{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,19]],"date-time":"2026-07-19T03:33:36Z","timestamp":1784432016497,"version":"3.55.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2021,11,16]],"date-time":"2021-11-16T00:00:00Z","timestamp":1637020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,11,16]],"date-time":"2021-11-16T00:00:00Z","timestamp":1637020800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100004147","name":"Tsinghua University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004147","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100012515","name":"Cyrus Tang Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100012515","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Intell Robot Syst"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s10846-021-01453-8","type":"journal-article","created":{"date-parts":[[2021,11,16]],"date-time":"2021-11-16T07:02:57Z","timestamp":1637046177000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A Marker-Free 2D Image-Guided Method for Robot-Assisted Fracture Reduction Surgery"],"prefix":"10.1007","volume":"103","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8310-3325","authenticated-orcid":false,"given":"Shijie","family":"Zhu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhe","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiuzheng","family":"Deng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bicong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianjin","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yitong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dawei","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0456-9523","authenticated-orcid":false,"given":"Yongwei","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7479-3301","authenticated-orcid":false,"given":"Gangtie","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,11,16]]},"reference":[{"issue":"Suppl 3","key":"1453_CR1","doi-asserted-by":"publisher","first-page":"S135","DOI":"10.1097\/BOT.0b013e318237b2eb","volume":"25","author":"TA Russell","year":"2011","unstructured":"Russell, T.A.: Intramedullary nailing: evolutions of femoral intramedullary nailing: first to fourth generations. J. Orthop. Trauma. 25(Suppl 3), S135\u2013S138 (2011). https:\/\/doi.org\/10.1097\/BOT.0b013e318237b2eb","journal-title":"J. Orthop. Trauma"},{"issue":"4","key":"1453_CR2","doi-asserted-by":"publisher","first-page":"529","DOI":"10.2106\/00004623-198466040-00006","volume":"66","author":"RA Winquist","year":"1984","unstructured":"Winquist, R.A., Hansen Jr., S.T., Clawson, D.K.: Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J Bone Joint Surg-Am. 66(4), 529\u2013539 (1984)","journal-title":"J Bone Joint Surg-Am"},{"key":"1453_CR3","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1007\/978-3-642-56330-0_7","volume-title":"Practice of Intramedullary Locked Nails","author":"JC Dosch","year":"2002","unstructured":"Dosch, J.C., Dupuis, M.G.: Time of radiation exposure during intramedullary nailing procedures. In: Kempf, I., Leung, K.S., Grosse, A., Haarman, H.J.T.M., Seidel, H., Taglang, G. (eds.) Practice of Intramedullary Locked Nails, pp. 61\u201365. Springer (2002). https:\/\/doi.org\/10.1007\/978-3-642-56330-0_7"},{"key":"1453_CR4","doi-asserted-by":"publisher","unstructured":"Zhu, Q., Sun, X., Wang, X., Wu, Q., Liang, B.: Development of intraoperative noninvasive force measuring system during femoral fracture reduction. In: Proc. IEEE Int. Symp. Medical Measurements and Applications, 2015, 7\u20139 May 2015 2015. Proc. IEEE Int. Symp. Medical Measurements and Applications. pp. 335\u2013339 (2015) doi:https:\/\/doi.org\/10.1109\/MeMeA.2015.7145223","DOI":"10.1109\/MeMeA.2015.7145223"},{"issue":"10","key":"1453_CR5","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1177\/0278364909101189","volume":"28","author":"R Westphal","year":"2009","unstructured":"Westphal, R., Winkelbach, S., Wahl, F., Gosling, T., Oszwald, M., Hufner, T., Krettek, C.: Robot-assisted long bone fracture reduction. Int. J. Robot. Res. 28(10), 1259\u20131278 (2009). https:\/\/doi.org\/10.1177\/0278364909101189","journal-title":"Int. J. Robot. Res."},{"issue":"9","key":"1453_CR6","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1002\/jor.21118","volume":"28","author":"M Oszwald","year":"2010","unstructured":"Oszwald, M., Westphal, R., Bredow, J., Calafi, A., Hufner, T., Wahl, F., Krettek, C., Gosling, T.: Robot-assisted fracture reduction using three-dimensional intraoperative fracture visualization: an experimental study on human cadaver femora. J. Orthop. Res. 28(9), 1240\u20131244 (2010). https:\/\/doi.org\/10.1002\/jor.21118","journal-title":"J. Orthop. Res."},{"issue":"3","key":"1453_CR7","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1002\/rcs.1614","volume":"11","author":"H Du","year":"2014","unstructured":"Du, H., Hu, L., Li, C., Wang, T., Zhao, L., Li, Y., Mao, Z., Liu, D., Zhang, L., He, C.: Advancing computer-assisted orthopaedic surgery using a hexapod device for closed diaphyseal fracture reduction. Int. J. Med. Robot. Comput. Assist. Surg. 11(3), 348\u2013359 (2014)","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"issue":"1","key":"1453_CR8","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1002\/rcs.1573","volume":"11","author":"H Du","year":"2015","unstructured":"Du, H., Hu, L., Li, C., He, C., Zhang, L., Tang, P.: Preoperative trajectory planning for closed reduction of long-bone diaphyseal fracture using a computer-assisted reduction system. Int. J. Med. Robot. Comput. Assist. Surg. 11(1), 58\u201366 (2015). https:\/\/doi.org\/10.1002\/rcs.1573","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"issue":"2","key":"1453_CR9","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1967","volume":"15","author":"WY Kim","year":"2019","unstructured":"Kim, W.Y., Ko, S.Y.: Hands-on robot-assisted fracture reduction system guided by a linear guidance constraints controller using a pre-operatively planned goal pose. Int. J. Med. Robot. Comput. Assist. Surg. 15(2), e1967 (2019). https:\/\/doi.org\/10.1002\/rcs.1967","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"key":"1453_CR10","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.mechatronics.2016.02.005","volume":"35","author":"WY Kim","year":"2016","unstructured":"Kim, W.Y., Ko, S.Y., Park, J.O., Park, S.: 6-DOF force feedback control of robot-assisted bone fracture reduction system using double F\/T sensors and adjustable admittances to protect bones against damage. Mechatronics. 35, 136\u2013147 (2016). https:\/\/doi.org\/10.1016\/j.mechatronics.2016.02.005","journal-title":"Mechatronics"},{"issue":"16","key":"1453_CR11","doi-asserted-by":"publisher","first-page":"3593","DOI":"10.3390\/s19163593","volume":"19","author":"L Bai","year":"2019","unstructured":"Bai, L., Yang, J., Chen, X., Sun, Y., Li, X.: Medical robotics in bone fracture reduction surgery: a review. Sensors-Basel. 19(16), 3593 (2019)","journal-title":"Sensors-Basel"},{"key":"1453_CR12","doi-asserted-by":"publisher","unstructured":"Hoeckelmann, M., Rudas, I.J., Fiorini, P., Kirchner, F., Haidegger, T.: Current capabilities and development potential in surgical robotics. Int. J. Adv. Robot. Syst. 12 (61) (2015) doi: https:\/\/doi.org\/10.5772\/60133","DOI":"10.5772\/60133"},{"issue":"1","key":"1453_CR13","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1007\/s10439-019-02332-y","volume":"48","author":"J-X Zhao","year":"2019","unstructured":"Zhao, J.-X., Li, C., Ren, H., Hao, M., Zhang, L.-C., Tang, P.-F.: Evolution and current applications of robot-assisted fracture reduction: a comprehensive review. Ann. Biomed. Eng. 48(1), 203\u2013224 (2019). https:\/\/doi.org\/10.1007\/s10439-019-02332-y","journal-title":"Ann. Biomed. Eng."},{"key":"1453_CR14","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1080\/24699322.2017.1379254","volume":"22","author":"L Wang","year":"2017","unstructured":"Wang, L., Wang, T., Tang, P., Hu, L., Liu, W., Han, Z., Hao, M., Liu, H., Wang, K., Zhao, Y., Guo, N., Cao, Y., Li, C.: A new hand-eye calibration approach for fracture reduction robot. Comput. Assist. Surg. 22, 113\u2013119 (2017). https:\/\/doi.org\/10.1080\/24699322.2017.1379254","journal-title":"Comput. Assist. Surg."},{"issue":"1","key":"1453_CR15","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1002\/rcs.240","volume":"5","author":"T Leloup","year":"2010","unstructured":"Leloup, T., Kazzi, W.E., Schuind, F., Warz\u00e9e, N.: Conception of a navigation system controlling diaphyseal fracture reduction treated with external fixation. Int. J. Med. Robot Comput. Assist. Surg. 5(1), 99\u2013109 (2010)","journal-title":"Int. J. Med. Robot Comput. Assist. Surg."},{"issue":"10","key":"1453_CR16","doi-asserted-by":"publisher","first-page":"1831","DOI":"10.1007\/s11548-016-1418-z","volume":"11","author":"G Dagnino","year":"2016","unstructured":"Dagnino, G., Georgilas, I., K\u00f6hler, P., Morad, S., Atkins, R., Dogramadzi, S.: Navigation system for robot-assisted intra-articular lower-limb fracture surgery. Int. J. Comput. Assist. Radiol. Surg. 11(10), 1831\u20131843 (2016). https:\/\/doi.org\/10.1007\/s11548-016-1418-z","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"issue":"11","key":"1453_CR17","doi-asserted-by":"publisher","first-page":"2648","DOI":"10.1007\/s10439-017-1901-x","volume":"45","author":"G Dagnino","year":"2017","unstructured":"Dagnino, G., Georgilas, I., Morad, S., Gibbons, P., Tarassoli, P., Atkins, R., Dogramadzi, S.: Image-guided surgical robotic system for percutaneous reduction of joint fractures. Ann. Biomed. Eng. 45(11), 2648\u20132662 (2017)","journal-title":"Ann. Biomed. Eng."},{"issue":"10","key":"1453_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10439-018-2005-y","volume":"46","author":"I Georgilas","year":"2018","unstructured":"Georgilas, I., Dagnino, G., Tarassoli, P., Atkins, R., Dogramadzi, S.: Robot-assisted fracture surgery: surgical requirements and system design. Ann. Biomed. Eng. 46(10), 1\u201313 (2018). https:\/\/doi.org\/10.1007\/s10439-018-2005-y","journal-title":"Ann. Biomed. Eng."},{"key":"1453_CR19","doi-asserted-by":"crossref","unstructured":"Zhu, S., Chen, Y., Chen, Y., Sun, J., Zhao, Z., Hu, C., Zheng, G. A. Noninvasive Calibration-Free and Model-Free Surgical Robot for Automatic Fracture Reduction. In: Proc. Int. Conf. Intelligent Robotics and Applications, 2019, 2019. Proc. Int. Conf. Intelligent Robotics and Applications. Springer, pp 285\u2013296 (2019)","DOI":"10.1007\/978-3-030-27529-7_25"},{"key":"1453_CR20","doi-asserted-by":"publisher","unstructured":"Hao, M., Sun, Z., Fujii, M., Song, W. Uncalibrated eye-in-hand visual servoing using recursive least squares. In: Proc. IEEE Int. Conf. Systems, Man and Cybernetics, 2007, 2007. Proc. IEEE Int. Conf. Systems, Man and Cybernetics (2007). IEEE, pp 64\u201369. doi:https:\/\/doi.org\/10.1109\/WCICA.2008.4593061","DOI":"10.1109\/WCICA.2008.4593061"},{"key":"1453_CR21","doi-asserted-by":"crossref","unstructured":"Hao, M., Deuflhard, P., Sun, Z., Fujii, M.: Model-free uncalibrated visual Servoing using recursive least squares. J. Comput. 3(11), (2008)","DOI":"10.4304\/jcp.3.11.42-50"},{"issue":"5","key":"1453_CR22","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1109\/Tmech.2011.2131149","volume":"17","author":"M Hao","year":"2012","unstructured":"Hao, M., Sun, Z.Q.: A universal state-space approach to uncalibrated model-free visual Servoing. IEEE-ASME Trans. Mechatron. 17(5), 833\u2013846 (2012). https:\/\/doi.org\/10.1109\/Tmech.2011.2131149","journal-title":"IEEE-ASME Trans. Mechatron."},{"key":"1453_CR23","doi-asserted-by":"crossref","unstructured":"Hosoda K, Asada M Versatile visual servoing without knowledge of true jacobian. In: Proc. IEEE\/RSJ Int. Conf. Intelligent Robots and Systems, 1994, 1994. Proc. IEEE\/RSJ Int. Conf. Intelligent Robots and Systems. pp. 186\u2013193 (1994)","DOI":"10.1109\/IROS.1994.407392"},{"issue":"4","key":"1453_CR24","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1109\/MRA.2006.250573","volume":"13","author":"F Chaumette","year":"2006","unstructured":"Chaumette, F., Hutchinson, S.: Visual servo control. I. Basic approaches. IEEE Robot. Autom. Magazine. 13(4), 82\u201390 (2006)","journal-title":"IEEE Robot. Autom. Magazine"},{"issue":"1","key":"1453_CR25","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1109\/MRA.2007.339609","volume":"14","author":"F Chaumette","year":"2007","unstructured":"Chaumette, F., Hutchinson, S.: Visual servo control. II. Advanced approaches. IEEE Robot. Autom. Magazine. 14(1), 109\u2013118 (2007)","journal-title":"IEEE Robot. Autom. Magazine"},{"issue":"3","key":"1453_CR26","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/S0921-8890(97)00052-3","volume":"23","author":"H Sutanto","year":"1998","unstructured":"Sutanto, H., Sharma, R., Varma, V.: The role of exploratory movement in visual servoing without calibration. Robot. Auton. Syst. 23(3), 153\u2013169 (1998). https:\/\/doi.org\/10.1016\/S0921-8890(97)00052-3","journal-title":"Robot. Auton. Syst."},{"issue":"3","key":"1453_CR27","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1109\/Tmech.2008.924135","volume":"13","author":"M Bonkovic","year":"2008","unstructured":"Bonkovic, M., Hace, A., Jezernik, K.: Population-based uncalibrated visual servoing. IEEE-ASME Trans. Mechatron. 13(3), 393\u2013397 (2008). https:\/\/doi.org\/10.1109\/Tmech.2008.924135","journal-title":"IEEE-ASME Trans. Mechatron."},{"issue":"1","key":"1453_CR28","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1109\/Tra.2003.820923","volume":"20","author":"JA Piepmeier","year":"2004","unstructured":"Piepmeier, J.A., McMurray, G.V., Lipkin, H.: Uncalibrated dynamic visual servoing. IEEE Trans. Robot. Autom. 20(1), 143\u2013147 (2004). https:\/\/doi.org\/10.1109\/Tra.2003.820923","journal-title":"IEEE Trans. Robot. Autom."},{"key":"1453_CR29","first-page":"568","volume":"561","author":"JA Piepmeier","year":"2002","unstructured":"Piepmeier, J.A., Gumpert, B.A., Lipkin, H.: Uncalibrated Eye-in-Hand Visual Servoing. In: Proc. IEEE Int. Conf. Robotics and Automation, 2002, 2002. Proc. IEEE Int. Conf. Robotics and Automation. 561, 568\u2013573 (2002)","journal-title":"Proc. IEEE Int. Conf. Robotics and Automation"},{"key":"1453_CR30","unstructured":"Qian JA, Su JB Online estimation of image Jacobian matrix by Kalman-Bucy filter for uncalibrated stereo vision feedback. In: Proc. IEEE Int. Conf. Robotics and Automation, 2002, 2002. Proc. IEEE Int. Conf. Robotics and Automation, 2002. pp. 562\u2013567"},{"key":"1453_CR31","doi-asserted-by":"publisher","unstructured":"Burenius, M., Sullivan, J., Carlsson, S.: Motion capture from dynamic orthographic cameras. In: 2011 IEEE International Conference on Computer Vision Workshops (ICCV Workshops), 6\u201313 Nov. 2011 (2011). pp 1634\u20131641. doi:https:\/\/doi.org\/10.1109\/ICCVW.2011.6130445","DOI":"10.1109\/ICCVW.2011.6130445"},{"issue":"92","key":"1453_CR32","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1090\/S0025-5718-1965-0198670-6","volume":"19","author":"CG Broyden","year":"1965","unstructured":"Broyden, C.G.: A Class of Methods for Solving Nonlinear Simultaneous Equations. Math Comput. 19(92), 557 (1965)","journal-title":"Math Comput"},{"issue":"6","key":"1453_CR33","doi-asserted-by":"publisher","first-page":"1457","DOI":"10.1109\/Tro.2013.2275651","volume":"29","author":"D Navarro-Alarcon","year":"2013","unstructured":"Navarro-Alarcon, D., Liu, Y.H., Romero, J.G.: Model-free visually Servoed deformation control of elastic objects by robot manipulators. IEEE T Robot. 29(6), 1457\u20131468 (2013). https:\/\/doi.org\/10.1109\/Tro.2013.2275651","journal-title":"IEEE T Robot."},{"key":"1453_CR34","doi-asserted-by":"publisher","unstructured":"Qingjie, Z., Liqun, Z., Yunjiao, C.: Online estimation technique for Jacobian matrix in robot visual servo systems. In: 2008 3rd IEEE Conference on Industrial Electronics and Applications, 3\u20135 June 2008 2008. pp 1270\u20131275. doi:https:\/\/doi.org\/10.1109\/ICIEA.2008.4582722","DOI":"10.1109\/ICIEA.2008.4582722"},{"issue":"11","key":"1453_CR35","doi-asserted-by":"publisher","first-page":"5094","DOI":"10.1002\/mp.13210","volume":"45","author":"G Xiao","year":"2018","unstructured":"Xiao, G., Bonmati, E., Thompson, S., Evans, J., Hipwell, J., Nikitichev, D., Gurusamy, K., Ourselin, S., Hawkes, D.J., Davidson, B., Clarkson, M.J.: Electromagnetic tracking in image-guided laparoscopic surgery: comparison with optical tracking and feasibility study of a combined laparoscope and laparoscopic ultrasound system. Med. Phys. 45(11), 5094\u20135104 (2018). https:\/\/doi.org\/10.1002\/mp.13210","journal-title":"Med. Phys."},{"issue":"3","key":"1453_CR36","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1016\/j.injury.2017.01.019","volume":"48","author":"J-W Kim","year":"2017","unstructured":"Kim, J.-W., Oh, C.-W., Oh, J.-K., Park, I.-H., Kyung, H.-S., Park, K.-H., Yoon, S.-D., Kim, S.-M.: Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures. Injury. 48(3), 751\u2013757 (2017). https:\/\/doi.org\/10.1016\/j.injury.2017.01.019","journal-title":"Injury"}],"container-title":["Journal of Intelligent &amp; Robotic Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10846-021-01453-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10846-021-01453-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10846-021-01453-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T07:25:16Z","timestamp":1726125916000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10846-021-01453-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,16]]},"references-count":36,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1453"],"URL":"https:\/\/doi.org\/10.1007\/s10846-021-01453-8","relation":{},"ISSN":["0921-0296","1573-0409"],"issn-type":[{"value":"0921-0296","type":"print"},{"value":"1573-0409","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,16]]},"assertion":[{"value":"2 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 November 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. This research doesn\u2019t involve human or animal subjects, their data or biological material.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Approval"}},{"value":"Not applicable. This research doesn\u2019t involve human subjects.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Participate"}},{"value":"Not applicable. This research doesn\u2019t contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to Publish"}},{"value":"The authors have a patent application (US20190125461A1) based on the method described in this paper.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of Interest"}}],"article-number":"67"}}