{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T07:03:28Z","timestamp":1793948608329,"version":"4.8.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T00:00:00Z","timestamp":1746489600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T00:00:00Z","timestamp":1746489600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001711","name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung","doi-asserted-by":"publisher","award":["SNSF 320030_231742"],"award-info":[{"award-number":["SNSF 320030_231742"]}],"id":[{"id":"10.13039\/501100001711","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006389","name":"University of Geneva","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100006389","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Quantitative cardiovascular PET\/CT imaging is useful in the diagnosis of multiple cardiac perfusion and motion pathologies. The common approach for cardiac segmentation consists in using co-registered CT images, exploiting publicly available deep learning (DL)-based segmentation models. However, the mismatch between structural CT images and PET uptake limits the usefulness of these approaches. Besides, the performance of DL models is not consistent over low-dose or ultra-low-dose CT images commonly used in clinical PET\/CT imaging. In this work, we developed a DL-based methodology to tackle this issue by segmenting directly cardiac PET images. This study included 406 cardiac PET images from 146 patients (43\n                    <jats:sup>18<\/jats:sup>\n                    F-FDG, 329\n                    <jats:sup>13<\/jats:sup>\n                    N-NH\n                    <jats:sub>3<\/jats:sub>\n                    , and 37\n                    <jats:sup>82<\/jats:sup>\n                    Rb images). Using previously trained DL nnU-Net models in our group, we segmented the whole heart and the three main cardiac components, namely the left myocardium (LM), left ventricle cavity (LV), and right ventricle (RV) on co-registered CT images. The segmentation was resampled to PET resolution and edited through a combination of automated image processing and manual correction. The corrected segmentation masks and SUV PET images were fed to a nnU-Net V2 pipeline to be trained in fivefold data split strategy by defining two tasks: task #1 for whole cardiac segmentation and task #2 for segmentation of three cardiac components. Fifteen cardiac images were used as external validation set. The DL delineated masks were compared with standard of reference masks using Dice coefficient, Jaccard distance, mean surface distance, and segment volume relative error (%). Task #1 average Dice coefficient in internal validation fivefold was 0.932\u2009\u00b1\u20090.033. The average Dice on the 15 external cases were comparable with the fivefold Dice reaching an average of 0.941\u2009\u00b1\u20090.018. Task #2 average Dice in fivefold validation was 0.88\u2009\u00b1\u20090.063, 0.828\u2009\u00b1\u20090.091, and 0.876\u2009\u00b1\u20090.062 for LM, LV, and RV, respectively. There was no statistically significant difference among the Dice coefficients, neither between images acquired by three radiotracers nor between the different folds (\n                    <jats:italic>P<\/jats:italic>\n                    -values\u2009&gt;\u2009\u2009&gt;\u20090.05). The overall average volume prediction error in cardiac components segmentation was less than 2%. We developed an automated DL-based segmentation pipeline to segment the whole heart and cardiac components with acceptable accuracy and robust performance in the external test set and over three radiotracers used in nuclear cardiovascular imaging. The proposed methodology can overcome unreliable segmentations performed on CT images.\n                  <\/jats:p>","DOI":"10.1007\/s10278-025-01528-0","type":"journal-article","created":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T13:44:48Z","timestamp":1746539088000},"page":"933-947","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Deep Learning-Based CT-Less Cardiac Segmentation of PET Images: A Robust Methodology for Multi-Tracer Nuclear Cardiovascular Imaging"],"prefix":"10.1007","volume":"39","author":[{"given":"Yazdan","family":"Salimi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahra","family":"Mansouri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9","family":"Nkoulou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ismini","family":"Mainta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7559-5297","authenticated-orcid":false,"given":"Habib","family":"Zaidi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,6]]},"reference":[{"key":"1528_CR1","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/s40336-014-0070-2","volume":"2","author":"P Slomka","year":"2014","unstructured":"Slomka P, Berman DS, Alexanderson E, Germano G. The role of PET quantification in cardiovascular imaging. Clinical and Translational Imaging. 2014;2:343-58.","journal-title":"Clinical and Translational Imaging."},{"key":"1528_CR2","doi-asserted-by":"crossref","unstructured":"Rasmussen LD, Gormsen LC, Ejlersen JA, Karim SR, Westra J, Knudsen LL, et al. Impact of Absolute Myocardial Blood Flow Quantification on the Diagnostic Performance of PET-Based Perfusion Scans Using 82Rubidium. Circulation: Cardiovascular Imaging. 2024;17:e016138.","DOI":"10.1161\/CIRCIMAGING.123.016138"},{"key":"1528_CR3","doi-asserted-by":"publisher","first-page":"20230704","DOI":"10.1259\/bjr.20230704","volume":"96","author":"HSA Tingen","year":"2023","unstructured":"Tingen HSA, van Praagh GD, Nienhuis PH, Tubben A, van Rijsewijk ND, ten Hove D, et al. The clinical value of quantitative cardiovascular molecular imaging: a step towards precision medicine. British Journal of Radiology. 2023;96:20230704.","journal-title":"British Journal of Radiology."},{"issue":"8","key":"1528_CR4","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.3390\/diagnostics11081421","volume":"11","author":"B Saboury","year":"2021","unstructured":"Saboury B, Edenbrandt L, Piri R, Gerke O, Werner T, Arbab-Zadeh A et al. Alavi-Carlsen Calcification Score (ACCS): A Simple Measure of Global Cardiac Atherosclerosis Burden. Diagnostics; 2021;11(8):1421.","journal-title":"Diagnostics"},{"key":"1528_CR5","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1097\/RLU.0000000000005400","volume":"49","author":"Y Salimi","year":"2024","unstructured":"Salimi Y, Hajianfar G, Mansouri Z, Sanaat Y, Amini M, Shiri I, et al. Organomics: A novel concept reflecting the importance of PET\/CT healthy organ radiomics in non-small cell lung cancer prognosis prediction using machine learning. Clin Nucl Med. 2024;49:899-908.","journal-title":"Clin Nucl Med."},{"key":"1528_CR6","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1007\/s00259-022-06001-6","volume":"50","author":"M Hatt","year":"2023","unstructured":"Hatt M, Krizsan AK, Rahmim A, Bradshaw TJ, Costa PF, Forgacs A, et al. Joint EANM\/SNMMI guideline on radiomics in nuclear medicine : Jointly supported by the EANM Physics Committee and the SNMMI Physics, Instrumentation and Data Sciences Council. Eur J Nucl Med Mol Imaging. 2023;50:352-75.","journal-title":"Eur J Nucl Med Mol Imaging."},{"issue":"7","key":"1528_CR7","doi-asserted-by":"publisher","first-page":"744","DOI":"10.1007\/s11604-024-01546-y","volume":"42","author":"M Nakajo","year":"2024","unstructured":"Nakajo M, Hirahara D, Jinguji M, Ojima S, Hirahara M, Tani A et al. Machine learning approach using 18F-FDG-PET-radiomic features and the visibility of right ventricle 18F-FDG uptake for predicting clinical events in patients with cardiac sarcoidosis. Japanese J Radiol.\u00a02024;42(7):744-752.","journal-title":"Japanese J Radiol."},{"key":"1528_CR8","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1007\/s11547-023-01658-x","volume":"128","author":"T Polidori","year":"2023","unstructured":"Polidori T, De Santis D, Rucci C, Tremamunno G, Piccinni G, Pugliese L, et al. Radiomics applications in cardiac imaging: a comprehensive review. La radiologia medica. 2023;128:922-33.","journal-title":"La radiologia medica."},{"key":"1528_CR9","doi-asserted-by":"publisher","first-page":"e230024","DOI":"10.1148\/ryai.230024","volume":"5","author":"J Wasserthal","year":"2023","unstructured":"Wasserthal J, Breit HC, Meyer MT, Pradella M, Hinck D, Sauter AW, et al. TotalSegmentator: Robust Segmentation of 104 Anatomic Structures in CT Images. Radiology Artificial intelligence. 2023;5:e230024.","journal-title":"Radiology Artificial intelligence."},{"key":"1528_CR10","doi-asserted-by":"publisher","first-page":"104911","DOI":"10.1016\/j.ejmp.2025.104911","volume":"130","author":"Y Salimi","year":"2025","unstructured":"Salimi Y, Shiri I, Mansouri Z, Zaidi H. Development and validation of fully automated robust deep learning models for multi-organ segmentation from whole-body CT images. Phys Med. 2025;130:104911.","journal-title":"Phys Med."},{"key":"1528_CR11","doi-asserted-by":"publisher","first-page":"2292","DOI":"10.1007\/s00259-023-06181-9","volume":"50","author":"J Schaefferkoetter","year":"2023","unstructured":"Schaefferkoetter J, Shah V, Hayden C, Prior JO, Zuehlsdorff S. Deep learning for improving PET\/CT attenuation correction by elastic registration of anatomical data. Eur J Nucl Med Mol Imaging. 2023;50:2292-304.","journal-title":"Eur J Nucl Med Mol Imaging."},{"key":"1528_CR12","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1002\/mp.16862","volume":"51","author":"S Mostafapour","year":"2024","unstructured":"Mostafapour S, Greuter M, van Snick JH, Brouwers AH, Dierckx R, van Sluis J, et al. Ultra-low dose CT scanning for PET\/CT. Med Phys. 2024;51:139-55.","journal-title":"Med Phys."},{"key":"1528_CR13","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/s40658-023-00585-0","volume":"10","author":"NA Bebbington","year":"2023","unstructured":"Bebbington NA, Christensen KB, \u00d8sterg\u00e5rd LL, Holdgaard PC. Ultra-low-dose CT for attenuation correction: dose savings and effect on PET quantification for protocols with and without tin filter. EJNMMI Physics. 2023;10:66.","journal-title":"EJNMMI Physics."},{"key":"1528_CR14","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1097\/RLU.0000000000004912","volume":"48","author":"I Shiri","year":"2023","unstructured":"Shiri I, Salimi Y, Hervier E, Pezzoni A, Sanaat A, Mostafaei S, et al. Artificial Intelligence-Driven Single-Shot PET Image Artifact Detection and Disentanglement: Toward Routine Clinical Image Quality Assurance. Clin Nucl Med. 2023;48:1035-46.","journal-title":"Clin Nucl Med."},{"key":"1528_CR15","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1007\/s00259-023-06418-7","volume":"51","author":"I Shiri","year":"2023","unstructured":"Shiri I, Salimi Y, Maghsudi M, Jenabi E, Harsini S, Razeghi B, et al. Differential privacy preserved federated transfer learning for multi-institutional (68)Ga-PET image artefact detection and disentanglement. Eur J Nucl Med Mol Imaging. 2023;51:40-53.","journal-title":"Eur J Nucl Med Mol Imaging."},{"key":"1528_CR16","doi-asserted-by":"publisher","first-page":"165007","DOI":"10.1088\/1361-6560\/ac840e","volume":"67","author":"B Wang","year":"2022","unstructured":"Wang B, Lu L, Liu H. DeTransUnet: attenuation correction of gated cardiac images without structural information. Physics in Medicine & Biology. 2022;67:165007.","journal-title":"Physics in Medicine & Biology."},{"key":"1528_CR17","doi-asserted-by":"publisher","first-page":"101805","DOI":"10.1016\/j.nuclcard.2024.101805","volume":"32","author":"MC Williams","year":"2024","unstructured":"Williams MC. Machine learning models for positron emission tomography myocardial perfusion imaging. Journal of Nuclear Cardiology. 2024;32:101805.","journal-title":"Journal of Nuclear Cardiology."},{"key":"1528_CR18","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1007\/s10554-013-0207-9","volume":"29","author":"H Zaidi","year":"2013","unstructured":"Zaidi H, Nkoulou R, Bond S, Baskin A, Schindler T, Ratib O, et al. Computed tomography calcium score scan for attenuation correction of N-13 ammonia cardiac positron emission tomography: effect of respiratory phase and registration method. Int J Cardiovasc Imaging. 2013;29:1351-60.","journal-title":"Int J Cardiovasc Imaging."},{"key":"1528_CR19","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1186\/s40658-023-00539-6","volume":"10","author":"SM Entezarmahdi","year":"2023","unstructured":"Entezarmahdi SM, Faghihi R, Yazdi M, Shahamiri N, Geramifar P, Haghighatafshar M. QCard-NM: Developing a semiautomatic segmentation method for quantitative analysis of the right ventricle in non-gated myocardial perfusion SPECT imaging. EJNMMI Phys. 2023;10:21.","journal-title":"EJNMMI Phys."},{"issue":"6","key":"1528_CR20","doi-asserted-by":"publisher","first-page":"2044","DOI":"10.1002\/ima.22929","volume":"33","author":"CK Sadhanandan","year":"2023","unstructured":"Sadhanandan CK, Tharcis Mariapushpam I, Suresh S. An efficient deep learning algorithm for the segmentation of cardiac ventricles. International Journal of Imaging Systems and Technology. 2023;33(6):2044-2060","journal-title":"International Journal of Imaging Systems and Technology"},{"key":"1528_CR21","doi-asserted-by":"crossref","unstructured":"Sz\u0171cs \u00c1I, K\u00e1ri B, P\u00e1rtos O. Continuous max-flow augmentation of self-supervised few-shot learning on SPECT left ventricles. arXiv preprint arXiv:240505520. 2024;2405.05520.","DOI":"10.1109\/ISBI56570.2024.10635433"},{"key":"1528_CR22","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40644-024-00675-x","volume":"24","author":"E Yazdani","year":"2024","unstructured":"Yazdani E, Karamzadeh-Ziarati N, Cheshmi SS, Sadeghi M, Geramifar P, Vosoughi H, et al. Automated segmentation of lesions and organs at risk on [68Ga]Ga-PSMA-11 PET\/CT images using self-supervised learning with Swin UNETR. Cancer Imaging. 2024;24:30.","journal-title":"Cancer Imaging."},{"key":"1528_CR23","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s12880-022-00785-7","volume":"22","author":"X Wang","year":"2022","unstructured":"Wang X, Jemaa S, Fredrickson J, Coimbra AF, Nielsen T, De Crespigny A, et al. Heart and bladder detection and segmentation on FDG PET\/CT by deep learning. BMC Medical Imaging. 2022;22:58.","journal-title":"BMC Medical Imaging."},{"key":"1528_CR24","doi-asserted-by":"publisher","first-page":"107267","DOI":"10.1016\/j.cmpb.2022.107267","volume":"229","author":"Y Zhang","year":"2023","unstructured":"Zhang Y, Wang F, Wu H, Yang Y, Xu W, Wang S, et al. An automatic segmentation method with self-attention mechanism on left ventricle in gated PET\/CT myocardial perfusion imaging. Computer Methods and Programs in Biomedicine. 2023;229:107267.","journal-title":"Computer Methods and Programs in Biomedicine."},{"key":"1528_CR25","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1097\/RLU.0000000000005685","volume":"50","author":"Y Salimi","year":"2025","unstructured":"Salimi Y, Mansouri Z, Shiri I, Mainta I, Zaidi H. Deep learning-powered CT-less multi-tracer organ segmentation from PET images: A solution for unreliable CT segmentation in PET\/CT imaging. Clin Nucl Med. 2025;50:289-300.","journal-title":"Clin Nucl Med."},{"key":"1528_CR26","doi-asserted-by":"publisher","first-page":"e12097","DOI":"10.1002\/pul2.12097","volume":"12","author":"C G\u00f6ransson","year":"2022","unstructured":"G\u00f6ransson C, Vejlstrup N, Carlsen J. Clinically important changes in right ventricular volume and function in pulmonary arterial hypertension assessed with cardiac magnetic resonance imaging. Pulm Circ. 2022;12:e12097.","journal-title":"Pulm Circ."},{"key":"1528_CR27","doi-asserted-by":"crossref","unstructured":"Josselyn N, MacLean MT, Jean C, Fuchs B, Moon BF, Hwuang E, et al. Classification of Myocardial 18F-FDG PET Uptake Patterns Using Deep Learning. Radiology: Artificial Intelligence. 2021;3:e200148.","DOI":"10.1148\/ryai.2021200148"},{"key":"1528_CR28","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","volume":"31","author":"PA Yushkevich","year":"2006","unstructured":"Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, et al. User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. NeuroImage. 2006;31:1116-28.","journal-title":"NeuroImage."},{"key":"1528_CR29","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1038\/s41592-020-01008-z","volume":"18","author":"F Isensee","year":"2021","unstructured":"Isensee F, Jaeger PF, Kohl SAA, Petersen J, Maier-Hein KH. nnU-Net: a self-configuring method for deep learning-based biomedical image segmentation. Nat Methods. 2021;18:203-11.","journal-title":"Nat Methods."},{"key":"1528_CR30","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1146\/annurev-bioeng-082420-020343","volume":"23","author":"H Zaidi","year":"2021","unstructured":"Zaidi H, El Naqa I. Quantitative molecular positron emission tomography imaging using advanced deep learning techniques. Annu Rev Biomed Eng. 2021;23:249-76.","journal-title":"Annu Rev Biomed Eng."},{"key":"1528_CR31","doi-asserted-by":"crossref","unstructured":"Tsanda A, Nickisch H, Wissel T, Klinder T, Knopp T, Grass M. On TotalSegmentator\u2019s performance on low-dose CT images. Proc. SPIE; 2024; p. 129260B.","DOI":"10.1117\/12.3000186"},{"key":"1528_CR32","doi-asserted-by":"publisher","unstructured":"Salimi Y, Mansouri Z, Sun C, Sanaat A, Yazdanpanah M, Shooli H, et al. Deep learning-based segmentation of ultra-low-dose CT images using an optimized nnU-Net model. Radiol Med. 2025: in press https:\/\/doi.org\/10.1007\/s11547-025-01989-x","DOI":"10.1007\/s11547-025-01989-x"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01528-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01528-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01528-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T18:46:30Z","timestamp":1771526790000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01528-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,6]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["1528"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01528-0","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,6]]},"assertion":[{"value":"27 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. The study was approved by the Ethics committee of the Canton of Geneva, Switzerland. Consent forms were waived owing to the retrospective nature of the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"All authors approved the final version of the manuscript and consent to give the Publisher the permission to publish the work.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for Publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}