{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T08:30:11Z","timestamp":1782289811307,"version":"3.54.5"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2019,6,14]],"date-time":"2019-06-14T00:00:00Z","timestamp":1560470400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,14]],"date-time":"2019-06-14T00:00:00Z","timestamp":1560470400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Syst"],"published-print":{"date-parts":[[2019,7]]},"DOI":"10.1007\/s10916-019-1333-2","type":"journal-article","created":{"date-parts":[[2019,6,14]],"date-time":"2019-06-14T01:03:51Z","timestamp":1560474231000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Controlling a Lower-Leg Exoskeleton Using Voltage and Current Variation Signals of a DC Motor Mounted at the Knee Joint"],"prefix":"10.1007","volume":"43","author":[{"given":"Muhammad","family":"Al-Ayyad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bashar Al-haj","family":"Moh\u2019d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3450-9406","authenticated-orcid":false,"given":"Nidal","family":"Qasem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Al-Takrori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,14]]},"reference":[{"key":"1333_CR1","doi-asserted-by":"crossref","unstructured":"Borisoff, J. F., Mattie, J., and Rafer, V., Concept proposal for a detachable exoskeleton-wheelchair to improve mobility and health. In: 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR). IEEE. (pp. 1\u20136), 2013.","DOI":"10.1109\/ICORR.2013.6650396"},{"issue":"2","key":"1333_CR2","first-page":"214","volume":"7","author":"V Sundaram","year":"2016","unstructured":"Sundaram, V., Kumar, S., Faiz, A., and Maheshwari, S., Design of lower-limb exoskeleton for wheelchair patients. International. Int. J. Sci. Eng. Res. 7(2):214\u20132109, 2016.","journal-title":"Int. J. Sci. Eng. Res."},{"issue":"5","key":"1333_CR3","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1080\/00140139.2015.1081988","volume":"59","author":"MP De Looze","year":"2016","unstructured":"De Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., and O\u2019Sullivan, L. W., Exoskeletons for industrial application and their potential effects on physical work load. Ergonomics 59(5):671\u2013681, 2016.","journal-title":"Ergonomics"},{"key":"1333_CR4","doi-asserted-by":"crossref","unstructured":"Cho, Y. K., Kim, K., Ma, S., and Ueda, J. A robotic wearable exoskeleton for construction worker\u2019s safety and health. ASCE Construction Research Congress 2018: Safety and Disaster Management. ASCE. 19\u201328, 2018.","DOI":"10.1061\/9780784481288.003"},{"issue":"11","key":"1333_CR5","doi-asserted-by":"publisher","first-page":"395","DOI":"10.5772\/57238","volume":"10","author":"Y Miao","year":"2013","unstructured":"Miao, Y., Gao, F., and Pan, D., Mechanical design of a hybrid leg exoskeleton to augment load-carrying for walking. Int. J. Adv. Robot. Syst. SAGE 10(11):395\u2013410, 2013.","journal-title":"Int. J. Adv. Robot. Syst."},{"issue":"4","key":"1333_CR6","doi-asserted-by":"publisher","first-page":"103","DOI":"10.24243\/JMEB\/1.4.192","volume":"1","author":"RG Baldovino","year":"2017","unstructured":"Baldovino, R. G., and Jamisola, Jr., R. S., A survey in the different designs and control systems of powered-exoskeleton for lower extremities. Journal of Mechanical Engineering and Biomechanics (JMEB). Rational Publication 1(4):103\u2013115, 2017.","journal-title":"Journal of Mechanical Engineering and Biomechanics (JMEB)"},{"issue":"6","key":"1333_CR7","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1109\/MCS.2018.2866604","volume":"38","author":"O Harib","year":"2018","unstructured":"Harib, O., Hereid, A., Agrawal, A., Gurriet, T., Finet, S., Boeris, G., Duburcq, A., Mungai, M. E., Masselin, M., Ames, A. D., and Sreenath, K., Feedback control of an exoskeleton for paraplegics: Toward robustly stable, hands-free dynamic walking. IEEE Control. Syst. Mag. IEEE 38(6):61\u201387, 2018.","journal-title":"IEEE Control. Syst. Mag."},{"issue":"2","key":"1333_CR8","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1179\/2045772312Y.0000000003","volume":"35","author":"G Zeilig","year":"2012","unstructured":"Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., and Esquenazi, A., Safety and tolerance of the ReWalk\u2122 exoskeleton suit for ambulation by people with complete spinal cord injury: A pilot study. J. Spinal Cord Med. Taylor and Francis 35(2):96\u2013101, 2012.","journal-title":"J. Spinal Cord Med."},{"issue":"6","key":"1333_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/1729881417743554","volume":"14","author":"BS Rupal","year":"2017","unstructured":"Rupal, B. S., Rafique, S., Singla, A., Singla, E., Isaksson, M., and Virk, G. S., Lower-limb exoskeletons: Research trends and regulatory guidelines in medical and non-medical applications. Int. J. Adv. Robot. Syst. SAGE 14(6):1\u201327, 2017.","journal-title":"Int. J. Adv. Robot. Syst."},{"issue":"2","key":"1333_CR10","doi-asserted-by":"publisher","first-page":"e56137","DOI":"10.1371\/journal.pone.0056137","volume":"8","author":"Philippe Malcolm","year":"2013","unstructured":"Malcolm, P., Derave, W., Galle, S., and De Clercq, D., A simple exoskeleton that assists plantarflexion can reduce the metabolic cost of human walking. PLoS One 8(2):e56137 (pp. 1\u20137), 2013.","journal-title":"PLoS ONE"},{"key":"1333_CR11","volume-title":"Meeting the energy needs of future warriors","author":"National Research Council","year":"2004","unstructured":"National Research Council, Meeting the energy needs of future warriors. Washington: National Academies Press, 2004."},{"key":"1333_CR12","volume-title":"The mechanical systems design handbook: Modeling, measurement, and control","author":"Y Hurmuzlu","year":"2016","unstructured":"Hurmuzlu, Y., and Nwokah, O. D., The mechanical systems design handbook: Modeling, measurement, and control. Boca Raton: CRC Press, 2016."},{"key":"1333_CR13","unstructured":"Okada, K., Inaba, M., and Inoue, H., Real-time and precise self collision detection system for humanoid robots. In: Proceedings of the 2005 IEEE International Conference on Robotics and Automation. IEEE. (pp. 1060\u20131065), 2015."},{"issue":"8","key":"1333_CR14","doi-asserted-by":"publisher","first-page":"112","DOI":"10.5772\/60782","volume":"12","author":"JH Kim","year":"2015","unstructured":"Kim, J. H., Shim, M., Ahn, D. H., Son, B. J., Kim, S. Y., Kim, D. Y., Baek, Y. S., and Cho, B. K., Design of a knee exoskeleton using foot pressure and knee torque sensors. Int. J. Adv. Robot. Syst. SAGE 12(8):112\u2013126, 2015.","journal-title":"Int. J. Adv. Robot. Syst."},{"issue":"2","key":"1333_CR15","doi-asserted-by":"publisher","first-page":"021004","DOI":"10.1088\/1741-2552\/aaa8c0","volume":"15","author":"Y He","year":"2018","unstructured":"He, Y., Eguren, D., Azor\u00edn, J. M., Grossman, R. G., Luu, T. P., and Contreras-Vidal, J. L., Brain\u2013machine interfaces for controlling lower-limb powered robotic systems. J. Neural Eng. IOP Pub. 15(2):021004, 2018.","journal-title":"J. Neural Eng."},{"issue":"5","key":"1333_CR16","first-page":"2747","volume":"15","author":"C Wong","year":"2015","unstructured":"Wong, C., Zhang, Z. Q., Lo, B., and Yang, G. Z., Wearable sensing for solid biomechanics: A review. IEEE Sensors J. IEEE 15(5):2747\u20132760, 2015.","journal-title":"IEEE Sensors J."},{"key":"1333_CR17","unstructured":"Seeland, A., Tabie, M., Kim, S. K., Kirchner, F., and Kirchner, E. A., Adaptive multimodal biosignal control for exoskeleton supported stroke rehabilitation. In: 2017 IEEE International Conference on Systems, Man, and Cybernetics (SMC). IEEE. (pp. 2431\u20132436), 2017."},{"issue":"9","key":"1333_CR18","doi-asserted-by":"publisher","first-page":"12431","DOI":"10.3390\/s130912431","volume":"13","author":"R Chowdhury","year":"2013","unstructured":"Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., and Chang, T., Surface electromyography signal processing and classification techniques. Sensors. MDPI 13(9):12431\u201312466, 2013.","journal-title":"Sensors"},{"issue":"11","key":"1333_CR19","doi-asserted-by":"publisher","first-page":"27738","DOI":"10.3390\/s151127738","volume":"15","author":"JY Jung","year":"2015","unstructured":"Jung, J. Y., Heo, W., Yang, H., and Park, H., A neural network-based gait phase classification method using sensors equipped on lower limb exoskeleton robots. Sensors. MDPI 15(11):27738\u201327759, 2015.","journal-title":"Sensors"},{"issue":"1","key":"1333_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4018\/IJRAT.2017010101","volume":"5","author":"TM Schnieders","year":"2017","unstructured":"Schnieders, T. M., and Stone, R. T., Current work in the human-machine interface for ergonomic intervention with exoskeletons. International Journal of Robotics Applications and Technologies (IJRAT). IGI Global 5(1):1\u20139, 2017.","journal-title":"International Journal of Robotics Applications and Technologies (IJRAT)"},{"key":"1333_CR21","volume-title":"LabVIEW: Advanced programming techniques","author":"R Bitter","year":"2006","unstructured":"Bitter, R., Mohiuddin, T., and Nawrocki, M., LabVIEW: Advanced programming techniques. Boca Raton: CRC Press, 2006."},{"key":"1333_CR22","doi-asserted-by":"crossref","unstructured":"Chachati, L., and Hasan, A., Designing and implementing an electronic system to control moving orthosis virtual mechanical system to emulate lower limb. Cogent Engineering. Taylor and Francis. 5(1):1456632 (pp. 1\u201314), 2018.","DOI":"10.1080\/23311916.2018.1456632"},{"issue":"5\/6","key":"1333_CR23","first-page":"314","volume":"51","author":"C Fleischer","year":"2016","unstructured":"Fleischer, C., Wege, A., Kondak, K., and Hommel, G., Application of EMG signals for controlling exoskeleton robots. Biomed. Tech. Walter de Gruyter 51(5\/6):314\u2013319, 2016.","journal-title":"Biomed. Tech."},{"key":"1333_CR24","volume-title":"Principles of electric machines and power electronics","author":"P Sen","year":"2007","unstructured":"Sen, P., Principles of electric machines and power electronics. Hoboken: Wiley, 2007."}],"container-title":["Journal of Medical Systems"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-019-1333-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s10916-019-1333-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-019-1333-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,12]],"date-time":"2020-06-12T23:19:56Z","timestamp":1592003996000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s10916-019-1333-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,14]]},"references-count":24,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2019,7]]}},"alternative-id":["1333"],"URL":"https:\/\/doi.org\/10.1007\/s10916-019-1333-2","relation":{},"ISSN":["0148-5598","1573-689X"],"issn-type":[{"value":"0148-5598","type":"print"},{"value":"1573-689X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,14]]},"assertion":[{"value":"6 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declared no potential conflicts of interest with respect to the research, authorship, and\/or publication of this article.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interests"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"229"}}