{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T11:19:04Z","timestamp":1793445544676,"version":"4.5.0"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T00:00:00Z","timestamp":1679616000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T00:00:00Z","timestamp":1679616000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum D\u00fcsseldorf. Anstalt \u00f6ffentlichen Rechts"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Syst"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Analysis of chemical exchange saturation transfer (CEST) MRI data requires sophisticated methods to obtain reliable results about metabolites in the tissue under study. CEST generates z-spectra with multiple components, each originating from individual molecular groups. The individual lines with Lorentzian line shape are mostly overlapping and disturbed by various effects. We present an elaborate method based on an adaptive nonlinear least squares algorithm that provides robust quantification of z-spectra and incorporates prior knowledge in the fitting process. To disseminate CEST to the research community, we developed software as part of this study that runs on the Microsoft Windows operating system and will be made freely available to the community. Special attention has been paid to establish a low entrance threshold and high usability, so that even less experienced users can successfully analyze CEST data.<\/jats:p>","DOI":"10.1007\/s10916-023-01931-6","type":"journal-article","created":{"date-parts":[[2023,3,24]],"date-time":"2023-03-24T10:03:04Z","timestamp":1679652184000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["calf \u2013 Software for CEST Analysis with Lorentzian Fitting"],"prefix":"10.1007","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5830-423X","authenticated-orcid":false,"given":"Hans-J\u00f6rg","family":"Wittsack","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl Ludger","family":"Radke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Stabinska","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexandra","family":"Ljimani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anja","family":"M\u00fcller-Lutz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,24]]},"reference":[{"key":"1931_CR1","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1146\/annurev.bioeng.9.060906.151929","volume":"10","author":"AD Sherry","year":"2008","unstructured":"Sherry, A. D. & Woods, M. (2008) Chemical exchange saturation transfer contrast agents for magnetic resonance imaging. Annual review of biomedical engineering 10:391\u2013411","journal-title":"Annual review of biomedical engineering"},{"key":"1931_CR2","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1002\/mrm.22761","volume":"65","author":"PC van Zijl","year":"2011","unstructured":"van Zijl, P. C. & Yadav, N. N. (2011) Chemical exchange saturation transfer (CEST): what is in a name and what isn\u2019t? Magnetic resonance in medicine 65:927\u2013948","journal-title":"Magnetic resonance in medicine"},{"key":"1931_CR3","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1006\/jmre.1999.1956","volume":"143","author":"KM Ward","year":"2000","unstructured":"Ward, K. M., Aletras, A. H. & Balaban, R. S. (2000) A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). Journal of magnetic resonance 143:79\u201387","journal-title":"Journal of magnetic resonance"},{"issue":"1","key":"1931_CR4","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1002\/jmri.25838","volume":"47","author":"KM Jones","year":"2018","unstructured":"Jones KM, Pollard AC, Pagel MD. (2018) Clinical applications of chemical exchange saturation transfer (CEST) MRI. J Magn Reson Imaging 47(1):11-27","journal-title":"J Magn Reson Imaging"},{"key":"1931_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/nbm.3216","volume":"28","author":"K Cai","year":"2015","unstructured":"Cai, K. et al. (2015) CEST signal at 2 ppm (CEST@2 ppm) from Z-spectral fitting correlates with creatine distribution in brain tumor. NMR in biomedicine 28:1\u20138","journal-title":"NMR in biomedicine"},{"key":"1931_CR6","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1038\/nm.3252","volume":"19","author":"S Walker-Samuel","year":"2013","unstructured":"Walker-Samuel, S. et al. (2013) In vivo imaging of glucose uptake and metabolism in tumors. Nature medicine 19:1067\u20131072","journal-title":"Nature medicine"},{"key":"1931_CR7","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1038\/sj.jcbfm.9600424","volume":"27","author":"PZ Sun","year":"2007","unstructured":"Sun, P. Z., Zhou, J., Sun, W., Huang, J. & van Zijl, P. C. (2007) Detection of the ischemic penumbra using pH-weighted MRI. Journal of cerebral blood flow and metabolism: official journal of the International Society of Cerebral Blood Flow and Metabolism 27:1129\u20131136","journal-title":"Journal of cerebral blood flow and metabolism: official journal of the International Society of Cerebral Blood Flow and Metabolism"},{"key":"1931_CR8","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1002\/jmri.22480","volume":"33","author":"G Jia","year":"2011","unstructured":"Jia, G. et al. (2011) Amide proton transfer MR imaging of prostate cancer: A preliminary study. J Magn Reson Imaging 33:647\u2013654","journal-title":"J Magn Reson Imaging"},{"key":"1931_CR9","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1002\/mrm.25053","volume":"72","author":"LQ Chen","year":"2014","unstructured":"Chen, L. Q. et al. (2014) Evaluations of extracellular pH within in vivo tumors using acidoCEST MRI. Magnetic resonance in medicine 72:1408\u20131417","journal-title":"Magnetic resonance in medicine"},{"key":"1931_CR10","doi-asserted-by":"publisher","first-page":"4542","DOI":"10.1073\/pnas.1323855111","volume":"111","author":"K Sagiyama","year":"2014","unstructured":"Sagiyama, K. et al. (2014) In vivo chemical exchange saturation transfer imaging allows early detection of a therapeutic response in glioblastoma. Proc Natl Acad Sci USA 111:4542\u20134547","journal-title":"Proc Natl Acad Sci USA"},{"key":"1931_CR11","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/j.jmr.2011.05.001","volume":"211","author":"M Zaiss","year":"2011","unstructured":"Zaiss, M., Schmitt, B. & Bachert, P. (2011) Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectra. Journal of magnetic resonance 211:149\u2013155","journal-title":"Journal of magnetic resonance"},{"issue":"1","key":"1931_CR12","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1038\/s41598-017-00167-y","volume":"7","author":"IY Zhou","year":"2017","unstructured":"Zhou IY, Wang E, Cheung JS, Zhang X, Fulci G, Sun PZ. (2017) Quantitative chemical exchange saturation transfer (CEST) MRI of glioma using Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting. Sci Rep. 7(1):84","journal-title":"Sci Rep."},{"issue":"11","key":"1931_CR13","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4133","volume":"32","author":"J Breitling","year":"2019","unstructured":"Breitling J, Deshmane A, Goerke S, Korzowski A, Herz K, Ladd ME, Scheffler K, Bachert P, Zaiss M. (2019) Adaptive denoising for chemical exchange saturation transfer MR imaging. NMR Biomed. 32(11):e4133","journal-title":"NMR Biomed."},{"issue":"6","key":"1931_CR14","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1002\/mrm.21873","volume":"61","author":"M Kim","year":"2009","unstructured":"Kim M, Gillen J, Landman BA, Zhou J, van Zijl PC. (2009) Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments. Magn Reson Med. 61(6):1441-1450","journal-title":"Magn Reson Med."},{"issue":"5","key":"1931_CR15","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1007\/s10334-018-0689-5","volume":"31","author":"A M\u00fcller-Lutz","year":"2018","unstructured":"M\u00fcller-Lutz A, Ljimani A, Stabinska J, Zaiss M, Boos J, Wittsack HJ, Schleich C. (2018) Comparison of B0 versus B0 and B1 field inhomogeneity correction for glycosaminoglycan chemical exchange saturation transfer imaging. MAGMA 31(5):645-651","journal-title":"MAGMA"},{"issue":"1","key":"1931_CR16","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.mri.2013.07.009","volume":"32","author":"W Wei","year":"2014","unstructured":"Wei W, Jia G, Flanigan D, Zhou J, Knopp MV. (2014) Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method. Magn Reson Imaging 32(1):41-7","journal-title":"Magn Reson Imaging"},{"issue":"3","key":"1931_CR17","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1007\/s10334-016-0544-5","volume":"29","author":"MM Schreiner","year":"2016","unstructured":"Schreiner MM, Zb\u00fd\u0148 \u0160, Schmitt B, Weber M, Domayer S, Windhager R, Trattnig S, Mlyn\u00e1rik V. (2016) Reproducibility and regional variations of an improved gagCEST protocol for the in vivo evaluation of knee cartilage at 7\u00a0T. MAGMA 29(3):513-21","journal-title":"MAGMA"},{"key":"1931_CR18","doi-asserted-by":"crossref","unstructured":"Heo HY, Zhang Y, Lee DH, Hong X, Zhou J. (2016) Quantitative assessment of amide proton transfer (APT) and nuclear overhauser enhancement (NOE) imaging with extrapolated semi-solid magnetization transfer reference (EMR) signals: Application to a rat glioma model at 4.7 Tesla. Magn Reson Med 75(1):137\u201349","DOI":"10.1002\/mrm.25581"},{"issue":"2","key":"1931_CR19","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1002\/mrm.26459","volume":"78","author":"N Geades","year":"2017","unstructured":"Geades N, Hunt BAE, Shah SM, Peters A, Mougin OE, Gowland PA. (2017) Quantitative analysis of the z-spectrum using a numerically simulated look-up table: Application to the healthy human brain at 7T. Magn Reson Med 78(2):645-655","journal-title":"Magn Reson Med"},{"key":"1931_CR20","doi-asserted-by":"crossref","unstructured":"Zhang XY, Wang F, Afzal A, Xu J, Gore JC, Gochberg DF, Zu Z. (2016) A new NOE-mediated MT signal at around -1.6ppm for detecting ischemic stroke in rat brain. Magn Reson Imaging 34(8):1100\u20131106","DOI":"10.1016\/j.mri.2016.05.002"},{"issue":"4","key":"1931_CR21","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s11307-017-1154-y","volume":"20","author":"J Zhang","year":"2018","unstructured":"Zhang J, Zhu W, Tain R, Zhou XJ, Cai K. (2018) Improved Differentiation of Low-Grade and High-Grade Gliomas and Detection of Tumor Proliferation Using APT Contrast Fitted from Z-Spectrum. Mol Imaging Biol 20(4):623-631","journal-title":"Mol Imaging Biol"},{"key":"1931_CR22","doi-asserted-by":"crossref","unstructured":"Krikken E, Khlebnikov V, Zaiss M, Jibodh RA, van Diest PJ, Luijten PR, Klomp DWJ, van Laarhoven HWM, Wijnen JP. (2018) Amide chemical exchange saturation transfer at 7 T: a possible biomarker for detecting early response to neoadjuvant chemotherapy in breast cancer patients. Breast Cancer Res. Jun 14;20(1):51","DOI":"10.1186\/s13058-018-0982-2"},{"key":"1931_CR23","doi-asserted-by":"crossref","unstructured":"van der Veen JW, de Beer R, Luyten PR, van Ormondt D. (1988) Accurate quantification of in vivo 31P NMR signals using the variable projection method and prior knowledge. Magn Reson Med Jan;6(1):92\u201398","DOI":"10.1002\/mrm.1910060111"},{"key":"1931_CR24","doi-asserted-by":"crossref","unstructured":"Vanhamme L, van den Boogaart A, Van Huffel S. (1997) Improved method for accurate and efficient quantification of MRS data with use of prior knowledge. J Magn Reson Nov;129(1):35\u201343","DOI":"10.1006\/jmre.1997.1244"},{"issue":"3","key":"1931_CR25","first-page":"367","volume":"7","author":"John Dennis","year":"1981","unstructured":"John Dennis, David Gay, Roy Welsch, (1981) Algorithm 573: An Adaptive Nonlinear Least-Squares Algorithm, ACM Transactions on Mathematical Software 7(3):367-383","journal-title":"ACM Transactions on Mathematical Software"},{"key":"1931_CR26","volume-title":"Numerical Methods for Unconstrained Optimisation and Nonlinear Equations","author":"JE Dennis","year":"1983","unstructured":"J. E. Dennis and R. B. Schnabel (1983) Numerical Methods for Unconstrained Optimisation and Nonlinear Equations. Prentice\u2013Hall, Englewood Cliffs, NJ"},{"issue":"2","key":"1931_CR27","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/S0377-0427(97)00039-3","volume":"81","author":"JC Butcher","year":"1997","unstructured":"Butcher JC, Jackiewicz Z, Mittelmann HD. A nonlinear optimization approach to the construction of general linear methods of high order. Journal of Computional and Applied Mathematics, 81(2) 1997: 181-196","journal-title":"Journal of Computional and Applied Mathematics"},{"key":"1931_CR28","unstructured":"https:\/\/www.netlib.org\/ (01\/26\/2023)"},{"key":"1931_CR29","volume-title":"Practical Optimization","author":"PE Gill","year":"1988","unstructured":"Gill PE, Murray W, Wright MH (1988) Practical Optimization. Academic Press, San Diego"},{"key":"1931_CR30","first-page":"60","volume":"2","author":"A Buades","year":"2005","unstructured":"Buades A (2005) A non-local algorithm for image denoising. Computer Vision and Pattern Recognition 2:60\u201365","journal-title":"Computer Vision and Pattern Recognition"},{"key":"1931_CR31","unstructured":"https:\/\/opencv.org\/ (01\/26\/2023)"},{"issue":"6","key":"1931_CR32","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1002\/mrm.21873","volume":"61","author":"M Kim","year":"2009","unstructured":"Kim M, Gillen J, Landman BA, Zhou J, van Zijl PC. (2009) Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments. Magn Reson Med 61(6):1441-1450","journal-title":"Magn Reson Med"},{"key":"1931_CR33","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1109\/5.993400","volume":"90","author":"EA Meijering","year":"2002","unstructured":"Meijering, E. A (2002) Chronology of Interpolation: From Ancient Astronomy to Modern Signal and Image Processing. Proc. IEEE 90:319\u2013342","journal-title":"Proc. IEEE"},{"issue":"3","key":"1931_CR34","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1016\/j.mri.2015.10.024","volume":"34","author":"A M\u00fcller-Lutz","year":"2016","unstructured":"M\u00fcller-Lutz A, Schleich C, Schmitt B, Antoch G, Matuschke F, Quentin M, Wittsack HJ, Miese F. (2016) Gender, BMI and T2 dependencies of glycosaminoglycan chemical exchange saturation transfer in intervertebral discs. Magn Reson Imaging 34(3):271-275","journal-title":"Magn Reson Imaging"},{"issue":"2","key":"1931_CR35","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1002\/mrm.24474","volume":"70","author":"MA Chappell","year":"2013","unstructured":"Chappell MA, Donahue MJ, Tee YK, Khrapitchev AA, Sibson NR, Jezzard P, Payne SJ. Quantitative Bayesian model-based analysis of amide proton transfer MRI. Magn Reson Med. 2013 Aug;70(2):556-67.","journal-title":"Magn Reson Med."},{"key":"1931_CR36","unstructured":"Croal PL, Msayib Y, Ray KJ, Craig M, Chappell M. QuantiCEST: Bayesian Model-based Analysis of CEST MRI. June 2018 Conference: ESMRMB-ISMRM Joint Annual Meeting 2018, Paris, France"},{"issue":"3","key":"1931_CR37","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1002\/nbm.3054","volume":"27","author":"M Zaiss","year":"2014","unstructured":"Zaiss M, Xu J, Goerke S, Khan IS, Singer RJ, Gore JC, Gochberg DF, Bachert P. Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke. NMR Biomed. 2014 Mar;27(3):240-52.","journal-title":"NMR Biomed."},{"issue":"5","key":"1931_CR38","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1002\/nbm.3283","volume":"28","author":"J Windschuh","year":"2015","unstructured":"Windschuh J, Zaiss M, Meissner JE, Paech D, Radbruch A, Ladd ME, Bachert P. Correction of B1-inhomogeneities for relaxation-compensated CEST imaging at 7\u2009T. NMR Biomed. 2015 May;28(5):529-37.","journal-title":"NMR Biomed."},{"issue":"1","key":"1931_CR39","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1109\/TSP.2008.2005752","volume":"57","author":"M Chappell","year":"2009","unstructured":"Chappell, M., Groves, A., Whitcher, B., & Woolrich, M. (2009). Variational Bayesian Inference for a Nonlinear Forward Model. IEEE Transactions on Signal Processing, 57(1), 223\u2013236.","journal-title":"IEEE Transactions on Signal Processing"},{"issue":"1","key":"1931_CR40","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/s12859-018-2588-1","volume":"20","author":"C Debus","year":"2019","unstructured":"Debus C, Floca R, Ingrisch M, Kompan I, Maier-Hein K, Abdollahi A, Nolden M. MITK-ModelFit: A generic open-source framework for model fits and their exploration in medical imaging - design, implementation and application on the example of DCE-MRI. BMC Bioinformatics. 2019 Jan 16;20(1):31.","journal-title":"BMC Bioinformatics."},{"issue":"2","key":"1931_CR41","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1002\/mrm.26133","volume":"77","author":"P Schuenke","year":"2017","unstructured":"Schuenke P, Windschuh J, Roeloffs V, Ladd ME, Bachert P, Zaiss M. Simultaneous mapping of water shift and B1 (WASABI)-Application to field-Inhomogeneity correction of CEST MRI data. Magn Reson Med. 2017 Feb;77(2):571-580.","journal-title":"Magn Reson Med."},{"issue":"1","key":"1931_CR42","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1002\/mrm.29448","volume":"89","author":"O Cohen","year":"2023","unstructured":"Cohen O, Yu VY, Tringale KR, Young RJ, Perlman O, Farrar CT, Otazo R. CEST MR fingerprinting (CEST-MRF) for brain tumor quantification using EPI readout and deep learning reconstruction. Magn Reson Med. 2023 Jan;89(1):233-249.","journal-title":"Magn Reson Med."},{"issue":"6","key":"1931_CR43","doi-asserted-by":"publisher","first-page":"2792","DOI":"10.1002\/mrm.29173","volume":"87","author":"O Perlman","year":"2022","unstructured":"Perlman O, Zhu B, Zaiss M, Rosen MS, Farrar CT. An end-to-end AI-based framework for automated discovery of rapid CEST\/MT MRI acquisition protocols and molecular parameter quantification (AutoCEST). Magn Reson Med. 2022 Jun;87(6):2792-2810.","journal-title":"Magn Reson Med."},{"issue":"11","key":"1931_CR44","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4133","volume":"32","author":"J Breitling","year":"2019","unstructured":"Breitling J, Deshmane A, Goerke S, Korzowski A, Herz K, Ladd ME, Scheffler K, Bachert P, Zaiss M. (2019 ) Adaptive denoising for chemical exchange saturation transfer MR imaging. NMR Biomed 32(11):e4133","journal-title":"NMR Biomed"},{"issue":"6","key":"1931_CR45","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.1002\/jmri.24945","volume":"42","author":"A M\u00fcller-Lutz","year":"2015","unstructured":"M\u00fcller-Lutz A, Schleich C, Pentang G, Schmitt B, Lanzman RS, Matuschke F, Wittsack HJ, Miese F. (2015) Age-dependency of glycosaminoglycan content in lumbar discs: A 3t gagcEST study. J Magn Reson Imaging 42(6):1517-1523","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"1931_CR46","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1002\/mrm.28117","volume":"84","author":"F Glang","year":"2020","unstructured":"Glang F, Deshmane A, Prokudin S, Martin F, Herz K, Lindig T, Bender B, Scheffler K, Zaiss M. (2020) DeepCEST 3T: Robust MRI parameter determination and uncertainty quantification with neural networks-application to CEST imaging of the human brain at 3T. Magn Reson Med 84(1):450-466","journal-title":"Magn Reson Med"}],"container-title":["Journal of Medical Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-023-01931-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10916-023-01931-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-023-01931-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,29]],"date-time":"2023-12-29T17:05:33Z","timestamp":1703869533000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10916-023-01931-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,24]]},"references-count":46,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1931"],"URL":"https:\/\/doi.org\/10.1007\/s10916-023-01931-6","relation":{},"ISSN":["1573-689X"],"issn-type":[{"value":"1573-689X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,24]]},"assertion":[{"value":"14 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Approval was obtained from the ethics committee of University Heinrich Heine University, D\u00fcsseldorf, Germany. The procedures used in this study adhere to the tenets of the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"The authors did not receive support from any organization for the submitted work. The authors have no relevant financial or non-financial interests to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"39"}}