{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T19:57:23Z","timestamp":1780430243966,"version":"3.54.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T00:00:00Z","timestamp":1757289600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T00:00:00Z","timestamp":1757289600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Digit Imaging. Inform. med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>With the increasing shift towards remote radiology work, institutions face the challenge of balancing cost-effectiveness with operational reliability. This experiential report presents a comparative analysis of the total cost of ownership (TCO) of commercial-grade displays (WCDs) and diagnostic-grade displays (WDDs) in remote diagnostic stations. We evaluate direct and indirect costs associated with each display type using activity-based costing, focusing on deployment, quality control (QC) processes, and ongoing maintenance. Our findings suggest that while CGDs offer significant initial cost savings, their long-term maintenance requirements, particularly in manual QC, increase recurring expenses. The crossover point for CGDs with monthly QC occurs at approximately five years against mid-level DGDs, potentially making DGDs a more sustainable option over time.<\/jats:p>","DOI":"10.1007\/s10278-025-01651-y","type":"journal-article","created":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T18:51:57Z","timestamp":1757357517000},"page":"1972-1985","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparative Analysis of Total Cost of Ownership: Commercial-Grade versus Diagnostic-Grade Displays in Remote Radiology Workstations"],"prefix":"10.1007","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-7541-6894","authenticated-orcid":false,"given":"Katie","family":"Hulme","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Arnold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-3686-5878","authenticated-orcid":false,"given":"Ryan","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roy","family":"Kittelberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6456-9453","authenticated-orcid":false,"given":"Namita","family":"Gandhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1286-491X","authenticated-orcid":false,"given":"Douglas","family":"Nachand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7698-5289","authenticated-orcid":false,"given":"Po-Hao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,8]]},"reference":[{"key":"1651_CR1","doi-asserted-by":"crossref","unstructured":"Callaway M, Greenhalgh R, Harden S, Elford J, Drinkwater K, Vanburen T, et al. Accelerated implementation of remote reporting during the COVID-19 pandemic. ClinRadiol. 2021 Jun;76(6):443\u20136.","DOI":"10.1016\/j.crad.2021.01.004"},{"key":"1651_CR2","doi-asserted-by":"crossref","unstructured":"Tridandapani S, Holl G, Canon CL. Rapid Deployment of Home PACS Workstations to Enable Social Distancing in the Coronavirus Disease (COVID-19) Era. American Journal of Roentgenology. 2020 Dec;215(6):1351\u20133.","DOI":"10.2214\/AJR.20.23495"},{"key":"1651_CR3","doi-asserted-by":"crossref","unstructured":"Chen SZ, Kapral N, Dueck N, Gaskin CM, Bueno J, Hanley M. TeleResidents: Exploring the use of Resident Home Workstations During the COVID Pandemic. Academic Radiology. 2022 Mar;29(3):450\u20135.","DOI":"10.1016\/j.acra.2021.11.001"},{"key":"1651_CR4","doi-asserted-by":"crossref","unstructured":"Bevins N, Flynn M, Silosky M, Marsh R, Walz-Flannigan A, Badano A. Report No. 270 - Display Quality Assurance [Internet]. AAPM; 2019 Jan [cited 2025 Jan 12]. Report No.: TG 270. Available from: https:\/\/www.aapm.org\/pubs\/reports\/detail.asp?docid=183","DOI":"10.37206\/183"},{"key":"1651_CR5","unstructured":"American College of Radiology. ACR\u2013AAPM\u2013SIIM Technical Standard for Electronic Practice of Medical Imaging [Internet]. 2022. Available from: https:\/\/gravitas.acr.org\/PPTS\/GetDocumentView?docId=136+&releaseId=2"},{"key":"1651_CR6","unstructured":"American College of Radiology. ACR\u2013AAPM Technical Standard for Diagnostic Interpretation Displays [Internet]. 2024. Available from: https:\/\/gravitas.acr.org\/PPTS\/GetDocumentView?docId=59+&releaseId=2"},{"key":"1651_CR7","doi-asserted-by":"crossref","unstructured":"Krupinski EA, Roehrig H. The influence of a perceptually linearized display on observer performance and visual search. Academic Radiology. 2000 Jan 1;7(1):8\u201313.","DOI":"10.1016\/S1076-6332(00)80437-7"},{"key":"1651_CR8","doi-asserted-by":"crossref","unstructured":"Fetterly KA, Blume HR, Flynn MJ, Samei E. Introduction to Grayscale Calibration and Related Aspects of Medical Imaging Grade Liquid Crystal Displays. J Digit Imaging. 2008 Jun 1;21(2):193\u2013207.","DOI":"10.1007\/s10278-007-9022-y"},{"key":"1651_CR9","doi-asserted-by":"crossref","unstructured":"Chawla AS, Samei E. Ambient illumination revisited: a new adaptation-based approach for optimizing medical imaging reading environments. Med Phys. 2007 Jan;34(1):81\u201390.","DOI":"10.1118\/1.2402583"},{"key":"1651_CR10","doi-asserted-by":"crossref","unstructured":"Ikushima Y, Yabuuchi H, Morishita J, Honda H. Analysis of Dominant Factors Affecting Fatigue Caused by Soft-Copy Reading. Academic Radiology. 2013 Nov 1;20(11):1448\u201356.","DOI":"10.1016\/j.acra.2013.08.013"},{"key":"1651_CR11","unstructured":"Food and Drug Administration. Mammography Quality Standards Act [Internet]. Available from: https:\/\/www.federalregister.gov\/documents\/2023\/03\/10\/2023-04550\/mammography-quality-standards-act"},{"key":"1651_CR12","doi-asserted-by":"crossref","unstructured":"Krupinski EA. Medical grade vs off-the-shelf color displays: influence on observer performance and visual search. J Digit Imaging. 2009 Aug;22(4):363\u20138.","DOI":"10.1007\/s10278-008-9156-6"},{"key":"1651_CR13","doi-asserted-by":"crossref","unstructured":"Laffranchi A, Cicero C, Lualdi M, Ciniselli CM, Calareso G, Canestrini S, et al. Different pixel pitch and maximum luminance of medical grade displays may result in different evaluations of digital radiography images. Radiol Med. 2018 Aug;123(8):586\u201392.","DOI":"10.1007\/s11547-018-0891-6"},{"key":"1651_CR14","doi-asserted-by":"crossref","unstructured":"Pinto Dos Santos D, Welter J, Emrich T, Jungmann F, Dappa E, Mildenberger P, et al. Comparison of medical-grade and calibrated consumer-grade displays for diagnosis of subtle bone fissures. Eur Radiol. 2017 Dec;27(12):5049\u201355.","DOI":"10.1007\/s00330-017-4923-8"},{"key":"1651_CR15","doi-asserted-by":"crossref","unstructured":"Hulme K, Arnold J, Thomas R, Gandhi N, Kittelberger R, McDaniel M, et al. Dollars and Displays: An activity-based costing approach to assessing the total cost of ownership of commercial-grade displays versus diagnostic-grade displays for remote diagnostic stations. In 2024.","DOI":"10.1007\/s10278-025-01651-y"},{"key":"1651_CR16","unstructured":"Hulme K, Arnold J, Thomas R, Nachand D, Chen PH. Display or dismay? Initial experience in deploying 52 workstations with consumer-grade displays for remote diagnostic workstations. In Portland, OR; 2025."},{"key":"1651_CR17","doi-asserted-by":"crossref","unstructured":"Arenson RL, Chakraborty DP, Seshadri SB, Kundel HL. The Digital Imaging Workstation. Journal of Digital Imaging. 2003 Mar 1;16(1):142\u201362.","DOI":"10.1007\/s10278-002-6004-y"},{"key":"1651_CR18","doi-asserted-by":"crossref","unstructured":"Nagy P, Siegel E, Hanson T, Kreiner L, Johnson K, Reiner B. PACS reading room design. SeminRoentgenol. 2003 Jul;38(3):244\u201355.","DOI":"10.1016\/S0037-198X(03)00049-X"},{"key":"1651_CR19","doi-asserted-by":"publisher","unstructured":"Pezzotta G, Pezzotta G, Dovere E, Pirola F, Gaiardelli P. Using Total Cost of Ownership to Compare Supplier Product-Service System Offering. In: Liyanage JP, Amadi-Echendu J, Mathew J, editors. Engineering Assets and Public Infrastructures in the Age of Digitalization [Internet]. Cham: Springer International Publishing; 2020 [cited 2025 Feb 20]. p. 183\u201391. (Lecture Notes in Mechanical Engineering). Available from: http:\/\/link.springer.com\/https:\/\/doi.org\/10.1007\/978-3-030-48021-9_21","DOI":"10.1007\/978-3-030-48021-9_21"},{"key":"1651_CR20","unstructured":"Hulme K, Thomas R, Nachand D, Gandhi N, Chen PH. Let\u2019s Not \u201cPlug and Pray\u201d - Long-Term Tradeoffs of Consumer-Grade Displays in Diagnostic Use Compared to Medical-Grade Displays. In 2022."},{"key":"1651_CR21","unstructured":"U.S. Bureau of Labor Statistics. Occupational Employment and Wage Statistics [Internet]. [cited 2024 Apr 28]. Available from: https:\/\/www.bls.gov\/oes\/"},{"key":"1651_CR22","unstructured":"Current US Inflation Rates: 2000\u20132025 [Internet]. [cited 2025 Feb 21]. Available from: https:\/\/www.usinflationcalculator.com\/inflation\/current-inflation-rates\/"},{"key":"1651_CR23","doi-asserted-by":"crossref","unstructured":"Robinson A, Fairchild MD. Comparing medical grade to commercial grade display in a radiation oncology environment.Medical Dosimetry. 2020;45(2):111\u20136.","DOI":"10.1016\/j.meddos.2019.07.005"}],"container-title":["Journal of Imaging Informatics in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01651-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10278-025-01651-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10278-025-01651-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T09:08:46Z","timestamp":1780391326000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10278-025-01651-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,8]]},"references-count":23,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,6]]}},"alternative-id":["1651"],"URL":"https:\/\/doi.org\/10.1007\/s10278-025-01651-y","relation":{},"ISSN":["2948-2933"],"issn-type":[{"value":"2948-2933","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,8]]},"assertion":[{"value":"16 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 September 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}]}}