{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T14:13:51Z","timestamp":1785420831151,"version":"3.56.0"},"reference-count":138,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"vor","delay-in-days":31,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100019737","name":"Information Technology Industry Development Agency","doi-asserted-by":"crossref","award":["ARP2019.R27.4"],"award-info":[{"award-number":["ARP2019.R27.4"]}],"id":[{"id":"10.13039\/501100019737","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Appl Intell"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:sec>\n                <jats:title>Abstract<\/jats:title>\n                <jats:p>Currently, learning physiological vital signs such as blood pressure (BP), hemoglobin levels, and oxygen saturation, from Photoplethysmography (PPG) signal, is receiving more attention. Despite successive progress that has been made so far, continuously revealing new aspects characterizes that field as a rich research topic. It includes a diverse number of critical points represented in signal denoising, data cleaning, employed features, feature format, feature selection, feature domain, model structure, problem formulation (regression or classification), and model combinations. It is worth noting that extensive research efforts are devoted to utilizing different variants of machine learning and deep learning models while transfer learning is not fully explored yet. So, in this paper, we are introducing a per-beat rPPG-to-BP mapping scheme based on transfer learning. An interesting representation of a 1-D PPG signal as a 2-D image is proposed for enabling powerful off-the-shelf image-based models through transfer learning. It resolves limitations about training data size due to strict data cleaning. Also, it enhances model generalization by exploiting underlying excellent feature extraction. Moreover, non-uniform data distribution (data skewness) is partially resolved by introducing logarithmic transformation. Furthermore, double cleaning is applied for training contact PPG data and testing rPPG beats as well. The quality of the segmented beats is tested by checking some of the related quality metrics. Hence, the prediction reliability is enhanced by excluding deformed beats. Varying rPPG quality is relaxed by selecting beats during intervals of the highest signal strength. Based on the experimental results, the proposed system outperforms the state-of-the-art systems in the sense of mean absolute error (MAE) and standard deviation (STD). STD for the test data is decreased to 5.4782 and 3.8539 for SBP and DBP, respectively. Also, MAE decreased to 2.3453 and 1.6854 for SBP and DBP, respectively. Moreover, the results for BP estimation from real video reveal that the STD reaches 8.027882 and 6.013052 for SBP and DBP, respectively. Also, MAE for the estimated BP from real videos reaches 7.052803 and 5.616028 for SBP and DBP, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Graphical abstract<\/jats:title>\n                <jats:p>Proposed camera-based blood pressure monitoring system<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s10489-024-05354-9","type":"journal-article","created":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T11:01:38Z","timestamp":1711969298000},"page":"4564-4584","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Video-based beat-by-beat blood pressure monitoring via transfer deep-learning"],"prefix":"10.1007","volume":"54","author":[{"given":"Osama A.","family":"Omer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6827-4655","authenticated-orcid":false,"given":"Mostafa","family":"Salah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Loay","family":"Hassan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Abdelreheem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ammar M.","family":"Hassan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,1]]},"reference":[{"key":"5354_CR1","unstructured":"Organization, WH (2022) Cardiovascular diseases, https:\/\/www.who.int\/health-topics\/cardiovascular-diseases#tab=tab_1, (Accessed on september, 22, 2022)"},{"key":"5354_CR2","doi-asserted-by":"crossref","unstructured":"Lam S, et al (2021) Intraoperative Invasive Blood Pressure Monitoring and the Potential Pitfalls of Invasively Measured Systolic Blood Pressure. Cureus 13(8)","DOI":"10.7759\/cureus.17610"},{"key":"5354_CR3","doi-asserted-by":"crossref","first-page":"231","DOI":"10.3389\/fmed.2017.00231","volume":"4","author":"AS Meidert","year":"2018","unstructured":"Meidert AS, Saugel B (2018) Techniques for non-invasive monitoring of arterial blood pressure. Front Med 4:231","journal-title":"Front Med"},{"key":"5354_CR4","unstructured":"Geddes LA (2013) Handbook of blood pressure measurement. Springer Science & Business Media"},{"key":"5354_CR5","unstructured":"American Society of Anesthesiologists. Standards of the American Society of Anesthesiologists: Standards for Basic Anesthetic Monitoring; Available from: https:\/\/www.asahq.org\/standards-and-guidelines\/standards-for-basic-anesthetic-monitoring-monitoring Accessed on February, 2022. (2020)"},{"key":"5354_CR6","doi-asserted-by":"crossref","unstructured":"Liao J, Liu D, Su G, Liu L (2021) Recognizing diseases with multivariate physiological signals by a DeepCNN-LSTM network. Appl Intell 1\u201313","DOI":"10.1007\/s10489-021-02309-2"},{"key":"5354_CR7","doi-asserted-by":"crossref","unstructured":"Xu W, Huang M-C (2015) Total health: Toward continuous personal monitoring, in Wearable Electronics Sensors. Springer. pp 37\u201356","DOI":"10.1007\/978-3-319-18191-2_2"},{"issue":"2","key":"5354_CR8","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.cjca.2021.10.011","volume":"38","author":"MH McGillion","year":"2022","unstructured":"McGillion MH, Allan K, Ross-Howe S et al (2022) Beyond wellness monitoring: continuous multiparameter remote automated monitoring of patients. Canadian J Cardiol 38(2):267\u2013278","journal-title":"Canadian J Cardiol"},{"key":"5354_CR9","doi-asserted-by":"crossref","first-page":"212478","DOI":"10.1109\/ACCESS.2020.3040257","volume":"8","author":"T Le","year":"2020","unstructured":"Le T et al (2020) Continuous non-invasive blood pressure monitoring: a methodological review on measurement techniques. IEEE Access 8:212478\u2013212498","journal-title":"IEEE Access"},{"key":"5354_CR10","doi-asserted-by":"crossref","unstructured":"Panula T et al (2022) Advances in non-invasive blood pressure measurement techniques. IEEE Rev Biomed Eng","DOI":"10.1109\/RBME.2022.3141877"},{"key":"5354_CR11","doi-asserted-by":"crossref","unstructured":"Mejia-Mejia E et al (2022) Photoplethysmography signal processing and synthesis. In: Photoplethysmography, Elsevier. pp 69\u2013146","DOI":"10.1016\/B978-0-12-823374-0.00015-3"},{"key":"5354_CR12","volume":"216","author":"HW Loh","year":"2022","unstructured":"Loh HW et al (2022) Application of photoplethysmography signals for healthcare systems: An in-depth review. Comput Methods Programs Biomed 216:106677","journal-title":"Comput Methods Programs Biomed"},{"key":"5354_CR13","doi-asserted-by":"crossref","unstructured":"Almarshad MA et al (2022) Diagnostic features and potential applications of PPG signal in healthcare: A systematic review. in Healthcare. MDPI","DOI":"10.3390\/healthcare10030547"},{"issue":"1","key":"5354_CR14","doi-asserted-by":"crossref","first-page":"89","DOI":"10.2478\/joeb-2021-0012","volume":"12","author":"B-J Singstad","year":"2021","unstructured":"Singstad B-J et al (2021) Estimation of heart rate variability from finger photoplethysmography during rest, mild exercise and mild mental stress. J Electrical Bioimpedance 12(1):89\u2013102","journal-title":"J Electrical Bioimpedance"},{"key":"5354_CR15","doi-asserted-by":"crossref","DOI":"10.1016\/j.bspc.2021.102483","volume":"66","author":"P Kuwalek","year":"2021","unstructured":"Kuwalek P et al (2021) Research on methods for detecting respiratory rate from photoplethysmographic signal. Biomed Signal Process Control 66:102483","journal-title":"Biomed Signal Process Control"},{"issue":"10","key":"5354_CR16","doi-asserted-by":"crossref","first-page":"316","DOI":"10.3390\/jcm7100316","volume":"7","author":"G Mart\u00ednez","year":"2018","unstructured":"Mart\u00ednez G et al (2018) Can photoplethysmography replace arterial blood pressure in the assessment of blood pressure? J Clinical Med 7(10):316","journal-title":"J Clinical Med"},{"issue":"1","key":"5354_CR17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41746-019-0136-7","volume":"2","author":"M Elgendi","year":"2019","unstructured":"Elgendi M et al (2019) The use of photoplethysmography for assessing hypertension. NPJ Digital Med 2(1):1\u201311","journal-title":"NPJ Digital Med"},{"key":"5354_CR18","doi-asserted-by":"crossref","unstructured":"Omer OA et al (2022) Beat-by-Beat ECG Monitoring from Photoplythmography Based on Scattering Wavelet Transform. Traitement du Signal 39(5)","DOI":"10.18280\/ts.390504"},{"issue":"23","key":"5354_CR19","doi-asserted-by":"crossref","first-page":"16734","DOI":"10.1109\/JIOT.2021.3097946","volume":"8","author":"Q Zhu","year":"2021","unstructured":"Zhu Q et al (2021) Learning your heart actions from pulse: ECG waveform reconstruction from PPG. IEEE Int Things J 8(23):16734\u201316748","journal-title":"IEEE Int Things J"},{"issue":"7","key":"5354_CR20","doi-asserted-by":"crossref","first-page":"377","DOI":"10.3390\/info14070377","volume":"14","author":"KM Abdelgaber","year":"2023","unstructured":"Abdelgaber KM et al (2023) Subject-Independent per Beat PPG to Single-Lead ECG Mapping. Information 14(7):377","journal-title":"Information"},{"key":"5354_CR21","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1016\/j.asoc.2015.04.008","volume":"37","author":"AR Kavsao\u011flu","year":"2015","unstructured":"Kavsao\u011flu AR, Polat K, Hariharan M (2015) Non-invasive prediction of hemoglobin level using machine learning techniques with the PPG signal\u2019s characteristics features. Appl Soft Comput 37:983\u2013991","journal-title":"Appl Soft Comput"},{"key":"5354_CR22","doi-asserted-by":"crossref","unstructured":"Haque CA et al (2021) Comparison of Different Methods to Estimate Blood Oxygen Saturation using PPG. In: 2021 International conference on information and communication technology convergence (ICTC). IEEE","DOI":"10.1109\/ICTC52510.2021.9621142"},{"key":"5354_CR23","doi-asserted-by":"crossref","unstructured":"Liu Z-D et al (2023) Cuffless Blood Pressure Measurement using Smartwatches: A Large-scale Validation Study. IEEE J Biomed Health Inform","DOI":"10.1109\/JBHI.2023.3278168"},{"issue":"1","key":"5354_CR24","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1038\/s41746-023-00835-6","volume":"6","author":"L Zhao","year":"2023","unstructured":"Zhao L et al (2023) Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. NPJ Digital Med 6(1):93","journal-title":"NPJ Digital Med"},{"key":"5354_CR25","doi-asserted-by":"crossref","unstructured":"Ray I et al (2021) Skin tone, confidence, and data quality of heart rate sensing in WearOS smartwatches. In: 2021 IEEE International conference on pervasive computing and communications workshops and other affiliated events (PerCom Workshops). IEEE","DOI":"10.1109\/PerComWorkshops51409.2021.9431120"},{"issue":"11","key":"5354_CR26","doi-asserted-by":"crossref","first-page":"3812","DOI":"10.3390\/s18113812","volume":"18","author":"F Qureshi","year":"2018","unstructured":"Qureshi F, Krishnan S (2018) Wearable hardware design for the internet of medical things (IoMT). Sensors 18(11):3812","journal-title":"Sensors"},{"issue":"5","key":"5354_CR27","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1515\/bmt-2017-0119","volume":"63","author":"S Zaunseder","year":"2018","unstructured":"Zaunseder S et al (2018) Cardiovascular assessment by imaging photoplethysmography-a review. Biomed Eng\/Biomedizinische Technik 63(5):617\u2013634","journal-title":"Biomed Eng\/Biomedizinische Technik"},{"issue":"5","key":"5354_CR28","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1364\/BOE.6.001565","volume":"6","author":"M Kumar","year":"2015","unstructured":"Kumar M, Veeraraghavan A, Sabharwal A (2015) DistancePPG: Robust non-contact vital signs monitoring using a camera. Biomed Optics Express 6(5):1565\u20131588","journal-title":"Biomed Optics Express"},{"key":"5354_CR29","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.bspc.2017.07.004","volume":"38","author":"MA Hassan","year":"2017","unstructured":"Hassan MA et al (2017) Heart rate estimation using facial video: A review. Biomed Signal Process Control 38:346\u2013360","journal-title":"Biomed Signal Process Control"},{"issue":"1","key":"5354_CR30","first-page":"1","volume":"8","author":"AV Mo\u00e7o","year":"2018","unstructured":"Mo\u00e7o AV, Stuijk S, de Haan G (2018) New insights into the origin of remote PPG signals in visible light and infrared. Scientific Report 8(1):1\u201315","journal-title":"Scientific Report"},{"issue":"1","key":"5354_CR31","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/srep10494","volume":"5","author":"AA Kamshilin","year":"2015","unstructured":"Kamshilin AA et al (2015) A new look at the essence of the imaging photoplethysmography. Scientific Reports 5(1):1\u20139","journal-title":"Scientific Reports"},{"issue":"22","key":"5354_CR32","doi-asserted-by":"crossref","first-page":"10624","DOI":"10.1109\/JSEN.2019.2931775","volume":"19","author":"Y Zhou","year":"2019","unstructured":"Zhou Y et al (2019) The noninvasive blood pressure measurement based on facial images processing. IEEE Sensors J 19(22):10624\u201310634","journal-title":"IEEE Sensors J"},{"issue":"9","key":"5354_CR33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3558518","volume":"55","author":"D McDuff","year":"2023","unstructured":"McDuff D (2023) Camera measurement of physiological vital signs. ACM Comput Surv 55(9):1\u201340","journal-title":"ACM Comput Surv"},{"issue":"1","key":"5354_CR34","first-page":"1","volume":"8","author":"K Matsumura","year":"2018","unstructured":"Matsumura K et al (2018) Cuffless blood pressure estimation using only a smartphone. Sci Reports 8(1):1\u20139","journal-title":"Sci Reports"},{"key":"5354_CR35","doi-asserted-by":"crossref","unstructured":"Luo H et al (2019) Smartphone-based blood pressure measurement using transdermal optical imaging technology. Circulation: Cardiovascular Imaging 12(8):e008857","DOI":"10.1161\/CIRCIMAGING.119.008857"},{"key":"5354_CR36","unstructured":"Qayyum A et al (2022) Assessment of physiological states from contactless face video: a sparse representation approach. Computing 1\u201321"},{"issue":"23","key":"5354_CR37","doi-asserted-by":"crossref","first-page":"8630","DOI":"10.3390\/app10238630","volume":"10","author":"A Gudi","year":"2020","unstructured":"Gudi A, Bittner M, van Gemert Jv, (2020) Real-Time Webcam Heart-Rate and Variability Estimation with Clean Ground Truth for Evaluation. Appl Sci 10(23):8630","journal-title":"Appl Sci"},{"key":"5354_CR38","doi-asserted-by":"crossref","unstructured":"Salah M et al (2022) Robust Facial-Based Inter-Beat Interval Estimation Through Spectral Signature Tracking and Periodic Filtering. In: Intelligent Sustainable Systems. Singapore: Springer Singapore","DOI":"10.1007\/978-981-16-6309-3_17"},{"key":"5354_CR39","doi-asserted-by":"crossref","unstructured":"Steinman J et al (2021) Smartphones and Video Cameras: Future Methods for Blood Pressure Measurement. Front Digital Health 3","DOI":"10.3389\/fdgth.2021.770096"},{"key":"5354_CR40","doi-asserted-by":"crossref","unstructured":"Hosni A, Atef M (2023) Remote real-time heart rate monitoring with recursive motion artifact removal using PPG signals from a smartphone camera. Multimed Tools Appl 1\u201318","DOI":"10.1007\/s11042-023-14399-w"},{"issue":"7","key":"5354_CR41","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1109\/TBME.2016.2609282","volume":"64","author":"W Wang","year":"2016","unstructured":"Wang W et al (2016) Algorithmic principles of remote PPG. IEEE Trans Biomed Eng 64(7):1479\u20131491","journal-title":"IEEE Trans Biomed Eng"},{"key":"5354_CR42","unstructured":"Saeed M et al (2002) MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring. in Computers in cardiology. IEEE"},{"issue":"1","key":"5354_CR43","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/sdata.2016.35","volume":"3","author":"AE Johnson","year":"2016","unstructured":"Johnson AE et al (2016) MIMIC-III, a freely accessible critical care database. Scientific Data 3(1):1\u20139","journal-title":"Scientific Data"},{"issue":"1","key":"5354_CR44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41597-018-0002-5","volume":"5","author":"Y Liang","year":"2018","unstructured":"Liang Y et al (2018) A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China. Sci Data 5(1):1\u20137","journal-title":"Sci Data"},{"issue":"23","key":"5354_CR45","doi-asserted-by":"crossref","first-page":"e215","DOI":"10.1161\/01.CIR.101.23.e215","volume":"101","author":"AL Goldberger","year":"2000","unstructured":"Goldberger AL et al (2000) PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation 101(23):e215\u2013e220","journal-title":"Circulation"},{"key":"5354_CR46","doi-asserted-by":"crossref","unstructured":"Qin K et al (2022) Machine learning and deep learning for blood pressure prediction: a methodological review from multiple perspectives. Artif Intell Rev 1\u2013102","DOI":"10.1007\/s10462-022-10353-8"},{"key":"5354_CR47","unstructured":"Yin R-N et al (2021) Heart rate estimation based on face video under unstable illumination. Appl Intell 1\u201317"},{"issue":"1","key":"5354_CR48","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1109\/TBME.2019.2908349","volume":"67","author":"H Rahman","year":"2019","unstructured":"Rahman H, Ahmed MU, Begum S (2019) Non-contact physiological parameters extraction using facial video considering illumination, motion, movement and vibration. IEEE Trans Biomed Eng 67(1):88\u201398","journal-title":"IEEE Trans Biomed Eng"},{"key":"5354_CR49","doi-asserted-by":"crossref","unstructured":"Mironenko Y et al (2020) Remote photoplethysmography: Rarely considered factors. In: Proceedings of the IEEE\/CVF conference on computer vision and pattern recognition workshops","DOI":"10.1109\/CVPRW50498.2020.00156"},{"issue":"26","key":"5354_CR50","doi-asserted-by":"crossref","first-page":"21434","DOI":"10.1364\/OE.16.021434","volume":"16","author":"W Verkruysse","year":"2008","unstructured":"Verkruysse W, Svaasand LO, Nelson JS (2008) Remote plethysmographic imaging using ambient light. Optics Express 16(26):21434\u201321445","journal-title":"Optics Express"},{"key":"5354_CR51","doi-asserted-by":"crossref","unstructured":"Man P-K et al (2022) Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring. in Healthcare MDPI","DOI":"10.3390\/healthcare10102113"},{"issue":"1","key":"5354_CR52","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1038\/s41597-023-02020-6","volume":"10","author":"S Gonz\u00e1lez","year":"2023","unstructured":"Gonz\u00e1lez S, Hsieh W-T, Chen TP-C (2023) A benchmark for machine-learning based non-invasive blood pressure estimation using photoplethysmogram. Scientific Data 10(1):149","journal-title":"Scientific Data"},{"issue":"18","key":"5354_CR53","doi-asserted-by":"crossref","first-page":"6022","DOI":"10.3390\/s21186022","volume":"21","author":"F Schrumpf","year":"2021","unstructured":"Schrumpf F et al (2021) Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning. Sensors 21(18):6022","journal-title":"Sensors"},{"key":"5354_CR54","doi-asserted-by":"crossref","first-page":"216083","DOI":"10.1109\/ACCESS.2020.3040936","volume":"8","author":"G Boccignone","year":"2020","unstructured":"Boccignone G et al (2020) An Open Framework for Remote-PPG Methods and their Assessment. IEEE Access 8:216083\u2013216103","journal-title":"IEEE Access"},{"issue":"7","key":"5354_CR55","doi-asserted-by":"crossref","first-page":"1278","DOI":"10.3390\/diagnostics13071278","volume":"13","author":"M Nour","year":"2023","unstructured":"Nour M et al (2023) A Novel Cuffless Blood Pressure Prediction: Uncovering New Features and New Hybrid ML Models. Diagnostics 13(7):1278","journal-title":"Diagnostics"},{"key":"5354_CR56","doi-asserted-by":"crossref","unstructured":"Bulh\u00f5es da Silva Costa T et al (2023) Blood pressure estimation from photoplethysmography by considering intra-and inter-subject variabilities: guidelines for a fair assessment","DOI":"10.36227\/techrxiv.21637316.v2"},{"key":"5354_CR57","volume":"86","author":"J Liu","year":"2023","unstructured":"Liu J et al (2023) A novel interpretable feature set optimization method in blood pressure estimation using photoplethysmography signals. Biomed Signal Process Control 86:105184","journal-title":"Biomed Signal Process Control"},{"issue":"1","key":"5354_CR58","first-page":"1085","volume":"31","author":"AA Mukhlif","year":"2022","unstructured":"Mukhlif AA, Al-Khateeb B, Mohammed MA (2022) An extensive review of state-of-the-art transfer learning techniques used in medical imaging: Open issues and challenges. J Intell Syst 31(1):1085\u20131111","journal-title":"J Intell Syst"},{"key":"5354_CR59","doi-asserted-by":"crossref","unstructured":"Magdalena Nowara E et al (2018) SparsePPG: Towards driver monitoring using camera-based vital signs estimation in near-infrared. In: Proceedings of the IEEE conference on computer vision and pattern recognition workshops","DOI":"10.1109\/CVPRW.2018.00174"},{"key":"5354_CR60","doi-asserted-by":"crossref","unstructured":"Xi L et al (2022) Weighted Combination and Singular Spectrum Analysis Based Remote Photoplethysmography Pulse Extraction in Low-light Environments. Med Eng Phys 103822","DOI":"10.1016\/j.medengphy.2022.103822"},{"key":"5354_CR61","doi-asserted-by":"crossref","unstructured":"Zhao C et al (2018) A novel framework for remote photoplethysmography pulse extraction on compressed videos. In: Proceedings of the IEEE conference on computer vision and pattern recognition workshops","DOI":"10.1109\/CVPRW.2018.00177"},{"issue":"6","key":"5354_CR62","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1088\/1361-6579\/aa6d02","volume":"38","author":"W Wang","year":"2017","unstructured":"Wang W et al (2017) Robust heart rate from fitness videos. Physiological Measure 38(6):1023","journal-title":"Physiological Measure"},{"key":"5354_CR63","doi-asserted-by":"crossref","unstructured":"Lovisotto G et al (2020) Seeing red: PPG biometrics using smartphone cameras. In: Proceedings of the IEEE\/CVF conference on computer vision and pattern recognition workshops","DOI":"10.1109\/CVPRW50498.2020.00417"},{"key":"5354_CR64","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2021.104860","volume":"138","author":"F Bousefsaf","year":"2021","unstructured":"Bousefsaf F et al (2021) iPPG 2 cPPG: Reconstructing contact from imaging photoplethysmographic signals using U-Net architectures. Comput Biol Med 138:104860","journal-title":"Comput Biol Med"},{"issue":"4","key":"5354_CR65","doi-asserted-by":"crossref","first-page":"1876","DOI":"10.1364\/BOE.380646","volume":"11","author":"D Wang","year":"2020","unstructured":"Wang D et al (2020) Detail-preserving pulse wave extraction from facial videos using consume-level camera. Biomed Optics Express 11(4):1876\u20131891","journal-title":"Biomed Optics Express"},{"key":"5354_CR66","doi-asserted-by":"crossref","unstructured":"Pham C et al (2021) Effectiveness of consumer-grade contactless vital signs monitors: a systematic review and meta-analysis. J Clinical Monitoring Comput 1\u201314","DOI":"10.1007\/s10877-021-00734-9"},{"key":"5354_CR67","doi-asserted-by":"crossref","first-page":"76513","DOI":"10.1109\/ACCESS.2019.2922304","volume":"7","author":"R Fouad","year":"2019","unstructured":"Fouad R, Omer OA, Aly MH (2019) Optimizing remote photoplethysmography using adaptive skin segmentation for real-time heart rate monitoring. IEEE Access 7:76513\u201376528","journal-title":"IEEE Access"},{"key":"5354_CR68","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.patrec.2017.10.017","volume":"124","author":"S Bobbia","year":"2019","unstructured":"Bobbia S et al (2019) Unsupervised skin tissue segmentation for remote photoplethysmography. Pattern Recognition Lett 124:82\u201390","journal-title":"Pattern Recognition Lett"},{"issue":"8","key":"5354_CR69","doi-asserted-by":"crossref","first-page":"3467","DOI":"10.3390\/app11083467","volume":"11","author":"\u017d Pirnar","year":"2021","unstructured":"Pirnar \u017d, Fin\u017egar M, Podr\u017eaj P (2021) Performance Evaluation of rPPG Approaches with and without the Region-of-Interest Localization Step. Appl Sci 11(8):3467","journal-title":"Appl Sci"},{"key":"5354_CR70","doi-asserted-by":"crossref","DOI":"10.1016\/j.bspc.2022.103538","volume":"74","author":"S Zaunseder","year":"2022","unstructured":"Zaunseder S et al (2022) Signal-to-noise ratio is more important than sampling rate in beat-to-beat interval estimation from optical sensors. Biomed Signal Process Control 74:103538","journal-title":"Biomed Signal Process Control"},{"issue":"12","key":"5354_CR71","doi-asserted-by":"crossref","first-page":"2543","DOI":"10.1088\/0967-3334\/35\/12\/2543","volume":"35","author":"J Wander","year":"2014","unstructured":"Wander J, Morris D (2014) A combined segmenting and non-segmenting approach to signal quality estimation for ambulatory photoplethysmography. Physiological Measurement 35(12):2543","journal-title":"Physiological Measurement"},{"issue":"2","key":"5354_CR72","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1007\/s11818-017-0115-7","volume":"21","author":"C Fischer","year":"2017","unstructured":"Fischer C et al (2017) Extended algorithm for real-time pulse waveform segmentation and artifact detection in photoplethysmograms. Somnologie 21(2):110\u2013120","journal-title":"Somnologie"},{"issue":"10","key":"5354_CR73","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0076585","volume":"8","author":"M Elgendi","year":"2013","unstructured":"Elgendi M et al (2013) Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions. PLoS One 8(10):e76585","journal-title":"PLoS One"},{"issue":"10","key":"5354_CR74","doi-asserted-by":"crossref","first-page":"2752","DOI":"10.3390\/s20102752","volume":"20","author":"P Li","year":"2020","unstructured":"Li P et al (2020) Video-Based Pulse Rate Variability Measurement Using Periodic Variance Maximization and Adaptive Two-Window Peak Detection. Sensors 20(10):2752","journal-title":"Sensors"},{"issue":"4","key":"5354_CR75","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1109\/TBME.2016.2580904","volume":"64","author":"M Kachuee","year":"2016","unstructured":"Kachuee M et al (2016) Cuffless blood pressure estimation algorithms for continuous health-care monitoring. IEEE Trans Biomed Eng 64(4):859\u2013869","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"5354_CR76","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s13534-019-00096-x","volume":"9","author":"X Ding","year":"2019","unstructured":"Ding X, Zhang Y-T (2019) Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm. Biomed Eng Lett 9(1):37\u201352","journal-title":"Biomed Eng Lett"},{"key":"5354_CR77","volume-title":"How effective is pulse arrival time for evaluating blood pressure?","author":"Y Liang","year":"2019","unstructured":"Liang Y, Abbott D, Howard N, Lim K, Ward R, Elgendi M (2019) How effective is pulse arrival time for evaluating blood pressure? Challenges and recommendations from a study using the MIMIC database, J Clinical Med"},{"key":"5354_CR78","unstructured":"Clifford GD, Scott DJ, Villarroel M (2010) User guide and documentation for the MIMIC II database (version 2, release 1)"},{"issue":"1","key":"5354_CR79","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1038\/s41598-022-27170-2","volume":"13","author":"E Finnegan","year":"2023","unstructured":"Finnegan E et al (2023) Features from the photoplethysmogram and the electrocardiogram for estimating changes in blood pressure. Scientific Reports 13(1):986","journal-title":"Scientific Reports"},{"key":"5354_CR80","doi-asserted-by":"crossref","unstructured":"Khalid SG et al (2018) Blood pressure estimation using photoplethysmography only: comparison between different machine learning approaches. J Healthcare Eng 2018","DOI":"10.1155\/2018\/1548647"},{"key":"5354_CR81","unstructured":"Slapni\u010dar G, Lu\u0161trek M, Marinko M (2018) Continuous blood pressure estimation from PPG signal. Informatica 42(1)"},{"key":"5354_CR82","doi-asserted-by":"crossref","first-page":"141970","DOI":"10.1109\/ACCESS.2019.2942936","volume":"7","author":"W-R Yan","year":"2019","unstructured":"Yan W-R et al (2019) Cuffless continuous blood pressure estimation from pulse morphology of photoplethysmograms. IEEE Access 7:141970\u2013141977","journal-title":"IEEE Access"},{"issue":"15","key":"5354_CR83","doi-asserted-by":"crossref","first-page":"3420","DOI":"10.3390\/s19153420","volume":"19","author":"G Slapni\u010dar","year":"2019","unstructured":"Slapni\u010dar G, Mlakar N, Lu\u0161trek M (2019) Blood pressure estimation from photoplethysmogram using a spectro-temporal deep neural network. Sensors 19(15):3420","journal-title":"Sensors"},{"issue":"8","key":"5354_CR84","doi-asserted-by":"crossref","first-page":"3007","DOI":"10.1364\/BOE.7.003007","volume":"7","author":"X Xing","year":"2016","unstructured":"Xing X, Sun M (2016) Optical blood pressure estimation with photoplethysmography and FFT-based neural networks. Biomed Optics Express 7(8):3007\u20133020","journal-title":"Biomed Optics Express"},{"issue":"4","key":"5354_CR85","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3390\/bios8040101","volume":"8","author":"Y Liang","year":"2018","unstructured":"Liang Y et al (2018) Photoplethysmography and deep learning: enhancing hypertension risk stratification. Biosensors 8(4):101","journal-title":"Biosensors"},{"key":"5354_CR86","doi-asserted-by":"crossref","first-page":"1090854","DOI":"10.3389\/fdgth.2022.1090854","volume":"4","author":"W Wang","year":"2023","unstructured":"Wang W et al (2023) PulseDB: A large, cleaned dataset based on MIMIC-III and VitalDB for benchmarking cuff-less blood pressure estimation methods. Front Digital Health 4:1090854","journal-title":"Front Digital Health"},{"key":"5354_CR87","doi-asserted-by":"crossref","first-page":"55616","DOI":"10.1109\/ACCESS.2022.3175436","volume":"10","author":"M Salah","year":"2022","unstructured":"Salah M et al (2022) Beat-Based PPG-ABP Cleaning Technique for Blood Pressure Estimation. IEEE Access 10:55616\u201355626","journal-title":"IEEE Access"},{"key":"5354_CR88","doi-asserted-by":"crossref","unstructured":"Schrumpf F, Serdack PR, Fuchs M (2022) Regression or Classification? Reflection on BP prediction from PPG data using Deep Neural Networks in the scope of practical applications. In: Proceedings of the IEEE\/CVF conference on computer vision and pattern recognition","DOI":"10.1109\/CVPRW56347.2022.00236"},{"key":"5354_CR89","volume":"84","author":"NF Ali","year":"2023","unstructured":"Ali NF, Atef M (2023) An efficient hybrid LSTM-ANN joint classification-regression model for PPG based blood pressure monitoring. Biomed Signal Process Control 84:104782","journal-title":"Biomed Signal Process Control"},{"key":"5354_CR90","doi-asserted-by":"crossref","unstructured":"Schrumpf F et al (2021) Assessment of deep learning based blood pressure prediction from PPG and rPPG signals. In: Proceedings of the IEEE\/CVF conference on computer vision and pattern recognition","DOI":"10.1109\/CVPRW53098.2021.00423"},{"issue":"19","key":"5354_CR91","doi-asserted-by":"crossref","first-page":"5668","DOI":"10.3390\/s20195668","volume":"20","author":"Y-C Hsu","year":"2020","unstructured":"Hsu Y-C et al (2020) Generalized deep neural network model for cuffless blood pressure estimation with photoplethysmogram signal only. Sensors 20(19):5668","journal-title":"Sensors"},{"issue":"4","key":"5354_CR92","doi-asserted-by":"crossref","first-page":"400","DOI":"10.3390\/bioengineering10040400","volume":"10","author":"C Qin","year":"2023","unstructured":"Qin C et al (2023) Cuff-Less Blood Pressure Prediction Based on Photoplethysmography and Modified ResNet. Bioengineering 10(4):400","journal-title":"Bioengineering"},{"key":"5354_CR93","doi-asserted-by":"crossref","DOI":"10.1016\/j.bspc.2023.105029","volume":"85","author":"S Kanoga","year":"2023","unstructured":"Kanoga S et al (2023) Comparison of seven shallow and deep regressors in continuous blood pressure and heart rate estimation using single-channel photoplethysmograms under three evaluation cases. Biomed Signal Process Control 85:105029","journal-title":"Biomed Signal Process Control"},{"issue":"11","key":"5354_CR94","doi-asserted-by":"crossref","first-page":"692","DOI":"10.3390\/bioengineering9110692","volume":"9","author":"N Ibtehaz","year":"2022","unstructured":"Ibtehaz N et al (2022) PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms. Bioengineering 9(11):692","journal-title":"Bioengineering"},{"issue":"9","key":"5354_CR95","doi-asserted-by":"crossref","first-page":"2952","DOI":"10.3390\/s21092952","volume":"21","author":"LN Harfiya","year":"2021","unstructured":"Harfiya LN, Chang C-C, Li Y-H (2021) Continuous blood pressure estimation using exclusively photopletysmography by LSTM-based signal-to-signal translation. Sensors 21(9):2952","journal-title":"Sensors"},{"issue":"18","key":"5354_CR96","doi-asserted-by":"crossref","first-page":"6311","DOI":"10.3390\/s21186311","volume":"21","author":"E Brophy","year":"2021","unstructured":"Brophy E et al (2021) Estimation of continuous blood pressure from ppg via a federated learning approach. Sensors 21(18):6311","journal-title":"Sensors"},{"key":"5354_CR97","unstructured":"Yosinski J et al (2014) How transferable are features in deep neural networks? Adv Neural Inform Process Syst 27"},{"key":"5354_CR98","doi-asserted-by":"crossref","unstructured":"Morassi Sasso A et al (2020) HYPE: Predicting blood pressure from photoplethysmograms in a hypertensive population. In: International conference on artificial intelligence in medicine, Springer","DOI":"10.1007\/978-3-030-59137-3_29"},{"issue":"5","key":"5354_CR99","doi-asserted-by":"crossref","first-page":"2075","DOI":"10.1109\/JBHI.2021.3128383","volume":"26","author":"W Wang","year":"2021","unstructured":"Wang W et al (2021) Cuff-less blood pressure estimation from photoplethysmography via visibility graph and transfer learning. IEEE J Biomed Health Inform 26(5):2075\u20132085","journal-title":"IEEE J Biomed Health Inform"},{"key":"5354_CR100","volume":"64","author":"H Mou","year":"2022","unstructured":"Mou H, Yu J (2022) Transfer learning with DWT based clustering for blood pressure estimation of multiple patients. J Comput Sci 64:101865","journal-title":"J Comput Sci"},{"issue":"1","key":"5354_CR101","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1109\/JBHI.2021.3085526","volume":"26","author":"J Leitner","year":"2021","unstructured":"Leitner J, Chiang P-H, Dey S (2021) Personalized blood pressure estimation using photoplethysmography: A transfer learning approach. IEEE J Biomed Health Inform 26(1):218\u2013228","journal-title":"IEEE J Biomed Health Inform"},{"issue":"12","key":"5354_CR102","doi-asserted-by":"crossref","first-page":"5907","DOI":"10.1109\/JBHI.2022.3206477","volume":"26","author":"Y Zhang","year":"2022","unstructured":"Zhang Y et al (2022) A Refined Blood Pressure Estimation Model Based on Single Channel Photoplethysmography. IEEE J Biomed Health Inform 26(12):5907\u20135917","journal-title":"IEEE J Biomed Health Inform"},{"issue":"22","key":"5354_CR103","doi-asserted-by":"crossref","first-page":"3749","DOI":"10.3390\/electronics11223749","volume":"11","author":"NF Ali","year":"2022","unstructured":"Ali NF, Atef M (2022) LSTM Multi-Stage Transfer Learning for Blood Pressure Estimation Using Photoplethysmography. Electronics 11(22):3749","journal-title":"Electronics"},{"key":"5354_CR104","doi-asserted-by":"crossref","unstructured":"Huthart S et al (2020) Advancing PPG signal quality and know-how through knowledge translation-from experts to student and researcher. Front Digital Health","DOI":"10.3389\/fdgth.2020.619692"},{"key":"5354_CR105","doi-asserted-by":"crossref","unstructured":"Athaya T, Choi S (2020) Evaluation of Different Machine Learning Models for Photoplethysmogram Signal Artifact Detection. In: 2020 International conference on information and communication technology convergence (ICTC), IEEE","DOI":"10.1109\/ICTC49870.2020.9289366"},{"key":"5354_CR106","doi-asserted-by":"crossref","first-page":"29736","DOI":"10.1109\/ACCESS.2021.3054613","volume":"9","author":"O Zhang","year":"2021","unstructured":"Zhang O et al (2021) Explainability Metrics of Deep Convolutional Networks for Photoplethysmography Quality Assessment. IEEE Access 9:29736\u201329745","journal-title":"IEEE Access"},{"key":"5354_CR107","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1016\/j.procs.2019.04.074","volume":"151","author":"EK Naeini","year":"2019","unstructured":"Naeini EK et al (2019) A real-time PPG quality assessment approach for healthcare Internet-of-Things. Procedia Comput Sci 151:551\u2013558","journal-title":"Procedia Comput Sci"},{"issue":"6","key":"5354_CR108","doi-asserted-by":"crossref","first-page":"2188","DOI":"10.3390\/s21062188","volume":"21","author":"D Roh","year":"2021","unstructured":"Roh D, Shin H (2021) Recurrence Plot and Machine Learning for Signal Quality Assessment of Photoplethysmogram in Mobile Environment. Sensors 21(6):2188","journal-title":"Sensors"},{"issue":"7","key":"5354_CR109","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1007\/s11517-016-1453-5","volume":"54","author":"N Gambarotta","year":"2016","unstructured":"Gambarotta N et al (2016) A review of methods for the signal quality assessment to improve reliability of heart rate and blood pressures derived parameters. Med Biological Eng Comput 54(7):1025\u20131035","journal-title":"Med Biological Eng Comput"},{"issue":"19","key":"5354_CR110","doi-asserted-by":"crossref","first-page":"9582","DOI":"10.3390\/app12199582","volume":"12","author":"T Desquins","year":"2022","unstructured":"Desquins T et al (2022) A Survey of Photoplethysmography and Imaging Photoplethysmography Quality Assessment Methods. Appl Sci 12(19):9582","journal-title":"Appl Sci"},{"key":"5354_CR111","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2021.105146","volume":"141","author":"B Lokendra","year":"2022","unstructured":"Lokendra B, Puneet G (2022) AND-rPPG: A novel denoising-rPPG network for improving remote heart rate estimation. Comput Biol Med 141:105146","journal-title":"Comput Biol Med"},{"key":"5354_CR112","doi-asserted-by":"publisher","unstructured":"Lu H, Han H, Zhou SK (2021) Dual-GAN: Joint BVP and Noise Modeling for Remote Physiological Measurement. In: 2021 IEEE\/CVF Conference on computer vision and pattern recognition (CVPR), Nashville, TN, USA, 2021, pp 12399\u201312408. https:\/\/doi.org\/10.1109\/CVPR46437.2021.01222","DOI":"10.1109\/CVPR46437.2021.01222"},{"issue":"12","key":"5354_CR113","doi-asserted-by":"crossref","first-page":"4874","DOI":"10.1364\/BOE.7.004874","volume":"7","author":"R Amelard","year":"2016","unstructured":"Amelard R, Clausi DA, Wong A (2016) Spectral-spatial fusion model for robust blood pulse waveform extraction in photoplethysmographic imaging. Biomed Optics Express 7(12):4874\u20134885","journal-title":"Biomed Optics Express"},{"key":"5354_CR114","doi-asserted-by":"crossref","unstructured":"Revanur A et al (2021) The first vision for vitals (v4v) challenge for non-contact video-based physiological estimation. In: Proceedings of the IEEE\/CVF international conference on computer vision","DOI":"10.1109\/ICCVW54120.2021.00310"},{"key":"5354_CR115","doi-asserted-by":"publisher","unstructured":"Zahid Hasan SRR, Roy N (2021) MPSC-rPPG Dataset. https:\/\/doi.org\/10.21227\/ddgz-tx88 IEEE Dataport","DOI":"10.21227\/ddgz-tx88"},{"key":"5354_CR116","doi-asserted-by":"publisher","unstructured":"Kopeliovich M, Petrushan M (2022) rPPG Dataset. https:\/\/doi.org\/10.17605\/OSF.IO\/FDRBH","DOI":"10.17605\/OSF.IO\/FDRBH"},{"key":"5354_CR117","doi-asserted-by":"publisher","unstructured":"Kachuee M, Kiani MM, Mohammadzade H, Shabany M (2015) Cuff-less high-accuracy calibration-free blood pressure estimation using pulse transit time. In: 2015 IEEE International symposium on circuits and systems (ISCAS), Lisbon, Portugal, pp 1006\u20131009. https:\/\/doi.org\/10.1109\/ISCAS.2015.7168806","DOI":"10.1109\/ISCAS.2015.7168806"},{"key":"5354_CR118","doi-asserted-by":"publisher","unstructured":"Johnson A, Bulgarelli L, Pollard T, Horng S, Celi LA, Mark R (2022) MIMIC-IV (version 2.1). PhysioNet. https:\/\/doi.org\/10.13026\/rrgf-xw32.2022","DOI":"10.13026\/rrgf-xw32.2022"},{"issue":"1","key":"5354_CR119","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1038\/s41597-022-01411-5","volume":"9","author":"H-C Lee","year":"2022","unstructured":"Lee H-C et al (2022) VitalDB, a high-fidelity multi-parameter vital signs database in surgical patients. Scientific Data 9(1):279","journal-title":"Scientific Data"},{"key":"5354_CR120","doi-asserted-by":"crossref","DOI":"10.3389\/frai.2021.691626","volume":"4","author":"P Rogers","year":"2021","unstructured":"Rogers P, Wang D, Lu Z (2021) Medical information mart for intensive care: a foundation for the fusion of artificial intelligence and real-world data. Front Artif Intell 4:691626","journal-title":"Front Artif Intell"},{"key":"5354_CR121","doi-asserted-by":"crossref","unstructured":"Data MC, Mark R (2016) The story of MIMIC. Secondary Anal Electronic Health Records 43\u201349","DOI":"10.1007\/978-3-319-43742-2_5"},{"issue":"10","key":"5354_CR122","doi-asserted-by":"crossref","first-page":"1499","DOI":"10.1109\/LSP.2016.2603342","volume":"23","author":"K Zhang","year":"2016","unstructured":"Zhang K et al (2016) Joint face detection and alignment using multitask cascaded convolutional networks. IEEE Signal Process Lett 23(10):1499\u20131503","journal-title":"IEEE Signal Process Lett"},{"key":"5354_CR123","doi-asserted-by":"publisher","unstructured":"Jiang H, Learned-Miller E (2017) \u201cFace Detection with the Faster R-CNN,\u201d 2017 12th IEEE International Conference on Automatic Face & Gesture Recognition (FG 2017), Washington, DC, USA, pp 650\u2013657. https:\/\/doi.org\/10.1109\/FG.2017.82","DOI":"10.1109\/FG.2017.82"},{"key":"5354_CR124","doi-asserted-by":"publisher","unstructured":"Ye B, Shi Y, Li H, Li L, Tong S (2021) \u201cFace SSD: A Real-time Face Detector based on SSD,\u201d 2021 40th Chinese Control Conference (CCC), Shanghai, China, pp 8445\u20138450. https:\/\/doi.org\/10.23919\/CCC52363.2021.9550294","DOI":"10.23919\/CCC52363.2021.9550294"},{"key":"5354_CR125","doi-asserted-by":"crossref","unstructured":"Garg D et al (2018) A deep learning approach for face detection using YOLO. In: 2018 IEEE Punecon, IEEE","DOI":"10.1109\/PUNECON.2018.8745376"},{"issue":"3","key":"5354_CR126","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1109\/TPAMI.2014.2345390","volume":"37","author":"JF Henriques","year":"2014","unstructured":"Henriques JF et al (2014) High-speed tracking with kernelized correlation filters. IEEE Trans Pattern Anal Machine Intell 37(3):583\u2013596","journal-title":"IEEE Trans Pattern Anal Machine Intell"},{"issue":"12","key":"5354_CR127","doi-asserted-by":"crossref","first-page":"2481","DOI":"10.1109\/TPAMI.2016.2644615","volume":"39","author":"V Badrinarayanan","year":"2017","unstructured":"Badrinarayanan V, Kendall A, Cipolla R (2017) Segnet: A deep convolutional encoder-decoder architecture for image segmentation. IEEE Trans Pattern Anal Machine Intell 39(12):2481\u20132495","journal-title":"IEEE Trans Pattern Anal Machine Intell"},{"key":"5354_CR128","unstructured":"Simonyan K, Zisserman A (2015) Very Deep Convolutional Networks for Large-Scale Image Recognition, 3rd International Conference on Learning Representations (ICLR 2015), Computational and Biological Learning Society pp 1\u201314"},{"key":"5354_CR129","doi-asserted-by":"publisher","unstructured":"He K, Zhang X, Ren S, Sun J (2016) Deep Residual Learning for Image Recognition, 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), Las Vegas, NV, USA, pp 770\u2013778. https:\/\/doi.org\/10.1109\/CVPR.2016.90","DOI":"10.1109\/CVPR.2016.90"},{"key":"5354_CR130","doi-asserted-by":"publisher","unstructured":"Topiwala A, Al-Zogbi L, Fleiter T, Krieger A (2019) \u201cAdaptation and Evaluation of Deep Learning Techniques for Skin Segmentation on Novel Abdominal Dataset\u201d. In: 2019 IEEE 19th International conference on bioinformatics and bioengineering (BIBE), Athens, Greece, pp 752\u2013759. https:\/\/doi.org\/10.1109\/BIBE.2019.00141","DOI":"10.1109\/BIBE.2019.00141"},{"key":"5354_CR131","doi-asserted-by":"crossref","unstructured":"Krizhevsky A, Sutskever I, Hinton GE (2017) Imagenet classification with deep convolutional neural networks. Commun ACM 60(6):84\u201390","DOI":"10.1145\/3065386"},{"issue":"1","key":"5354_CR132","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1007\/s00421-011-1983-3","volume":"112","author":"H Gesche","year":"2012","unstructured":"Gesche H et al (2012) Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method. European J Appl Physiol 112(1):309\u2013315","journal-title":"European J Appl Physiol"},{"key":"5354_CR133","doi-asserted-by":"publisher","unstructured":"Zhao Y, Huang Z, Gong L, Zhu Y, Yu Q, Gao Y (2023) Evaluating the impact of data transformation techniques on the performance and interpretability of software defect prediction models. IET Software 2023:6293074. https:\/\/doi.org\/10.1049\/2023\/6293074","DOI":"10.1049\/2023\/6293074"},{"issue":"8982","key":"5354_CR134","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/S0140-6736(95)91748-9","volume":"346","author":"JM Bland","year":"1995","unstructured":"Bland JM, Altman DG (1995) Comparing methods of measurement: why plotting difference against standard method is misleading. The Lancet 346(8982):1085\u20131087","journal-title":"The Lancet"},{"key":"5354_CR135","doi-asserted-by":"publisher","first-page":"74736","DOI":"10.1109\/ACCESS.2023.3296382","volume":"11","author":"H Yaacob","year":"2023","unstructured":"Yaacob H, Hossain F, Shari S, Khare SK, Ooi CP, Acharya UR (2023) Application of artificial intelligence techniques for brain-computer interface in mental fatigue detection: A systematic review (2011\u20132022). IEEE Access 11:74736\u201374758. https:\/\/doi.org\/10.1109\/ACCESS.2023.3296382","journal-title":"IEEE Access"},{"key":"5354_CR136","doi-asserted-by":"publisher","unstructured":"Khare SK, March S, Barua PD, Gadre VM, Acharya UR (2023) Application of data fusion for automated detection of children with developmental and mental disorders: A systematic review of the last decade. Inform Fusion 99. https:\/\/doi.org\/10.1016\/j.inffus.2023.101898","DOI":"10.1016\/j.inffus.2023.101898"},{"key":"5354_CR137","doi-asserted-by":"publisher","unstructured":"Khare SK, Acharya UR (2023) Adazd-Net: Automated adaptive and explainable Alzheimer\u2019s disease detection system using EEG signals. Knowl-Based Syst 278. https:\/\/doi.org\/10.1016\/j.knosys.2023.110858","DOI":"10.1016\/j.knosys.2023.110858"},{"key":"5354_CR138","doi-asserted-by":"publisher","unstructured":"Khare SK, Acharya UR (2023) An explainable and interpretable model for attention deficit hyperactivity disorder in children using EEG signals. Comput Biol Med 155. https:\/\/doi.org\/10.1016\/j.compbiomed.2023.106676","DOI":"10.1016\/j.compbiomed.2023.106676"}],"container-title":["Applied Intelligence"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10489-024-05354-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10489-024-05354-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10489-024-05354-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,29]],"date-time":"2024-04-29T13:45:32Z","timestamp":1714398332000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10489-024-05354-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":138,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2024,3]]}},"alternative-id":["5354"],"URL":"https:\/\/doi.org\/10.1007\/s10489-024-05354-9","relation":{},"ISSN":["0924-669X","1573-7497"],"issn-type":[{"value":"0924-669X","type":"print"},{"value":"1573-7497","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3]]},"assertion":[{"value":"20 February 2024","order":1,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2024","order":2,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that th+ere is no Conflict of Interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}]}}