{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T10:06:03Z","timestamp":1780394763082,"version":"3.54.1"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T00:00:00Z","timestamp":1756252800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T00:00:00Z","timestamp":1756252800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Federal Ministry of Education and Research (BMBF) and the Free State of Bavaria","award":["GRK2274"],"award-info":[{"award-number":["GRK2274"]}]},{"name":"Technical University of Munich\u2013Institute for Advanced Study"},{"DOI":"10.13039\/501100005713","name":"Technische Universit\u00e4t M\u00fcnchen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005713","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This retrospective study evaluates U-Net-based artifact reduction for dose-reduced sparse-sampling CT (SpSCT) in terms of image quality and diagnostic performance using a reader study and automated detection. CT pulmonary angiograms from 89 patients were used to generate SpSCT data with 16 to 512 views. Twenty patients were reserved for a reader study and test set, the remaining 69 were used to train (53) and validate (16) a dual-frame U-Net for artifact reduction. U-Net post-processed images were assessed for image quality, diagnostic performance, and automated pulmonary embolism (PE) detection using the top-performing network from the 2020 RSNA PE detection challenge. Statistical comparisons were made using two-sided Wilcoxon signed-rank and DeLong two-sided tests. Post-processing with the dual-frame U-Net significantly improved image quality in the internal test set, with a structural similarity index of 0.634\/0.378\/0.234\/0.152 for FBP and 0.894\/0.892\/0.866\/0.778 for U-Net at 128\/64\/32\/16 views, respectively. The reader study showed significantly enhanced image quality (3.15 vs. 3.53 for 256 views, 0.00 vs. 2.52 for 32 views), increased diagnostic confidence (0.00 vs. 2.38 for 32 views), and fewer artifacts across all subsets (\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&lt;\u20090.05). Diagnostic performance, measured by the S\u00f8rensen\u2013Dice coefficient, was significantly better for 64- and 32-view images (0.23 vs. 0.44 and 0.00 vs. 0.09,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&lt;\u20090.05). Automated PE detection was better at fewer views (64 views: 0.77 vs. 0.80, 16 views: 0.59 vs. 0.80), although the differences were not statistically significant. U-Net-based post-processing of SpSCT data significantly enhances image quality and diagnostic performance, supporting substantial dose reduction in CT pulmonary angiography.\n                  <\/jats:p>","DOI":"10.1007\/s10278-025-01639-8","type":"journal-article","created":{"date-parts":[[2025,8,27]],"date-time":"2025-08-27T19:27:15Z","timestamp":1756322835000},"page":"2593-2605","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Ultra-Low-Dose CTPA Using Sparse Sampling CT Combined with the U-Net for Deep Learning-Based Artifact Reduction: An Exploratory Study"],"prefix":"10.1007","volume":"39","author":[{"given":"Andreas Philipp","family":"Sauter","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5198-8571","authenticated-orcid":false,"given":"Johannes","family":"Thalhammer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Meurer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tina","family":"Dorosti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Sasse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Ritter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yannik","family":"Leonhardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Franz","family":"Pfeiffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Schaff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Pfeiffer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,27]]},"reference":[{"key":"1639_CR1","doi-asserted-by":"crossref","unstructured":"Goldhaber S, Deep Venous Thrombosis and Pulmonary Embolism, New York: 2012","DOI":"10.1016\/B978-1-4557-2296-9.00016-6"},{"key":"1639_CR2","unstructured":"Wood KE, An approach to Venous Thomboembolism\/Pulmonay Embolism in the Critically Ill, Lippincott Williams & Wilkins., 2002"},{"key":"1639_CR3","doi-asserted-by":"crossref","unstructured":"Estrada YMRM and Oldham SA: CTPA as the gold standard for the diagnosis of pulmonary embolism. Int. J. Comput. Assist. Radiol. Surg., 6:557-63, 2011","DOI":"10.1007\/s11548-010-0526-4"},{"key":"1639_CR4","doi-asserted-by":"crossref","unstructured":"Remy-Jardin M, Remy J, Baghaie F, Fribourg M, Artaud D, and Duhamel A: Clinical value of thin collimation in the diagnostic workup of pulmonary embolism. AJR Am. J. Roentgenol., 175:407-11, 2000","DOI":"10.2214\/ajr.175.2.1750407"},{"key":"1639_CR5","doi-asserted-by":"crossref","unstructured":"Stein PD, Fowler SE, Goodman LR, Gottschalk A, Hales CA, Hull RD, Leeper KV, Jr., Popovich J, Jr., Quinn DA, Sos TA, Sostman HD, Tapson VF, Wakefield TW, Weg JG, and Woodard PK: Multidetector computed tomography for acute pulmonary embolism. The New England journal of medicine, 354:2317-27, 2006","DOI":"10.1056\/NEJMoa052367"},{"key":"1639_CR6","doi-asserted-by":"crossref","unstructured":"Phillips JJ, Straiton J, and Staff RT: Planar and SPECT ventilation\/perfusion imaging and computed tomography for the diagnosis of pulmonary embolism: A systematic review and meta-analysis of the literature, and cost and dose comparison. Eur. J. Radiol., 84:1392-400, 2015","DOI":"10.1016\/j.ejrad.2015.03.013"},{"key":"1639_CR7","doi-asserted-by":"crossref","unstructured":"Mahesh M, Ansari AJ, and Mettler FA, Jr.: Patient Exposure from Radiologic and Nuclear Medicine Procedures in the United States and Worldwide: 2009-2018. Radiology, 307:e221263, 2023","DOI":"10.1148\/radiol.239006"},{"key":"1639_CR8","doi-asserted-by":"crossref","unstructured":"Brenner DJ and Hall EJ: Computed tomography--an increasing source of radiation exposure. N. Engl. J. Med., 357:2277-84, 2007","DOI":"10.1056\/NEJMra072149"},{"key":"1639_CR9","doi-asserted-by":"crossref","unstructured":"Berrington de Gonzalez A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, and Land C: Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch. Intern. Med., 169:2071\u20137, 2009","DOI":"10.1001\/archinternmed.2009.440"},{"key":"1639_CR10","doi-asserted-by":"crossref","unstructured":"Faggioni L, Neri E, Sbragia P, Pascale R, D\u2019Errico L, Caramella D, and Bartolozzi C: 80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I\/mL)and iomeprol (400 mg I\/mL). AJR Am. J. Roentgenol., 199:1220-5, 2012","DOI":"10.2214\/AJR.11.8122"},{"key":"1639_CR11","doi-asserted-by":"crossref","unstructured":"Szucs-Farkas Z, Megyeri B, Christe A, Vock P, Heverhagen JT, and Schindera ST: Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights. Eur. Radiol., 24:1868-77, 2014","DOI":"10.1007\/s00330-014-3208-8"},{"key":"1639_CR12","doi-asserted-by":"crossref","unstructured":"Bellizzi A, Bezzina P, and Zarb F: Optimisation of the CT pulmonary angiogram (CTPA) protocol using a low kV technique combined with high iterative reconstruction (IR): A phantom study. Radiography, 29:313-318, 2023","DOI":"10.1016\/j.radi.2022.11.011"},{"key":"1639_CR13","doi-asserted-by":"crossref","unstructured":"Willemink MJ, Leiner T, de Jong PA, de Heer LM, Nievelstein RA, Schilham AM, and Budde RP: Iterative reconstruction techniques for computed tomography part 2: initial results in dose reduction and image quality. Eur. Radiol., 23:1632-1642, 2013","DOI":"10.1007\/s00330-012-2764-z"},{"key":"1639_CR14","doi-asserted-by":"crossref","unstructured":"Sauter A, Koehler T, Fingerle AA, Brendel B, Richter V, Rasper M, Rummeny EJ, Noel PB, and Munzel D: Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction. PLoS One, 11:e0162716, 2016","DOI":"10.1371\/journal.pone.0162716"},{"key":"1639_CR15","doi-asserted-by":"crossref","unstructured":"Sauter AP, Kopp FK, Bippus R, Dangelmaier J, Deniffel D, Fingerle AA, Meurer F, Pfeiffer D, Proksa R, Rummeny EJ, and Noel PB: Sparse sampling computed tomography (SpSCT) for detection of pulmonary embolism: a feasibility study. Eur. Radiol., 29:5950-5960, 2019","DOI":"10.1007\/s00330-019-06217-5"},{"key":"1639_CR16","doi-asserted-by":"crossref","unstructured":"Kopp FK, Bippus R, Sauter AP, Muenzel D, Bergner F, Mei K, Dangelmaier J, Schwaiger BJ, Catalano M, Fingerle AA, Rummeny EJ, and No\u00ebl PB: Diagnostic value of sparse sampling computed tomography for radiation dose reduction: initial results. SPIE Medical Imaging, 10573:6, 2018","DOI":"10.1117\/12.2293529"},{"key":"1639_CR17","doi-asserted-by":"crossref","unstructured":"Zhang Z, Liang X, Dong X, Xie Y, and Cao G: A sparse-view CT reconstruction method based on combination of DenseNet and deconvolution. IEEE Trans. Med. Imaging, 37:1407-1417, 2018","DOI":"10.1109\/TMI.2018.2823338"},{"key":"1639_CR18","doi-asserted-by":"crossref","unstructured":"Jin KH, McCann MT, Froustey E, and Unser M: Deep convolutional neural network for inverse problems in imaging. IEEE transactions on image processing, 26:4509-4522, 2017","DOI":"10.1109\/TIP.2017.2713099"},{"key":"1639_CR19","doi-asserted-by":"crossref","unstructured":"Thalhammer J, Schulthei\u00df M, Dorosti T, Lasser T, Pfeiffer F, Pfeiffer D, and Schaff F: Improving Automated Hemorrhage Detection at Sparse-View CT via U-Net\u2013based Artifact Reduction. Radiology: Artificial Intelligence, 6:e230275, 2024.","DOI":"10.1148\/ryai.230275"},{"key":"1639_CR20","doi-asserted-by":"crossref","unstructured":"He K, Zhang X, Ren S, and Sun J: Deep Residual Learning for Image Recognition. 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), 770\u2013778, 2016","DOI":"10.1109\/CVPR.2016.90"},{"key":"1639_CR21","doi-asserted-by":"crossref","unstructured":"Ronneberger O, Fischer P, and Brox T: U-Net: Convolutional Networks for Biomedical Image Segmentation. 234\u2013241, 2015","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"1639_CR22","doi-asserted-by":"crossref","unstructured":"Han Y and Ye JC: Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT. IEEE Trans. Med. Imaging, 37:1418-1429, 2018","DOI":"10.1109\/TMI.2018.2823768"},{"key":"1639_CR23","doi-asserted-by":"crossref","unstructured":"Ries A, Dorosti T, Thalhammer J, Sasse D, Sauter A, Meurer F, Benne A, Lasser T, Pfeiffer F, Schaff F, and Pfeiffer D: Improving image quality of sparse-view lung tumor CT images with U-Net. Eur Radiol Exp, 8:54, 2024","DOI":"10.1186\/s41747-024-00450-4"},{"key":"1639_CR24","doi-asserted-by":"crossref","unstructured":"Lee H, Lee J, Kim H, Cho B, and Cho S: Deep-Neural-Network-Based Sinogram Synthesis for Sparse-View CT Image Reconstruction. IEEE Transactions on Radiation and Plasma Medical Sciences, 3:109-119, 2019","DOI":"10.1109\/TRPMS.2018.2867611"},{"key":"1639_CR25","doi-asserted-by":"crossref","unstructured":"Cheslerean-Boghiu T, Hofmann FC, Schulthei\u00df M, Pfeiffer F, Pfeiffer D, and Lasser T: Wnet: A data-driven dual-domain denoising model for sparse-view computed tomography with a trainable reconstruction layer. IEEE Transactions on Computational Imaging, 9:120-132, 2023","DOI":"10.1109\/TCI.2023.3240078"},{"key":"1639_CR26","doi-asserted-by":"crossref","unstructured":"Pan J, Zhang H, Wu W, Gao Z, and Wu W: Multi-domain integrative Swin transformer network for sparse-view tomographic reconstruction. Patterns, 3:100498, 2022","DOI":"10.1016\/j.patter.2022.100498"},{"key":"1639_CR27","unstructured":"Genzel M, G\u00fchring I, Macdonald J, and M\u00e4rz M: Near-exact recovery for tomographic inverse problems via deep learning. International Conference on Machine Learning, 7368\u20137381, 2022"},{"key":"1639_CR28","doi-asserted-by":"crossref","unstructured":"Pan J, Yu H, Gao Z, Wang S, Zhang H, and Wu W: Iterative Residual Optimization Network for Limited-Angle Tomographic Reconstruction. IEEE Transactions on Image Processing, 33:910-925, 2024","DOI":"10.1109\/TIP.2024.3351382"},{"key":"1639_CR29","doi-asserted-by":"crossref","unstructured":"Chen G, Hong X, Ding Q, Zhang Y, Chen H, Fu S, Zhao Y, Zhang X, Ji H, Wang G, Huang Q, and Gao H: AirNet: Fused analytical and iterative reconstruction with deep neural network regularization for sparse-data CT. Med. Phys., 47:2916-2930, 2020","DOI":"10.1002\/mp.14170"},{"key":"1639_CR30","doi-asserted-by":"crossref","unstructured":"Wu W, Hu D, Niu C, Yu H, Vardhanabhuti V, and Wang G: DRONE: Dual-Domain Residual-based Optimization NEtwork for Sparse-View CT Reconstruction. IEEE Trans. Med. Imaging, 40:3002-3014, 2021","DOI":"10.1109\/TMI.2021.3078067"},{"key":"1639_CR31","doi-asserted-by":"crossref","unstructured":"Zhou L, Fang C, Morovati B, Liu Y, Han S, Xu Y, and Yu H: $\\rho $-NeRF: Leveraging Attenuation Priors in Neural Radiance Field for 3D Computed Tomography Reconstruction. arXiv preprint arXiv:2412.05322, 2024","DOI":"10.32388\/ZX6D29"},{"key":"1639_CR32","unstructured":"Zha R, Lin TJ, Cai Y, Cao J, Zhang Y, and Li H: R $^ 2$-Gaussian: Rectifying Radiative Gaussian Splatting for Tomographic Reconstruction. arXiv preprint arXiv:2405.20693, 2024"},{"key":"1639_CR33","doi-asserted-by":"crossref","unstructured":"Li S, Jiang X, Tivnan M, Gang GJ, Shen Y, and Stayman JW: CT reconstruction using diffusion posterior sampling conditioned on a nonlinear measurement model. Journal of Medical Imaging, 11:043504-043504, 2024","DOI":"10.1117\/1.JMI.11.4.043504"},{"key":"1639_CR34","doi-asserted-by":"crossref","unstructured":"Eulig E, Ommer B, and Kachelrie\u00df M: Benchmarking deep learning-based low-dose CT image denoising algorithms. Med. Phys., 51:8776-8788, 2024","DOI":"10.1002\/mp.17379"},{"key":"1639_CR35","doi-asserted-by":"crossref","unstructured":"Sauter A, Koehler T, Brendel B, Aichele J, Neumann J, Noel PB, Rummeny EJ, and Muenzel D: CT pulmonary angiography: dose reduction via a next generation iterative reconstruction algorithm. Acta Radiol., 60:478-487, 2019","DOI":"10.1177\/0284185118784976"},{"key":"1639_CR36","unstructured":"Guanshuo and Xu, RSNA-STR-Pulmonary-Embolism-Detection."},{"key":"1639_CR37","doi-asserted-by":"crossref","unstructured":"Xie S, Girshick R, Doll\u00e1r P, Tu Z, and He K: Aggregated residual transformations for deep neural networks. Proceedings of the IEEE conference on computer vision and pattern recognition, 1492\u20131500, 2017","DOI":"10.1109\/CVPR.2017.634"},{"key":"1639_CR38","doi-asserted-by":"crossref","unstructured":"Dice LR: Measures of the Amount of Ecologic Association Between Species. Ecology, 26:297-302, 1945","DOI":"10.2307\/1932409"},{"key":"1639_CR39","doi-asserted-by":"crossref","unstructured":"DeLong ER, DeLong DM, and Clarke-Pearson DL: Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics, 44:837-45, 1988","DOI":"10.2307\/2531595"},{"key":"1639_CR40","doi-asserted-by":"crossref","unstructured":"Sun X and Xu W: Fast Implementation of DeLong\u2019s Algorithm for Comparing the Areas Under Correlated Receiver Operating Characteristic Curves. IEEE Signal Processing Letters, 21:1389-1393, 2014","DOI":"10.1109\/LSP.2014.2337313"},{"key":"1639_CR41","doi-asserted-by":"crossref","unstructured":"Verdun FR, Racine D, Ott JG, Tapiovaara MJ, Toroi P, Bochud FO, Veldkamp WJH, Schegerer A, Bouwman RW, Giron IH, Marshall NW, and Edyvean S: Image quality in CT: From physical measurements to model observers. Phys. Med., 31:823-843, 2015","DOI":"10.1016\/j.ejmp.2015.08.007"},{"key":"1639_CR42","doi-asserted-by":"crossref","unstructured":"Meurer F, Kopp F, Renz M, Harder FN, Leonhardt Y, Bippus R, Noel PB, Makowski MR, and Sauter AP: Sparse-sampling computed tomography for detection of endoleak after endovascular aortic repair (EVAR). Eur. J. Radiol., 142:109843, 2021","DOI":"10.1016\/j.ejrad.2021.109843"},{"key":"1639_CR43","doi-asserted-by":"crossref","unstructured":"Zhang Z and Seeram E: The use of artificial intelligence in computed tomography image reconstruction - A literature review. J Med Imaging Radiat Sci, 51:671-677, 2020","DOI":"10.1016\/j.jmir.2020.09.001"},{"key":"1639_CR44","doi-asserted-by":"crossref","unstructured":"Soffer S, Klang E, Shimon O, Barash Y, Cahan N, Greenspana H, and Konen E: Deep learning for pulmonary embolism detection on computed tomography pulmonary angiogram: a systematic review and meta-analysis. Sci. Rep., 11:15814, 2021","DOI":"10.1038\/s41598-021-95249-3"},{"key":"1639_CR45","doi-asserted-by":"crossref","unstructured":"Grenier PA, Ayobi A, Quenet S, Tassy M, Marx M, Chow DS, Weinberg BD, Chang PD, and Chaibi Y: Deep Learning-Based Algorithm for Automatic Detection of Pulmonary Embolism in Chest CT Angiograms. Diagnostics, 13:1324, 2023","DOI":"10.3390\/diagnostics13071324"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01639-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01639-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01639-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T09:06:12Z","timestamp":1780391172000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01639-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,27]]},"references-count":45,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["1639"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01639-8","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,27]]},"assertion":[{"value":"22 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 July 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}