol. 28(6):482\u2013487, 1993. https:\/\/doi.org\/10.1097\/00004424-199306000-00002","DOI":"10.1097\/00004424-199306000-00002"},{"key":"1508_CR4","doi-asserted-by":"publisher","unstructured":"Kamimura R, Takashima T: Clinical application of single dual-energy subtraction technique with digital storage-phosphor radiography. J Digit Imaging. 8(1)(Suppl 1):21\u201324, 1995. https:\/\/doi.org\/10.1007\/BF03168062","DOI":"10.1007\/BF03168062"},{"issue":"1","key":"1508_CR5","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1148\/rg.261055034","volume":"26","author":"JE Kuhlman","year":"2006","unstructured":"Kuhlman JE, Collins J, Brooks GN, Yandow DR, Broderick LS: Dual-energy subtraction chest radiography: What to look for beyond calcified nodules. RadioGraphics. 26(1):79-92, 2006. https:\/\/doi.org\/10.1148\/rg.261055034","journal-title":"RadioGraphics."},{"issue":"3","key":"1508_CR6","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1148\/radiol.2413051535","volume":"241","author":"HP McAdams","year":"2006","unstructured":"McAdams HP, Samei E, Dobbins J 3rd, Tourassi GD, Ravin CE: Recent advances in chest radiography. Radiology. 241(3):663-683, 2006. https:\/\/doi.org\/10.1148\/radiol.2413051535","journal-title":"Radiology."},{"issue":"3","key":"1508_CR7","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1118\/1.1645679","volume":"31","author":"RE Alvarez","year":"2004","unstructured":"Alvarez RE, Seibert JA, Thompson SK: Comparison of dual energy detector system performance. Med Phys. 31(3):556-565, 2004. https:\/\/doi.org\/10.1118\/1.1645679","journal-title":"Med Phys."},{"issue":"2","key":"1508_CR8","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1016\/j.ejrad.2009.03.046","volume":"72","author":"P Vock","year":"2009","unstructured":"Vock P, Szucs-Farkas Z: Dual energy subtraction: Principles and clinical applications. Eur J Radiol. 72(2):231-237, 2009. https:\/\/doi.org\/10.1016\/j.ejrad.2009.03.046","journal-title":"Eur J Radiol."},{"issue":"3","key":"1508_CR9","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1007\/s11604-009-0411-7","volume":"28","author":"S Oda","year":"2010","unstructured":"Oda S, Awai K, Funama Y, Utsunomiya D, Yanaga Y, Kawanaka K, Yamashita Y: Effects of dual-energy subtraction chest radiography on detection of small pulmonary nodules with varying attenuation: Receiver operating characteristic analysis using a phantom study. Jpn J Radiol. 28(3):214-219, 2010. https:\/\/doi.org\/10.1007\/s11604-009-0411-7","journal-title":"Jpn J Radiol."},{"issue":"1","key":"1508_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3978\/j.issn.2223-4292.2015.10.09","volume":"6","author":"F Manji","year":"2016","unstructured":"Manji F, Wang J, Norman G, Wang Z, Koff D: Comparison of dual energy subtraction chest radiography and traditional chest X-rays in the detection of pulmonary nodules. Quant Imaging Med Surg. 6(1):1-5, 2016. https:\/\/doi.org\/10.3978\/j.issn.2223-4292.2015.10.09","journal-title":"Quant Imaging Med Surg."},{"issue":"1120","key":"1508_CR11","doi-asserted-by":"publisher","first-page":"20201384","DOI":"10.1259\/bjr.20201384","volume":"94","author":"B van der Heyden","year":"2021","unstructured":"van der Heyden B: The potential application of dual-energy subtraction radiography for COVID-19 pneumonia imaging. Br J Radiol. 94(1120):20201384, 2021. https:\/\/doi.org\/10.1259\/bjr.20201384","journal-title":"Br J Radiol."},{"issue":"Suppl 6","key":"1508_CR12","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1093\/milmed\/usad034","volume":"188","author":"KS Karim","year":"2023","unstructured":"Karim KS, Tilley S: Portable single-exposure dual-energy x-ray detector for improved point-of-care diagnostic imaging. Mil Med. 188(Suppl 6):84-91, 2023. https:\/\/doi.org\/10.1093\/milmed\/usad034","journal-title":"Mil Med."},{"key":"1508_CR13","doi-asserted-by":"publisher","unstructured":"Ohashi N, Hori K, Koike T, Tadano K, Hashimoto T: Segmentation ability of pulmonary nodules using deep learning in dual-energy subtraction images, 2022 IEEE Nuclear Science Symposium and Medical Imaging Conference. (NSS\/MIC), 1\u20135, 2022. https:\/\/doi.org\/10.1109\/NSS\/MIC44845.2022.10399015","DOI":"10.1109\/NSS\/MIC44845.2022.10399015"},{"key":"1508_CR14","doi-asserted-by":"publisher","unstructured":"Kano A, Doi K, MacMahon H, Hassell DD, Giger ML: Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys. 21(3):453\u2013461, 1994. https:\/\/doi.org\/10.1118\/1.597308","DOI":"10.1118\/1.597308"},{"key":"1508_CR15","doi-asserted-by":"publisher","unstructured":"Ishida T, Katsuragawa S, Nakamura K, MacMahon H, Doi K: Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change. Med Phys. 26(7):1320\u20131329, 1999. https:\/\/doi.org\/10.1118\/1.598627","DOI":"10.1118\/1.598627"},{"key":"1508_CR16","doi-asserted-by":"publisher","unstructured":"Suzuki K, Samuel GA, Roger ME, Philip C, Heber M: Temporal subtraction of \u2018virtual dual-energy\u2019 chest radiographs for improved conspicuity of growing cancers and other pathologic changes. Proc. SPIE 7963, Medical Imaging 2011: Computer-Aided Diagnosis, 79630F, 2011. https:\/\/doi.org\/10.1117\/12.878662","DOI":"10.1117\/12.878662"},{"issue":"12","key":"1508_CR17","doi-asserted-by":"publisher","first-page":"7220","DOI":"10.3390\/app13127220","volume":"13","author":"A Yamazaki","year":"2023","unstructured":"Yamazaki A, Koshida A, Tanaka T, Seki M, Ishida T: Development of artificial intelligence-based dual-energy subtraction for chest radiography. Appl Sci. 13(12):7220, 2023. https:\/\/doi.org\/10.3390\/app13127220","journal-title":"Appl Sci."},{"issue":"1","key":"1508_CR18","doi-asserted-by":"publisher","first-page":"C01021","DOI":"10.1088\/1748-0221\/14\/01\/C01021","volume":"14","author":"DW Kim","year":"2019","unstructured":"Kim DW, Park J, Kim J, Kim HK: Noise-reduction approaches to single-shot dual-energy imaging with a multi-layer detector. J Instrum. 14(1):C01021, 2019. https:\/\/doi.org\/10.1088\/1748-0221\/14\/01\/C01021","journal-title":"J Instrum."},{"issue":"1","key":"1508_CR19","doi-asserted-by":"publisher","first-page":"9548","DOI":"10.1038\/s41598-023-36785-y","volume":"13","author":"K Minato","year":"2023","unstructured":"Minato K, Yamazaki M, Yagi T, Hirata T, Tominaga M, You K, Ishikawa H: Effectiveness of one-shot dual-energy subtraction chest radiography with flat-panel detector in distinguishing between calcified and non-calcified nodules. Sci Rep. 13(1):9548, 2023. https:\/\/doi.org\/10.1038\/s41598-023-36785-y","journal-title":"Sci Rep."},{"issue":"6","key":"1508_CR20","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1007\/s10527-022-10148-9","volume":"55","author":"YE Shunkov","year":"2022","unstructured":"Shunkov YE, Kobylkin IS, Prokhorov AV, Pozdnyakov DV, Kasiuk DM, Nechaev VA, Alekseeva OM, Naumova DI, Dabagov AR: Motion artefact reduction in dual-energy radiography. Biomed Eng. 55(6):415-419, 2022. https:\/\/doi.org\/10.1007\/s10527-022-10148-9","journal-title":"Biomed Eng."},{"issue":"2","key":"1508_CR21","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1118\/1.596372","volume":"16","author":"JT Ho","year":"1989","unstructured":"Ho JT, Kruger RA, Sorenson JA: Comparison of dual and single exposure techniques in dual-energy chest radiography. Med Phys. 16(2):202-208, 1989. https:\/\/doi.org\/10.1118\/1.596372","journal-title":"Med Phys."},{"issue":"5","key":"1508_CR22","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1118\/1.596479","volume":"17","author":"BK Stewart","year":"1990","unstructured":"Stewart BK, Huang HK: Single-exposure dual-energy computed radiography. Med Phys. 17(5):866-875, 1990. https:\/\/doi.org\/10.1118\/1.596479","journal-title":"Med Phys."},{"issue":"10","key":"1508_CR23","doi-asserted-by":"publisher","first-page":"3916","DOI":"10.1118\/1.2776239","volume":"34","author":"DB Williams","year":"2007","unstructured":"Williams DB, Siewerdsen JH, Tward DJ, Paul NS, Dhanantwari AC, Shkumat NA, Richard S, Yorkston J, Van Metter R: Optimal kvp selection for dual-energy imaging of the chest: Evaluation by task-specific observer preference tests. Med Phys. 34(10):3916-3925, 2007. https:\/\/doi.org\/10.1118\/1.2776239","journal-title":"Med Phys."},{"issue":"12","key":"1508_CR24","doi-asserted-by":"publisher","first-page":"2577","DOI":"10.1007\/s00330-003-1913-9","volume":"13","author":"J Ricke","year":"2003","unstructured":"Ricke J, Fischbach F, Freund T, Teichgr\u00e4ber U, H\u00e4nninen EL, R\u00f6ttgen R, et al: Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography. Eur Radiol. 13(12):2577-2582, 2003. https:\/\/doi.org\/10.1007\/s00330-003-1913-9","journal-title":"Eur Radiol."},{"issue":"975","key":"1508_CR25","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1259\/bjr\/24287373","volume":"82","author":"Y Kyriakou","year":"2009","unstructured":"Kyriakou Y, Ertel D, Lapp RM, Kalender WA: Reduction of motion artefacts in non-gated dual-energy radiography. Br J Radiol. 82(975):235-242, 2009. https:\/\/doi.org\/10.1259\/bjr\/24287373","journal-title":"Br J Radiol."},{"key":"1508_CR26","doi-asserted-by":"publisher","unstructured":"Sirazitdinov I, Kubrak K, Kiselev S, Tolkachev A, Kholiavchenko M, Ibragimov B: Evaluation of deep learning methods for bone suppression from dual energy chest radiography. In: Farka\u0161 I, Masulli P, Wermter S (eds) Artificial Neural Networks and Machine Learning, Lecture Notes in Computer Science ICANN2020: 12396, 2020. https:\/\/doi.org\/10.1007\/978-3-030-61609-0_20","DOI":"10.1007\/978-3-030-61609-0_20"},{"issue":"1","key":"1508_CR27","doi-asserted-by":"publisher","first-page":"8649","DOI":"10.1038\/s41598-022-12743-y","volume":"12","author":"W Liu","year":"2022","unstructured":"Liu W, Luo J, Yang Y, Wang W, Deng J, Yu L: Automatic lung segmentation in chest X-ray images using improved U-Net. Sci Rep. 12(1):8649, 2022. https:\/\/doi.org\/10.1038\/s41598-022-12743-y","journal-title":"Sci Rep."},{"key":"1508_CR28","doi-asserted-by":"publisher","unstructured":"Alshbishiri AA, Marghalani MA, Khan HA, Ahmad RG, Alqarni MA, Khan MM: Adenoid segmentation in X-ray images using U-Net. 2021 National Computing Colleges Conference (NCCC) 1\u20136, 2021. https:\/\/doi.org\/10.1109\/NCCC49330.2021.9428866","DOI":"10.1109\/NCCC49330.2021.9428866"},{"key":"1508_CR29","doi-asserted-by":"publisher","unstructured":".Hertel R, Benlamri R: A deep learning segmentation-classification pipeline for X-ray-based COVID-19 diagnosis. Biomed Eng Adv. 3:100041, 2022, https:\/\/doi.org\/10.1016\/j.bea.2022.100041","DOI":"10.1016\/j.bea.2022.100041"},{"issue":"3","key":"1508_CR30","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1007\/s10278-024-01017-w","volume":"37","author":"Y Ueda","year":"2024","unstructured":"Ueda Y, Ogawa D, Ishida T: Patient re-identification based on deep metric learning in trunk computed tomography images acquired from devices from different vendors. J Imaging Inform Med. 37(3):1124-1136, 2024. https:\/\/doi.org\/10.1007\/s10278-024-01017-w","journal-title":"J Imaging Inform Med."},{"issue":"5","key":"1508_CR31","doi-asserted-by":"publisher","first-page":"1941","DOI":"10.1007\/s10278-023-00850-9","volume":"36","author":"Y Ueda","year":"2023","unstructured":"Ueda Y, Morishita J: Patient identification based on deep metric learning for preventing human errors in follow-up X-ray examinations. J Digit Imaging. 36(5):1941-1953, 2023. https:\/\/doi.org\/10.1007\/s10278-023-00850-9","journal-title":"J Digit Imaging."},{"issue":"12","key":"1508_CR32","doi-asserted-by":"publisher","first-page":"9654","DOI":"10.1007\/s00330-021-08050-1","volume":"31","author":"D Keidar","year":"2021","unstructured":"Keidar D, Yaron D, Goldstein E, et al: COVID-19 classification of X-ray images using deep neural networks. Eur Radiol. 31(12):9654-9663, 2021. https:\/\/doi.org\/10.1007\/s00330-021-08050-1","journal-title":"Eur Radiol."},{"issue":"7","key":"1508_CR33","doi-asserted-by":"publisher","first-page":"1333","DOI":"10.1007\/s11548-022-02586-3","volume":"17","author":"J Van Houtte","year":"2022","unstructured":"Van Houtte J, Audenaert E, Zheng G, Sijbers J: Deep learning-based 2D\/3D registration of an atlas to biplanar X-ray images. Int J Comput Assist Radiol Surg. 17(7):1333-1342, 2022. https:\/\/doi.org\/10.1007\/s11548-022-02586-3","journal-title":"Int J Comput Assist Radiol Surg."},{"key":"1508_CR34","doi-asserted-by":"publisher","unstructured":"Goodfellow IJ, Pouget-Abadie M, Mirza B, Xu D, Warde-Farley S, Ozair AC, Bengio Y: Generative adversarial networks. stat. ML 1\u20139, 2014. https:\/\/doi.org\/10.48550\/arXiv.1406.2661","DOI":"10.48550\/arXiv.1406.2661"},{"key":"1508_CR35","doi-asserted-by":"crossref","unstructured":"Liu J, Li K, Dong H, Han Y, Li R: Medical image processing based on generative adversarial networks: A systematic review. Curr Med Imaging. 2023.","DOI":"10.2174\/0115734056258198230920042358"},{"key":"1508_CR36","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2022.107200","volume":"229","author":"Y Chen","year":"2023","unstructured":"Chen Y, Lin Y, Xu X, Ding J, Li C, Zeng Y, Xie W, Huang J: Multi-domain medical image translation generation for lung image classification based on generative adversarial networks. Comput Methods Programs Biomed. 229:107200, 2023. https:\/\/doi.org\/10.1016\/j.cmpb.2022.107200","journal-title":"Comput Methods Programs Biomed."},{"key":"1508_CR37","doi-asserted-by":"publisher","unstructured":"Isola P, Zhu JY, Zhou T, Efros AA: Image-to-image translation with conditional adversarial networks. 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), 5967\u20135976, 2017. https:\/\/doi.org\/10.1109\/CVPR.2017.632","DOI":"10.1109\/CVPR.2017.632"},{"key":"1508_CR38","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1118\/1.3036981","volume":"36","author":"GJ Gang","year":"2009","unstructured":"Gang GJ, Varon CA, Kashani H, Richard S, Paul NS, Van Metter R, Yorkston J, Siewerdsen JH: Multiscale deformable registration for dual-energy x-ray imaging. Med Phys. 36:351-363, 2009. https:\/\/doi.org\/10.1118\/1.3036981","journal-title":"Med Phys."},{"key":"1508_CR39","doi-asserted-by":"publisher","unstructured":"Palaniappan P, Steininger P, Messner IM, Deutschmann H, Parodi K, Landry G, Riboldi M: Motion Compensation in dual energy X-ray imaging based on deformable image registration. 2019 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS\/MIC), 1\u20132, 2019. https:\/\/doi.org\/10.1109\/NSS\/MIC42101.2019.9059964","DOI":"10.1109\/NSS\/MIC42101.2019.9059964"},{"key":"1508_CR40","doi-asserted-by":"publisher","first-page":"55448","DOI":"10.1109\/ACCESS.2024.3390245","volume":"12","author":"Y Heng","year":"2024","unstructured":"Heng Y, Yinghua M, Khan FG, Khan A, Hui Z: HLSNC-GAN: Medical image synthesis using hinge loss and switchable normalization in CycleGAN. IEEE Access. 12:55448-55464, 2024, https:\/\/doi.org\/10.1109\/ACCESS.2024.3390245","journal-title":"IEEE Access."},{"key":"1508_CR41","doi-asserted-by":"publisher","unstructured":"Zhu JY, Park T, Isola P, Efros AA: Unpaired image-to-image translation using cycle-consistent adversarial networks IEEE International Conference on Computer Vision (ICCV), 2242\u20132251, 2017. https:\/\/doi.org\/10.1109\/ICCV.2017.244","DOI":"10.1109\/ICCV.2017.244"},{"key":"1508_CR42","doi-asserted-by":"publisher","unstructured":"Chang H, Lu J, Yu F, Finkelstein A: PairedCycleGAN: Asymmetric style transfer for applying and removing makeup, 2018 IEEE\/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 40\u201348, 2018. https:\/\/doi.org\/10.1109\/CVPR.2018.00012","DOI":"10.1109\/CVPR.2018.00012"},{"issue":"9","key":"1508_CR43","doi-asserted-by":"publisher","first-page":"3998","DOI":"10.1002\/mp.13656","volume":"46","author":"J Harms","year":"2019","unstructured":"Harms J, Lei Y, Wang T, Zhang R, Zhou J, Tang X, Curran WJ, Liu T, Yang X: Paired cycle-GAN-based image correction for quantitative cone-beam computed tomography. Med Phys. 46(9):3998-4009, 2019. https:\/\/doi.org\/10.1002\/mp.13656","journal-title":"Med Phys."},{"issue":"10","key":"1508_CR44","doi-asserted-by":"publisher","first-page":"2361","DOI":"10.3390\/s19102361","volume":"19","author":"CB Jin","year":"2019","unstructured":"Jin CB, Kim H, Liu M, Jung W, Joo S, Park E, Ahn YS, Han IH, Lee JI, Cui X: Deep CT to MR synthesis using paired and unpaired data. Sensors (Basel). 19(10):2361, 2019. https:\/\/doi.org\/10.3390\/s19102361","journal-title":"Sensors (Basel)."},{"key":"1508_CR45","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2022.102094","volume":"100","author":"J Liu","year":"2022","unstructured":"Liu J, Tian Y, Duzgol C, Akin O, A\u011f\u0131ldere AM, Haberal KM, Co\u015fkun M: Virtual contrast enhancement for CT scans of abdomen and pelvis. Comput Med Imaging Graph. 100:102094, 2022. https:\/\/doi.org\/10.1016\/j.compmedimag.2022.102094","journal-title":"Comput Med Imaging Graph."},{"key":"1508_CR46","doi-asserted-by":"publisher","DOI":"10.1016\/j.compmedimag.2024.102398","volume":"116","author":"A Rofena","year":"2024","unstructured":"Rofena A, Guarrasi V, Sarli M, Piccolo CL, Sammarra M, Zobel BB, Soda P: A deep learning approach for virtual contrast enhancement in contrast enhanced spectral mammography. Comput Med Imaging Graph. 116:102398, 2024. https:\/\/doi.org\/10.1016\/j.compmedimag.2024.102398","journal-title":"Comput Med Imaging Graph."},{"key":"1508_CR47","doi-asserted-by":"publisher","unstructured":"Johnson J, Alahi A, Fei-Fei L: Perceptual losses for real-time style transfer and super-resolution. In: Computer Vision \u2013 ECCV 2016, ECCV 2016, 9906, 2016. https:\/\/doi.org\/10.1007\/978-3-319-46475-6_43","DOI":"10.1007\/978-3-319-46475-6_43"},{"key":"1508_CR48","unstructured":"Zhang R: Making convolutional networks shift-invariant again. International conference on machine learning PMLR, 7324\u20137334, 2019. https:\/\/arxiv.org\/pdf\/1904.11486"},{"key":"1508_CR49","doi-asserted-by":"publisher","unstructured":"Zhao S, Liu Z, Lin J, Zhu JY, Han S: Differentiable augmentation for data efficient GAN training. Conference on Neural Information Processing Systems (NeurIPS) 202033:7559\u20137570, 2020. https:\/\/doi.org\/10.48550\/arXiv.2006.10738","DOI":"10.48550\/arXiv.2006.10738"},{"key":"1508_CR50","doi-asserted-by":"publisher","unstructured":"Kumari N, Zhang R, Shechtman E, Zhu J: Ensembling off-the-shelf models for GAN training. 2022 IEEE\/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 10641\u201310652, 2022. https:\/\/doi.org\/10.1109\/CVPR52688.2022.01039","DOI":"10.1109\/CVPR52688.2022.01039"},{"key":"1508_CR51","doi-asserted-by":"publisher","first-page":"9351","DOI":"10.1007\/978-3-319-24574-4_28","volume":"2015","author":"O Ronneberger","year":"2015","unstructured":"Ronneberger O, Fischer P, Brox T: U-Net: Convolutional networks for biomedical image segmentation. Med Image Comput Comput Assist Interv MICCAI, MICCAI 2015, 9351, 2015. https:\/\/doi.org\/10.1007\/978-3-319-24574-4_28","journal-title":"Med Image Comput Comput Assist Interv MICCAI, MICCAI"},{"key":"1508_CR52","unstructured":"Ulyanov D, Vedaldi A, Lempitsky VS: Instance normalization: the missing ingredient for fast stylization. 2016, Preprint at https:\/\/arxiv.org\/abs\/1607.08022"},{"key":"1508_CR53","doi-asserted-by":"publisher","unstructured":"Yun S, Han D, Oh SJ, Chun S, Choe J, Yoo Y: CutMix: Regularization strategy to train strong classifiers with localizable features, 2019 IEEE\/CVF International Conference on Computer Vision (ICCV), 6022\u20136031. https:\/\/doi.org\/10.1109\/ICCV.2019.00612","DOI":"10.1109\/ICCV.2019.00612"},{"key":"1508_CR54","doi-asserted-by":"publisher","unstructured":"Zhang H, Zhang Z, Odena A, Lee H: Consistency regularization for generative adversarial networks. International Conference on Learning Representations (ICLR), 2020. https:\/\/doi.org\/10.48550\/arXiv.1910.12027v2","DOI":"10.48550\/arXiv.1910.12027v2"},{"key":"1508_CR55","doi-asserted-by":"publisher","unstructured":"Simonyan K, Zisserman A: Very deep convolutional networks for large-scale image recognition. 3rd International Conference on Learning Representations (ICLR 2015), 1\u201314, 2015. https:\/\/doi.org\/10.48550\/arXiv.1409.1556","DOI":"10.48550\/arXiv.1409.1556"},{"key":"1508_CR56","doi-asserted-by":"publisher","unstructured":"Miyato T, Kataoka T, Koyama M, Yoshida Y: Spectral normalization for generative adversarial networks. arXiv preprint arXiv:1802.05957, 2018. https:\/\/doi.org\/10.48550\/arXiv.1802.05957","DOI":"10.48550\/arXiv.1802.05957"},{"key":"1508_CR57","doi-asserted-by":"publisher","unstructured":"Karras T, Aittala M, Hellsten J, Laine S, Lehtinen J, Aila T: Training generative adversarial networks with limited data. Proceedings of the 34th International Conference on Neural Information Processing Systems (NIPS \u201920). 1015:12104\u201312114, 2020. https:\/\/doi.org\/10.48550\/arXiv.2006.06676","DOI":"10.48550\/arXiv.2006.06676"},{"key":"1508_CR58","doi-asserted-by":"publisher","unstructured":"Azam MHN, Ridzuan F, Sayuti MNSM: A new method to estimate peak signal to noise ratio for least significant bit modification audio steganography. Pertanika J Sci Technol. 30(1):497\u2013511, 2022. https:\/\/doi.org\/10.47836\/pjst.30.1.27","DOI":"10.47836\/pjst.30.1.27"},{"key":"1508_CR59","doi-asserted-by":"publisher","unstructured":"Bakurov I, Buzzelli M, Schettini R, Castelli M, Vanneschi L: Structural similarity index (SSIM) revisited: A data-driven approach. Expert Syst Appl. 189, 2022. https:\/\/doi.org\/10.1016\/j.eswa.2021.116087","DOI":"10.1016\/j.eswa.2021.116087"},{"key":"1508_CR60","doi-asserted-by":"publisher","unstructured":"Heusel M, Ramsauer H, Unterthiner T, Nessler B, Hochreiter S: GANs trained by a two time-scale update rule converge to a local nash equilibrium. Proceedings of the 31st International Conference on Neural Information Processing Systems (NIPS\u201917), 6629\u20136640, 2017. https:\/\/doi.org\/10.48550\/arXiv.1706.08500","DOI":"10.48550\/arXiv.1706.08500"},{"issue":"3","key":"1508_CR61","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1118\/1.594957","volume":"8","author":"WR Brody","year":"1981","unstructured":"Brody WR, Butt G, Hall A, Macovski A: A method for selective tissue and bone visualization using dual energy scanned projection radiography. Med Phys. 8(3):353-357, 1981. https:\/\/doi.org\/10.1118\/1.594957","journal-title":"Med Phys."},{"key":"1508_CR62","doi-asserted-by":"publisher","unstructured":"Loshchilov I, Hutter F: Decoupled weight decay regularization. international conference on learning representations (ICLR2019), 2019. https:\/\/doi.org\/10.48550\/arXiv.1711.05101v3","DOI":"10.48550\/arXiv.1711.05101v3"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01508-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01508-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01508-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T18:46:17Z","timestamp":1771526777000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01508-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,5]]},"references-count":62,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["1508"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01508-4","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,5]]},"assertion":[{"value":"21 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures in this study conformed with the ethical standards of the Institutional Review Board at each author\u2019s affiliated institution and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"Written informed consent was not required for this study because of its retrospective nature.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"Written consent of the study participants or their legal guardians was not required to publish the data of the individuals in the manuscript because of the retrospective nature of this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}