{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T13:40:12Z","timestamp":1762954812851,"version":"3.37.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2009,1,28]],"date-time":"2009-01-28T00:00:00Z","timestamp":1233100800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Med Syst"],"published-print":{"date-parts":[[2010,6]]},"DOI":"10.1007\/s10916-008-9245-6","type":"journal-article","created":{"date-parts":[[2009,1,27]],"date-time":"2009-01-27T13:08:00Z","timestamp":1233061680000},"page":"331-339","source":"Crossref","is-referenced-by-count":35,"title":["Morphology Variability Analysis of Wrist Pulse Waveform for Assessment of Arteriosclerosis Status"],"prefix":"10.1007","volume":"34","author":[{"given":"Lisheng","family":"Xu","sequence":"first","affiliation":[]},{"given":"Max Q.-H.","family":"Meng","sequence":"additional","affiliation":[]},{"given":"Xianghua","family":"Qi","sequence":"additional","affiliation":[]},{"given":"Kuanquan","family":"Wang","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2009,1,28]]},"reference":[{"key":"9245_CR1","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0967-3334\/28\/3\/R01","volume":"28","author":"J. Allen","year":"2007","unstructured":"Allen, J., Photoplethysmography and its application in clinical physiological measurement. Physiol. Meas. 28:R1\u2013R39, 2007. doi: 10.1088\/0967-3334\/28\/3\/R01 .","journal-title":"Physiol. Meas"},{"key":"9245_CR2","unstructured":"Amber, R. B., Pulse diagnosis: detailed interpretations for Eastern & Western holistic treatments, Aurora, 1993."},{"issue":"1","key":"9245_CR3","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1109\/51.740985","volume":"18","author":"W. A. Lu","year":"1999","unstructured":"Lu, W. A., Wang, Y. Y. L., and Wang, W. K., Pulse analysis of patients with sever liver problems. IEEE Eng. Med. Biol. 18(1):73\u201375, 1999. doi: 10.1109\/51.740985 .","journal-title":"IEEE Eng. Med. Biol"},{"key":"9245_CR4","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1046\/j.0306-5251.2001.01400.x","volume":"51","author":"M. F. O\u2019Rourke","year":"2001","unstructured":"O\u2019Rourke, M. F., et al., Pulse wave analysis. Br. J. Clin. Pharmacol. 51:507\u2013522, 2001. doi: 10.1046\/j.0306-5251.2001.01400.x .","journal-title":"Br. J. Clin. Pharmacol"},{"key":"9245_CR5","doi-asserted-by":"crossref","unstructured":"Yoon, Y. Z., Lee, M. H., and Soh, K. S., Pulse type classification by varying contact pressure, IEEE Engineering in Medicine and Biology, pp. 106\u2013110, 2000.","DOI":"10.1109\/51.887253"},{"issue":"5","key":"9245_CR6","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1016\/j.compbiomed.2006.06.014","volume":"37","author":"L. S. Xu","year":"2007","unstructured":"Xu, L. S., et al., Baseline wander correction in pulse waveforms using wavelet-based cascaded adaptive filter. Comput. Biol. Med. 37(5):716\u2013731, 2007. doi: 10.1016\/j.compbiomed.2006.06.014 .","journal-title":"Comput. Biol. Med"},{"key":"9245_CR7","doi-asserted-by":"crossref","unstructured":"Aritomo, M., Yonezawa, Y., A wrist-mounted activity and pulse recording system, In Proceedings of the First Joint BMES\/EMBS Conference Serving Humanity, Advancing Technology, pp. 693, Oct 1999.","DOI":"10.1109\/IEMBS.1999.803848"},{"issue":"6","key":"9245_CR8","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1109\/TBME.1983.325136","volume":"30","author":"C. T. Lee","year":"1983","unstructured":"Lee, C. T., and Wei, L. Y., Spectrum analysis of human pulse. IEEE Trans. Biomed. Eng. 30(6):348\u2013352, 1983. doi: 10.1109\/TBME.1983.325136 .","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"9245_CR9","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.1161\/01.CIR.80.6.1652","volume":"80","author":"R. Kelly","year":"1989","unstructured":"Kelly, R., Hayward, C., Avolio, A., and O\u2019Rourke, M., Noninvasive determination of age-related changes in the human arterial pulse. Circulation. 80:1652\u20131659, 1989.","journal-title":"Circulation"},{"issue":"3-4","key":"9245_CR10","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1142\/S0192415X86000296","volume":"14","author":"S. H. Yoon","year":"1986","unstructured":"Yoon, S. H., Koga, Y., Matsumoto, I., and Ikezono, E., Clinical study of objective pulse diagnosis. Am. J. Chin. Med. 14(3-4):179\u2013183, 1986.","journal-title":"Am. J. Chin. Med"},{"issue":"7","key":"9245_CR11","doi-asserted-by":"crossref","first-page":"662","DOI":"10.1109\/TBME.2002.1010849","volume":"49","author":"M. A. Navakatikyan","year":"2002","unstructured":"Navakatikyan, M. A., Barrett, C. J., Head, G. A., Ricketts, J. H., and Malpas, S. C., A real-time algorithm for the quantification of blood pressure waveforms. IEEE Trans. Biomed. Eng. 49(7):662\u2013670, 2002. doi: 10.1109\/TBME.2002.1010849 .","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"9245_CR12","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/BF02077634","volume":"12","author":"W. B. Murray","year":"1996","unstructured":"Murray, W. B., and Foster, P. A., The peripheral pulse wave: information overlook. J. Clin. Monit. 12:365\u2013377, 1996. doi: 10.1007\/BF02077634 .","journal-title":"J. Clin. Monit"},{"issue":"5","key":"9245_CR13","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/s10916-007-9074-z","volume":"31","author":"J. Y. Lee","year":"2007","unstructured":"Lee, J. Y., The study on the intellectual analysis algorithm for oriental pulse parameters. J. Med. Syst. 31(5):345\u2013349, 2007. doi: 10.1007\/s10916-007-9074-z .","journal-title":"J. Med. Syst"},{"issue":"2","key":"9245_CR14","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1038\/sj.jhh.1001517","volume":"17","author":"J. E. Naschitz","year":"2003","unstructured":"Naschitz, J. E., Itzhak, R., Shaviv, N., et al., Assessment of cardiovascular reactivity by fractal and recurrence quantification analysis of heart rate and pulse transit time. J. Hum. Hypertens. 17(2):111\u2013118, 2003. doi: 10.1038\/sj.jhh.1001517 .","journal-title":"J. Hum. Hypertens"},{"key":"9245_CR15","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/0167-2789(85)90011-9","volume":"16","author":"A. Wolf","year":"1985","unstructured":"Wolf, A., Swift, J. B., Swinney, H. L., and Vastano, J. A., Determining Lyapunov exponenets from a time-series. Physica D. 16:285\u2013317, 1985. doi: 10.1016\/0167-2789(85)90011-9 .","journal-title":"Physica D"},{"issue":"1","key":"9245_CR16","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1023\/A:1026507317626","volume":"10","author":"R. Seker","year":"2000","unstructured":"Seker, R., Saliu, S., Birand, A., and Kudaiberdieva, G., Validity test for a set of nonlinear measures for short data length with reference to short-term heart rate variability signal. J. Syst. Integration. 10(1):41\u201353, 2000. doi: 10.1023\/A:1026507317626 .","journal-title":"J. Syst. Integration"},{"key":"9245_CR17","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1063\/1.166092","volume":"5","author":"S. Pincus","year":"1995","unstructured":"Pincus, S., Approximate entropy (ApEn) as a complexity measure. Chaos. 5:110\u2013117, 1995. doi: 10.1063\/1.166092 .","journal-title":"Chaos"},{"issue":"5","key":"9245_CR18","doi-asserted-by":"crossref","first-page":"E741","DOI":"10.1152\/ajpendo.1992.262.5.E741","volume":"25","author":"S. M. Pincus","year":"1992","unstructured":"Pincus, S. M., and Keefe, D. L., Quantification of hormone pulsatility via an approximate entropy algorithm. Am. J. Physiol. Endocrinol. Metab. 25(5):E741\u2013E754, 1992.","journal-title":"Am. J. Physiol. Endocrinol. Metab"},{"key":"9245_CR19","unstructured":"Wang, K. Q., Xu, L. S., and Zhang, D., Approximate entropy based pulse variability analysis, In Proceedings of the IEEE Symposium on Computer-Based Medical Systems pp. 236\u2013241, 2003."},{"key":"9245_CR20","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.1161\/01.HYP.33.6.1392","volume":"33","author":"E. M. Gary","year":"1999","unstructured":"Gary, E. M., Christopher, W. B., Dennis, J. M., Cheryl, M. A., Stephen, P. G., Stanley, M. F., and Jay, N. C., Age-related abnormalities in arterial compliance identified by pressure pulse contour analysis: aging and arterial compliance. Hypertension. 33:1392\u20131398, 1999.","journal-title":"Hypertension"},{"key":"9245_CR21","first-page":"5568","volume-title":"Extraction of photoplethysmographic waveform variability by lowpass filtering","author":"G. S. H. Chan","year":"2005","unstructured":"Chan, G. S. H., Middleton, P. M., Lovell, N. H., and Celler, B. G., Extraction of photoplethysmographic waveform variability by lowpass filtering. Proceedings of the 27th Annual Conference on IEEE Engineering in Medicine and Biology, Shanghai, China, 2005. pp 5568\u20135571, September 1\u20134."},{"key":"9245_CR22","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1161\/01.ATV.0000060460.52916.D6","volume":"23","author":"J. J. Oliver","year":"2003","unstructured":"Oliver, J. J., and Webb, D. J., Noninvasive assessment of arterial stiffness and risk of atherosclerotic events. Arterioscler. Thromb. Vasc. Biol. 23:554\u2013566, 2003. doi: 10.1161\/01.ATV.0000060460.52916.D6 .","journal-title":"Arterioscler. Thromb. Vasc. Biol"},{"key":"9245_CR23","volume-title":"McDonald\u2019s Blood Flow in Arteries","author":"W. W. Nichols","year":"2005","unstructured":"Nichols, W. W., and O\u2019Rourke, M. F., McDonald\u2019s Blood Flow in Arteries, 5th edition. Hodder Arnold, London, 2005.","edition":"5th"},{"issue":"11","key":"9245_CR24","doi-asserted-by":"crossref","first-page":"3061","DOI":"10.1080\/03610929208830963","volume":"21","author":"S. M. Pincus","year":"1992","unstructured":"Pincus, S. M., and Huang, W. M., Approximate entropy: statistical properties and applications. Comm. Statist. Theory Methods. 21(11):3061\u20133077, 1992. doi: 10.1080\/03610929208830963 .","journal-title":"Comm. Statist. Theory Methods"},{"issue":"5","key":"9245_CR25","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1161\/01.CIR.93.5.1043","volume":"93","author":"M. Malik","year":"1996","unstructured":"Malik, M., et al., Heart rate variability, standards of measurement, physiological interpretation, and clinical use, Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Circulation. 93(5):1043\u20131065, 1996.","journal-title":"Circulation"},{"key":"9245_CR26","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1109\/10.43620","volume":"37","author":"G. M. Friesen","year":"1990","unstructured":"Friesen, G. M., Jannett, T. C., Manal, A. J., et al., A comparison of the noise sensitivity of nine QRS detection algorithms. IEEE Trans. Biomed. Eng. 37:85\u201398, 1990. doi: 10.1109\/10.43620 .","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"9245_CR27","doi-asserted-by":"crossref","unstructured":"Xu L. S., Zhang D., Wang K. Q., and Wang L., Arrhythmic pulses detection using Lempel-Ziv complexity analysis, EURASIP Journal on Applied Signal Processing 2006 Article ID 18268, 12 pages, 2006.","DOI":"10.1155\/ASP\/2006\/18268"},{"key":"9245_CR28","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1539\/joh.39.154","volume":"39","author":"K. Takayuki","year":"1997","unstructured":"Takayuki, K., Michinori, K., Tetsuya, K., and Noriko, N., Accuracy of pulse rate variability parameters obtained from finger plethysmogram: a comparison with heart rate variability parameters obtained from ECG. J. Occup. Health. 39:154\u2013155, 1997. doi: 10.1539\/joh.39.154 .","journal-title":"J. Occup. Health"},{"key":"9245_CR29","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1161\/01.HYP.25.6.1276","volume":"25","author":"G. Parati","year":"1995","unstructured":"Parati, G., Saul, J. P., Di Rienzo, M., and Mancia, G., Spectral analysis of blood pressure and heart rate variability in evaluating cardiovascular regulation. Hypertension. 25:1276\u20131286, 1995.","journal-title":"Hypertension"}],"container-title":["Journal of Medical Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-008-9245-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10916-008-9245-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-008-9245-6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,7]],"date-time":"2025-02-07T07:49:24Z","timestamp":1738914564000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10916-008-9245-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1,28]]},"references-count":29,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2010,6]]}},"alternative-id":["9245"],"URL":"https:\/\/doi.org\/10.1007\/s10916-008-9245-6","relation":{},"ISSN":["0148-5598","1573-689X"],"issn-type":[{"type":"print","value":"0148-5598"},{"type":"electronic","value":"1573-689X"}],"subject":[],"published":{"date-parts":[[2009,1,28]]}}}