{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T03:45:49Z","timestamp":1774496749699,"version":"3.50.1"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,6,20]],"date-time":"2017-06-20T00:00:00Z","timestamp":1497916800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100004963","name":"Seventh Framework Programme (BE)","doi-asserted-by":"publisher","award":["PIRG-GA-2010-268455"],"award-info":[{"award-number":["PIRG-GA-2010-268455"]}],"id":[{"id":"10.13039\/501100004963","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004963","name":"Seventh Framework Programme (BE)","doi-asserted-by":"publisher","award":["PIRG-GA-2010-268426"],"award-info":[{"award-number":["PIRG-GA-2010-268426"]}],"id":[{"id":"10.13039\/501100004963","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Ann Oper Res"],"published-print":{"date-parts":[[2018,3]]},"DOI":"10.1007\/s10479-017-2557-5","type":"journal-article","created":{"date-parts":[[2017,6,20]],"date-time":"2017-06-20T04:49:42Z","timestamp":1497934182000},"page":"153-184","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Photovoltaic power plant design considering multiple uncertainties and risk"],"prefix":"10.1007","volume":"262","author":[{"given":"Yasemin","family":"Merzifonluoglu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0546-0252","authenticated-orcid":false,"given":"Eray","family":"Uzgoren","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,6,20]]},"reference":[{"issue":"3","key":"2557_CR1","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1109\/TIA.2007.895768","volume":"43","author":"C Abbey","year":"2007","unstructured":"Abbey, C., & Joos, G. (2007). Supercapacitor energy storage for wind energy applications. IEEE Transactions on Industry Applications, 43(3), 769\u2013776.","journal-title":"IEEE Transactions on Industry Applications"},{"key":"2557_CR2","unstructured":"AES. (2015). http:\/\/aessolar.com\/Resources\/battery_info.htm . Accessed October 10, 2016."},{"key":"2557_CR3","unstructured":"Ali, S. M. H. (2015). Optimal photovoltaic size estimation for a campus area considering uncertainties in load, power generation and electricity rates. Thesis. Middle East Technical University."},{"key":"2557_CR4","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.enconman.2014.04.089","volume":"86","author":"M Bortolini","year":"2014","unstructured":"Bortolini, M., Gamberi, M., & Graziani, A. (2014). Technical and economic design of photovoltaic and battery energy storage system. Energy Conversion and Management, 86, 81\u201392.","journal-title":"Energy Conversion and Management"},{"key":"2557_CR5","unstructured":"Bower, W. (2002). IEA, International guideline for the certification of photovoltaic system components and grid-connected systems. http:\/\/www.iea-pvps.org\/index.php?id=9&eID=dam_frontend_push&docID=383 . Accessed August 28, 2015"},{"issue":"2","key":"2557_CR6","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1109\/TPWRS.2008.919419","volume":"23","author":"PD Brown","year":"2008","unstructured":"Brown, P. D., Lopes, J. A. P., & Matos, M. A. (2008). Optimization of pumped storage capacity in an isolated power system with large renewable penetration. IEEE Transactions on Power Systems, 23(2), 523\u2013531.","journal-title":"IEEE Transactions on Power Systems"},{"key":"2557_CR7","unstructured":"CAE. (2015). http:\/\/www.cleanenergyauthority.com\/solar-energy-resources\/solar-pv-warranty\/ . Accessed October 10, 2016."},{"key":"2557_CR8","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4419-7421-1","volume-title":"Decision making under uncertainty in electricity markets","author":"AJ Conejo","year":"2010","unstructured":"Conejo, A. J., Carri\u00f3n, M., & Morales, J. M. (2010). Decision making under uncertainty in electricity markets. New York, NY: Springer."},{"key":"2557_CR9","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.measurement.2013.11.032","volume":"49","author":"MZ Daud","year":"2014","unstructured":"Daud, M. Z., Mohamed, A., Ibrahim, A. A., & Hannan, M. A. (2014). Heuristic optimization of state-of-charge feedback controller parameters for output power dispatch of hybrid photovoltaic\/battery energy storage system. Measurement, 49, 15\u201325.","journal-title":"Measurement"},{"issue":"2","key":"2557_CR10","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/j.apenergy.2009.05.022","volume":"87","author":"O Ekren","year":"2010","unstructured":"Ekren, O., & Ekren, B. Y. (2010). Size optimization of a PV\/wind hybrid energy conversion system with battery storage using simulated annealing. Applied Energy, 87(2), 592\u2013598.","journal-title":"Applied Energy"},{"key":"2557_CR11","unstructured":"Elhodeiby, A. S., Metwally, H. M. B., & Farahat, M. A. (2011). Performance analysis of 3.6 KW rooftop grid connected photovoltaic system in Egypt. In International conference on energy systems and technologies (Vol. 11, p. 14)."},{"issue":"4","key":"2557_CR12","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/0038-092X(82)90302-4","volume":"28","author":"DG Erbs","year":"1982","unstructured":"Erbs, D. G., Klein, S. A., & Duffie, J. A. (1982). Estimation of the diffuse radiation fraction for hourly, daily and monthly-average global radiation. Solar Energy, 28(4), 293\u2013302.","journal-title":"Solar Energy"},{"key":"2557_CR13","unstructured":"IEA. (2016). https:\/\/www.iea.org\/topics\/renewables\/ . Accessed October 10, 2016."},{"issue":"4","key":"2557_CR14","doi-asserted-by":"crossref","first-page":"1852","DOI":"10.1109\/TPWRS.2005.856952","volume":"20","author":"R Jabr","year":"2005","unstructured":"Jabr, R. (2005). Robust self-scheduling under price uncertainty using conditional value-at-risk. IEEE Transactions on Power Systems, 20(4), 1852\u20131858.","journal-title":"IEEE Transactions on Power Systems"},{"issue":"1","key":"2557_CR15","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1002\/pip.1182","volume":"21","author":"DC Jordan","year":"2013","unstructured":"Jordan, D. C., & Kurtz, S. R. (2013). Photovoltaic degradation rates\u2014An analytical review. Progress in photovoltaics: Research and Applications, 21(1), 12\u201329.","journal-title":"Progress in photovoltaics: Research and Applications"},{"issue":"5","key":"2557_CR16","first-page":"1241","volume":"10","author":"YA Katsigiannis","year":"2008","unstructured":"Katsigiannis, Y. A., & Georgilakis, P. S. (2008). Optimal sizing of small isolated hybrid power systems using tabu search. Journal of Optoelectronics and Advanced Materials, 10(5), 1241.","journal-title":"Journal of Optoelectronics and Advanced Materials"},{"issue":"1","key":"2557_CR17","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s10479-012-1110-9","volume":"210","author":"L Kuznia","year":"2013","unstructured":"Kuznia, L., Zeng, B., Centeno, G., & Miao, Z. (2013). Stochastic optimization for power system configuration with renewable energy in remote areas. Annals of Operations Research, 210(1), 411\u2013432.","journal-title":"Annals of Operations Research"},{"key":"2557_CR18","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1016\/j.apenergy.2014.09.081","volume":"137","author":"X Luo","year":"2015","unstructured":"Luo, X., Wang, J., Dooner, M., & Clarke, J. (2015). Overview of current development in electrical energy storage technologies and the application potential in power system operation. Applied Energy, 137, 511\u2013536.","journal-title":"Applied Energy"},{"issue":"22","key":"2557_CR19","doi-asserted-by":"crossref","first-page":"6937","DOI":"10.1080\/00207543.2014.999956","volume":"53","author":"Y Merzifonluoglu","year":"2015","unstructured":"Merzifonluoglu, Y. (2015). Impact of risk aversion and backup supplier on sourcing decisions of a firm. International Journal of Production Research, 53(22), 6937\u20136961.","journal-title":"International Journal of Production Research"},{"key":"2557_CR20","doi-asserted-by":"crossref","DOI":"10.2172\/1088066","volume-title":"The comparison of three photovoltaic system designs using the photovoltaic reliability and performance model (PV-RPM) (No. SAND2012-10342)","author":"SP Miller","year":"2012","unstructured":"Miller, S. P., Granata, J. E., & Stein, J. S. (2012). The comparison of three photovoltaic system designs using the photovoltaic reliability and performance model (PV-RPM) (No. SAND2012-10342). Albuquerque, NM: Sandia National Laboratories (SNL-NM)."},{"issue":"1","key":"2557_CR21","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1137\/S1052623400375075","volume":"13","author":"W Ogryczak","year":"2002","unstructured":"Ogryczak, W., & Ruszczynski, A. (2002). Dual stochastic dominance and related mean-risk models. SIAM Journal on Optimization, 13(1), 60\u201378.","journal-title":"SIAM Journal on Optimization"},{"key":"2557_CR22","unstructured":"Queensland Government. (2015). EPA, Grid-connected photovoltaic systems. http:\/\/www.soe-townsville.org\/data\/Gridconnected_photovoltaic_systems.pdf . Accessed August 28, 2015."},{"key":"2557_CR23","doi-asserted-by":"crossref","unstructured":"Rezgui, W., Mouss, N. K., Mouss, L. H., Mouss, M. D., Amirat, Y., & Benbouzid, M. (2014). Modeling the PV generator behavior submit to the open-circuit and the short-circuit faults. In Environmental friendly energies and applications (EFEA), 2014 3rd international symposium on (pp. 1\u20136). IEEE.","DOI":"10.1109\/EFEA.2014.7059978"},{"issue":"3","key":"2557_CR24","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1109\/TSTE.2011.2114901","volume":"2","author":"Y Riffonneau","year":"2011","unstructured":"Riffonneau, Y., Bacha, S., Barruel, F., & Ploix, S. (2011). Optimal power flow management for grid connected PV systems with batteries. IEEE Transactions on Sustainable Energy, 2(3), 309\u2013320.","journal-title":"IEEE Transactions on Sustainable Energy"},{"key":"2557_CR25","doi-asserted-by":"crossref","first-page":"21","DOI":"10.21314\/JOR.2000.038","volume":"2","author":"RT Rockafellar","year":"2000","unstructured":"Rockafellar, R. T., & Uryasev, S. (2000). Optimization of conditional value-at-risk. Journal of risk, 2, 21\u201342.","journal-title":"Journal of risk"},{"key":"2557_CR26","doi-asserted-by":"crossref","first-page":"1917","DOI":"10.1016\/j.renene.2006.09.003","volume":"32","author":"T Senjyu","year":"2007","unstructured":"Senjyu, T., Hayashi, D., Yona, A., Urasaki, N., & Funabashi, T. (2007). Optimal configuration of power generating systems in isolated island with renewable energy. Renewable Energy, 32, 1917\u20131933.","journal-title":"Renewable Energy"},{"key":"2557_CR27","unstructured":"Wallace, S. W., & Fleten, S. E. (2003). Stochastic programming models in energy, chap.10. In Ruszczynski and Shapiro A. Handbooks in OR & MS (pp. 637\u2013677)."},{"issue":"2","key":"2557_CR28","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1109\/TPWRS.2015.2423151","volume":"31","author":"Y Zhang","year":"2015","unstructured":"Zhang, Y., & Giannakis, G. B. (2015). Distributed stochastic market clearing with high-penetration wind power. IEEE Transactions on Power Systems, 31(2), 895\u2013906.","journal-title":"IEEE Transactions on Power Systems"}],"container-title":["Annals of Operations Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10479-017-2557-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10479-017-2557-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10479-017-2557-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T21:38:14Z","timestamp":1659130694000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10479-017-2557-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,20]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,3]]}},"alternative-id":["2557"],"URL":"https:\/\/doi.org\/10.1007\/s10479-017-2557-5","relation":{},"ISSN":["0254-5330","1572-9338"],"issn-type":[{"value":"0254-5330","type":"print"},{"value":"1572-9338","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,20]]}}}