{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,2,19]],"date-time":"2023-02-19T17:09:46Z","timestamp":1676826586887},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2010,5,8]],"date-time":"2010-05-08T00:00:00Z","timestamp":1273276800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Med Syst"],"published-print":{"date-parts":[[2011,10]]},"DOI":"10.1007\/s10916-010-9507-y","type":"journal-article","created":{"date-parts":[[2010,5,7]],"date-time":"2010-05-07T04:05:13Z","timestamp":1273205113000},"page":"905-919","source":"Crossref","is-referenced-by-count":13,"title":["Inter-Greedy Technique for Fusion of Different Segmentation Strategies Leading to High-Performance Carotid IMT Measurement in Ultrasound Images"],"prefix":"10.1007","volume":"35","author":[{"given":"Filippo","family":"Molinari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guang","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jasjit S.","family":"Suri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2010,5,8]]},"reference":[{"issue":"1","key":"9507_CR1","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1159\/000097034","volume":"23","author":"PJ Touboul","year":"2007","unstructured":"Touboul, P. J., Hennerici, M. G., Meairs, S., et al., Mannheim carotid intima-media thickness consensus (2004\u20132006). An update on behalf of the Advisory Board of the 3rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006. Cerebrovasc Dis 23(1):75\u201380, 2007.","journal-title":"Cerebrovasc Dis"},{"issue":"4","key":"9507_CR2","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1159\/000081812","volume":"18","author":"PJ Touboul","year":"2004","unstructured":"Touboul, P. J., Hennerici, M. G., Meairs, S., et al., Mannheim intima-media thickness consensus. Cerebrovasc Dis 18(4):346\u20139, 2004.","journal-title":"Cerebrovasc Dis"},{"issue":"9","key":"9507_CR3","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1161\/01.CIR.0000120708.59903.1B","volume":"109","author":"IM Meer van der","year":"2004","unstructured":"van der Meer, I. M., Bots, M. L., Hofman, A., et al., Predictive value of noninvasive measures of atherosclerosis for incident myocardial infarction: the Rotterdam Study. Circulation 109(9):1089\u201394, 2004.","journal-title":"Circulation"},{"issue":"3","key":"9507_CR4","first-page":"166","volume":"32","author":"P Pignoli","year":"1988","unstructured":"Pignoli, P., and Longo, T., Evaluation of atherosclerosis with B-mode ultrasound imaging. J Nucl Med Allied Sci 32(3):166\u201373, 1988.","journal-title":"J Nucl Med Allied Sci"},{"key":"9507_CR5","first-page":"6468","volume":"6","author":"S Delsanto","year":"2005","unstructured":"Delsanto, S., Molinari, F., Giustetto, P., et al., CULEX-completely user-independent layers extraction: ultrasonic carotid artery images segmentation. Conf Proc IEEE Eng Med Biol Soc 6:6468\u201371, 2005.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"issue":"4","key":"9507_CR6","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1109\/TIM.2007.900433","volume":"56","author":"S Delsanto","year":"2007","unstructured":"Delsanto, S., Molinari, F., Giustetto, P., et al., Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images. Instrumentation and Measurement, IEEE Transactions on 56(4):1265\u20131274, 2007.","journal-title":"Instrumentation and Measurement, IEEE Transactions on"},{"key":"9507_CR7","doi-asserted-by":"crossref","first-page":"2404","DOI":"10.1109\/IEMBS.2006.260673","volume":"1","author":"S Delsanto","year":"2006","unstructured":"Delsanto, S., Molinari, F., Liboni, W., et al., User-independent plaque characterization and accurate IMT measurement of carotid artery wall using ultrasound. Conf Proc IEEE Eng Med Biol Soc 1:2404\u20137, 2006.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"9507_CR8","unstructured":"F. Molinari, G. Zeng, and J. S. Suri, An integrated approach to computer\u2013based automated tracing and its validation for common carotid arterial wall ultrasound images: A new technique. J Ultras Med 29:399\u2013418, 2010."},{"key":"9507_CR9","unstructured":"F. Molinari, G. Zeng, and J. S. Suri, Intima-media thickness: setting a standard for a completely automated method of ultrasound. IEEE Transaction on Ultrasonics Ferroelectrics and Frequency Control 57(5):1112\u20131124, 2010."},{"issue":"9","key":"9507_CR10","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.7863\/jum.2008.27.9.1353","volume":"27","author":"F Faita","year":"2008","unstructured":"Faita, F., Gemignani, V., Bianchini, E., et al., Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator. J Ultrasound Med 27(9):1353\u201361, 2008.","journal-title":"J Ultrasound Med"},{"issue":"3","key":"9507_CR11","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.echo.2004.12.002","volume":"18","author":"JH Stein","year":"2005","unstructured":"Stein, J. H., Korcarz, C. E., Mays, M. E., et al., A semiautomated ultrasound border detection program that facilitates clinical measurement of ultrasound carotid intima-media thickness. J Am Soc Echocardiogr 18(3):244\u201351, 2005.","journal-title":"J Am Soc Echocardiogr"},{"issue":"2","key":"9507_CR12","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1109\/42.836372","volume":"19","author":"Q Liang","year":"2000","unstructured":"Liang, Q., Wendelhag, I., Wikstrand, J., et al., A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images. IEEE Trans Med Imaging 19(2):127\u201342, 2000.","journal-title":"IEEE Trans Med Imaging"},{"key":"9507_CR13","doi-asserted-by":"crossref","DOI":"10.1109\/ISBI.2010.5490340","volume-title":"Carotid wall segmentation and IMT measurement in longitudinal ultrasound images using morphological approach","author":"F Molinari","year":"2010","unstructured":"Molinari, F., Zeng, G., and Suri, J. S., Carotid wall segmentation and IMT measurement in longitudinal ultrasound images using morphological approach. International Symposium on Biomedical Imaging, Rotterdam, 2010."},{"key":"9507_CR14","unstructured":"E. Kyriacou, M. S. Pattichis, C. I. Christodoulou et al., \"Ultrasound imaging in the analysis of carotid plaque morphology for the assessment of stroke,\" Plaque imaging: pixel to molecular level, J. S. Suri, C. Yuan, D. L. Wilson et al., eds., pp. 241-275, Amsterdam: IOS Press, 2005."},{"issue":"1","key":"9507_CR15","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s11517-006-0140-3","volume":"45","author":"CP Loizou","year":"2007","unstructured":"Loizou, C. P., Pattichis, C. S., Pantziaris, M., et al., Snakes based segmentation of the common carotid artery intima media. Med Biol Eng Comput 45(1):35\u201349, 2007.","journal-title":"Med Biol Eng Comput"},{"key":"9507_CR16","unstructured":"F. Molinari, S. Delsanto, P. Giustetto et al., \"User-independent plaque segmentation and accurate intima-media thickness measurement of carotid artery wall using ultrasound,\" Advances in diagnostic and therapeutic ultrasound imaging, J. S. Suri, C. Kathuria, R. F. Chang et al., eds., pp. 111-140, Norwood, MA: Artech House, 2008."},{"issue":"4","key":"9507_CR17","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1142\/S0219519409003115","volume":"9","author":"F Molinari","year":"2009","unstructured":"Molinari, F., Liboni, W., Giustetto, P., et al., Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners. J Mech Med Biol 9(4):481\u2013505, 2009.","journal-title":"J Mech Med Biol"},{"issue":"1","key":"9507_CR18","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/1049-9660(92)90003-L","volume":"55","author":"DJ Williams","year":"1992","unstructured":"Williams, D. J., and Shah, M., A fast algorithm for active contours and curvature estimation. Cvgip-Image Understanding 55(1):14\u201326, 1992.","journal-title":"Cvgip-Image Understanding"},{"issue":"1","key":"9507_CR19","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1007\/s100440050005","volume":"3","author":"JS Suri","year":"2000","unstructured":"Suri, J. S., Haralick, R. M., and Sheehan, F. H., Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms. Pattern Anal App 3(1):39\u201360, 2000.","journal-title":"Pattern Anal App"},{"issue":"2","key":"9507_CR20","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1162\/089976603762553004","volume":"15","author":"JJ Verbeek","year":"2003","unstructured":"Verbeek, J. J., Vlassis, N., and Krose, B., Efficient greedy learning of gaussian mixture models. Neural Comput 15(2):469\u201385, 2003.","journal-title":"Neural Comput"},{"key":"9507_CR21","doi-asserted-by":"crossref","unstructured":"F. Molinari, G. Zeng, and J. S. Suri, \u201c Greedy technique and its validation for fusion of two segmentation paradigms leading to an accurate IMT measure in plaqued carotid arterial ultrasound\u201d Journal for Vascular Ultrasound 34(2):63\u201373, 2010.","DOI":"10.1177\/154431671003400201"}],"container-title":["Journal of Medical Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-010-9507-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10916-010-9507-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-010-9507-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,6,2]],"date-time":"2019-06-02T08:51:37Z","timestamp":1559465497000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10916-010-9507-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,5,8]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["9507"],"URL":"https:\/\/doi.org\/10.1007\/s10916-010-9507-y","relation":{},"ISSN":["0148-5598","1573-689X"],"issn-type":[{"value":"0148-5598","type":"print"},{"value":"1573-689X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,5,8]]}}}