{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T21:44:12Z","timestamp":1783028652308,"version":"3.54.6"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T00:00:00Z","timestamp":1667520000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T00:00:00Z","timestamp":1667520000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Schleswig-Holstein - Campus L\u00fcbeck"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Syst"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In the context of the COVID-19 pandemic, wearable sensors are important for early detection of critical illness especially in COVID-19 outpatients. We sought to determine in this pilot study whether a wearable in-ear sensor for continuous body temperature and heart rate monitoring (Cosinuss company, Munich) is sufficiently accurate for body temperature and heart rate monitoring. Comparing with several anesthesiologic standard of care monitoring devices (urinary bladder and zero-heat flux thermometer and ECG), we evaluated the in-ear sensor during non-cardiac surgery (German Clinical Trials Register Reg.-No: DRKS00012848). Limits of Agreement (LoA) based on Bland\u2013Altman analysis were used to study the agreement between the in-ear sensor and the reference methods. The estimated LoA of the Cosinuss One and bladder temperature monitoring were [-0.79, 0.49] \u00b0C (95% confidence intervals [-1.03, -0.65] (lower LoA) and [0.35, 0.73] (upper LoA)), and [-0.78, 0.34] \u00b0C (95% confidence intervals [-1.18, -0.59] (lower LoA) and [0.16, 0.74] (upper LoA)) of the Cosinuss One and zero-heat flux temperature monitoring. 89% and 79% of Cosinuss One temperature monitoring were within\u2009\u00b1\u20090.5\u00a0\u00b0C limit of bladder and zero-heat flux monitoring, respectively. The estimated LoA of Cosinuss One and ECG heart rate monitoring were [-4.81, 4.27] BPM (95% confidence intervals [-5.09, -4.56] (lower LoA) and [4.01, 4.54] (upper LoA)). The proportion of detection differences within\u2009\u00b1\u20092BPM was 84%. Body temperature and heart rate were reliably measured by the wearable in-ear sensor.<\/jats:p>","DOI":"10.1007\/s10916-022-01872-6","type":"journal-article","created":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T04:26:41Z","timestamp":1667536001000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":27,"title":["Evaluation of a Wearable in-Ear Sensor for Temperature and Heart Rate Monitoring: A Pilot Study"],"prefix":"10.1007","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5595-7414","authenticated-orcid":false,"given":"David Benjamin","family":"Ellebrecht","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4980-4582","authenticated-orcid":false,"given":"Damian","family":"Gola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Kaschwich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,11,4]]},"reference":[{"issue":"8","key":"1872_CR1","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1007\/s10916-020-01587-6","volume":"44","author":"J Teo","year":"2020","unstructured":"Teo J (2020) Early Detection of Silent Hypoxia in Covid-19 Pneumonia Using Smartphone Pulse Oximetry. Journal of Medical Systems 44 (8):134. https:\/\/doi.org\/10.1007\/s10916-020-01587-6","journal-title":"Journal of Medical Systems"},{"issue":"3","key":"1872_CR2","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1213\/ANE.0000000000000319","volume":"119","author":"Y Eshraghi","year":"2014","unstructured":"Eshraghi Y, Nasr V, Parra-Sanchez I, Van Duren A, Botham M, Santoscoy T, Sessler DI (2014) An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients. Anesth Analg 119 (3):543-549. https:\/\/doi.org\/10.1213\/ANE.0000000000000319","journal-title":"Anesth Analg"},{"issue":"12","key":"1872_CR3","doi-asserted-by":"publisher","first-page":"16180","DOI":"10.1021\/acsnano.0c08494","volume":"14","author":"H Lukas","year":"2020","unstructured":"Lukas H, Xu C, Yu Y, Gao W (2020) Emerging Telemedicine Tools for Remote COVID-19 Diagnosis, Monitoring, and Management. ACS Nano 14 (12):16180-16193. https:\/\/doi.org\/10.1021\/acsnano.0c08494","journal-title":"ACS Nano"},{"key":"1872_CR4","doi-asserted-by":"publisher","unstructured":"Channa A, Popescu N, Skibinska J, Burget R (2021) The Rise of Wearable Devices during the COVID-19 Pandemic: A Systematic Review. Sensors (Basel) 21 (17). https:\/\/doi.org\/10.3390\/s21175787","DOI":"10.3390\/s21175787"},{"key":"1872_CR5","doi-asserted-by":"publisher","unstructured":"Jacobsen M, Dembek TA, Kobbe G, Gaidzik PW, Heinemann L (2020) Noninvasive Continuous Monitoring of Vital Signs With Wearables: Fit for Medical Use? J Diabetes Sci Technol:1932296820904947. https:\/\/doi.org\/10.1177\/1932296820904947","DOI":"10.1177\/1932296820904947"},{"key":"1872_CR6","doi-asserted-by":"publisher","unstructured":"Tanwar G, Chauhan R, Singh M, Singh D (2020) Pre-Emption of Affliction Severity Using HRV Measurements from a Smart Wearable; Case-Study on SARS-Cov-2 Symptoms. Sensors (Basel) 20 (24). https:\/\/doi.org\/10.3390\/s20247068","DOI":"10.3390\/s20247068"},{"issue":"2","key":"1872_CR7","doi-asserted-by":"publisher","first-page":"e85","DOI":"10.1016\/S2589-7500(19)30222-5","volume":"2","author":"JM Radin","year":"2020","unstructured":"Radin JM, Wineinger NE, Topol EJ, Steinhubl SR (2020) Harnessing wearable device data to improve state-level real-time surveillance of influenza-like illness in the USA: a population-based study. Lancet Digit Health 2 (2):e85-e93. https:\/\/doi.org\/10.1016\/S2589-7500(19)30222-5","journal-title":"Lancet Digit Health"},{"key":"1872_CR8","doi-asserted-by":"publisher","first-page":"6152041","DOI":"10.1155\/2020\/6152041","volume":"2020","author":"G Zhu","year":"2020","unstructured":"Zhu G, Li J, Meng Z, Yu Y, Li Y, Tang X, Dong Y, Sun G, Zhou R, Wang H, Wang K, Huang W (2020) Learning from Large-Scale Wearable Device Data for Predicting the Epidemic Trend of COVID-19. Discrete Dynamics in Nature and Society 2020:6152041.","journal-title":"Discrete Dynamics in Nature and Society"},{"issue":"2","key":"1872_CR9","doi-asserted-by":"publisher","DOI":"10.1111\/eci.13428","volume":"51","author":"M Malaty","year":"2021","unstructured":"Malaty M, Kayes T, Amarasekera AT, Kodsi M, MacIntyre CR, Tan TC (2021) Incidence and treatment of arrhythmias secondary to coronavirus infection in humans: A systematic review. European journal of clinical investigation 51 (2):e13428. https:\/\/doi.org\/10.1111\/eci.13428","journal-title":"European journal of clinical investigation"},{"key":"1872_CR10","doi-asserted-by":"publisher","unstructured":"Passler S, M\u00fcller N, Senner V (2019) In-Ear Pulse Rate Measurement: A Valid Alternative to Heart Rate Derived from Electrocardiography? Sensors (Basel) 19 (17). https:\/\/doi.org\/10.3390\/s19173641","DOI":"10.3390\/s19173641"},{"issue":"1","key":"1872_CR11","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/ALN.0000000000003481","volume":"134","author":"DI Sessler","year":"2021","unstructured":"Sessler DI (2021) Perioperative Temperature Monitoring. Anesthesiology 134 (1):111-118.","journal-title":"Anesthesiology"},{"issue":"1","key":"1872_CR12","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1097\/ALN.0b013e3181a864ca","volume":"111","author":"GE Langham","year":"2009","unstructured":"Langham GE, Maheshwari A, Contrera K, You J, Mascha E, Sessler DI (2009) Noninvasive temperature monitoring in postanesthesia care units. Anesthesiology 111 (1):90-96. https:\/\/doi.org\/10.1097\/ALN.0b013e3181a864ca","journal-title":"Anesthesiology"},{"key":"1872_CR13","unstructured":"National Collaborating Centre for Nursing and Supportive Care (publisher)(2008. 29; Addendum 65.1 Dec. 2016. https:\/\/www.nice.org.uk\/) Hypothermia: prevention and management in adults having surgery, NICE Clinical Guideline 65."},{"issue":"10","key":"1872_CR14","doi-asserted-by":"publisher","first-page":"166","DOI":"10.3238\/arztebl.2015.0166","volume":"112","author":"A Torossian","year":"2015","unstructured":"Torossian A, Brauer A, Hocker J, Bein B, Wulf H, Horn EP (2015) Preventing inadvertent perioperative hypothermia. Dtsch Arztebl Int 112 (10):166-172. https:\/\/doi.org\/10.3238\/arztebl.2015.0166","journal-title":"Dtsch Arztebl Int"},{"key":"1872_CR15","unstructured":"R-Core-Team (2018) R: A language and environment for statistical computing. R Foundation for Statistical Computing (Publisher)"},{"issue":"1","key":"1872_CR16","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1007\/s10877-018-0143-2","volume":"33","author":"JA Sastre","year":"2019","unstructured":"Sastre JA, Pascual MJ, Lopez T (2019) Evaluation of the novel non-invasive zero-heat-flux Tcore thermometer in cardiac surgical patients. J Clin Monit Comput 33 (1):165-172. https:\/\/doi.org\/10.1007\/s10877-018-0143-2","journal-title":"J Clin Monit Comput"},{"issue":"4","key":"1872_CR17","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1097\/00000539-200010000-00039","volume":"91","author":"M Winkler","year":"2000","unstructured":"Winkler M, Akca O, Birkenberg B, Hetz H, Scheck T, Arkilic CF, Kabon B, Marker E, Grubl A, Czepan R, Greher M, Goll V, Gottsauner-Wolf F, Kurz A, Sessler DI (2000) Aggressive warming reduces blood loss during hip arthroplasty. Anesth Analg 91 (4):978-984","journal-title":"Anesth Analg"},{"key":"1872_CR18","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1080\/10543400701329422","volume":"17","author":"JM Bland","year":"2007","unstructured":"Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571-582","journal-title":"J Biopharm Stat"},{"issue":"1","key":"1872_CR19","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/s10877-014-9577-3","volume":"29","author":"E Olofsen","year":"2015","unstructured":"Olofsen E, Dahan A, Borsboom G, Drummond G (2015) Improvements in the application and reporting of advanced Bland\u2013Altman methods of comparison. Journal of Clinical Monitoring and Computing 29 (1):127-139. https:\/\/doi.org\/10.1007\/s10877-014-9577-3","journal-title":"Journal of Clinical Monitoring and Computing"},{"issue":"3","key":"1872_CR20","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1214\/aos\/1176344202","volume":"6","author":"JD Thomas","year":"1978","unstructured":"Thomas JD, Hultquist RA (1978) Interval Estimation for the Unbalanced Case of the One-Way Random Effects Model. The Annals of Statistics 6 (3):582-587.","journal-title":"The Annals of Statistics"},{"issue":"4","key":"1872_CR21","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1177\/0962280210383082","volume":"21","author":"A Donner","year":"2012","unstructured":"Donner A, Zou G (2012) Closed-form confidence intervals for functions of the normal mean and standard deviation. Statistical Methods in Medical Research 21 (4):347-359. https:\/\/doi.org\/10.1177\/0962280210383082","journal-title":"Statistical Methods in Medical Research"},{"issue":"6","key":"1872_CR22","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1177\/0962280211402548","volume":"22","author":"G Zou","year":"2013","unstructured":"Zou G (2013) Confidence interval estimation for the Bland\u2013Altman limits of agreement with multiple observations per individual. Statistical Methods in Medical Research 22 (6):630-642. https:\/\/doi.org\/10.1177\/0962280211402548","journal-title":"Statistical Methods in Medical Research"},{"key":"1872_CR23","doi-asserted-by":"publisher","DOI":"10.1002\/9781118553282","volume-title":"Measurement Agreement","author":"PK Choudhary","year":"2017","unstructured":"Choudhary PK, Nagaraja HN (2017) Measurement Agreement. Wiley & Sons, Inc., Hoboken, USA."},{"issue":"10038","key":"1872_CR24","doi-asserted-by":"publisher","first-page":"2655","DOI":"10.1016\/S0140-6736(15)00981-2","volume":"387","author":"DI Sessler","year":"2016","unstructured":"Sessler DI (2016) Perioperative thermoregulation and heat balance. Lancet 387 (10038):2655-2664. https:\/\/doi.org\/10.1016\/S0140-6736(15)00981-2","journal-title":"Lancet"},{"issue":"1","key":"1872_CR25","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.arr.2009.07.003","volume":"9","author":"D Weinert","year":"2010","unstructured":"Weinert D (2010) Circadian temperature variation and ageing. Ageing Res Rev 9 (1):51-60. https:\/\/doi.org\/10.1016\/j.arr.2009.07.003","journal-title":"Ageing Res Rev"},{"key":"1872_CR26","doi-asserted-by":"crossref","unstructured":"Fallis WM (2002) Monitoring bladder temperatures in the OR. AORN J 76 (3):467-476, 481-466, 488-469","DOI":"10.1016\/S0001-2092(06)61661-X"},{"issue":"6","key":"1872_CR27","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1007\/BF03011406","volume":"32","author":"JG Ramsay","year":"1985","unstructured":"Ramsay JG, Ralley FE, Whalley DG, DelliColli P, Wynands JE (1985) Site of temperature monitoring and prediction of afterdrop after open heart surgery. Can Anaesth Soc J 32 (6):607-612","journal-title":"Can Anaesth Soc J"},{"issue":"1","key":"1872_CR28","doi-asserted-by":"publisher","first-page":"43","DOI":"10.4037\/ajcc2018865","volume":"27","author":"HM Schell-Chaple","year":"2018","unstructured":"Schell-Chaple HM, Liu KD, Matthay MA, Puntillo KA (2018) Rectal and Bladder Temperatures vs Forehead Core Temperatures Measured With SpotOn Monitoring System. Am J Crit Care 27 (1):43-50. https:\/\/doi.org\/10.4037\/ajcc2018865","journal-title":"Am J Crit Care"},{"issue":"11","key":"1872_CR29","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1097\/EJA.0000000000000822","volume":"35","author":"M Boisson","year":"2018","unstructured":"Boisson M, Alaux A, Kerforne T, Mimoz O, Debaene B, Dahyot-Fizelier C, Frasca D (2018) Intra-operative cutaneous temperature monitoring with zero-heat-flux technique (3M SpotOn) in comparison with oesophageal and arterial temperature: A prospective observational study. Eur J Anaesthesiol 35 (11):825-830. https:\/\/doi.org\/10.1097\/EJA.0000000000000822","journal-title":"Eur J Anaesthesiol"},{"issue":"7","key":"1872_CR30","doi-asserted-by":"publisher","first-page":"e715","DOI":"10.1097\/CCM.0000000000002317","volume":"45","author":"C Dahyot-Fizelier","year":"2017","unstructured":"Dahyot-Fizelier C, Lamarche S, Kerforne T, Benard T, Giraud B, Bellier R, Carise E, Frasca D, Mimoz O (2017) Accuracy of Zero-Heat-Flux Cutaneous Temperature in Intensive Care Adults. Crit Care Med 45 (7):e715-e717. https:\/\/doi.org\/10.1097\/CCM.0000000000002317","journal-title":"Crit Care Med"},{"issue":"4","key":"1872_CR31","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1111\/j.1365-2044.1996.tb07743.x","volume":"51","author":"SH Russell","year":"1996","unstructured":"Russell SH, Freeman JW (1996) Comparison of bladder, oesophageal and pulmonary artery temperatures in major abdominal surgery. Anaesthesia 51 (4):338-340","journal-title":"Anaesthesia"},{"issue":"6","key":"1872_CR32","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1109\/TBME.2017.2720463","volume":"65","author":"A Martin","year":"2018","unstructured":"Martin A, Voix J (2018) In-Ear Audio Wearable: Measurement of Heart and Breathing Rates for Health and Safety Monitoring. IEEE Trans Biomed Eng 65 (6):1256-1263. https:\/\/doi.org\/10.1109\/TBME.2017.2720463","journal-title":"IEEE Trans Biomed Eng"},{"key":"1872_CR33","doi-asserted-by":"publisher","first-page":"5030","DOI":"10.1109\/EMBC.2012.6347123","volume":"2012","author":"DD He","year":"2012","unstructured":"He DD, Winokur ES, Sodini CG (2012) An ear-worn continuous ballistocardiogram (BCG) sensor for cardiovascular monitoring. Conference proceedings : Annual International Conference of the IEEE Engineering in Medicine and Biology Society IEEE Engineering in Medicine and Biology Society Annual Conference 2012:5030-5033. https:\/\/doi.org\/10.1109\/EMBC.2012.6347123","journal-title":"Conference proceedings : Annual International Conference of the IEEE Engineering in Medicine and Biology Society IEEE Engineering in Medicine and Biology Society Annual Conference"},{"issue":"1","key":"1872_CR34","doi-asserted-by":"publisher","DOI":"10.2196\/14857","volume":"4","author":"T Inui","year":"2020","unstructured":"Inui T, Kohno H, Kawasaki Y, Matsuura K, Ueda H, Tamura Y, Watanabe M, Inage Y, Yakita Y, Wakabayashi Y, Matsumiya G (2020) Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study. JMIR Cardio 4 (1):e14857. https:\/\/doi.org\/10.2196\/14857","journal-title":"JMIR Cardio"},{"issue":"2","key":"1872_CR35","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1097\/CRD.0000000000000243","volume":"27","author":"CL Karmen","year":"2019","unstructured":"Karmen CL, Reisfeld MA, McIntyre MK, Timmermans R, Frishman W (2019) The Clinical Value of Heart Rate Monitoring Using an Apple Watch. Cardiol Rev 27 (2):60-62. https:\/\/doi.org\/10.1097\/CRD.0000000000000243","journal-title":"Cardiol Rev"},{"issue":"2","key":"1872_CR36","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2017-020162","volume":"8","author":"MJMM Breteler","year":"2018","unstructured":"Breteler MJMM, Huizinga E, van Loon K, Leenen LPH, Dohmen DAJ, Kalkman CJ, Blokhuis TJ (2018) Reliability of wireless monitoring using a wearable patch sensor in high-risk surgical patients at a step-down unit in the Netherlands: a clinical validation study. BMJ Open 8 (2):e020162. https:\/\/doi.org\/10.1136\/bmjopen-2017-020162","journal-title":"BMJ Open"},{"issue":"6","key":"1872_CR37","doi-asserted-by":"publisher","first-page":"1688","DOI":"10.1213\/01.ane.0000289639.87836.79","volume":"105","author":"T Kiya","year":"2007","unstructured":"Kiya T, Yamakage M, Hayase T, Satoh J, Namiki A (2007) The usefulness of an earphone-type infrared tympanic thermometer for intraoperative core temperature monitoring. Anesth Analg 105 (6):1688-1692. https:\/\/doi.org\/10.1213\/01.ane.0000289639.87836.79","journal-title":"Anesth Analg"},{"issue":"9","key":"1872_CR38","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1097\/00003246-199609000-00012","volume":"24","author":"LC Rotello","year":"1996","unstructured":"Rotello LC, Crawford L, Terndrup TE (1996) Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures. Crit Care Med 24 (9):1501-1506","journal-title":"Crit Care Med"},{"key":"1872_CR39","doi-asserted-by":"publisher","unstructured":"Klum M, Urban M, Tigges T, Pielmus AG, Feldheiser A, Schmitt T, Orglmeister R (2020) Wearable Cardiorespiratory Monitoring Employing a Multimodal Digital Patch Stethoscope: Estimation of ECG, PEP, LVETand Respiration Using a 55 mm Single-Lead ECG and Phonocardiogram. Sensors (Basel) 20 (7). https:\/\/doi.org\/10.3390\/s20072033","DOI":"10.3390\/s20072033"},{"key":"1872_CR40","unstructured":"Cosinuss GmbH MG (2022) Telecovid \u2013 Remote Patient Monitoring for COVID-19. https:\/\/www.cosinuss.com\/en\/portfolio-items\/study-on-remote-patient-monitoring-for-covid-19. Accessed 09\/20 2022"}],"container-title":["Journal of Medical Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-022-01872-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10916-022-01872-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-022-01872-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,31]],"date-time":"2022-12-31T04:33:06Z","timestamp":1672461186000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10916-022-01872-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,4]]},"references-count":40,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1872"],"URL":"https:\/\/doi.org\/10.1007\/s10916-022-01872-6","relation":{},"ISSN":["1573-689X"],"issn-type":[{"value":"1573-689X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,4]]},"assertion":[{"value":"10 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures conducted in our study involving human participants were in accordance with the ethical standards of the institutional review board and with the Helsinki declaration and its amendments. Written informed consent was obtained from all patients. Ethical approval for this study was provided by the University of Luebeck Ethics committee (Reg.-Nr.: 16\u2013324).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"The authors have no known conflicts of interest associated with this study and there has been no significant financial support for this work that could have influenced its outcome.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}],"article-number":"91"}}