{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T10:05:06Z","timestamp":1780394706302,"version":"3.54.1"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T00:00:00Z","timestamp":1756252800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T00:00:00Z","timestamp":1756252800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Seoul Business Agency","award":["BT230113"],"award-info":[{"award-number":["BT230113"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Volumetric estimation of affected brain volumes using computed tomography perfusion (CTP) is crucial in the management of acute ischemic stroke (AIS) and relies on commercial software, which has limitations such as variations in results due to image quality. To predict affected brain volume accurately and robustly, we propose a hybrid approach that integrates singular value decomposition (SVD), deep learning (DL), and machine learning (ML) techniques. We included 449 CTP images of patients with AIS with manually annotated vessel landmarks provided by expert radiologists, collected between 2021 and 2023. We developed a CNN-based approach for predicting eight vascular landmarks from CTP images, integrating ML components. We then used SVD-related methods to generate perfusion maps and compared the results with those of the RapidAI software (RapidAI, Menlo Park, California). The proposed CNN model achieved an average Euclidean distance error of 4.63\n                    <jats:inline-formula>\n                      <jats:alternatives>\n                        <jats:tex-math>$$\\pm$$<\/jats:tex-math>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                          <mml:mo>\u00b1<\/mml:mo>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    2.00\u00a0mm on the vessel localization. Without the ML components, compared to RapidAI, our method yielded concordance correlation coefficient (CCC) scores of 0.898 for estimating volumes with cerebral blood flow (CBF)\u2009&lt;\u200930% and 0.715 for Tmax\u2009&gt;\u20096\u00a0s. Using the ML method, it achieved CCC scores of 0.905 for CBF\u2009&lt;\u200930% and 0.879 for Tmax\u2009&gt;\u20096\u00a0s. For the data assessment, it achieved 0.8 accuracy. We developed a robust hybrid model combining DL and ML techniques for volumetric estimation of affected brain volumes using CTP in patients with AIS, demonstrating improved accuracy and robustness compared to existing commercial solutions.\n                  <\/jats:p>","DOI":"10.1007\/s10278-025-01612-5","type":"journal-article","created":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T21:50:33Z","timestamp":1756331433000},"page":"2095-2109","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Robust Quantification of Affected Brain Volume from Computed Tomography Perfusion: A Hybrid Approach Combining Deep Learning and Singular Value Decomposition"],"prefix":"10.1007","volume":"39","author":[{"given":"Gi-Youn","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyeon Sik","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jundong","family":"Hwang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kijeong","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Wook","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Woo Sang","family":"Jung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Regina Eun Young","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donghyeon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4821-0221","authenticated-orcid":false,"given":"Minho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,27]]},"reference":[{"key":"1612_CR1","doi-asserted-by":"publisher","unstructured":"Campbell BCV, Christensen S, Levi CR, Desmond PM, Donnan GA, Davis SM, Parsons MW: Comparison of Computed Tomography Perfusion and Magnetic Resonance Imaging Perfusion-Diffusion Mismatch in Ischemic Stroke.\u00a0Stroke. https:\/\/doi.org\/10.1161\/STROKEAHA.112.660548, 2012","DOI":"10.1161\/STROKEAHA.112.660548"},{"key":"1612_CR2","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/S1474-4422(08)70230-8","volume":"7","author":"GA Donnan","year":"2008","unstructured":"Donnan GA, Davis SM: Breaking the 3 h barrier for treatment of acute ischaemic stroke.\u00a0Lancet Neurol 7:981\u2013982, 2008","journal-title":"Lancet Neurol"},{"key":"1612_CR3","doi-asserted-by":"publisher","unstructured":"Kuang H, Tan X, Wang J, Qu Z, Cai Y, Chen Q, Kim BJ, Qiu W: Segmenting Ischemic Penumbra and Infarct Core Simultaneously on Non-Contrast CT of Patients with Acute Ischemic Stroke Using Novel Convolutional Neural Network.\u00a0Biomedicines. https:\/\/doi.org\/10.3390\/biomedicines12030580, 2024","DOI":"10.3390\/biomedicines12030580"},{"key":"1612_CR4","doi-asserted-by":"publisher","first-page":"531","DOI":"10.3897\/folmed.65.e96954","volume":"65","author":"E Halil","year":"2023","unstructured":"Halil E: CT perfusion \u2013 an up-to-date element of the contemporary multimodal diagnostic approach to acute ischemic stroke.\u00a0Folia Med 65:531\u2013538, 2023","journal-title":"Folia Med"},{"key":"1612_CR5","doi-asserted-by":"publisher","first-page":"27","DOI":"10.3174\/ng.2100037","volume":"13","author":"JA Bregni","year":"2023","unstructured":"Bregni JA, Castillo M, Ho JP, Zamora C: A RAPID Checklist: Understanding Pitfalls and Artifacts in Stroke.\u00a0Neurographics 13:27\u201334, 2023","journal-title":"Neurographics"},{"key":"1612_CR6","first-page":"2019","volume":"41\u201355","author":"B Laughlin","year":"2019","unstructured":"Laughlin B, Chan A, Tai WA, Moftakhar P: RAPID automated CT perfusion in clinical practice.\u00a0Pract Neurol 2019:41\u201355, 2019","journal-title":"Pract Neurol"},{"key":"1612_CR7","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1212\/WNL.0000000000008481","volume":"93","author":"A Vagal","year":"2019","unstructured":"Vagal A, Wintermark M, Nael K, Bivard A, Parsons M, Grossman AW, Khatri P: Automated CT perfusion imaging for acute ischemic stroke: pearls and pitfalls for real-world use.\u00a0Neurology 93:888\u2013898, 2019","journal-title":"Neurology"},{"key":"1612_CR8","doi-asserted-by":"publisher","unstructured":"Kauw F, Heit JJ, Martin BW, van Ommen F, Kappelle LJ, Velthuis BK, de Jong HWAM, Dankbaar JW, Wintermark M: Computed Tomography Perfusion Data for Acute Ischemic Stroke Evaluation Using Rapid Software: Pitfalls of Automated Postprocessing.\u00a0J Comput Assist Tomogr. https:\/\/doi.org\/10.1097\/RCT.0000000000000946, 2020","DOI":"10.1097\/RCT.0000000000000946"},{"key":"1612_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jstrokecerebrovasdis.2019.104392","volume":"28","author":"Y Xiong","year":"2019","unstructured":"Xiong Y, Huang CC, Fisher M, Hackney DB, Bhadelia RA, Selim MH: Comparison of Automated CT Perfusion Softwares in Evaluation of Acute Ischemic Stroke.\u00a0J Stroke Cerebrovasc Dis 28:104392, 2019","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"1612_CR10","doi-asserted-by":"publisher","first-page":"1401","DOI":"10.2214\/AJR.21.26139","volume":"217","author":"CY Chung","year":"2021","unstructured":"Chung CY, Hu R, Peterson RB, Allen JW: Automated Processing of Head CT Perfusion Imaging for Ischemic Stroke Triage: A Practical Guide to Quality Assurance and Interpretation.\u00a0AJR Am J Roentgenol 217:1401\u20131416, 2021","journal-title":"AJR Am J Roentgenol"},{"key":"1612_CR11","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.10.1.014001","volume":"10","author":"MMS Bhurwani","year":"2023","unstructured":"Bhurwani MMS, Boutelier T, Davis A, Gautier G, Swetz D, Rava RA, Raguenes D, Waqas M, Snyder KV, Siddiqui AH, Ionita CN: Identification of infarct core and ischemic penumbra using computed tomography perfusion and deep learning.\u00a0J Med Imaging 10:014001, 2023","journal-title":"J Med Imaging"},{"key":"1612_CR12","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2023.102749","volume":"85","author":"L de Vries","year":"2023","unstructured":"de Vries L, Emmer BJ, Majoie CBLM, Marquering HA, Gavves E: PerfU-Net: Baseline infarct estimation from CT perfusion source data for acute ischemic stroke.\u00a0Med Image Anal 85:102749, 2023","journal-title":"Med Image Anal"},{"key":"1612_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2022.106630","volume":"215","author":"H Zhu","year":"2022","unstructured":"Zhu H, Chen Y, Tang T, Ma G, Zhou J, Zhang J, Lu S, Wu F, Luo L, Liu S, Ju S, Shi H: ISP-Net: Fusing features to predict ischemic stroke infarct core on CT perfusion maps.\u00a0Comput Methods Programs Biomed 215:106630, 2022","journal-title":"Comput Methods Programs Biomed"},{"key":"1612_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2022.102610","volume":"82","author":"K Amador","year":"2022","unstructured":"Amador K, Wilms M, Winder A, Fiehler J, Forkert ND: Predicting treatment-specific lesion outcomes in acute ischemic stroke from 4D CT perfusion imaging using spatio-temporal convolutional neural networks.\u00a0Med Image Anal 82:102610, 2022","journal-title":"Med Image Anal"},{"key":"1612_CR15","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1007\/s10462-024-11005-9","volume":"58","author":"H Javed","year":"2024","unstructured":"Javed H, El-Sappagh S, Abuhmed T: Robustness in deep learning models for medical diagnostics: security and adversarial challenges towards robust AI applications.\u00a0Artif Intell Rev 58:12, 2024","journal-title":"Artif Intell Rev"},{"key":"1612_CR16","doi-asserted-by":"publisher","first-page":"138936","DOI":"10.1109\/ACCESS.2023.3336590","volume":"11","author":"L Tomasetti","year":"2023","unstructured":"Tomasetti L, Engan K, H\u00f8llesli LJ, Kurz KD, Khanmohammadi M: CT Perfusion is All we Need: 4D CNN Segmentation of Penumbra and Core in Patients With Suspected Acute Ischemic Stroke.\u00a0IEEE Access 11:138936\u2013138953, 2023","journal-title":"IEEE Access"},{"key":"1612_CR17","unstructured":"Ronneberger O, Fischer P, Brox T: U-Net: Convolutional Networks for Biomedical Image Segmentation.\u00a0Available at\u00a0http:\/\/arxiv.org\/abs\/1505.04597. Accessed 19 May 2025"},{"key":"1612_CR18","unstructured":"He K, Zhang X, Ren S, Sun J: Deep Residual Learning for Image Recognition.\u00a0Available at\u00a0http:\/\/arxiv.org\/abs\/1512.03385. Accessed 19 May 2025"},{"key":"1612_CR19","unstructured":"Tan M, Le QV: EfficientNet: Rethinking Model Scaling for Convolutional Neural Networks.\u00a0Available at\u00a0http:\/\/arxiv.org\/abs\/1905.11946. Accessed 19 May 2025"},{"key":"1612_CR20","unstructured":"Chen T, Guestrin C: XGBoost: A Scalable Tree Boosting System.\u00a0Available at\u00a0http:\/\/arxiv.org\/abs\/1603.02754. Accessed 19 May 2025"},{"key":"1612_CR21","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1023\/A:1010933404324","volume":"45","author":"L Breiman","year":"2001","unstructured":"Breiman L: Random Forests.\u00a0Machine Learning 45:5\u201332, 2001","journal-title":"Machine Learning"},{"key":"1612_CR22","unstructured":"Freund Y, Schapire RE: Experiments with a new boosting algorithm.\u00a0Presented at the 13th International Conference on Machine Learning (ICML), Bari, Italy, 3\u20136 July 1996"},{"key":"1612_CR23","doi-asserted-by":"crossref","unstructured":"Ostergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR: High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis.\u00a0Magn Reson Med 36:715\u2013725, 1996","DOI":"10.1002\/mrm.1910360510"},{"key":"1612_CR24","doi-asserted-by":"crossref","unstructured":"de la Rosa E, Robben D, Sima DM, Kirschke JS, Menze B: Differentiable Deconvolution for Improved Stroke Perfusion Analysis.\u00a0In: Martel AL, Abolmaesumi P, Stoyanov D, Mateus D, Zuluaga MA, Zhou SK, Racoceanu D, Joskowicz L (eds): Medical Image Computing and Computer Assisted Intervention \u2013 MICCAI 2020. pp 593\u2013602. Springer International Publishing, Cham, 2020","DOI":"10.1007\/978-3-030-59728-3_58"},{"key":"1612_CR25","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1002\/mrm.10522","volume":"50","author":"O Wu","year":"2003","unstructured":"Wu O, \u00d8stergaard L, Weisskoff RM, Benner T, Rosen BR, Sorensen AG: Tracer arrival timing-insensitive technique for estimating flow in MR perfusion-weighted imaging using singular value decomposition with a block-circulant deconvolution matrix.\u00a0Magn Reson Med 50:164\u2013174, 2003","journal-title":"Magn Reson Med"},{"key":"1612_CR26","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/0146-664X(80)90054-4","volume":"14","author":"PE Danielsson","year":"1980","unstructured":"Danielsson PE: Euclidean distance mapping.\u00a0Comput Graph Image Process 14:227\u2013248, 1980","journal-title":"Comput Graph Image Process"},{"key":"1612_CR27","doi-asserted-by":"publisher","first-page":"255","DOI":"10.2307\/2532051","volume":"45","author":"LI Lin","year":"1989","unstructured":"Lin LI: A Concordance Correlation Coefficient to Evaluate Reproducibility.\u00a0Biometrics 45:255\u2013268, 1989","journal-title":"Biometrics"},{"issue":"9","key":"1612_CR28","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.1002\/(sici)1097-0258(20000515)19:9<1141::aid-sim479>3.0.co;2-f","volume":"19","author":"J Carpenter","year":"2000","unstructured":"Carpenter J, Bithell J: Bootstrap confidence intervals: when, which, what? A practical guide for medical statisticians. Statistics in Medicine. 19(9):1141\u20131164, 2000. https:\/\/doi.org\/10.1002\/(sici)1097-0258(20000515)19:9<1141::aid-sim479>3.0.co;2-f","journal-title":"Statistics in Medicine."},{"key":"1612_CR29","first-page":"2349","volume":"16","author":"J Fox","year":"2002","unstructured":"Fox J: Linear mixed models. Appendix to An R and S-Plus Companion to Applied Regression. 16:2349\u20132380, 2002.","journal-title":"Appendix to An R and S-Plus Companion to Applied Regression."},{"issue":"1","key":"1612_CR30","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1093\/biomet\/73.1.13","volume":"73","author":"KY Liang","year":"1986","unstructured":"Liang KY, Zeger SL: Longitudinal data analysis using generalized linear models. Biometrika. 73(1):13\u201322, 1986. https:\/\/doi.org\/10.1093\/biomet\/73.1.13","journal-title":"Biometrika."},{"key":"1612_CR31","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1067\/j.cpradiol.2023.10.011","volume":"53","author":"H Ladumor","year":"2024","unstructured":"Ladumor H, Vilanilam GK, Ameli S, Pandey I, Vattoth S: CT perfusion in stroke: Comparing conventional and RAPID automated software.\u00a0Curr Probl Diagn Radiol 53:201\u2013207, 2024","journal-title":"Curr Probl Diagn Radiol"},{"key":"1612_CR32","doi-asserted-by":"publisher","first-page":"447","DOI":"10.3390\/diagnostics13030447","volume":"13","author":"B Haggenm\u00fcller","year":"2023","unstructured":"Haggenm\u00fcller B, Kreiser K, Sollmann N, Huber M, Vogele D, Schmidt SA, Beer M, Schmitz B, Ozpeynirci Y, Rosskopf J, Kloth C: Pictorial Review on Imaging Findings in Cerebral CTP in Patients with Acute Stroke and Its Mimics: A Primer for General Radiologists.\u00a0Diagnostics 13:447, 2023","journal-title":"Diagnostics"},{"key":"1612_CR33","doi-asserted-by":"publisher","first-page":"2334","DOI":"10.1016\/j.ejrad.2013.08.039","volume":"82","author":"F Fahmi","year":"2013","unstructured":"Fahmi F, Beenen L, Streekstra G, Janssen N, de Jong H, Riordan A, Roos Y, Majoie C, Marquering H: Head movement during CT brain perfusion acquisition of patients with suspected acute ischemic stroke.\u00a0Eur J Radiol 82:2334\u20132341, 2013","journal-title":"Eur J Radiol"},{"issue":"2","key":"1612_CR34","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1161\/STROKEAHA.114.007117","volume":"46","author":"PW Schaefer","year":"2015","unstructured":"Schaefer PW, Souza L, Kamalian S, Hirsch JA, Yoo AJ, Kamalian S, Lev MH: Limited reliability of computed tomographic perfusion acute infarct volume measurements compared with diffusion-weighted imaging in anterior circulation stroke. Stroke 46(2):419\u2013424, 2015","journal-title":"Stroke"},{"key":"1612_CR35","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1111\/ijs.12068","volume":"10","author":"A Purushotham","year":"2015","unstructured":"Purushotham A, Campbell BC, Straka M, et al. Apparent diffusion coefficient threshold for delineation of ischemic core. Int J Stroke 2015; 10: 348\u2013353. https:\/\/doi.org\/10.1111\/ijs.12068","journal-title":"Int J Stroke"},{"issue":"1","key":"1612_CR36","doi-asserted-by":"publisher","first-page":"46","DOI":"10.3174\/ajnr.A0459","volume":"27","author":"I van der Schaaf","year":"2006","unstructured":"van der Schaaf I, Vonken E-J, Waaijer A, Velthuis B, Quist M, van Osch T: Influence of partial volume on venous output and arterial input function. Am J Neuroradiol. 27(1):46\u201350, 2006. https:\/\/doi.org\/10.3174\/ajnr.A0459","journal-title":"Am J Neuroradiol."},{"issue":"6","key":"1612_CR37","doi-asserted-by":"publisher","first-page":"628","DOI":"10.1136\/neurintsurg-2021-017510","volume":"14","author":"A Potreck","year":"2022","unstructured":"Potreck A, Seker F, Mutke MA, Weyland CS, Herweh C, Heiland S, Bendszus M, M\u00f6hlenbruch M: What is the impact of head movement on automated CT perfusion mismatch evaluation in acute ischemic stroke? J Neurointerv Surg. 14(6):628\u2013633, 2022. https:\/\/doi.org\/10.1136\/neurintsurg-2021-017510","journal-title":"J Neurointerv Surg."},{"issue":"3","key":"1612_CR38","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0283610","volume":"18","author":"E de la Rosa","year":"2023","unstructured":"de la Rosa E, Sima DM, Kirschke JS, Menze B, Robben D: Detecting CTP truncation artifacts in acute stroke imaging from the arterial input and the vascular output functions. PLoS One. 18(3):e0283610, 2023. https:\/\/doi.org\/10.1371\/journal.pone.0283610","journal-title":"PLoS One."}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01612-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01612-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01612-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T09:04:44Z","timestamp":1780391084000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01612-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,27]]},"references-count":38,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["1612"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01612-5","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,27]]},"assertion":[{"value":"11 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board of the Ajou University Hospital [AJOUIRB-DB-2024\u2013219].","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Gi-Youn Kim, Hyeon Sik Yang, Jundong Hwang, Kijeong Lee, Regina Eun Yuoung Kim Donghyeon Kim, and Minho Lee were employed by the company Neurophet Inc. (Seoul, Republic of Korea). Jin Wook Choi and Woo Sang Jung participated as advisory professors in the study. The remaining author declares that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}