{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T07:20:54Z","timestamp":1740122454881,"version":"3.37.3"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T00:00:00Z","timestamp":1659052800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T00:00:00Z","timestamp":1659052800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61603043"],"award-info":[{"award-number":["61603043"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Auton Robot"],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In breast interventional ultrasound therapy, it is difficult to directly diagnose the location of a tumor in 2-D ultrasound images. To assist surgeons in treatment more intuitively, a four-dimensional ultrasound image-guided breast intervention robot is proposed. The calibration approach of the ultrasonic image for the robot is one of the main contents of the research. This method is based on the establishment of a complete coordinate system conversion model, and it uses the ORB (oriented FAST and rotated BRIEF) feature extraction method to obtain and record the real-time image marker pixel positions, calculate the unknown parameters of the coordinate system conversion matrix, and establish a complete calibration system. This article demonstrates the feasibility of the calibration approach through experiments in our developed US-guided robotic system. Additional experimental and parametrical comparisons of the proposed method with state-of-the-art methods were conducted to thoroughly evaluate the outperformance of the proposed method.\n<\/jats:p>","DOI":"10.1007\/s10514-022-10055-8","type":"journal-article","created":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T13:25:57Z","timestamp":1659101157000},"page":"851-859","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Calibration method for a breast intervention robot based on four-dimensional ultrasound image guidance"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5541-8290","authenticated-orcid":false,"given":"Guo","family":"Yanjun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Duan","family":"Xingguang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wang","family":"Chengyi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhang","family":"Haicheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guo","family":"Huiqin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,29]]},"reference":[{"issue":"10","key":"10055_CR1","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1007\/s11548-015-1341-8","volume":"11","author":"F Aalamifar","year":"2016","unstructured":"Aalamifar, F., Cheng, A., Kim, Y., Hu, X., Zhang, H. K., Guo, X., & Boctor, E. M. (2016). Robot-assisted automatic ultrasound calibration. International Journal of Computer Assisted Radiology and Surgery, 11(10), 1821\u20131829. https:\/\/doi.org\/10.1007\/s11548-015-1341-8","journal-title":"International Journal of Computer Assisted Radiology and Surgery"},{"key":"10055_CR2","doi-asserted-by":"crossref","unstructured":"Carbajal, G., Lasso, A., & G\u00c3\u015fmez \u00c3, Fichtinger G. (2013). Improving n-wire phantom-based freehand ultrasound calibration. International Journal of Computer Assisted Radiology and Surgery, 8(6), 1063\u20131072.","DOI":"10.1007\/s11548-013-0904-9"},{"issue":"23","key":"10055_CR3","doi-asserted-by":"publisher","first-page":"34157","DOI":"10.1007\/s11042-019-08232-6","volume":"78","author":"S Gupta","year":"2019","unstructured":"Gupta, S., Kumar, M., & Garg, A. (2019). Improved object recognition results using sift and orb feature detector. Multimedia Tools and Applications, 78(23), 34157\u201334171. https:\/\/doi.org\/10.1007\/s11042-019-08232-6","journal-title":"Multimedia Tools and Applications"},{"issue":"2","key":"10055_CR4","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1109\/TBCAS.2017.2782815","volume":"12","author":"Q Huang","year":"2018","unstructured":"Huang, Q., Wu, B., Lan, J., & Li, X. (2018). Fully automatic three-dimensional ultrasound imaging based on conventional b-scan. IEEE Transactions on Biomedical Circuits and Systems, 12(2), 426\u2013436. https:\/\/doi.org\/10.1109\/TBCAS.2017.2782815","journal-title":"IEEE Transactions on Biomedical Circuits and Systems"},{"key":"10055_CR5","doi-asserted-by":"crossref","unstructured":"Li, X., Kumar, D., Sarkar, S., & Narayanan, R. (2012) An image registration based ultrasound probe calibration. In: Medical Imaging 2012: Image Processing, February 6, 2012 - February 9, 2012, SPIE, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol 8314, pp Agilent Technologies; Diamond SA; DQE Instruments, Inc.; eMagin; et al.; The Society of Photo\u2013Optical Instrumentation Engineers (SPIE), 10.1117\/12.911461.","DOI":"10.1117\/12.911461"},{"issue":"9","key":"10055_CR6","doi-asserted-by":"publisher","first-page":"2231","DOI":"10.1016\/j.ultrasmedbio.2014.03.006","volume":"40","author":"M Najafi","year":"2014","unstructured":"Najafi, M., Afsham, N., Abolmaesumi, P., & Rohling, R. (2014). A closed-form differential formulation for ultrasound spatial calibration: Multi-wedge phantom. Ultrasound in Medicine and Biology, 40(9), 2231\u20132243. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2014.03.006","journal-title":"Ultrasound in Medicine and Biology"},{"key":"10055_CR7","doi-asserted-by":"crossref","unstructured":"Okwu, M. O., & Tartibu, L. K. (2021) Particle Swarm Optimisation, Springer International Publishing, Cham, pp 5\u201313. 10.1007\/978-3-030-61111-8_2.","DOI":"10.1007\/978-3-030-61111-8_2"},{"issue":"9","key":"10055_CR8","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1016\/S0301-5629(01)00431-8","volume":"27","author":"N Pagoulatos","year":"2001","unstructured":"Pagoulatos, N., Haynor, D. R., & Kim, Y. (2001). A fast calibration method for 3-d tracking of ultrasound images using a spatial localizer. Ultrasound in Medicine and Biology, 27(9), 1219\u20131229. https:\/\/doi.org\/10.1016\/S0301-5629(01)00431-8","journal-title":"Ultrasound in Medicine and Biology"},{"key":"10055_CR9","doi-asserted-by":"crossref","unstructured":"Papenberg, N., Lange, T., Modersitzki, J., Schlag, PM., & Fischer, B. (2008) Image registration for ct and intra-operative ultrasound data of the liver. In: Medical Imaging 2008 - Visualization, Image-Guided Procedures, and Modeling, February 17, 2008 - February 19, 2008, SPIE, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol 6918, p The International Society for Optical Engineering (SPIE), 10.1117\/12.770105.","DOI":"10.1117\/12.770105"},{"key":"10055_CR10","doi-asserted-by":"crossref","unstructured":"Rublee, E., Rabaud, V., Konolige, K., & Bradski, G. (2011) Orb: An efficient alternative to sift or surf. In: 2011 IEEE International Conference on Computer Vision, ICCV 2011, November 6, 2011 - November 13, 2011, Institute of Electrical and Electronics Engineers Inc., Proceedings of the IEEE International Conference on Computer Vision, pp 2564\u20132571, 10.1109\/ICCV.2011.6126544.","DOI":"10.1109\/ICCV.2011.6126544"},{"key":"10055_CR11","doi-asserted-by":"crossref","unstructured":"Solbiati, L., & Tondolo, T. (2013). Imaging of Interventional Therapies in Oncology: Ultrasound, Springer New York, New York, NY, pp 215\u2013230. 10.1007\/978-1-4419-0751-6_15.","DOI":"10.1007\/978-1-4419-0751-6_15"},{"key":"10055_CR12","doi-asserted-by":"crossref","unstructured":"Wang, J., Wu, L., Meng, M. Q. H., & Ren, H. (2014) Towards simultaneous coordinate calibrations for cooperative multiple robots. In: 2014 IEEE\/RSJ International Conference on Intelligent Robots and Systems, IROS 2014, September 14, 2014 - September 18, 2014, Institute of Electrical and Electronics Engineers Inc., IEEE International Conference on Intelligent Robots and Systems, pp 410\u2013415, 10.1109\/IROS.2014.6942592.","DOI":"10.1109\/IROS.2014.6942592"},{"key":"10055_CR13","doi-asserted-by":"publisher","first-page":"8657","DOI":"10.1109\/ACCESS.2018.2791582","volume":"6","author":"L Wang","year":"2018","unstructured":"Wang, L., Wang, T., Liu, H., Hu, L., Han, Z., Liu, W., Guo, N., Qi, Y., & Xu, Y. (2018). An automated calibration method of ultrasonic probe based on coherent point drift algorithm. IEEE Access, 6, 8657\u20138665. https:\/\/doi.org\/10.1109\/ACCESS.2018.2791582","journal-title":"IEEE Access"},{"key":"10055_CR14","doi-asserted-by":"publisher","unstructured":"Xiong, J., Xu, C., Ibrahim, K., Deng, H., & Xia, Z. (2021). A mechanism-image fusion approach to calibration of an ultrasound-guided dual-arm robotic brachytherapy system. IEEE\/ASME Transactions on Mechatronics, 26(6), 3211\u20133220. https:\/\/doi.org\/10.1109\/TMECH.2021.3055902","DOI":"10.1109\/TMECH.2021.3055902"},{"key":"10055_CR15","doi-asserted-by":"crossref","unstructured":"Yi, Q., Zeng, H., Wu, Y., & Huang, S. (2009). A quaternion-based solution of non-linear 3d coordinate transformation parameters. In: 2009 International Conference on Information Engineering and Computer Science, ICIECS 2009, December 19, 2009 - December 20, 2009, IEEE Computer Society, Proceedings - 2009 International Conference on Information Engineering and Computer Science, ICIECS 2009, p Columbia University; et al.; Huazhong Normal University; National Technology University of Ukraine; Wuhan University; Wuhan University of Technology, 10.1109\/ICIECS.2009.5363641.","DOI":"10.1109\/ICIECS.2009.5363641"}],"container-title":["Autonomous Robots"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10514-022-10055-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10514-022-10055-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10514-022-10055-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T13:31:17Z","timestamp":1663594277000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10514-022-10055-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,29]]},"references-count":15,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,10]]}},"alternative-id":["10055"],"URL":"https:\/\/doi.org\/10.1007\/s10514-022-10055-8","relation":{},"ISSN":["0929-5593","1573-7527"],"issn-type":[{"type":"print","value":"0929-5593"},{"type":"electronic","value":"1573-7527"}],"subject":[],"published":{"date-parts":[[2022,7,29]]},"assertion":[{"value":"30 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}