{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T02:12:27Z","timestamp":1771985547754,"version":"3.50.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T00:00:00Z","timestamp":1735862400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T00:00:00Z","timestamp":1735862400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Med Syst"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements. The effectiveness of the phantom as a training tool was assessed through a standardized user experience questionnaire, which evaluated the physical attributes, realism, and overall satisfaction. The mechanical properties of the phantom brain were quantified by measuring catheter insertion forces using a linear force tester to compare them to those experienced in real brain tissue. The study participants successfully completed EVD placements with a 76.7% optimal placement rate, which aligns with rates observed in clinical practice. Feedback highlighted the anatomical accuracy of the phantom and its value in enhancing surgical skills, though it also identified areas for improvement, particularly in the realism of the skin layer. Mechanical testing demonstrated that the insertion forces required were comparable to those encountered in actual brain tissue. The developed phantom offers a realistic, low-cost, and adaptable model for EVD simulation. This tool is particularly beneficial for both training and research, with future enhancements planned to improve the realism of the skin and incorporate more anatomical features to increase the fidelity of the simulation.<\/jats:p>","DOI":"10.1007\/s10916-024-02133-4","type":"journal-article","created":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T07:03:33Z","timestamp":1735887813000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Development and Validation of a Neurosurgical Phantom for Simulating External Ventricular Drain Placement"],"prefix":"10.1007","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9531-2765","authenticated-orcid":false,"given":"Jesse A. M.","family":"van Doormaal","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8900-7492","authenticated-orcid":false,"given":"Tim","family":"Fick","sequence":"additional","affiliation":[]},{"given":"Ernest","family":"Boskovic","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5587-0439","authenticated-orcid":false,"given":"Eelco W.","family":"Hoving","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7845-6196","authenticated-orcid":false,"given":"Pierre A. J. T.","family":"Robe","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6299-3859","authenticated-orcid":false,"given":"Tristan P. C.","family":"van Doormaal","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2025,1,3]]},"reference":[{"key":"2133_CR1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMvcm1805314","volume":"384","author":"RH Dossani","year":"2021","unstructured":"Dossani RH, Patra DP, Terrell DL, Willis B (2021) Placement of an External Ventricular Drain. N Engl J Med 384:e3. https:\/\/doi.org\/10.1056\/NEJMvcm1805314","journal-title":"N Engl J Med"},{"key":"2133_CR2","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1016\/j.jocn.2013.09.001","volume":"21","author":"BP Rosenbaum","year":"2014","unstructured":"Rosenbaum BP, Vadera S, Kelly ML, et al (2014) Ventriculostomy: Frequency, length of stay and in-hospital mortality in the United States of America, 1988-2010. J Clin Neurosci Off J Neurosurg Soc Australas 21:623\u2013632. https:\/\/doi.org\/10.1016\/j.jocn.2013.09.001","journal-title":"J Clin Neurosci Off J Neurosurg Soc Australas"},{"key":"2133_CR3","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/j.jocn.2021.10.014","volume":"94","author":"MJ Stuart","year":"2021","unstructured":"Stuart MJ, Antony J, Withers TK, Ng W (2021) Systematic review and meta-analysis of external ventricular drain placement accuracy and narrative review of guidance devices. J Clin Neurosci Off J Neurosurg Soc Australas 94:140\u2013151. https:\/\/doi.org\/10.1016\/j.jocn.2021.10.014","journal-title":"J Clin Neurosci Off J Neurosurg Soc Australas"},{"key":"2133_CR4","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.surneu.2007.05.007","volume":"70","author":"BR O\u2019Neill","year":"2008","unstructured":"O\u2019Neill BR, Velez DA, Braxton EE, et al (2008) A survey of ventriculostomy and intracranial pressure monitor placement practices. Surg Neurol 70:268\u2013273; discussion 273. https:\/\/doi.org\/10.1016\/j.surneu.2007.05.007","journal-title":"Surg Neurol"},{"key":"2133_CR5","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/JNN.0000000000000174","volume":"48","author":"M Hepburn-Smith","year":"2016","unstructured":"Hepburn-Smith M, Dynkevich I, Spektor M, et al (2016) Establishment of an External Ventricular Drain Best Practice Guideline: The Quest for a Comprehensive, Universal Standard for External Ventricular Drain Care. J Neurosci Nurs 48:54. https:\/\/doi.org\/10.1097\/JNN.0000000000000174","journal-title":"J Neurosci Nurs"},{"key":"2133_CR6","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.jocn.2017.07.025","volume":"45","author":"T Akhigbe","year":"2017","unstructured":"Akhigbe T, Zolnourian A, Bulters D (2017) Mentoring models in neurosurgical training: Review of literature. J Clin Neurosci Off J Neurosurg Soc Australas 45:40\u201343. https:\/\/doi.org\/10.1016\/j.jocn.2017.07.025","journal-title":"J Clin Neurosci Off J Neurosurg Soc Australas"},{"key":"2133_CR7","doi-asserted-by":"publisher","first-page":"54","DOI":"10.14245\/ns.1836008.004","volume":"15","author":"A Seicean","year":"2018","unstructured":"Seicean A, Kumar P, Seicean S, et al (2018) Impact of Resident Involvement in Neurosurgery: An American College of Surgeons\u2019 National Surgical Quality Improvement Program Database Analysis of 33,977 Patients. Neurospine 15:54\u201365. https:\/\/doi.org\/10.14245\/ns.1836008.004","journal-title":"Neurospine"},{"key":"2133_CR8","doi-asserted-by":"publisher","first-page":"570","DOI":"10.3171\/2023.5.JNS222861","volume":"140","author":"E Burkhardt","year":"2024","unstructured":"Burkhardt E, Adeeb N, Terrell D, et al (2024) Factors impacting neurosurgery residents\u2019 operative case volume: a nationwide survey. J Neurosurg 140:570\u2013575. https:\/\/doi.org\/10.3171\/2023.5.JNS222861","journal-title":"J Neurosurg"},{"key":"2133_CR9","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1002\/bjs.11325","volume":"106","author":"HK James","year":"2019","unstructured":"James HK, Chapman AW, Pattison GTR, et al (2019) Systematic review of the current status of cadaveric simulation for surgical training. Br J Surg 106:1726\u20131734. https:\/\/doi.org\/10.1002\/bjs.11325","journal-title":"Br J Surg"},{"key":"2133_CR10","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1093\/bjs\/znaa162","volume":"108","author":"P Angelos","year":"2021","unstructured":"Angelos P (2021) Double-edged sword of surgical innovation: ethical issues of early and late adoption of novel techniques. Br J Surg 108:107\u2013108. https:\/\/doi.org\/10.1093\/bjs\/znaa162","journal-title":"Br J Surg"},{"key":"2133_CR11","doi-asserted-by":"publisher","first-page":"e850","DOI":"10.1016\/j.wneu.2019.08.262","volume":"133","author":"EA Patel","year":"2020","unstructured":"Patel EA, Aydin A, Cearns M, et al (2020) A Systematic Review of Simulation-Based Training in Neurosurgery, Part 1: Cranial Neurosurgery. World Neurosurg 133:e850\u2013e873. https:\/\/doi.org\/10.1016\/j.wneu.2019.08.262","journal-title":"World Neurosurg"},{"key":"2133_CR12","doi-asserted-by":"publisher","first-page":"1853","DOI":"10.1007\/s10143-020-01378-0","volume":"44","author":"J Davids","year":"2021","unstructured":"Davids J, Manivannan S, Darzi A, et al (2021) Simulation for skills training in neurosurgery: a systematic review, meta-analysis, and analysis of progressive scholarly acceptance. Neurosurg Rev 44:1853\u20131867. https:\/\/doi.org\/10.1007\/s10143-020-01378-0","journal-title":"Neurosurg Rev"},{"key":"2133_CR13","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1007\/s10143-020-01314-2","volume":"44","author":"TR Meling","year":"2021","unstructured":"Meling TR, Meling TR (2021) The impact of surgical simulation on patient outcomes: a systematic review and meta-analysis. Neurosurg Rev 44:843\u2013854. https:\/\/doi.org\/10.1007\/s10143-020-01314-2","journal-title":"Neurosurg Rev"},{"key":"2133_CR14","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.3171\/2014.12.JNS141867","volume":"123","author":"BL Tai","year":"2015","unstructured":"Tai BL, Rooney D, Stephenson F, et al (2015) Development of a 3D-printed external ventricular drain placement simulator: technical note. J Neurosurg 123:1070\u20131076. https:\/\/doi.org\/10.3171\/2014.12.JNS141867","journal-title":"J Neurosurg"},{"key":"2133_CR15","doi-asserted-by":"publisher","first-page":"537","DOI":"10.3390\/bioengineering9100537","volume":"9","author":"M Lai","year":"2022","unstructured":"Lai M, Skyrman S, Kor F, et al (2022) Development of a CT-Compatible, Anthropomorphic Skull and Brain Phantom for Neurosurgical Planning, Training, and Simulation. Bioeng Basel Switz 9:537. https:\/\/doi.org\/10.3390\/bioengineering9100537","journal-title":"Bioeng Basel Switz"},{"key":"2133_CR16","doi-asserted-by":"publisher","first-page":"S138","DOI":"10.1227\/NEU.0000000000000113","volume":"73","author":"FJ Bova","year":"2013","unstructured":"Bova FJ, Rajon DA, Friedman WA, et al (2013) Mixed-Reality Simulation for Neurosurgical Procedures. Neurosurgery 73:S138. https:\/\/doi.org\/10.1227\/NEU.0000000000000113","journal-title":"Neurosurgery"},{"key":"2133_CR17","doi-asserted-by":"publisher","first-page":"707","DOI":"10.3109\/02688697.2014.913775","volume":"28","author":"C Craven","year":"2014","unstructured":"Craven C, Baxter D, Cooke M, et al (2014) Development of a modelled anatomical replica for training young neurosurgeons. Br J Neurosurg 28:707\u2013712. https:\/\/doi.org\/10.3109\/02688697.2014.913775","journal-title":"Br J Neurosurg"},{"key":"2133_CR18","doi-asserted-by":"publisher","first-page":"137","DOI":"10.3171\/2018.2.PEDS17671","volume":"22","author":"RJ Garling","year":"2018","unstructured":"Garling RJ, Jin X, Yang J, et al (2018) Low-cost endoscopic third ventriculostomy simulator with mimetic endoscope. J Neurosurg Pediatr 22:137\u2013146. https:\/\/doi.org\/10.3171\/2018.2.PEDS17671","journal-title":"J Neurosurg Pediatr"},{"key":"2133_CR19","doi-asserted-by":"publisher","first-page":"330","DOI":"10.3390\/biomedicines11020330","volume":"11","author":"M Encarnacion Ramirez","year":"2023","unstructured":"Encarnacion Ramirez M, Ramirez Pena I, Barrientos Castillo RE, et al (2023) Development of a 3D Printed Brain Model with Vasculature for Neurosurgical Procedure Visualisation and Training. Biomedicines 11:330. https:\/\/doi.org\/10.3390\/biomedicines11020330","journal-title":"Biomedicines"},{"key":"2133_CR20","doi-asserted-by":"publisher","first-page":"82","DOI":"10.3171\/2014.9.PEDS1447","volume":"15","author":"GE Breimer","year":"2015","unstructured":"Breimer GE, Bodani V, Looi T, Drake JM (2015) Design and evaluation of a new synthetic brain simulator for endoscopic third ventriculostomy. J Neurosurg Pediatr 15:82\u201388. https:\/\/doi.org\/10.3171\/2014.9.PEDS1447","journal-title":"J Neurosurg Pediatr"},{"key":"2133_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/2017.1.PEDS16568","volume":"20","author":"P Weinstock","year":"2017","unstructured":"Weinstock P, Rehder R, Prabhu SP, et al (2017) Creation of a novel simulator for minimally invasive neurosurgery: fusion of 3D printing and special effects. J Neurosurg Pediatr 20:1\u20139. https:\/\/doi.org\/10.3171\/2017.1.PEDS16568","journal-title":"J Neurosurg Pediatr"},{"key":"2133_CR22","doi-asserted-by":"publisher","first-page":"314","DOI":"10.3171\/jns.2004.101.2.0314","volume":"101","author":"Z-J Chen","year":"2004","unstructured":"Chen Z-J, Gillies GT, Broaddus WC, et al (2004) A realistic brain tissue phantom for intraparenchymal infusion studies. J Neurosurg 101:314\u2013322. https:\/\/doi.org\/10.3171\/jns.2004.101.2.0314","journal-title":"J Neurosurg"},{"key":"2133_CR23","doi-asserted-by":"publisher","first-page":"5511","DOI":"10.1088\/0031-9155\/58\/16\/5511","volume":"58","author":"RK Chen","year":"2013","unstructured":"Chen RK, Shih AJ (2013) Multi-modality gellan gum-based tissue-mimicking phantom with targeted mechanical, electrical, and thermal properties. Phys Med Biol 58:5511\u20135525. https:\/\/doi.org\/10.1088\/0031-9155\/58\/16\/5511","journal-title":"Phys Med Biol"},{"key":"2133_CR24","doi-asserted-by":"publisher","first-page":"E14","DOI":"10.3171\/2021.5.FOCUS21200","volume":"51","author":"T Fick","year":"2021","unstructured":"Fick T, Doormaal JAM van, Tosic L, et al (2021) Fully automatic brain tumor segmentation for 3D evaluation in augmented reality. Neurosurg Focus 51:E14. https:\/\/doi.org\/10.3171\/2021.5.FOCUS21200","journal-title":"Neurosurg Focus"},{"key":"2133_CR25","doi-asserted-by":"publisher","first-page":"e9","DOI":"10.1016\/j.wneu.2021.07.099","volume":"156","author":"JAM van Doormaal","year":"2021","unstructured":"van Doormaal JAM, Fick T, Ali M, et al (2021) Fully Automatic Adaptive Meshing Based Segmentation of the Ventricular System for Augmented Reality Visualization and Navigation. World Neurosurg 156:e9\u2013e24. https:\/\/doi.org\/10.1016\/j.wneu.2021.07.099","journal-title":"World Neurosurg"},{"key":"2133_CR26","doi-asserted-by":"publisher","unstructured":"Kakarla UK, Kim LJ, Chang SW, et al (2008) Safety and accuracy of bedside external ventricular drain placement. Neurosurgery 63:ONS162\u2013166; discussion ONS166\u2013167. https:\/\/doi.org\/10.1227\/01.neu.0000335031.23521.d0","DOI":"10.1227\/01.neu.0000335031.23521.d0"},{"key":"2133_CR27","doi-asserted-by":"publisher","first-page":"4840","DOI":"10.1109\/EMBC.2015.7319477","volume-title":"2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","author":"Zhuoqi Cheng","year":"2015","unstructured":"Zhuoqi Cheng, Chauhan M, Davies BL, et al (2015) Modelling needle forces during insertion into soft tissue. In: 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). IEEE, Milan, pp 4840\u20134844"},{"key":"2133_CR28","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1109\/10.771205","volume":"46","author":"MA Howard","year":"1999","unstructured":"Howard MA, Abkes BA, Ollendieck MC, et al (1999) Measurement of the force required to move a neurosurgical probe through in vivo human brain tissue. IEEE Trans Biomed Eng 46:891\u2013894. https:\/\/doi.org\/10.1109\/10.771205","journal-title":"IEEE Trans Biomed Eng"},{"key":"2133_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2023.107852","volume":"231","author":"NLA Nawabi","year":"2023","unstructured":"Nawabi NLA, Stopa BM, Lassar\u00e9n P, et al (2023) External ventricular drains and risk of freehand placement: A systematic review and meta-analysis. Clin Neurol Neurosurg 231:107852. https:\/\/doi.org\/10.1016\/j.clineuro.2023.107852","journal-title":"Clin Neurol Neurosurg"}],"container-title":["Journal of Medical Systems"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-024-02133-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s10916-024-02133-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s10916-024-02133-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T08:03:42Z","timestamp":1735891422000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s10916-024-02133-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,3]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["2133"],"URL":"https:\/\/doi.org\/10.1007\/s10916-024-02133-4","relation":{},"ISSN":["1573-689X"],"issn-type":[{"value":"1573-689X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,3]]},"assertion":[{"value":"10 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Patient data was retrospectively selected from an anonymous secured database, which was previously approved and collected by the University Medical Centre Utrecht's clinical trial bureau [, ].","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics Approval"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"1"}}